Pro Line Front-Loading Gas Dryer
PRODUCT MODEL NUMBERS
OVERALL DIMENSIONS
KHGV01R
57"
(144.8 cm)
Electrical: A 3 or 4 wire, single phase, 120/240
volt 60 Hz, AC only electrical supply (or 3 or 4 wire,
120/208 volt electrical supply, if specified on the
serial/rating plate) on a separate 30-amp circuit,
fused on both sides of the line. A time-delay fuse or
circuit breaker is recommended. Connect to an
individual branch circuit. Do not have a fuse in the
neutral or grounding circuit.
42"**
(106.7 cm)
*Includes door handle
**Includes feet extended 1" (2.5 cm)
Exhaust venting: Exhaust your dryer to the
outside. Four inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do not
use plastic or metal foil vent. Exhaust outlet hood
must be at least 12 inches from the ground or any
object that may be in the path of the exhaust.
NOTE: Most installations require a minimum
5" (12.7 cm) clearance behind the dryer for
the exhaust vent with elbow. See Installations
Instructions, “Venting Requirements.”
33"*
(83.8 cm)
27"
(68.6 cm)
UNDERCOUNTER INSTALLATION
RECESSED AREA AND CLOSET INSTALLATION WITH OR WITHOUT PEDESTAL
Dimensions shown are for minimum spacing.
For closet installation, with a door, the minimum ventilation openings in the top and
bottom of the door are required. Louvered doors with equivalent air ventilation openings
in the top and bottom are acceptable.
1"
(2.5 cm)
42" min.
(106.7 cm)
3"*
(7.6 cm)
48 in.2*
(310 cm2)
1"
(2.5 cm)
27"
(68.6 cm)
1"
(2.5 cm)
EXHAUST VENTING
24 in.2*
(155 cm2)
3"*
(7.6 cm)
Recommended hood style
1"
(2.5 cm)
33"
27"
1"
5"
(12.7 cm)
1"
(83.8 cm)
(2.5 cm)
(68.6 cm)
(2.5 cm)
B
A
C
B
Angled hood style is
acceptable.
A. Front view
B. Side view - closet or confined area
C. Closet door with vents
A
4"
(10.2 cm)
*Required spacing
4"
(10.2 cm)
2.5"
(6.4 cm)
7"* (17.8 cm)
7"* (17.8 cm)
4"
(10.2 cm)
A. Louvered hood style
B. Box hood style
Vent system chart 1 - rigid metal vent only
Number of Type of
Box or
louvered
hoods
Angled
hoods
90º turns
vent
Recommended installation
or elbows
spacing for cabinet installation
For cabinet installation, with a door,
the minimum ventilation openings in
the top are required.
0
1
2
3
4
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
174 ft (53.0 m) 168 ft (51.2 m)
164 ft (50.0 m) 158 ft (48.0 m)
154 ft (46.9 m) 148 ft (45.1 m)
145 ft (44.2 m) 139 ft (42.4 m)
137 ft (41.8 m) 131 ft (39.9 m)
1"
(2.5 cm)
27"
(68.6 cm)
1"
1"
(2.5 cm)
5"
33"
(83.8 cm)
(2.5 cm)
(12.7 cm)
B
C
A
Vent system chart 2 - rigid metal vent used with a
maximum of 8 ft (2.4 m) flexible metal vent
A. Front view
B. Side view
C. Cabinet with vents
Number of Type of
Box or
louvered
hoods
Angled
hoods
90º turns
vent
or elbows
• Select the route that will provide the straightest and most direct path outdoors.
• Plan the installation to use the fewest number of elbows and turns. Use the fewest
90° turns possible.
• Do not use vent runs longer than specified in vent length chart.
• Determine the number of elbows you will need.
0
1
2
3
Rigid metal
Rigid metal
Rigid metal
Rigid metal
144 ft (43.9 m) 138 ft (42.1 m)
134 ft (40.8 m) 128 ft (39.0 m)
125 ft (38.1 m) 119 ft (36.3 m)
117 ft (35.7 m) 111 ft (33.8 m)
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 3957653
06-27-06
|