Kodak Printer CIS 221 User Manual

September 2001 CIS-221  
CURRENT INFORMATION SUMMARY  
Calibrating KODAK PROFESSIONAL  
PORTRA Black & White Paper in the  
Durst Dice America Epsilon 30 LED  
Printer  
5. Expose and process the calibration target image. Read  
This procedure will show you how to use the controls within  
the Epsilon 30 Printer to adjust exposure of each CMY color  
separately to give a final excellent black-and-white image.  
This procedure will show you how to control cyan with the  
Density filter, magenta with the M filter, and yellow with the  
Y filter.  
The initial M, Y, and Density filter settings in the  
procedure below were determined for the Epsilon 30 with  
LED cooling kit, Software Version 2.5 Revision 02 only.  
Settings for other models may differ slightly.  
just the C, M, and Y separation D-max steps with a  
handheld X-Rite densitometer. You may need the color  
reference target mentioned above to locate the C, M,  
and Y D-max steps. The aim densities are as follows:  
Cyan D-max  
R 1.50 ± 0.05  
Magenta D-max  
G 1.22 ± 0.04  
B 0.58 0.03  
(no upper tolerance)  
Yellow D-max  
If any of the measured densities are outside the ranges  
specified, or if any of the next lower steps to the D-max  
step appear to have hit a plateau for several steps,  
proceed to step 6; otherwise, go to step 7.  
Use a color print of the Epsilon 30 calibration target for  
color comparison. Note the location of the cyan, magenta  
and yellow separation step tablets and locate the D-max step  
in each tablet (extreme right)—they are not obvious in the  
monochrome print.  
The procedure below requires that an X-Rite densitometer  
(or equivalent color densitometer) is available to hand read  
the RGB densities from the C, M, and Y separation D-max  
steps.  
6. If the red density of the cyan D-max step is too dark  
(greater than 1.55) or too light (less than 1.45), adjust  
the Density filter (only), and repeat the exposure/  
process cycle with each new Density setting until the  
red density is on aim. (Example, if your first exposure  
is too dark, you need to add Density in the “current  
paper calibration” menu to reduce exposure.)  
PROCEDURE  
Note: Do not calculate a new LUT (Look Up Table)  
1. Start by selecting “Paper,” “List Paper Types,” then  
“New Paper” in the Durst calibration system  
between iterations.  
Proceed to Step 7 when the red density is in range.  
2. Select “New Reflection Paper” and set up  
“Description,” “Width,” and “Length.” Leave  
everything else at their default values.  
7. If the green or blue D-max densities are too high, keep  
the Density filter at the same value as in Step 6 and  
repeat the exposure/process cycle with new M and Y  
filter settings. Add M filtration if the green D-max is  
too high; subtract M or Y filtration if the green or blue  
D-max is too low. Do so until the green and blue  
densities of the D-max steps are on aim and the  
adjacent steps can be discerned (no plateau).  
3. “Open” the file and then “Paper,” “Paper Calibration,”  
and “Show Current Paper Data.”  
4. Set the following “Basic Calibration Filter” values to:  
D
0.700  
0.000  
0.000  
0.000  
Cyan  
Magenta  
Yellow  
Note: Up to now you should not have read the strip  
using the Epsilon X-rite DTP36, nor should you have  
ever run an Epsilon “calculate” step. Your last  
calibration exposure should be on aim for C, M, and Y  
D-max. The text in the calibration target image should  
look clean and should have very little fringing. (See the  
text above step 21 in the neutral tablet; that text is very  
small but should look clean.)  
Do not adjust the cyan value at any time; this is always  
zero (0.000).  
©Eastman Kodak Company, 2001  
 

Ingersoll Rand Paint Sprayer PP20A XXX XXX User Manual
JL Audio Car Speaker SB F RTRKCTR 12W3v2 User Manual
JVC CRT Television AV 27F475 User Manual
JVC Headphones HAEBX85P User Manual
JVC VCR LPT0684 001A User Manual
Kenwood MP3 Player MGR A7 User Manual
KitchenAid Coffeemaker KCM515 User Manual
Kobe Range Hoods Ventilation Hood RA3830SQD User Manual
Kodak Digital Camera CD24 User Manual
Konica Minolta Printer 1650EN User Manual