CONTENT  
PAGE  
Intended Use  
2
2
2
2
2
4
4
Items supplied  
Description of the appliance  
Technical data  
Safety instructions  
Commissioning  
Charging batteries  
Calculating the average charging time..........................................................................................5  
Automatic charging control/Retention charging...........................................................................5  
Timer control ....................................................................................................................................6  
Troubleshooting  
Cleaning  
6
6
6
7
7
Disposal  
Warranty & Service  
Importer  
Read these operating instructions carefully before using the appliance for the first time and preserve this  
maual for later reference. Pass this manual on to whoever might acquire the appliance at a future date.  
 
- 1 -  
ALL-PURPOSE BATTERY  
CHARGER  
Charging currents:  
6 x 400 mA (Type AAA)  
6 x 1000 mA (Type AA)  
Intended Use  
4 x 1000 mA (Types C or D)  
2 x 70 mA (9 V Block battery)  
The All Purpose Battery Charger is intended  
exclusively for:  
• for the charging of rechargeable Ni Cd and  
Ni MH batteries with the sizes AAA/AA/C/D  
and 9 V block batteries to standard commercial  
rating capacities.  
• domestic use only, it is not intended for commer  
cial applications.  
Safety instructions  
Fire hazard!  
Do not place the Battery Charger:  
• where it would be subject to direct sunlight.  
It could happen that the Battery Charger over  
heats and becomes irreparably damaged.  
• in close adjacency to sources of heat. This inclu  
des for example ovens, fan heaters and similar  
appliances, as well as the ventilation openings  
of electrical devices. The Battery Charger could  
be irreparably damaged.  
Items supplied  
• All Purpose Battery Charger  
• Operating manual  
• in damp environments or in the vicinity of water.  
Moisture could permeate into the Battery Charger.  
There would then be the danger of receiving an  
electric shock and or causing a fire!  
• Only charge rechargable batteries of the types  
„Ni Cd“ and „Ni MH“. NEVER recharge batteries  
of other types or non rechargable batteries.  
These are not suitable for recharging. Batteries  
not suitable for recharging can overheat and  
explode. It could irreparably damage the  
Battery Charger and the inserted batteries.  
There is also a risk of personal injury!  
Description of the appliance  
Charging slots for 9 V Block batteries  
(Charging slots 5 and 6; see fold out side)  
Charging slots for AAA / AA / C / D batteries  
(Charging slots 1 to 4; see fold out side)  
LEDs (Operating status indicator)  
q
w
e
Technical data  
Input Voltage:  
AC 100 240 V  
60/50 Hz  
350 mA  
~
Power consumption:  
Protection class:  
II /  
Operating temperature:  
Storage temperature:  
Output voltages:  
0°C 25°C  
20°C 50°C  
6 x 1.4 V  
(Charging slots 1 4)  
2 x 9 V  
(Charging slots 5 6)  
 
- 2 -  
Danger of electrical shock!  
Do not place the Battery Charger:  
• in the close vicinity of water, e. g. baths and  
swimming pools. Should water permeate into the  
Battery Charger, the appliance could be irrepar  
ably damaged.  
• Remove the power cable from the plug socket  
before cleaning the Battery Charger. You can  
thus avoid an electric shock. Should water or  
moisture permeate the Battery Charger despite  
observing all precautions, immediately remove  
the power cable from the plug socket.  
• No liability or warranty will be accepted for  
damage caused by opening the appliance  
housing, repairs attempted by non qualified  
persons or improper use of the Battery Charger!  
• Leakage of battery acids can occur, especially  
with old batteries. You should remove all batteries  
from the Battery Charger if you do not intend to  
use it for an extended period. You can thus  
protect the Battery Charger from leaking battery  
acids.  
• This appliance is not intended for use by persons  
(including children) with reduced physical, sen  
sorial or mental capabilities, or lack of experience  
and knowledge, unless they have been given  
supervision or instruction concerning use of the  
appliance by a person responsible for their  
safety.  
This device suitable only for use indoors.  
Injury hazard!  
• Always store batteries out of the reach of  
children! There is a danger that children could  
swallow batteries! Due to the poisonous content  
of batteries there is a danger to life!  
• Children should be supervised to ensure that  
they do not play with the appliance.  
• When charging batteries never leave the  
Battery Charger unsupervised.  
Interaction with batteries  
• Do not use damaged (corroded) batteries.  
• Should batteries leak, avoid skin contact with  
them. This leads to skin irritation.  
• The batteries could become hot during charging.  
NEVER touch hot batteries! There is a risk of  
being burnt! After charging batteries, first of all  
remove the power cable of the Battery Charger  
from the plug socket. Then allow the batteries to  
cool down before removing them from the  
Battery Charger.  
• Should a battery leak into the Battery Charger,  
clean it with a dry cloth. Wear protective gloves!  
• Should the power cable be defective, immedia  
tely arrange for it to be replaced by a service  
partner to avoid the risk of injury.  
• The Battery Charger does not contain any user  
serviceable components. Should you open the  
housing of the Battery Charger, the warranty  
expires! Should repairs be needed, contact one  
of our service partners in your area.  
 
- 3 -  
Commissioning  
Notice:  
Ensure that the batteries are inserted into the  
charging slots in accordance with their polarities.  
Otherwise, the batteries will not be charged.  
• Before taking the Battery Charger into use,  
check that all items are complete/available and  
free of visible damage.  
• Place the Battery Charger on a straight, level,  
scratch and slip resistant surface.  
• Insert the batteries into the charging slots.  
• Press the 9 V Block batteries into the charging  
slot until they audibly engage.  
Notice:  
1 to 8 batteries can be individually charged:  
• 4 x Type C or Type D batteries in the charging  
slots 1 to 4, with additionally 2 x Type 9 Volt  
Block batteries in the charging slots 5 and 6.  
or  
• 6 x Type AA or AAA batteries in the charging  
slots 1 to 4, with additionally 2 x Type 9 Volt  
Block batteries in the charging slots 5 and 6.  
• The charging process now begins. The Battery  
Charger has an LED for each charging slot. The  
LEDs of the charging slots indicate the charge  
state of the battery they contain.  
This appliance is equipped with non slip rubber feet.  
As furniture surfaces may be made of a variety of  
materials and are treated with many different types  
of cleaning agents, it cannot be completely ruled  
out that some substances contain ingredients which  
may corrode the rubber feet and soften them. If pos  
sible, place an anti slip material under the device.  
• Compare the technical data with that of your  
current mains power supplier. If they are the  
same, connect the power cable to a mains  
power socket. The LEDs blink red three times.  
The Battery Charger is now ready for use.  
• In the first 5 seconds the Battery Charger carries  
out a capacity test:  
The LED of the charging slot glows green:  
The battery capacity lies over 90 %.  
The LED of the charging slot glows orange:  
The battery capacity lies between 80 % 90 %.  
The LED of the charging slot glows red:  
The battery capacity lies under 80 %.  
The LED of the charging slot blinks red  
The battery is not properly inserted into the  
charging slot or is defect.  
Charging batteries  
Danger!  
Charge exclusively rechargable batteries of the  
types „Ni Cd“ and „Ni MH“.  
:
NEVER recharge batteries of other types or non  
rechargable batteries. These are not suitable for  
recharging. They could irreparably damage the  
Battery Charger and the inserted batteries. There is  
also the danger of a fire as well as an explosion!  
When the battery capacity has been determined,  
the charging process begins.  
 
- 4 -  
The various indicators have the following meanings:  
Calculating the average charging time  
Dependant on the type, age and remaining battery  
charge, hence the charging process takes different  
lengths of time. The average charging times can be  
calculated using the following formula.  
The LED blinks alternatively red and green:  
The batteries are being charged and discharged  
alternately. (Refresh function: With this, older  
batteries or batteries that have been stored for a  
long time will be refreshed.)  
Note, however, that the times calculated are only  
indicative.  
The LED blinks green:  
Current time (Min.) =  
The batteries are being charged by a battery  
preserving impulse charge.  
Capacity of the battery (mAh) x 1,5 x 60  
Charging current of the appliance (mA)  
The LED continuously glows red:  
The batteries are being charged with the maximum  
charge current.  
Automatic charging control/  
Retention charging  
This Battery Charger controls the charging time for  
rechargable batteries of the types Ni Cd and Ni MH  
separately. This control is based on the Δ U  
(„minus Delta U“) calculation.  
The LED continuously glows green:  
The batteries are fully charged and the Battery  
Charger has switched to a trickle charge.  
In mathematics, with Delta Δ differences are  
described.  
Notice:  
„Minus Delta U“ in this case means a negative  
voltage difference.  
This charge identification makes itself useful in the  
following effects:  
Should Type C or D batteries be charged in the outer  
charging slots, the operating condition is displayed  
by the respective outer LEDs.  
Should a battery be charged with a constant current,  
its voltage rises continuously. When the battery is  
full, its voltage reaches a maximum and falls lightly  
with further current flow. This light fall in voltage is  
recognised by the charging electronics and the  
charge process is terminated. The Battery Charger  
automatically switches to „Retention charging“.  
This means that the batteries are no longer being  
charged with continuous power, but with short power  
impulses instead. This counteracts the process of  
self discharge, thus retaining the batteries in a fully  
charged condition.  
Warning!  
The batteries could become hot during charging.  
NEVER touch hot batteries! There is a danger of  
being burnt!  
• Remove the power cable of the Battery Charger  
from the plug socket and allow the batteries to  
cool down.  
Afterwards you can remove the charged batteries  
from the Battery Charger.  
 
- 5 -  
Timer control  
Cleaning  
In addition, this charger is fitted with a timer control,  
which after 17 hours automatically switches over to  
trickle charge. This serves as additional protection  
against overcharging should the charge terminating  
device not respond, due to a possibly defective  
battery.  
ƽ Danger! Disconnect the power cable before  
cleaning. There is the risk of receiving an  
electric shock! Ensure that moisture cannot  
penetrate into the device during cleaning!  
Clean the housing of the Battery Charger only with  
a dry cloth. For stubborn soiling use a slightly damp  
cloth.  
Under no circumstances use moisture to clean the  
interior of the charger. Instead, use a soft and clean  
brush to clean the insides. DO NOT use abrasive or  
chemical cleaning agents.  
Troubleshooting  
The Battery Charger displays no functions  
• Check to see if the power cable is correctly  
inserted into the power socket.  
• Check to see if the power socket is „live“. To do  
this, connect a different, functioning electrical  
appliance to the socket.  
Disposal  
The inserted batteries are not being charged  
• Check that the batteries are being inserted in  
accord with their polarity.  
• Check that batteries suitable for charging have  
been inserted into the Battery Charger. Suitable  
for charging are exclusively rechargable Ni Cd  
and Ni MH batteries of the types AAA/AA/C/D  
and 9V Block batteries.  
• Remove the power cable from the power socket  
and allow the appliance to cool down, as the  
temperature monitoring has possibly activated  
itself. Temperature monitoring ensures that the  
charging process is broken off as soon as a bat  
tery reaches an excessively high temperature.  
Do not dispose of the appliance in your  
normal domestic waste. This product is  
subject to the European guideline  
2002/96/EC.  
Dispose of the appliance through an approved  
dis posal centre or at your community waste facility.  
Observe the currently applicable regulations.  
In case of doubt, please contact your waste disposal  
centre.  
Battery disposal!  
Batteries may not be disposed of with normal  
domestic waste. All consumers are statutorily obliged  
to dispose of batteries at the collection point in their  
community/district or with the original supplier.  
The purpose of this obligation is to ensure that  
batteries can be disposed of in an environmentally  
friendly manner. Only dispose of batteries when  
they are fully discharged.  
Other malfunctions  
Make contact with one of our service partners close  
to you if:  
• the malfunction cannot be corrected as  
described above,  
• or, when operating the Battery Charger, other  
malfunctions occur.  
Dispose of all packaging materials in an  
environmentally responsible manner.  
 
- 6 -  
Warranty & Service  
Importer  
The warranty for this appliance is for 3 years from  
the date of purchase. The appliance has been  
manufactured with care and meticulously examined  
before delivery. Please retain your receipt as proof  
of purchase. In the event of a warranty claim, please  
make contact by telephone with our Service Depart  
ment. Only in this way can a post free despatch for  
your goods be assured.  
KOMPERNASS GMBH  
BURGSTRASSE 21  
44867 BOCHUM, GERMANY  
The warranty covers only claims for material and  
maufacturing defects, but not for transport damage,  
for wearing parts or for damage to fragile compo  
nents, e.g. buttons or batteries. This product is for  
private use only and is not intended for commercial  
use. The warranty is void in the case of abusive and  
improper handling, use of force and internal tampe  
ring not carried out by our authorized service  
branch. Your statutory rights are not restricted in  
any way by this warranty.  
The warranty period will not be extended by repairs  
made under warranty. This applies also to replaced  
and repaired parts. Any damage and defects extant  
on purchase must be reported immediately after  
unpacking the appliance, at the latest, two days  
after the purchase date. Repairs made after the  
expiration of the warranty period are subject to  
payment.  
DES UK LTD  
Tel.: 0871 5000 700 (£ 0.10 / minute)  
Kompernass Service Ireland  
Tel: 1850 930 412 (0,082 EUR/Min.)  
Standard call rates apply. Mobile operators may vary.  
 
- 7 -  
 

Innotek Pet Care Product IUT 300E User Manual
Insignia CRT Television NS 20FTV User Manual
Insignia Portable Stereo System NS B2114 User Manual
Invacare Mobility Aid Powered Seating User Manual
Jacuzzi Hot Tub Comfort Plus Bath Series User Manual
Jet Tools Saw VBS 814GH User Manual
Jura Capresso Coffeemaker IMPRESSA C5 User Manual
JVC Digital Camera DULYT1266 004A User Manual
Jwin DVD Player JD VD903 User Manual
Kramer Electronics Vacuum Cleaner WP 121 User Manual