HEARTH PRODUCTS
KITS AND ACCESSORIES
BLOWER KIT
LBLK-100
750,216M
REV. N/C 03/2006
INSTALLATION INSTRUCTIONS FOR BLOWER KIT
LBLK-100 (CATALOG NO. H4678) FOR USE WITH ELDV SERIES FIREPLACES
Step 6. Remove the logs from the fireplace (see Figure 1 ). Handle logs
carefully to prevent breakage.
GENERAL INFORMATION
This blower kit may be used with ELDV series fireplaces. The LBLK-
100 blower kit is used with a field supplied ON/OFF power switch. The
blower is installed beneath the firebox. Room air is drawn in through
the bottom area of the fireplace, heated as it passes across the
firebox, and discharged through the upper open area at the top of the
fireplace. The LBLK-100 blower kit contains one blower, one power
cord and these instructions.
Step 7. Remove the grate asembly, burner baffle, burner asembly
(Figure 2 ) and the blower cover panel (Figure 3 ).
Step 8. Connecttheprovidedpowercordtotheterminalsontheblower.
Blower Cover Panel
Burner Assembly
INSTALLATION INSTRUCTIONS
Step 1. Turn off the fireplace and allow it to cool before proceeding.
Step 2. If the appliance is connected to 120 volt power, disconnect
the power.
Step 3. Shut off the gas supply to the fireplace.
Step 4. Remove the bottom panel of the fireplace by pulling it forward.
(see Figure 1 ).
Step 5. Remove the door assembly by opening the two latches (located
under the door assembly) securing the glass door (see Figure 1 ).
Grate Assembly
Figure 2
Burner Baffle
Logs
Door Asembly
Blower Cover Panel
Bottom Panel
Figure 1
Figure 3
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
WIRING DIAGRAM MILLIVOLT GAS VALVES
THERMOPILE
INTERMITTENT ELECTRONIC WIRING DIAGRAM
120 VAC
SPARK TO PILOT IGNITOR
BK
GR
APPLIANCE- MOUNTED
ON/OFF SWITCH
W
TP-TH
TP
TH
OPTIONAL BLOWER
SWITCH
GAS VALVE
BK/W(1)
BK/W(1)
IGNITOR MODULE
3V
JUNCTION BOX
BLACK (IGNITOR)
BLACK (SENSOR)
WALL-MOUNTED ON/OFF SWITCH (OPTIONAL)
THERMOSTAT (OPTIONAL)
TRANSFORMER 3V
WALL MOUNTED CONFIGURATION FOR FAN SWITCH (OPTIONAL)
FAN
(OPTIONAL)
BLACK
BK
ORANGE (THTP)
BATTERY BACK-UP
R
TO WALL
SWITCH OR
THERMOSTAT
W
BLACK (TP)
GREEN (TH)
T O P I L
HI
LO
RED
GR
BROWN
FAN
(OPTIONAL)
BROWN
JUNCTION BOX
Figure 10
Figure 9
Step 10. Install the field-provided ON/OFF switch in a convenient
location on a wall, near the fireplace.
IMPORTANT: Ground lead must be connected to the green screw
located on the junction box. Failure to do so will prevent the
appliance from operating. The appliance must be electrically
grounded in accordance with local codes or, in the absence of local
codes, the National Electrical Code, ANSI/NFPA 70-(latest edition).
(In Canada, the current CSA C22-1 Canadian Electrical Code.)
Step 11. Route a 3-wire, 120Vac power line to the ON/OFF switch as
shown in Figure 9 (for Millivolt model) and Figure 10 (for Electronic
model).
Then route the wires to the unit’s junction box. Remove the receptacle
box by squeezing the sides of the J-Box and slide the two tabs through
the cutout.
BLOWER ASSEMBLY
Step 12. Connect the supply wires to the receptacle as shown in
Figure 9 (for Millivolt) and Figure 10 (for Electronic). Reinstall the
receptacle box.
Step 13. Plug the blower cord into the receptacle (see Figure 11 ).
Step 14. Reinstall items from Steps 7, 6 and 5.
BLOWER MOUNTING TABS
ELECTRICAL OUTLET
Step 15. Restore the electrical power to the unit.
Step 16. Start the fireplace by following the procedures indicated in
the lighting instructions section of the Homeowners Care And Opera-
tions instructions manual, supplied with the fireplace.
Figure 11
Step 17. Check the start-up and shutdown, and the running operation
of the blower.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
3
The manufacturer reserves the right to make changes at any time, without notice, in design,
materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local distributor for fireplace code information.
Printed in U.S.A. © 2006 by Lennox Hearth Products
P/N 750,216M REV. N/C 03/2006