The conditions which sometimes combine to  
create a feedback loop are:  
each wire into the appropriate hole on the main  
system units’ screwless connector (Figure 2),  
and snap the locking tab down. To help you, the  
connector plug is keyed. Insert the smooth side  
of the connector plug into the smooth side of  
the socket. Don’t force the scalloped side of the  
connector plug into the smooth side of the socket.  
lIMIted Warranty  
NILES AUDIO CORPORATION (“NILES”) WARRANTS ITS ACTIvE PRODUCTS  
(ThOSE NOT REqUIRINg AC OR bATTERy POWER) TO ThE ORIgINAL  
PURChASER TO bE FREE OF MANUFACTURINg DEFECTS IN MATERIAL AND  
WORKMANShIP FOR A PERIOD OF TWO yEARS FROM DATE OF PURChASE.  
ThIS WARRANTy IS SUbjECT TO ThE FOLLOWINg ADDITIONAL CONDITIONS  
AND LIMITATIONS. ThE WARRANTy IS vOID AND INAPPLICAbLE IF  
NILES DEEMS ThAT ThE PRODUCT hAS bEEN USED OR hANDLED OThER  
ThAN IN ACCORDANCE WITh ThE INSTRUCTIONS PROvIDED by ThE  
MANUFACTURER, INCLUDINg bUT NOT LIMITED TO DAMAgE CAUSED by  
ACCIDENT, MIShANDLINg, IMPROPER INSTALLATION, AbUSE, NEgLIgENCE,  
OR NORMAL WEAR AND TEAR, OR ANy DEFECT CAUSED by REPAIR  
TO ThE PRODUCT by ANyONE OThER ThAN NILES OR AN AUThORIZED  
NILES DEALER.  
InstallatIon  
sPeCIFICatIons  
troublesHootInG  
If you are installing the MS120 into an existing wall,  
take time to consider any possible obstructions  
which may be hidden inside the wall, such as wood  
or metal studs; electrical, telephone or other types  
of wiring; plumbing; AC or heating conduits; old  
wall safes; etc.  
IR System  
This manual contains instructions for the MS120  
only. For specific information on the adjustment  
and operation of your Niles infrared extender  
system, please refer to the instruction manual  
included with your Niles IR main system unit  
(MSU140, MSU250, MSU480 MSU440Z).  
1. Both a sensor and a flasher are located within  
Compatible with virtually all brands of remotes  
using carrier frequencies between 25kHz and 90kHz  
the same room.  
I N S T A L L A T I O N  
&
O P E R A T I O N G U I D E  
2. There is some low-level noise or interference  
on your system.  
IR Receiving Range  
Varies depending on remote strength;  
typically 20' to 35' (6.10 meters to 10.68 meters)  
IR Receiving Angle  
You can eliminate optical feedback by replacing  
any IRB1 “flooding flasher” with an MF1 or MF2  
MicroFlasher® and covering all flashers with the  
supplied IR blocking covers.  
6. Secure the MS120 by tightening the hex nut.  
DO NOT OVER-TIGHTEN.  
1. Determine a mounting location for the MS120.  
Select a location where you will have access  
to the rear of the MS120 after it is installed.  
This will allow you to securely tighten the  
MS120 to the mounting surface using the  
supplied hardware.  
1. Test the remote control(s) by operating the  
A/V equipment directly. Replace the batteries  
if needed.  
Tools Required  
TO ObTAIN WARRANTy SERvICE, TAKE ThE UNIT TO ThE NEAREST  
AUThORIZED NILES DEALER, WhO WILL TEST ThE PRODUCT AND IF  
NECESSARy, FORWARD IT TO NILES FOR SERvICE. IF ThERE ARE NO  
AUThORIZED NILES DEALERS IN yOUR AREA, yOU MUST WRITE TO NILES  
AND INCLUDE yOUR NAME, MODEL AND SERIAL NUMbER OF yOUR UNIT,  
ALONg WITh A bRIEF DESCRIPTION OF ThE PRObLEM. A FACTORy RETURN  
AUThORIZATION NUMbER WILL bE SENT TO yOU. DO NOT RETURN ANy  
UNIT WIThOUT FIRST RECEIvINg WRITTEN AUThORIZATION AND ShIPPINg  
INSTRUCTIONS FROM NILES.  
30° off-axis (horizontal and vertical) at 25'  
(7.62 meters)  
• 1/8” Standard Slotted Screwdriver  
• Adjustable wrench or pliers  
• Wire Stripper  
EMI (Electromagnetic Interference)  
2. Double check the cable connections on the  
MS120 and on the main system unit. Look for  
open, shorted or reversed wires.  
Identify the source of the interference. The most  
common sources of electromagnetic interference  
are listed in the Installation Considerations  
section. To eliminate EMI try the following  
methods:  
Mounting  
Thru-hole, fits into a 1/2" (1.27 cm) diameter  
hole; requires a minimum of 2-7/8" (7.31 cm)  
mounting depth  
NOTE: Do not install the MS120 next to a light  
dimmer  
2. Drill a 1/2” hole where the MS120 will be  
mounted.  
3. Test for interference from the following  
sources:  
IFThEAbOvECONDITIONSAREMET,ThEPURChASER’SSOLEREMEDyShALL  
bE TO RETURN ThE PRODUCT TO NILES, IN WhICh CASE NILES WILL REPAIR  
OR REPLACE, AT ITS SOLE OPTION, ThE DEFECTIvE PRODUCT WIThOUT  
ChARgE FOR PARTS OR LAbOR. NILES WILL RETURN A UNIT REPAIRED OR  
REPLACED UNDER WARRANTy by ShIPPINg SAME by ITS USUAL ShIPPINg  
METhOD FROM ThE FACTORy (ONLy) AT ITS ExPENSE WIThIN ThE UNITED  
STATES OF AMERICA. THERE ARE NO OTHER WARRANTIES, INCLUDING  
WITHOUT LIMITATION, EITHER EXPRESS OR IMPLIED WARRANTIES OF  
3. Run the MS120’s IR cable. Label the cable for  
future reference. The MS120 is supplied with  
10’ of pre-stripped IR cable. The IR cable may  
be shortened or lengthened as needed. If you  
want to make the MS120’s cable shorter, use a  
pair of wire cutters to cut the cable to the  
desired length. The IR cable may be lengthened  
by splicing it to a recommended IR cable (See  
Installation Considerations—Type of Cable). You  
may splice the MS120 cable to another cable by  
soldering or crimping the connections.  
• Neon, Compact Florescent Lighting (CFL), or  
halogen lights in the room  
Wiring Requirements  
1. Move the sensor or the sensor cable away  
from the EMI source or move the source of  
the EMI away from the sensor or the cable.  
Individual home-run of CAT-5 cable  
Unit Dimensions  
oPeratIon  
• Light dimmers, beginning with those closest  
to the MS120  
Operation of the MS120 is straightforward. Simply  
aim your hand-held remote at the MS120. Your  
IR command is instantly repeated to your A/V  
equipment.  
Front Bezel:  
3/4" (1.91 cm) diameter x 1/4" (.64 cm) high  
MERCHANTABILITY OR FITNESS FOR  
RESPECT TO THE PRODUCT.  
A
PARTICULAR PURPOSE, WITH  
2. Connect the Sensor’s GND terminal to true  
earth ground (if this isn’t feasible use the  
main system unit’s GND terminal).  
Observe the main system unit IR confirmation  
LED while performing all the tests. It is possible  
to have interference from more than one source.  
REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS WARRANTY IS THE  
EXCLUSIVE REMEDY OF THE CONSUMER/PURCHASER. NILES SHALL NOT  
BE RESPONSIBLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES  
EXCEPT TO THE EXTENT PROVIDED (OR PROHIBITED) BY APPLICABLE LAW.  
SOME STATES DO NOT ALLOW ThE ExCLUSION OR LIMITATION OF  
INCIDENTAL OR CONSEqUENTIAL DAMAgES, SO ThE AbOvE LIMITATION MAy  
NOT APPLy TO yOU. ThIS WARRANTy gIvES yOU SPECIFIC LEgAL RIghTS,  
AND yOU MAy ALSO hAvE OThER RIghTS WhICh vARy FROM STATE  
TO STATE.  
Overall Unit:  
1/2" (1.27 cm) diameter x 2-7/8" (7.31 cm) long  
Bl e n d i n g Hi g H Fi d e l i t y An d Ar c H i t e c t u r e ®  
There are many methods for reducing  
interference. Which solution is best for you  
depends on your situation. If you require further  
assistance call Niles Technical Support at  
305-238-4373 or 1-800-289-4434  
Eliminating Optical Feedback  
Contents  
N i l e s A u d i o C o r p o r a t i o n  
1 2 3 3 1 S . W . 1 3 0 S t r e e t M i a m i , F l o r i d a 3 3 1 8 6  
1 - 3 0 5 - 2 3 8 - 4 3 7 3  
In some installations, two conditions combine to  
create an optical feedback loop. Symptoms can  
include: poor range, intermittent operation or no  
operation.  
MS120 Sensor x 1  
Washer x 1  
4. Connect the MS120 cable to the main system  
unit. Strip 1/4” of insulation from the end of  
each wire. Tightly twist the end of each wire  
until there are no frayed ends. Insert the end of  
®
FOR ThE NAME OF yOUR NEAREST AUThORIZED NILES DEALER  
CONTACT: NILES AUDIO CORPORATION, P.O. bOx 160818, MIAMI,  
FLORIDA 33116-0818.  
FluSH-MouNt IR MICRoSeNSoR  
1 - 8 0 0 - B u y - H i f i  
w w w . n i l e s a u d i o . c o m  
Hex Nut x 1  
(M-F 8:00 AM - 7:00PM ET).  
Black and White Bezel  
Please fill in your product information and retain for your records.  
©2009 Niles Audio Corporation. All rights reserved. Niles, the Niles  
logos, MicroFlasher, MicroSensor and Blending High Fidelity and Architecture are  
registered trademarks of Niles Audio Corporation. All other trademarks are the  
property of their respective owners. DS00671A  
You can also email Niles Technical Support at  
MS120  
Model__________________Purchase Date _________________  
Serial No.____________________________________________  
Download from Www.Somanuals.com. All Manuals Search And1Do2wnload.  
13  
10  
Ms
1
2 0  
9
11  

MTD Yard Vacuum 245 675 000 User Manual
National Instruments Switch 6024E User Manual
NewAir Air Conditioner ACP 1300E User Manual
Nextar Digital Photo Frame N7S 100 User Manual
NuTone Fan PFC 48II User Manual
Nvidia Computer Hardware 8400GS User Manual
Oki Printer ML591 User Manual
Olympus Scanner OLS3100 User Manual
Optimus Cassette Player SCP 86 User Manual
Panasonic Smoke Alarm 6367 User Manual