Omron Healthcare Blood Pressure Monitor HEM 630 User Manual

Instruction Manual  
Ultra Compact Wrist  
Blood Pressure Monitor  
with  
Model HEM-630  
SYS  
m
m
P
Hg  
U
LS  
E
/m  
in  
DIA  
ON  
OFF  
m
m
H
g
M
TIME SET  
/
DATE  
Thank you for purchasing the Omron Ultra Compact Wrist Blood  
Pressure Monitor with IntelliSense™. Please read this instruction  
manual thoroughly before operating to assure proper use.  
For specific information on your own blood pressure,  
CONTACT YOUR PHYSICIAN.  
 
Introduction  
Thank you for purchasing the Omron HEM-630 Ultra Compact Wrist Blood  
Pressure Monitor. This remarkable instrument is ideal for people who frequently  
monitor their own blood pressure because it’s so compact and easy to use.  
There is no tricky arm cuff, just a small, pre-formed wrist cuff that is easy  
to apply. With the push of a button the Omron Wrist Monitor measures your  
blood pressure and pulse and displays the reading on a clear digital panel.  
Perfect for quick, easy readings at home, at work, almost anywhere!  
The Omron Wrist Monitor uses the oscillometric method of blood pressure  
measurement. This means the monitor detects your blood’s movement through  
the artery in your wrist and converts the movements into a digital reading.  
An oscillometric monitor does not need a stethoscope so the monitor is simple  
to use and measurements are easy to obtain.  
Clinical research has proven a direct relationship between blood pressure  
in the wrist and blood pressure in the arm. Changes in wrist blood pressure  
reflect changes in arm blood pressure because the arteries in the wrist  
and the arm connect. Frequently measuring the blood pressure in your  
wrist will provide you and your doctor with an accurate indication  
of changes in your true blood pressure.  
Please read this instruction manual thoroughly before using  
the Omron Ultra Compact Wrist Blood Pressure Monitor.  
For specific information on your own blood pressure,  
CONTACT YOUR PHYSICIAN.  
 
3
Know Your Unit  
Main unit  
Diastolic Blood Pressure /  
Pulse Display  
Systolic Blood  
Pressure Display  
SYS  
mmHg  
PU  
LS  
E
/m  
in  
DIA  
ON  
OFF  
m
m
H
g
M
Wrist Cuff  
TIME SET  
/
DATE  
START/STOP  
Button  
Memory Call Button  
Time Setting Button  
Battery Cover  
Accessories  
Two AAA Alkaline  
batteries (LR03)  
Storage case  
INTELLISENSE™ Blood Pressure Monitor is a global brand  
name of blood pressure monitor equipped with bio-information  
sensing and high performance fuzzy logic technology, which  
are the key technologies of OMRON. With this excellent sensing  
technology, the monitor can achieve "accurate measurement".  
 
4
Battery Installation/Replacement  
Insert the batteries.  
(1) Slide the Battery Cover  
in the direction of an arrow.  
1
(2) Open the Battery Cover.  
2
(3) Insert two AAA batteries  
with the polarities in correct direction.  
3
(4) Pull the Battery Cover toward yourself.  
(5) Slide the Battery Cover to close.  
* Battery Cover slides to open and close.  
Please be careful that if you force  
to open or close the Battery Cover,  
it may be damaged.  
5
4
Battery Life and Replacement  
• High performance alkaline dry cell batteries (2 “AAA”) should be good  
for approximately 400 readings.  
• Battery life varies with ambient temperature. Battery life is shorter under  
cold conditions such as during the winter.  
• The dry cell batteries provided are for monitoring and may  
run down before 400 readings.  
• If the battery replacement symbol blinks while measuring or if pressure  
is not applied when the START / STOP button is pressed, replace both  
batteries (use the same type).  
• Holding the START / STOP button down may shorten battery life. To avoid  
pressure on the button when transporting or storing, use the case provided.  
5
 
Program Date and Time  
Time Setting  
Button  
Set the year, month,  
date, and time.  
SmmHg  
P
U
LS  
E/m  
in  
D
IAmmHg  
M
T
E
TIM  
/
E
T
A
D
Press the Time Setting button  
with something having a sharp  
point (such as ball-point pen)  
while the power is off.  
• "0:00" or the current time  
(when the time is already set)  
is displayed. (If you insert batteries  
for the first time after purchasing  
this monitor, the display will flash.)  
1. Set the "Year".  
Press the Time Setting button  
again. The display flashes  
“2000”  
• "2000" (year) is displayed  
with flashing.  
• Press the Memory Call button and set  
the number representing the "Year"  
Memory Call  
Button  
S
Y
SmmHg  
P
U
LS  
E/m  
in  
D
IAmmHg  
T
E
S
E
IM  
T
/
E
T
A
D
2. Set the "Month".  
Press the Time Setting button.  
• "1/" (month representing January  
in this case) is displayed.  
• Press the Memory Call button and set  
the number representing the "Month".  
6
 
Program Date and Time  
3. Set the "Date".  
Press the Time Setting button.  
• "/1" (date) is displayed.  
• Press the Memory Call button and set  
the number representing the "Date".  
4. In the same manner, set  
the "Hour" and "Minute".  
• The number representing the "Hour"  
is displayed in the 12-hour  
unit of morning and afternoon.  
(For the hour in the afternoon,  
PM is displayed.)  
5. Lastly, the correct time can  
be set by pressing the Time  
Setting button according  
to the time signal when  
"00" is displayed.  
• The current time is displayed and the time  
setting is completed.  
If you measure blood pressure without setting the date and time, blood pressure  
values will be saved with the incorrect date and time. When you use this monitor  
for the first time, or after taking out batteries for a long period of time, be sure  
to adjust the date and time, then use the monitor. After battery replacement,  
confirm the time first, then use the monitor. If batteries are removed for more  
than one minute, you must reset the time.  
7
 
How to Apply the Wrist Cuff  
Wrap the Wrist Cuff.  
* Wrap the wrist cuff over bare skin.  
1. Place the wrist cuff over  
your left wrist with your  
left thumb facing upward.  
* Be sure not to roll in the sleeve  
of your cloth into the wrist cuff.  
* As shown in the Figure, cover  
the wrist cuff by leaving  
a space of 10 to 15 mm  
10 - 15 mm  
(a space almost equal  
to the width of an index  
finger) between the edge  
of the wrist cuff and the  
border of arm and the  
palm of a hand.  
2. Hold the bottom part of the wrist cuff and wrap it around  
the wrist while pulling so that it fits snugly.  
* Unless the wrist cuff is wrapped snugly, correct measurement  
may not be possible.  
* The remaining part of the wrist cuff can be conveniently folded back  
out of the way.  
* For the slender wrist (wrist circumference of less than 145 mm), the wrist  
cuff may not be wrapped snugly and give a feeling of loose wrap. In this  
case, do not force to wrap since the measurement is not affected.  
* Fasten the Velcro tape tightly by closely adhering both sides.  
When measuring  
on the right wrist  
Measurement can also be made  
on the right wrist. Fit the monitor  
as shown in the Figure.  
 
8
Suggestions Before Measureing  
Blood Pressure  
Align the wrist cuff with the level of your heart (breast height)  
and gently support your left hand with your right hand.  
1. Avoid eating, smoking and exercising for at least  
30 minutes before taking measurement. Also rest  
for at least 10 to 15 minutes before taking a reading.  
2. Stress raises blood pressure. Avoid taking  
measurements during stressful times.  
3. The cuff should be applied to your left wrist.  
4. Measurments should be taken in a quiet place  
and you should be in a relaxed, seated position.  
Gently support your left hand in your right hand.  
Do not place your right hand on the cuff itself.  
5. Remain still and do not talk during the measurements.  
6. Keep a record of you blood pressure and pulse for you doctor.  
Remeber, a single measurement does not provide an accurate reading  
of your true blood pressure. You need to take and record several readings  
over a period of time. Try to mesure your blood pressure at the same  
time each day for consistnecy.  
7. Wait 2-3 minutes between successive mesurements. Waiting allows the  
engorged blood vessels to return to normal. You may require more rest time  
between readings depending on your individual physiological characteristics.  
 
9
How to Take a Reading  
When it is ready to measure, take the measurement in the following procedure.  
To start measurement, simply press the START/STOP button.  
1. Press the START/STOP button.  
(1) Press the START/STOP button.  
Release the Button when  
SYSmmHg  
the display turns on.  
PULSE/min DIAmmHg  
(2) Initial display  
All display symbols turn  
on for about 0.5 seconds.  
* The battery replacement mark  
shown here does not mean the  
worn batteries.  
(3) Deflation display  
A
mark starts to flash.  
(4) The monitor starts to inflate  
and measure.  
* Because measurement is made  
during inflation, do not move  
your hand, wrist, or arm after  
the monitor starts to inflate.  
These marks disappear  
one by one as the  
measurement proceeds.  
 
10  
How to Take a Reading  
2. Measurement is over and blood pressure values, pulse,  
time, and date are displayed.  
When the measurement is over, a  
automatically. Then a mark turns on and blood pressure and time  
are displayed alternately, and pulse rate and date are displayed alternately.  
mark flashes, and the cuff deflates  
Display of measurement results  
Display of pulse rate  
Alternating  
display  
* If a measurement cannot be made or the blood pressure values are displayed  
abnormally high (low), refer to Page 28.  
* If the Velcro tape comes off during the measurement, wrap the wrist cuff  
snugly as shown in Page 10 and measure again after fastening the Velcro tape.  
3. Turn off the power.  
Blood pressure measurement is complete now.  
Press the START/STOP button to turn off the power.  
To make another measurement, repeat the procedure in Step 1 above.  
* Even if you forget to turn  
off the power, the monitor  
SYSmmHg  
will turn off automatically  
in approximately 2 minutes.  
PULSE/min  
DIAmmHg  
 
11  
Memory Feature  
How to Use the Memory Function  
The HEM-630 Blood Pressure Monitor with Fuzzy Control has a function  
to record up to twenty-one measurements.  
1. Press the MEMORY CALL button ("M" button).  
The latest measurements are displayed.  
Alternating  
SYSmmHg  
SYSmmHg  
display  
PULSE/min DIAmmHg  
Press the "M" button.  
SYSmmHg  
PULSE/min DIAmmHg  
Each time the "M" button is pressed, the measured  
values are called from the latest ones.  
Alternating  
display  
SYSmmHg  
PULSE/min DIAmmHg  
Press the "M" button.  
SYSmmHg  
PULSE/min DIAmmHg  
Alternating  
display  
SYSmmHg  
PULSE/min DIAmmHg  
PULSE/min DIAmmHg  
* You can call the memory of up to twenty-one measurements.  
* The measurements made after the twenty-second measurement  
will be deleted from the oldest ones.  
 
12  
Memory Feature  
2. Press the START/STOP button to turn off the power.  
After reading the blood pressure values  
and pulse rate stored in the monitor,  
press the START/STOP button  
to turn off the power.  
SYSmmHg  
PULSE/min  
DIAmmHg  
* Even if you forget to turn off the power, the monitor will turn off  
automatically in approximately 2 minutes.  
* The stored measurements will remain in the memory even when  
The batteries are removed for battery replacement.  
• To delete the memory (Everything in the memory will be deleted.)  
Press the "M" button while the "M"  
SYSmmHg  
mark is displayed, then immediately  
hold down the START/STOP button  
for more than 2 seconds. (Pressing  
PULSE/min DIAmmHg  
the START/STOP button first will  
turn off the power.)  
Release the START/STOP button when  
the "M" mark starts to flash and wait  
until it finishes to flash.  
SYSmmHg  
PULSE/min DIAmmHg  
 
13  
Troubleshooting  
Symptom  
Cause  
What to do  
No display appears when  
the START/STOP  
button is pressed.  
Batteries are dead.  
Replace with new batteries  
Batteries were  
inserted incorrectly.  
Put the batteries in with  
the right (+) (-) orientation.  
Are you holding  
the wrist cuff at heart?  
Measure with the  
correct posture.  
Is the cuff wrapped  
snugly around the wrist?  
Wrap the wrist  
cuff correctly.  
Cannot measure  
or readings are too  
low (or high).  
Are your arms and  
shoulders tense?  
Relax and then measure.  
Have you been talking or  
Keep quiet while taking  
moving your hands during the measurement.  
measurement?  
When the START/ STOP  
button is pressed there  
is no pressure, but  
Turn power off once  
and restart measurement.  
You are in the previous  
reading mode. (memory)  
a reading appears.  
Blood pressure readings constantly vary with time  
of measurement and nervous condition. Take deep  
breaths to relax before measuring.  
Blood pressure is different  
each time. The reading is  
extremely low ( or high).  
If you cannot get correct measurement with the methods above, do not  
tamper with the internal mechanism. Contact Omron Healthcare  
customer service at 1.800.634.4350  
Occasionally, an individual’s physiological characteristics may cause too  
much error for measurement. In such a case, consult a medical specialist.  
14  
 
Troubleshooting  
When measurement is not being performed as normal, the following error  
messages may appear to indicate what is necessary for correct measurement.  
Error Display  
Causes  
What to do  
After several seconds  
Movement of  
arm or body or  
talking during  
measurement.  
Press the  
START/STOP  
button once  
turn off power.  
Sit still and  
restart measurement.  
After several seconds  
Vigorous  
movement  
of arm or  
body during  
measurement.  
The batteries  
are dead.  
Replace with  
new batteries.  
15  
 
FCC Caution  
Caution  
Changes or modifications not expressly approved by Omron Healthcare,  
Inc. could void the user’s authority ot operate this product.  
Note:  
POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only)  
This product has been tested and found to comply with the limits for a Class B digital  
device, pursuant to part 15 of the FCC rules.  
These limits are designed to provide reasonable protection against harmful interference  
in a residential installation. The product generates, uses, and can radiate radio frequency  
energy and, if not installed and used in accordance with the instructions, may cause harmful  
interference to radio communications. However, there is no guarantee that interference will  
not occur in a particular installation. If the product does cause harmful interference to radio  
or television reception, which can be determined by turning the product on and off, the user  
is encouraged to try to correct the interference by one or more of the following measure:  
• Reorient or relocate the receiving antenna  
• Increase the separation between the product and the receiver.  
• Connect the product into an outlet on a circuit different from that to which the receiver.  
• Consult the dealer or an experienced radio/TV technician for help.  
POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for Canada only)  
This digital apparatus does not exceed the Class B limits for radio emissions from digital  
apparatus as set out in the interference-causing equipment standard entitled “Digital  
Apparatus”, ICES-003 of the canadian Department of Communications.  
Cet appareil numerique respecte les linites de bruits radioelectriques applicables aux  
appareils numeriques de Classe B prescrites dans la norme sur le materiel brouileur:  
“Appareils Numeriques.” NMB-003 edictee par le ministre des communications.  
LICENSED UNDER U.S. PAT.  
4829419, 4942516, 4896260, 4531182, 4825364, 4686622, 4121284, 4396976, 4371923, 4471385,  
4120583, 4435732, 4739396  
16  
 
Care and Maintenance  
To protect your monitor from damage,  
please AVOID the following:  
Subjecting your monitor to extreme temperatures, humidity,  
and direct sunlight  
Washing or moistening the cuff  
Disassembling the monitor  
Subjecting the monitor to strong shocks (for example,  
dropping the monitor on the floor)  
Cleaning the monitor with volatile liquids. THE MONITOR SHOULD  
BE CLEANED WITH A SOFT, DRY CLOTH.  
17  
 
Limited Five Year Warranty  
Your Omron HEM-630 Ultra Compact Wrist Blood Pressure Monitor with  
Intellisense™ is warranted to be free from manufacturing defects for a period  
of five years under normal use. The five year warranty excludes the monitor  
cuff. The cuff is warranted for a one year period. This warranty extends  
only to the original retail purchaser.  
Should repair be needed within the warranty period, ship the unit prepaid  
to Omron Healthcare, Inc., 300 Lakeview Parkway, Vernon Hills, IL 60061,  
Attn: Service Dept., together with $5.00 for return shipping and insurance.  
Be sure to include the model number of your unit and your  
phone number on any correspondence.  
We will either repair or replace (at our option) free of charge any parts  
necessary to correct defects in the materials or workmanship.  
The above warranty is complete and exclusive. The warrantor expressly  
disclaims liability for incidental, special, or consequential damages  
of any nature. (Some states do not allow the exclusion or limitation  
of incidental or consequential damages, so the above warranty  
may not apply to you.)  
Any implied warranties arising by the operation of law shall be limited in duration  
to the term of this warranty. (Some states do not allow limitations on how long  
an implied warranty lasts, so the above limitation may not apply to you.)  
This warranty gives you specific legal rights and you may have other rights  
which vary from state to state. As a condition to operation of your warranty,  
the enclosed registration card must be completed and sent to us within  
10 days from the date of purchase.  
FOR CUSTOMER SERVICE CALL TOLL FREE:  
1-800-634-4350  
 
18  
Specifications  
Name:  
OMRON Automatic Blood Pressure Monitor  
Model:  
HEM-630  
Display:  
Digital display  
Measurement:  
Measurement Range:  
Oscillometric method  
Pressure; 0 to 280 mmHg  
Pulse rate; 40 to 200 beats/min  
Pressure; Within 4 mmHg  
Accuracy:  
Pulse rate; Within 5% of reading  
Automatic inflation by pumping  
Automatic rapid deflation  
Inflation:  
Deflation:  
Pressure Detection:  
Power Supply:  
Battery Life:  
Electrostatic capacity semiconductor pressure sensor  
Two AAA batteries (LR03)  
Approximately 400 measurements when using  
alkaline batteries at the room temperature of 22°C and  
by using three times a day and inflating to 170 mmHg  
+10°C to +40°C, 30 to 85% RH  
Operating Temperature  
and Humidity:  
Storage Temperature  
and Humidity:  
-20°C to +60°C, 10 to 95% RH  
135 to 215 mm  
Measurable  
Circumference of Wrist:  
Weight of Main Unit  
External Dimensions:  
Approximately 86 g (not including batteries)  
58 (W) x 49 (H) x 32 (D) mm  
(not including the wrist cuff)  
Electric Shock  
Protection:  
Internal power supply appliance type B  
Accessories:  
Storage case, two AAA alkaline batteries,  
Instruction manual  
* Please understand that specifications may be changed without prior notice.  
 
19  
Manufactured For:  
Omron Healthcare, Inc.  
300 Lakeview Parkway  
Vernon Hills, IL 60061  
Copyright © 7/2001 Omron Healthcare, Inc.  
630INST  
 

Miele Washer W5962 User Manual
Miller Electric Welder INTEGRA 201 241 User Manual
NDC comm Network Router NWE9251 User Manual
New Buck Corporation Indoor Fireplace CR8T User Manual
Olive Media Products Home Theater Server 4 User Manual
Onkyo Portable Speaker D 407C User Manual
Palm PDAs Smartphones Zire 71 User Manual
Panasonic Flat Panel Television Generation Plasma Display Television User Manual
Panasonic Network Card 2SC4691J User Manual
Panasonic Telephone KX TC1430W User Manual