Oregon Scientific Clock RMR603HGA User Manual

Wireless Thermo-Hygro Clock  
Model : RMR603HGA  
User Manual  
RMR603HGA lab test cover R2  
1
1/14/04, 1:31 AM  
 
INTRODUCTION  
ABOUT OREGON SCIENTIFIC  
Thank you for selecting the Oregon ScientificTM Wireless  
Thermo-Hygro Clock (RMR603HGA). This device  
bundles precise time keeping, alarm, and temperature  
and humidity monitoring features into a single tool you  
can use from the convenience of your home.  
more about other Oregon Scientific products such as  
digital cameras, hand-held organizers, health and fitness  
gear, and projection clocks. The website also includes  
contact information for our customer service department,  
in case you need to reach us.  
In this box, you will find:  
Main unit  
Remote sensor (THGR122NX)  
Keep this manual handy as you use your new product.  
It contains practical step-by-step instructions, as well  
as technical specifications and warnings you should  
know.  
2
RMR603HGA lab test R2  
2
1/17/04, 4:52 PM  
 
PRODUCT OVERVIEW  
FRONT VIEW  
1
1. SNOOZE / LIGHT: Press to activate backlight or  
snooze.  
2. Temperature Area: Readings, trend line, sensor  
reception status and channel number  
5
6
2
3
3. Humidity Area: Readings; trend line, and sensor  
battery status  
4. Clock / Alarm Area: Time, time zone, day of week,  
month, date, alarm and Atomic Clock reception  
status  
7
8
5.  
: Press to increase setting, activateAtomic Clock  
signal reception  
4
6
: Press to decrease setting  
9
7. MODE: Press to change display / settings  
8. MEM: Press to view current or saved max / min  
10  
temperature or humidity readings  
9. CHANNEL: Press to switch remote sensor  
10. ((.)): Press to view alarm settings  
3
RMR603HGA lab test R2  
3
1/17/04, 4:52 PM  
 
BACK VIEW  
1. Wall mount  
2. Battery compartment  
3. °C / °F switch  
1
2
4. ZONE: Press to switch time zones,  
deactivate Atomic Clock signal reception  
5. RESET hole  
6. Table stand  
3
4
5
6
4
RMR603HGA lab test R2  
4
1/17/04, 4:52 PM  
 
REMOTE SENSOR (THGR122NX)  
1
1
2
2
3
4
1. Wall mount hole  
2. RESET  
1. LCD display  
2. LED Status indicator  
3. Channel number (1 - 3)  
4. Battery compartment  
(Battery compartment cover not shown)  
5
RMR603HGA lab test R2  
5
1/17/04, 4:52 PM  
 
CHANGE SETTINGS  
GETTING STARTED  
BATTERIES  
1. Press and hold MODE for 2 seconds to enter setting  
mode.  
Batteries are not supplied with this product. You will need  
to purchase 2 x UM-3 (AA) 1.5V alkaline batteries for  
the main unit, and 2 x UM-4 (AAA) 1.5V alkaline batteries  
for the remote sensor.  
2. Press UP or DOWN to change settings.  
3. Press MODE to confirm.  
TABLE STAND OR WALL MOUNT  
Insert the stand on the back of the product, or mount it  
on a wall with a nail.  
Insert batteries before first use, matching the polarity as  
shown in the battery compartment. For best results,  
install batteries in the remote sensor before the main  
unit. Press RESET after each battery change.  
Do not use rechargeable batteries.  
NOTE  
shows when batteries are low.  
UNIT  
LOCATION  
Main  
Humidity Area when the  
INDOOR humidity is  
shown.  
REMOTE SENSOR (THGR122NX)  
Remote  
Humidity Area when the  
OUTDOOR humidity is  
shown.  
This product is shipped with a THGR122NX Thermo/  
Hygro Sensor that collects Temperature and Humidity  
data. Data can be collected from up to 3 sensors.  
Additional sensors sold separately.  
6
RMR603HGA lab test R2  
6
1/17/04, 4:52 PM  
 
For best results:  
SETUP SENSOR  
Insert the batteries and select the channel and  
temperature unit before you mount the sensor.  
Open the remote sensor battery compartment with a  
small Phillips screwdriver.  
Place the sensor out of direct sunlight and  
moisture.  
1. Insert the batteries, matching the polarity as shown  
in the battery compartment.  
Do not place the sensor more than 30 meters  
(98 feet) from the main (indoor) unit.  
2. Set the channel. The switch is located in the battery  
compartment.  
Position the sensor so that it faces the main  
(indoor) unit, minimizing obstructions such as  
doors, walls, and furniture.  
SWITCH  
Channel  
OPTION  
Place the sensor in a location with a clear view  
to the sky, away from metallic or electronic  
objects.  
Channel 1 - 3. If you are using  
more than one sensor, select a  
different channel for each sensor.  
Position the sensor close to the main unit  
during cold winter months as below-freezing  
temperatures may affect battery performance and  
signal transmission.  
3. Place the sensor near the main unit. Press RESET  
on the sensor to initiate signal sending between the  
sensor and the main unit. The reception icon on  
the main unit will blink for approximately 3 minutes  
while it is searching for the sensor. (Refer to the  
Sensor Data Transmission section for more  
information.)  
You may need to experiment with various locations to  
get the best results.  
4. Close the remote sensor battery compartment.  
5. Secure the sensor in the desired location using the  
wall mount or table stand.  
7
RMR603HGA lab test R2  
7
1/17/04, 4:52 PM  
 
DATA TRANSMISSION  
CLOCK  
Data is sent from the sensor(s) every 40 seconds.  
The reception icon shown in the Temperature and  
Humidity Areas shows the status.  
This product shows the current time, time zone, and day  
of week in English, Spanish, or French. The time is  
automatically updated by the US Atomic Clock in  
Boulder, Colorado unless you disable this feature.  
Signals are collected by the main unit when it is within  
1500 km (932 miles) of a signal.  
ICON  
DESCRIPTION  
Main unit is searching for  
sensors.  
At least 1 channel has  
been found.  
Channel 1 is selected (number  
will change depending on the  
sensor you select)  
Initial reception takes 2 - 10 minutes, and is initiated  
when you first setup the unit, and whenever you press  
RESET. Once complete, the reception icon will stop  
blinking. The icon is shown in the Clock Area.  
--- shows in Temp /  
Humidity Areas  
The selected sensor cannot  
be found. Search for the  
sensor or check batteries.  
SEARCH FOR SENSOR  
To search for a sensor, press and hold MEM and  
CHANNEL for 2 seconds.  
To force a manual search forAtomic Clock signals, press  
and hold UP for 2 seconds. If no signal is found, check  
the batteries.  
NOTE If the sensor is still not found, check the  
batteries, obstructions, and remote unit location.  
Signals from household devices such as  
NOTE  
doorbells, electronic garage doors, and home security  
systems may cause temporary reception failure. This is  
normal and does not affect general product performance.  
The reception will resume once the interference ends.  
8
RMR603HGA lab test R2  
8
1/17/04, 4:52 PM  
 
TURN ATOMIC CLOCK ON/OFF  
SWITCH CLOCK DISPLAY  
Perform this step if you cannot receive Atomic Clock  
signals. Press and hold ZONE for 2 seconds. Then,  
manually set the clock following the "Set Clock"  
instructions (below).  
Press MODE to toggle between Clock with Seconds,  
Clock with Weekday and Calendar.  
ALARM  
The signal icon indicates that the Atomic Clock  
feature is ON. No icon means that it is OFF  
This product is equipped with a 2-minute crescendo alarm  
and 8-minute snooze.  
SET CLOCK  
VIEW ALARM SETTINGS  
You only need to do this if you have disabled theAtomic  
Clock feature (for example, if you are too far from or  
cannot receive a signal).  
Press ((.)) . The Alarm Time and On/Off status will show  
in the Clock Area.  
SET ALARM  
1. Open the battery compartment.  
1. Press ((.)).  
2. Press ZONE repeatedly to display the desired Time  
Zone: (P) Pacific, (M) Mountain, (C) Central, or  
(E) Eastern.  
2. Press and hold ((.)) again for 2 seconds. TheAlarm  
settings will blink.  
3. Close the battery compartment.  
3. Select the hour and minute. Press UP or DOWN to  
change settings. Press ((.)) to confirm.  
4. Press and hold MODE for 2 seconds. The Clock  
Area will blink.  
5. Select the hour, minute, year, month, day and  
language. Press UP or DOWN to change the  
setting. Press MODE to confirm.  
NOTE  
The language options are (E) English,  
(F) French, and (S) Spanish.  
9
RMR603HGA lab test R2  
9
1/17/04, 4:52 PM  
 
ACTIVATE ALARM  
SELECT TEMPERATURE UNIT  
Slide the °C / °F switch into the desired location. The  
switch is located in the battery compartment. The setting  
for the main unit overrides the remote sensor setting.  
Press ((.)) to activate or deactivate the Alarm.  
in the Clock Area when the Alarm is activated.  
shows  
SNOOZE ALARM  
SELECT SENSOR CHANNEL  
Press SNOOZE/LIGHT to silence the Alarm for  
8 minutes.  
Press CHANNEL to switch between sensors 1 - 3.  
If no button is pressed, the Alarm will automatically  
silence after 2 minutes. It will then sound again after  
8 minutes.  
The icon shows the selected sensor.  
Kinetic-  
wave  
Icon  
TEMPERATURE AND HUMIDITY  
Designat-  
ed  
Display  
Remote Remote Remote  
Display Display Display  
Channel 1 Channel 2 Channel 3  
Indoor  
Display  
This product can display the following temperature and  
humidity information:  
Current, minimum and maximum readings  
Trend line  
To auto-scan between sensors, press and hold  
CHANNEL for 2 seconds. Each sensor's data will be  
displayed for 3 seconds. To end auto-scan, press  
CHANNEL or MEM.  
Data is collected by the remote sensors and displayed  
every 40 seconds.  
10  
RMR603HGA lab test R2  
10  
1/17/04, 4:52 PM  
 
NOTE  
If you use a sensor that collects only  
BACKLIGHT  
temperature data, humidity will not be shown.  
Press SNOOZE/LIGHT to activate the backlight for  
5 seconds.  
MINIMUM / MAXIMUM RECORDS  
Press MEM to toggle between current, maximum (MAX)  
and minimum (MIN) records for the selected sensor. To  
clear the records, press and hold MEM for 2 seconds.  
RESET SYSTEM  
The RESET buttons are located in the battery  
compartments for the main unit and sensors. Press  
RESET when you change the batteries and whenever  
performance is not behaving as expected (for example,  
unable to establish radio frequency link with remote  
sensor or radio-controlled clock).  
A beep will sound to confirm that the memory has been  
cleared.  
TEMPERATURE AND HUMIDITY TREND  
The trend lines are shown next to the Temperature and  
Humidity readings.  
NOTE  
When you press RESET, all settings will return  
to default value, and you will lose all stored information.  
Trend  
ICON  
Rising  
Steady  
Falling  
SAFETY AND CARE  
Clean the product with a slightly damp cloth and alcohol-  
free mild detergent.Avoid dropping the product or placing  
it in a high-traffic location.  
11  
RMR603HGA lab test R2  
11  
1/17/04, 4:52 PM  
 
WARNINGS  
TROUBLESHOOTING  
This product is designed to give you years of service if  
handled properly. Observe the following guidelines:  
Check here before contacting our customer service  
department.  
Problem  
Calendar  
Symptom  
Remedy  
Never immerse the product in water. This can  
cause electrical shock and damage the product.  
Change language  
Strange date /  
month  
(
9)  
Do not subject the main unit to extreme force,  
shock, or fluctuations in temperature or humidity.  
Clock  
Cannot adjust Disable Atomic Clock  
clock 9)  
(
Do not tamper with the internal components.  
Cannot auto- 1. Adjust batteries.  
synch 6)  
Do not mix new and old batteries or batteries of  
different types.  
(
2. Press RESET  
11)  
Do not use rechargeable batteries with this  
product.  
(
3. Manually activate  
Atomic Clock  
feature ( 9)  
Remove the batteries if storing this product for a  
long period of time.  
Do not scratch the LCD display.  
Temp  
Shows "LLL" Temperature is out-of-  
or "HHH" range  
Do not make any changes or modifications to this  
product. Unauthorized changes may void your right to  
use the product. The technical specification of this  
product and contents of this user guide are subject to  
change without notice. Images not drawn to scale.  
Remote  
sensor  
Cannot locate Check batteries ( 6)  
remote  
Check location ( 6)  
sensor  
Cannot  
change  
channel  
Check sensors. Only  
one sensor is  
working( 7)  
Data does  
not match  
main unit  
Initiate a manual sensor  
search ( 8)  
12  
RMR603HGA lab test R2  
12  
1/17/04, 4:52 PM  
 
REMOTE SENSOR (THGR122NX)  
SPECIFICATIONS  
RF frequency  
Range  
433 MHz  
MAIN UNIT DIMENSIONS  
30 meters (98 feet)  
with no obstructions  
L x W x H  
116 x 125 x 57 mm  
(4.57 x 4.92 x 2.24 inches)  
Transmission  
Channel No.  
Unit  
every 40 seconds  
1 - 3  
Weight  
7.90 ounces with battery  
°C or °F  
REMOTE SENSOR DIMENSIONS  
L x W x H  
92 x 60 x 20 mm  
(3.6 x 2.4 x .79 inches)  
CLOCK  
Atomic Clock  
Auto or manual  
(disabled)  
Weight  
2.22 ounces without battery  
Clock display  
Hour format  
Time zone  
HH:MM:SS  
12hr AM/PM  
TEMPERATURE  
Unit  
°C or °F  
-5 °C to 50 °C  
(23 °F to 122 °F)  
-20 °C to 60 °C  
(-4 °F to 140 °F)  
0.1 °C (0.2° F)  
Min / Max  
Pacific (P), Mountain (M),  
Central (C), or Eastern (E)  
Indoor Range  
Calendar  
Alarm  
MM/DD; weekday in  
3 languages (E, F, S)  
Outdoor Range  
2- minute crescendo  
Resolution  
Memory  
POWER  
Main unit batteries  
2 x UM-3 (AA) 1.5V  
alkaline  
RELATIVE HUMIDITY  
Range  
25% to 95%  
1%  
Sensor batteries  
2 x UM-4 (AAA) 1.5V  
alkaline  
Resolution  
Memory  
Min / Max  
13  
RMR603HGA lab test R2  
13  
1/17/04, 4:52 PM  
 
Reorient or relocate the receiving antenna.  
FCC STATEMENT  
Increase the separation between the equipment  
and receiver.  
This device complies with Part 15 of the FCC Rules.  
Operation is subject to the following two conditions:  
(1) This device may not cause harmful interference, and  
(2) This device must accept any interference received,  
including interference that may cause undesired  
operation.  
Connect the equipment into an outlet on a circuit  
different from that to which the receiver is  
connected.  
Consult the dealer or an experienced radio/TV  
technician for help.  
Warning: Changes or modifications to this unit not  
expressly approved by the party responsible for  
compliance could void the user's authority to operate  
the equipment.  
NOTE: This equipment has been tested and found to  
comply with the limits for a Class B digital device,  
pursuant to Part 15 of the FCC Rules. These limits are  
designed to provide reasonable protection against  
harmful interference in a residential installation. This  
equipment generates, uses and can radiate radio  
frequency energy and, if not installed and used in  
accordance with the instructions, may cause harmful  
interference to radio communications.  
However, there is no guarantee that interference will not  
occur in a particular installation. If this equipment does  
cause harmful interference to radio or television  
reception, which can be determined by turning the  
equipment off and on, the user is encouraged to try to  
correct the interference by one or more of the following  
measures:  
14  
RMR603HGA lab test R2  
14  
1/17/04, 4:52 PM  
 
is in conformity with Part 15 of the FCC Rules. Operation  
is subject to the following two conditions:  
DECLARATION OF CONFORMITY  
The information below is not to be used as contact for  
support or sales. Please call our customer service number  
the warranty card for this product) for all inquiries instead.  
1) This device may not cause harmful  
interference.  
2) This device must accept any interference  
received, including interference that may  
cause undesired operation.  
We  
Name:  
Oregon Scientific, Inc.  
Address:  
19861 SW 95th Place,  
Tualatin, Oregon 97062 USA  
Telephone No.:  
Fax No.:  
1-800-853-8883  
1-503-684-8883  
declare that the product  
Product No.:  
RMR603HGA  
Product Name:  
Manufacturer:  
Address:  
Wireless Thermo-Hygro Clock  
IDT Technology Limited  
Block C, 9/F, Kaiser Estate,  
Phase 1, 41 Man Yue St.,  
Hung Hom, Kowloon,  
Hong Kong  
15  
RMR603HGA lab test R2  
15  
1/17/04, 4:52 PM  
 
© 2004 Oregon Scientific. All rights reserved.  
P/N.: 086-003347-01  
RMR603HGA lab test back cover  
1
12/29/03, 10:29 PM  
 

Miele Clothes Dryer T1526 User Manual
Milwaukee Saw 6230N User Manual
Mr Heater Electric Heater HS35LP User Manual
Multiquip Chainsaw WM 90P User Manual
NETGEAR Switch NETGEAR User Manual
NordicTrack Exercise Bike NTEL75060 User Manual
North Star Pressure Washer M1573001K1 User Manual
Oricom Radio UHF080 User Manual
Panasonic Network Card 2SA2174J User Manual
Panasonic Telephone KX T2375ALW User Manual