TREVISO Sleek Weather Station
Model: BAR988HGA / BAR986HGA
USER MANUAL
BAR988HGA English Cover R5
1
9/18/04, 2:55 AM
Backlight ................................................................. 22
Reset System ......................................................... 22
Safety and Care ...................................................... 22
Warnings ................................................................. 22
Troubleshooting ..................................................... 23
Specifications ......................................................... 23
About Oregon Scientific ........................................ 25
FCC Statement ....................................................... 25
Declaration of Conformity .................................... 26
2
BAR988HGA English R5
2
9/18/04, 3:00 AM
Keep this manual handy as you use your new product.
It contains practical step-by-step instructions, as well
as technical specifications and warnings you should
know.
INTRODUCTION
Thank you for selecting the Oregon ScientificTM
BAR988HGA / BAR986HGA TREVISO Sleek Weather
Station. This powerful device bundles time keeping,
weather monitoring, indoor and outdoor temperature and
humidity readings, barometric trends and altitude
adjustment, into a single tool you can use from the
convenience of your home.
In this box, you will find:
•
•
•
•
•
Main unit
Remote sensor (RTGR328NA)
Optional UV sensor (UVR138A)
6V AC adapter
Batteries
BAR988HGA--- BAR988HGAMain Unit + RTGR328NA
Remote Sensor
BAR986HGA--- BAR988HGAMain unit + RTGR328NA
Remote Sensor + UVR138A UV Sensor
The THGR328N (5-Channel) and THGR268
NOTE
(3-Channel) remote sensors are also compatible with
this weather station. Additional sensors are sold
separately. Please contact your local retailer for more
information.
3
BAR988HGA English R5
3
9/18/04, 3:00 AM
PRODUCT OVERVIEW
FRONT VIEW
1. LCD display
2. MODE: Change settings / display
1
2
3. MEMORY: View current, maximum and minimum
temperature / humidity / UV readings
7
4. HISTORY: View historical barometer and UV
readings
3
4
5
5. ALARM / : View alarm status; set alarm
8
6. SNOOZE / LIGHT: Activate 8-minute snooze or
backlight
7. SELECT: Switch Areas
9
8. CHANNEL: Switch remote sensor display
9. UP: Increase setting / activate atomic clock
10. DOWN: Decrease setting / deactivate atomic clock
10
6
4
BAR988HGA English R5
4
9/18/04, 3:00 AM
BACK VIEW
1. Ventilation holes
2. Battery compartment (bottom)
3. AC adaptor socket
1
4. °C / °F switch (in battery compartment)
5. RESET button (in battery compartment)
6. mb / inHg switch (in battery compartment)
You can adjust the angle of the clock display as
shown below:
3
2
4
5
6
5
BAR988HGA English R5
5
9/18/04, 3:00 AM
LCD DISPLAY
1. Weather ForecastArea: Animated weather forecast
2. Temperature / Humidity / Comfort Zone Area:
Readings and trend lines; comfort zone; sensor
channel number
3. UVI / Barometer Area: UV level and barometric
pressure bar chart; UV Index and barometric
readings
1
4. Clock / Alarm / Calendar Area: Atomic clock;
alarms; calendar
2
3
4
6
BAR988HGA English R5
6
9/18/04, 3:00 AM
Weather Forecast Area
Temperature / Humidity / Comfort Zone Area
6
7
1
2
1
2
8
9
3
4
5
10
11
3
1. Selected Area icon
2. Temperature trend
3. Channel number (1-5) / reception status
4. Low battery icon for remote sensor
5. Humidity trend
1. Low battery icon for main unit
2. AC adaptor icon - displays when unplugged
3. Weather display
6. MAX / MIN temperature
7. Temperature - °C / °F
8. Heat Index
9. MAX / MIN humidity
10. Humidity
11. Comfort levels
7
BAR988HGA English R5
7
9/18/04, 3:00 AM
UVI / Barometer Area
Clock / Alarm / Calendar Area
1
2
1
3
6
7
2
3
8
4
5
4
5
1. Pre-Alarm is set
9
10
11
2. Pre-Alarm display / Pre-Alarm setting
3. Channel with atomic clock reception is locked
4. Atomic clock reception icon
5. Daily Alarm is set
12
6
7
1. Barometric pressure is showing
2. UV is showing
6. Offset time-zone
7. Time / date / calendar
3. Low battery icon for UV sensor
4. UVI value is showing
5. UV exposure time countdown has started
6. UV index level
7. UV exposure time for user
8. Barometer / UV chart
9. SPF applied to user for UV exposure
10. User skin type for UV exposure
11. User no. (for UV Mode) or hour history for UV /
Barometric pressure reading
12. Altitude / barometric pressure / UVI reading
8
BAR988HGA English R5
8
9/18/04, 3:00 AM
REMOTE SENSOR (RTGR328NA)
5
1
2
1
2
3
4
6
7
8
1. Signal reception
2. US time zone
3. Channel number
4. Low battery icon
5. Time
3
6. Temp (°C or °F)
7. Humidity %
1. LCD display
2. LED status indicator
3. Ventilation duct
8. Temp / Humidity
9
BAR988HGA English R5
9
9/18/04, 3:00 AM
GETTING STARTED
BATTERIES
Batteries are supplied with this product:
1
•
•
Main unit
4 x UM-4 (AAA) 1.5V
2 x UM-3 (AA) 1.5V
2
3
4
5
Remote unit
Insert batteries before first use, matching the polarity as
shown in the battery compartment. For best results,
install batteries in the remote sensor before the main
unit. Press RESET after each battery change.
6
7
To install the main unit batteries:
8
1. Wall mount
2. CHANNEL switch (1-5)
3. RESET
4. °C / °F
5. SEARCH
Do not use rechargeable batteries.
NOTE
6. ZONE
shows when batteries are low.
7. Battery compartment
8. Fold-out stand
10
BAR988HGA English R5
10
9/18/04, 3:00 AM
NOTE It is recommended that you use alkaline
batteries with this product for longer performance.
CHANGE SETTINGS
1. Press SELECT to switch between Areas.
indicates the selected Area.
UNIT
LOCATION
Main
Weather Forecast Area
Temperature / Humidity Area
UVI / Barometric Pressure Area
Remote
UV Sensor
NOTE The UV Sensor is an optional item.
AC ADAPTOR (MAIN UNIT)
The batteries serve as a back-up power supply. For
continuous use, please install theAC adaptor at the base
of the unit:
2. Most Areas have alternate display options
(for example, Clock / Alarm or Barometer / UVI).
Press MODE to switch options, or ALARM /
switch between clock and alarm.
to
3. Press and hold MODE for 2 seconds to enter setting
mode.
4. Press UP or DOWN to change settings.
5. Press MODE to confirm.
REMOTE SENSOR
This product is shipped with the RTGR328NA Thermo /
Hygro Sensor. The main unit can collect data from up to
6 sensors (5 Thermo / Hygro Sensors and 1 UV Sensor).
The THGR328N and THGR268 sensors are also
compatible with this weather station. (Additional sensors
are sold separately. Contact your local retailer for more
information.)
shows in the Weather Forecast Area when the AC
adapter is not plugged in.
11
BAR988HGA English R5
11
9/18/04, 3:00 AM
The RTGR328NA Sensor collects and transmits
temperature and humidity information, along with time
and date information. Time and date information is
obtained by synchronizing with radio broadcasted atomic
clock information from the National Institute of Time
located in Boulder Colo. For more information on
the Atomic Clock, pleasit www.nist.gov
To fold out the stand:
1
2
SET UP THERMO / HYGRO SENSOR (RTGR328N)
1. Open the battery compartment with a small Phillips
screwdriver.
2. Insert the batteries.
For best results:
3. Set the channel and radio signal format. The switches
are located in the battery compartment.
•
Insert the batteries and select the unit, channel, and
US time zone before you mount the sensor.
SWITCH
OPTION
•
•
Place the sensor out of direct sunlight and moisture.
Channel
If you are using more than one
sensor, select a different channel
for each sensor.
Do not place the sensor more than 230 feet
(70 meters) from the main (indoor) unit.
•
Position the sensor so that it faces the main (indoor)
unit, minimizing obstructions such as doors, walls,
and furniture.
4. Press RESET. Then set the temperature unit.
SWITCH
OPTION
•
•
Place the sensor in a location with a clear view to
the sky, away from metallic or electronic objects.
Temp
°C / °F
Position the sensor close to the main unit during cold
winter months as below-freezing temperatures may
affect battery performance and signal transmission.
5. Press ZONE to select the US time zone (P for Pacific,
M for Mountain, C for Central or E for Eastern).
6. Close the battery compartment.
12
BAR988HGA English R5
12
9/18/04, 3:00 AM
NOTE The transmission range may vary and is subject
to the receiving range of the main unit.
SEARCH FOR SENSOR
To search for a Thermo / Hygro sensor, press SELECT
to navigate to the Temperature / Humidity Area. will
show next to the Area. Then, simultaneously press and
You may need to experiment with various locations to
get the best results.
hold MEMORY and CHANNEL for 2 seconds.
SENSOR DATA TRANSMISSION
To search for the UV sensor, press SELECT to navigate
to the UVI / Barometer Area. will show next to the
Area. Then, press and hold MEMORY and CHANNEL
Data is sent from the sensor(s) every 60 Seconds. The
reception icon shown in the Temperature / HumidityArea
indicates the status.
for 2 seconds. (The UV sensor is an optional item.)
ICON
DESCRIPTION
NOTE
batteries.
If the sensor is still not found, check the
Main unit is searching
for sensors.
At least 1 channel has
been found.
CLOCK AND CALENDAR
This product tracks the time and date based on US
atomic clock signals from the RTGR328NA remote
sensor, or manual settings that you enter.
Sensor 1 is sending
data. (The number
shows which sensor is
selected.)
--- shows in Temp /
Humidity Area
The selected sensor
cannot be found.
Search for the sensor
or check batteries.
13
BAR988HGA English R5
13
9/18/04, 3:00 AM
ATOMIC CLOCK
ICON
MEANING
The RTGR368NA remote sensor collects time and
temperature information and transmits this back to the
main unit. The current time and date is received by radio
signal from theAtomic Clock broadcast located in Boulder,
Colorado. For more information on the Atomic Clock,
The unit has lost contact with the
remote sensor but the time is
synchronized.
The unit has lost contact with the
remote sensor and the time is not
synchronized.
The unit cannot reach the remote
sensor.
Initial reception takes 2-10 minutes, and is initiated when
you first set up the unit, and whenever you press RESET.
Once complete, the reception icon will stop blinking.
To force a manual search for atomic clock
NOTE
reception, press and hold SEARCH on the sensor
(RTGR328NA) for 2 seconds.
The
icon shown in the Clock Area indicates
2 factors:
TURN ATOMIC CLOCK ON / OFF
If you wish to manually set the clock, you must first
disable the atomic clock feature. To do this, navigate to
the Clock / Alarm Area. Then, press and hold DOWN on
the main unit for 2 seconds. To enable it, navigate to the
Clock / Alarm Area, then press and hold UP for
2 seconds.
•
•
Connection between the main unit and the sensor
that collects atomic clock signals (
)
Atomic clock signal reception (
)
How these signals work together:
ICON
MEANING
Atomic clock enabled:
The unit has contact with the
sensor and has synchronized the
time.
The unit has contact with the
sensor but the time has not been
synchronized.
14
BAR988HGA English R5
14
9/18/04, 3:00 AM
Atomic clock disabled:
NOTE
The language options are (E) English,
(F) French, (D) German, (I) Italian, and (S) Spanish. The
language you select determines the weekday display.
SWITCH CLOCK DISPLAY
Press SELECT to navigate to the Clock Area.
show next to the Area.
will
SET CLOCK
The BAR988HGA / BAR986HGA and the RTGR368NA
should automatically set and update the time, as
necessary. However, if you are too far away from an
Atomic Clock broadcast signal, or the product is unable
to synchronize with the broadcast due to interference,
you may need to set the clock manually.
Press MODE to toggle between:
•
•
•
•
Clock with seconds
Clock with day
Clock with time-zone offset
Calendar
1. Press SELECT to navigate to the Clock Area.
will show next to the Area.
2. Press and hold MODE for 2 seconds.
ALARMS
3. Select the time zone offset hour (+ / -23 hours),
12 / 24 hour format, hour, minute, year, date / month
format, month, date and display language.
This product has 2 alarms: The Daily Alarm and a
Pre-Alarm for snowy weather. The Daily Alarm can be
set to go off at the same time every day. The Pre-Alarm
sounds only when the Daily Alarm is activated and the
recorded temperature from Channel 1 Sensor falls to
35.6°F (2°C) or below.
4. Press UP or DOWN to change the setting.
5. Press MODE to confirm.
NOTE If no time zone hour offset is set, the time shown
will be Pacific Time. To change to another US time zone,
select an hour offset accordingly. The time zone options
and their related hour offset times are Pacific (-8),
Mountain (-7), Central (-6) and Eastern (-5).
SET DAILY ALARM
1. Press SELECT to navigate to the Clock Area.
will show next to the Area.
15
BAR988HGA English R5
15
9/18/04, 3:00 AM
2. Press ALARM / to view the alarm. (AL will show
at the top.)
5. Press ALARM / to confirm.
3. Press and hold ALARM / for 2 seconds.
shows when the Pre-Alarm is set.
4. Select the hour and minute. Press UP or DOWN to
change settings.
NOTE
The Daily Alarm will NOT function until the next
day if the Pre-Alarm has been triggered. Also, if you
deactivate the Daily Alarm, the Pre-Alarm is
automatically deactivated.
5. Press ALARM / to confirm.
6. The Daily Alarm icon will appear when the alarm
is set.
ACTIVATE ALARM
SET PRE-ALARM
Navigate to the Clock Area, then press ALARM / to
switch to Daily Alarm or Pre-Alarm view. To activate or
deactivate the alarm, press UP or DOWN.
The Pre-Alarm can be set to sound 15, 30, 45, or
60 minutes before the DailyAlarm. It will sound whenever
the recorded temperature from Channel 1 Sensor falls
to 35.6°F (2°C) or below.
When the alarm time is reached, the backlight will be on
for 8 seconds and crescendo alarm will sound for
2 minutes. Press any key (except snooze) to silence
the alarm. It will sound at the same time the next day.
For example, if you set the alarm to 7:00 AM, and the
Pre-Alarm to 45 minutes, the Pre-Alarm will sound at
6:15 AM provided the outdoor temperature at Channel
1 Sensor is 35.6°F (2°C) or below.
SNOOZE
Press SNOOZE / LIGHT to temporarily disable the alarm
for 8 minutes. or will blink while snooze is on.
1. Set up and activate the Daily Alarm.
2. Press ALARM / to switch to Pre-Alarm view.
(PRE-AL will show at the top.)
3. Press and hold ALARM / for 2 seconds.
BAROMETER
4. Press UP or DOWN to select 15, 30, 45 or
60 minutes. This is the amount of time the Pre-Alarm
will sound BEFORE the Daily Alarm. The Pre-Alarm
is automatically activated when you select a time.
This product tracks fluctuations in barometric pressure
to provide the weather forecast, and the current and past
24 hours barometric pressure history measurements are
recorded by the main (indoor) unit.
16
BAR988HGA English R5
16
9/18/04, 3:00 AM
VIEW BAROMETER AREA
Press SELECT to navigate to the Barometer Area.
If
is NOT shown, press MODE.
Barometric data is shown in 2 areas at the bottom of the
display. The upper area shows a 24-hour bar chart.
The lower area shows current and historical readings.
BAR CHART DISPLAY
The bar chart visually shows atmospheric changes from
the current hour (0) to 24 hours prior (-24).
SELECT MEASUREMENT UNIT
Slide the mb / inHg switch (in the clock battery
compartment), to change the display unit.
SET ALTITUDE
Set the altitude to match how far above or below sea
level you are living. This ensures that the barometric
pressure readings are accurate.
VIEW BAROMETER HISTORY
Navigate to the Barometer Area. Then press HISTORY
repeatedly to scroll through the measurements. The
number shown in the HR box indicates how long ago
each measurement was taken (e.g. 2 hours ago, 3 hours
ago, etc.).
1. Navigate to the Barometer Area.
2. Press and hold HISTORY for 2 seconds.
17
BAR988HGA English R5
17
9/18/04, 3:00 AM
3. Press UP or DOWN to set the altitude in 33-foot
increments (-328 ft to 8202 ft).
ICON
DESCRIPTION
Cloudy
4. Press HISTORY to confirm.
Rainy
WEATHER FORECAST
This product forecasts the next 12 to 24 hours of weather
within a 19-31 mile (30-50 km) radius. The forecast is
based on barometric pressure trend readings.
Snowy
NOTE The night time icon displays from 6 PM to 6AM.
When the Channel 1 Sensor records a temperature of
35.6°F (2°C) or lower, the RAINY icon becomes SNOWY.
The top area shows an animated icon indicating the
forecasted weather.
UV MEASUREMENT - OPTIONAL SENSOR
WEATHER FORECAST ICONS
The UVR138AUltra-Violet Radiation Sensor is included
with the BAR986HGA and is available as an optional
item for the BAR988HGA. The UV sensor gives you the
following information at your fingertips:
ICON
DESCRIPTION
Clear
•
•
10-hour Ultra-Violet Index (UVI) record.
Day / Night
Day / Night
Automatic calculation of acceptable UV exposure
times based on pre-set user profiles (4 users
maximum).
Partly cloudy
•
UVI Danger Alert when UV Index reaches unsafe
levels.
18
BAR988HGA English R5
18
9/18/04, 3:00 AM
2. Press CHANNEL to select user 1-4.
UV data is shown in the same area as the Barometer.
Press SELECT to navigate to the Barometer Area, then
3. Press and hold MODE for 2 seconds to enter the
Skin Type Setting Mode of the selected user.
press MODE to display the UV icon
and data.
4. Press UP or DOWN to choose 1 of the 4 skin type
settings. Then press MODE to confirm and enter the
SPF Set Up Mode.
NOTE Refer to the UVR138A User Manual for more
information and see below to learn about the new
additional UV features.
5. Press UP or DOWN to increase or decrease the SPF
value. Then press MODE to confirm and enter the
UV Exposure Time Countdown Setting Mode.
NEW ADDITIONAL UV FEATURES
UV EXPOSURE TIME COUNTDOWN
6. Press UP or DOWN to enable or disable countdown.
Press MODE to exit the UV Exposure Time
Countdown Mode and start the exposure time
countdown. The remaining user UV exposure time
To set the exposure time countdown you need set to the
Skin Type and Sun Protection Factor (SPF) as follows:
will display and the
will flash.
1. Press SELECT to navigate to the Barometer Area,
then press MODE to select the UV display.
7. When the countdown has reached "0", an alarm will
sound for 2 minutes. Press any button to turn the
alarm off. The icon will flash for 2 minutes even
if you have stopped the alarm sound.
MAXIMUM / MINIMUM MEMORY FOR UVI
To view the maximum and minimum memory for UVI:
1. Press SELECT to navigate to the Barometer Area.
2. Press MODE to select the UV display.
3. Press MEMORY to show maximum, minimum and
current UVI readings.
4. Press and hold MEMORY for 2 seconds to clear the
UVI memory.
19
BAR988HGA English R5
19
9/18/04, 3:00 AM
NOTE The UV sensor must be activated before you
try and set the additional features. Please refer to the
UVR138A User Manual for more information.
SELECT MEASUREMENT UNIT
Slide the °C / °F switch (inside the clock battery
compartment), to the setting you want.
SELECT SENSOR CHANNEL
TEMPERATURE AND HUMIDITY
Press CHANNEL to switch between sensors 1-5.
The weather station can display the following information
from any of the 5 remote sensors:
•
•
Current, minimum, and maximum temperatures and
relative humidity percentages.
Comfort level indicator and trend line (rising, falling,
or steady).
The house icon shows the selected remote sensor.
•
•
To auto-scan between sensors, press and hold
CHANNEL for 2 seconds. Each sensor's data will
be displayed for 3 seconds.
Data is collected and displayed approximately every
60 seconds.
To end auto-scan, press CHANNEL or MEMORY
with the Temperature / Humidity Area selected.
VIEW TEMPERATURE AND HUMIDITY AREA
Press SELECT to navigate to the Temperature and
Humidity Areas.
If you select a sensor that collects only
NOTE
temperature data, the humidity will not be shown.
Temperature data is given at the top; Humidity is below.
MINIMUM / MAXIMUM RECORDS
•
Press MEMORY repeatedly to view current,
maximum and minimum records for the selected
sensor.
•
To clear the records, press and hold MEMORY for
2 seconds. A beep will sound to confirm that the
memory has been cleared.
20
BAR988HGA English R5
20
9/18/04, 3:00 AM
TEMPERATURE AND HUMIDITY TREND
HEAT INDEX
The trend lines are shown next to the temperature and
humidity readings.
The Heat Index advises 4 levels of warning if the
temperature is high.
TREND
RISING
STEADY FALLING
DANGER
CATEGORY
TEMPERATURE
TEMPERATURE
°F
°C
>54.5
Extreme Danger >130
Danger
105-130
40.5-54.4
32.2-40.5
HUMIDITY
Extreme
Caution
90-105
Caution
80-90
26.6-32.2
COMFORT ZONE
To display the Heat Index:
The Comfort Zone indicates how comfortable the climate
is, based on current temperature and humidity
measurements.
1. Press SELECT to navigate to the TemperatureArea.
will show next to the Area.
ZONE
WET
TEMPERATURE HUMIDITY
2. Press MODE to reach the Heat Index display.
Any
>70%
3. Press CHANNEL to select the desired channel.
68-77°F
(20-25°C)
COM
40-70%
NOTE
If the temperature is below 80°F / 26°C, or the
desired channel is not working, the Heat Index will
display "NA".
Any
DRY
<40%
NOTE This information is shown in the Humidity Area
when the current measurement is displayed.
21
BAR988HGA English R5
21
9/18/04, 3:00 AM
BACKLIGHT
WARNINGS
Press SNOOZE / LIGHT to illuminate the backlight for
8 seconds.
This product is designed to give you years of service if
handled properly. Oregon Scientific will not be
responsible for any deviations in the usage of the device
from those specified in the user instructions or any
unapproved alterations or repairs of the product.
Observe the following guidelines:
RESET SYSTEM
The RESET button is located at the bottom of the unit.
Press RESET when you change the batteries and
whenever performance is not behaving as expected (for
example, unable to establish radio frequency link with
remote unit or radio-controlled clock).
•
•
Never immerse the product in water. This can
cause electrical shock and damage the product.
Do not subject the main unit to extreme force,
shock, or fluctuations in temperature or humidity.
•
•
Do not tamper with the internal components.
NOTE
When you press RESET, all settings will return
to default value, and you will lose all stored information.
Do not mix new and old batteries or batteries of
different types.
•
•
•
Do not use rechargeable batteries with this
product.
SAFETY AND CARE
Remove the batteries if storing this product for a
long period of time.
Clean the product with a slightly damp cloth and alcohol-
free, mild detergent. Avoid dropping the product or
placing it in a high-traffic location.
Do not scratch the LCD display.
NOTE The technical specification of this product and
contents of this user guide are subject to change without
notice. Images not drawn to scale.
22
BAR988HGA English R5
22
9/18/04, 3:00 AM
TROUBLESHOOTING
SPECIFICATIONS
Main Unit Dimensions
PROBLEM
SYMPTOM
REMEDY
L x W x H
4.72 x 3.39 x 7.40 inches
(120 x 86 x 188 mm)
Barometer
Strange
readings
Set altitude / unit
(→ 17)
Weight
0.83 lbs (376 grams)
without battery
Calendar
Clock
Strange
date /
month
Change language
(→ 15)
Remote Unit Dimensions
Cannot
adjust
clock
Disable atomic
clock (→ 14)
L x W x H
2.76 x 0.96 x 4.57 inches
(70 x 24.5 x 116 mm)
Weight
0.24 lbs (108 grams)
without battery
Cannot
auto-synch
1. Adjust
batteries (→ 10)
2. Press RESET
(→ 22)
Temperature
Unit
°F or °C
3. Manually
activate atomic
clock (→ 14)
Indoor Range
23 °F to 122 °F
(-5 °C to 50 °C)
Outdoor Range
-4 °F to 140 °F
(-20 °C to 60 °C)
Temp
Shows
"LLL" or
"HHH"
Temperature is
out-of-range
Resolution
Comfort
0.2 °F (0.1 °C)
68 °F to 77 °F
(20 °C to 25 °C)
Remote
sensor
Cannot
locate
Check batteries
(→ 12)
Memory
Min / Max
remote
sensor
Relative Humidity
Range
25% to 95%
1%
Resolution
23
BAR988HGA English R5
23
9/18/04, 3:00 AM
Comfort
Memory
40% to 70%
Min / max
Calendar
DD / MM or MM / DD;
Day of the week in 1 of
5 languages (E, G, F, I, S)
Alarm
Daily & Pre-Alarm;
2-minute crescendo
Barometer
Unit
mb / hPa or inHg
1 mb (0.03 inHg)
Snooze
Power
8-minute snooze
Resolution
Altitude
-328 to 8202 feet
(-100 to 2500 meters)
Display
Sunny (day / night),
partly cloudy (day /
night), cloudy, rainy,
snowy
Main Unit
Power adapter
Batteries
6V AC adapter
4 x UM-4 (AAA) 1.5V
Remote Unit (RTGR328NA)
RF frequency
Thermo / Hygro Remote Unit
433 MHz
Batteries
2 x UM-3 (AA) 1.5V
Range
Up to 230 feet (70 meters)
with no obstructions
NOTE It is recommended that you use alkaline
batteries with this product for longer performance.
Transmission
Channel No.
Unit
Approx. every 1 minute
1, 2, 3, 4 or 5
°C or °F
Atomic Clock
Synchronization
Clock display
Hour format
Auto or disabled
HH:MM:SS
12hr AM / PM or 24hr
24
BAR988HGA English R5
24
9/18/04, 3:00 AM
ABOUT OREGON SCIENTIFIC
FCC STATEMENT
more about Oregon Scientific products such as digital
cameras; MP3 players; children's electronic learning
products and games; projection clocks; health and
fitness gear; weather stations; and digital and conference
phones. The website also includes contact information
for our customer care department in case you need to
reach us, as well as frequently asked questions and
customer downloads.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
his device must accept any interference received,
including interference that may cause undesired
operation.
WARNING Changes or modifications to this unit not
expressly approved by the party responsible for
compliance could void the user's authority to operate
the equipment.
We hope you will find all the information you need on
our website, however if you'd like to contact the Oregon
Scientific Customer Care department directly, please
visit:
This equipment has been tested and found to
NOTE
comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications.
www2.oregonscientific.com/service/support
OR
Call 949-608-2848 in the US.
For international enquiries, please visit:
However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does
cause harmful interference to radio or television
reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following
measures:
www2.oregonscientific.com/about/international/
default.asp
25
BAR988HGA English R5
25
9/18/04, 3:00 AM
•
•
Reorient or relocate the receiving antenna.
declare that the product
Product No.:
Increase the separation between the equipment and
receiver.
BAR988HGA / BAR986HGA
TREVISOSleekWeatherStation
IDT Technology Limited
Product Name:
Manufacturer:
Address:
•
•
Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
Block C, 9/F, Kaiser Estate,
Consult the dealer or an experienced radio / TV
technician for help.
Phase 1, 41 Man Yue St.,
Hung Hom, Kowloon,
DECLARATION OF CONFORMITY
Hong Kong
The information below is not to be used as contact for
support or sales. Please call our customer service number
the warranty card for this product) for all inquiries instead.
is in conformity with Part 15 of the FCC Rules. Operation
is subject to the following two conditions:
1) This device may not cause harmful interference.
his device must accept any interference
received, including interference that may cause
undesired operation.
We
Name:
Oregon Scientific, Inc.
19861 SW 95th Place,
Tualatin, Oregon 97062 USA
1-800-853-8883
Address:
Telephone No.:
Fax No.:
1-503-684-8883
26
BAR988HGA English R5
26
9/18/04, 3:00 AM
© 2004 Oregon Scientific. All rights reserved.
086-000000-000
BAR988HGA English Back R5
1