Pelco Camera Accessories MRD1400HZ16 User Manual

®
01215  
MRD1400HZ16  
Camera Control  
Interface for the  
CC1400HZ16  
Installation/  
Operation Manual  
C1973M-B (8/03)  
In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150  
International Customers: Tel +1(559) 292-1981 • FAX +1(559) 348-1120  
 
IMPORTANT SAFEGUARDS AND WARNINGS  
Prior to installation and use of this product, the following WARNINGS should be observed.  
1. Installation and servicing should only be done by qualified service personnel and con-  
form to all local codes.  
2. There are no user-serviceable parts inside this unit. Only authorized service personnel  
may open the unit.  
3. To reduce the risk of fire or electric shock, do not expose this unit to rain or moisture if  
this unit is designed for indoor use only.  
The product and/or manual may bear the following marks:  
This symbol indicates that dangerous volt-  
age constituting a risk of electric shock is  
present within this unit.  
C A U T I O N :  
RISK OF ELECTRIC SHOCK.  
DO NOT OPEN.  
This symbol indicates that there are impor-  
tant operating and maintenance instructions  
in the literature accompanying this unit.  
Please thoroughly familiarize yourself with the information in this manual prior to installation  
and operation.  
Pelco Manual C1973M-B (8/03)  
3
 
DESCRIPTION  
The MRD1400HZ16 is a camera interface control for Pelco’s CC1400HZ16 Series digital  
color camera. The unit can be mounted directly to a wall or installed in a DF5 Series dome,  
DF8A Series dome, EH2512 Series enclosure, or EH3512 Series enclosure.  
The MRD1400HZ16 can be used with the following Pelco controllers and matrix switchers:  
Controllers (direct mode only)  
MPT9500, CM9760-KBD Series, KBD200A,  
and KBD300A  
Matrix Switchers  
(configured for D or P protocols only)  
CM6700 Series, CM6800 Series, CM9740  
Series, and CM9760 Series  
INSTALLATION  
The following items are supplied:  
Qty. Item  
1
1
1
1
1
4
1
1
MRD1400HZ16  
DF5/DF8/EH2512 Series adapter  
EH3500 Series adapter  
4-pin connector  
Data cable (12 inches)  
4-40 Phillips button head screws  
#10 nut and washer  
Camera sled for EH3500 Series enclosure  
DIP SWITCH SETTINGS  
NOTE: Baud/Address  
Settings – If switch settings  
are changed while the power  
to the MRD unit is ON, push  
and hold the reset button for  
five seconds and then  
BAUD RATE SELECTION  
The baud rate must be set for the MRD1400HZ16 to automatically sense D or P protocol.  
The default communication rate for the MRD1400HZ16 is 4800 baud. If the system’s control-  
ler/switcher uses a different communication rate, change the baud rate of the  
MRD1400HZ16 to match the controller/switcher.  
release, to recycle power  
and accept the new baud/  
address setting. Refer to  
Figure 4 for the location of  
the reset button.  
To change the baud rate, refer to Figure 1 and Table A.  
P
W
Table A. Baud Rate Switch Settings  
R
DATA  
IN  
RST  
Switch Setting  
Baud  
DATA  
6
7
Rate  
2400  
4800  
9600  
CAM  
OFF  
ON  
OFF  
OFF  
ON  
MRD1400HZ16  
Made in USA  
SW1  
NOTE: Dip switches 8, 9,  
and 10 are factory set. Do  
not change switch positions.  
OFF  
DEFAULT SWITCH  
SETTINGS: 6 & 10 ON  
ALL OTHER SWITCHES OFF  
01218  
Figure 1. SW-1 Default Switch Settings  
4
Pelco Manual C1973M-B (8/03)  
 
MRD ADDRESS SETTINGS  
A camera address setting is required for the controller/switcher to communicate with the  
MRD1400HZ16. The default setting for the MRD is Receiver Address 1. If you are using  
more than one MRD, each unit must have a different Receiver Address.  
To change the address setting of the MRD, refer to Figure 1 and Table B.  
Table B. MRD DIP Switch Settings  
MRD DIP Switch Setting  
Receiver  
Address  
1
2
3
4
5
1
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
On  
Off  
Off  
On  
On  
Off  
Off  
On  
On  
Off  
Off  
On  
On  
Off  
Off  
On  
On  
Off  
Off  
On  
On  
Off  
Off  
On  
On  
Off  
Off  
On  
On  
Off  
Off  
On  
On  
Off  
Off  
Off  
Off  
On  
On  
On  
On  
Off  
Off  
Off  
Off  
On  
On  
On  
On  
Off  
Off  
Off  
Off  
On  
On  
On  
On  
Off  
Off  
Off  
Off  
On  
On  
On  
On  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
On  
On  
On  
On  
On  
On  
On  
On  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
On  
On  
On  
On  
On  
On  
On  
On  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
Off  
On  
On  
On  
On  
On  
On  
On  
On  
On  
On  
On  
On  
On  
On  
On  
On  
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
Pelco Manual C1973M-B (8/03)  
5
 
MRD1400HZ16 INSTALLATION METHODS  
There are three methods of installation for the MRD1400HZ16. The unit can be mounted  
directly to a wall, or installed inside a dome or enclosure using the supplied mount adapters.  
Refer to the following sections and select the correct installation method for your application.  
WALL MOUNTING  
To mount the MRD1400HZ16 directly to a wall, refer to Figure 2 and do the following:  
1. Select the mounting location. Install the unit close to the camera.  
2. Use the MRD1400HZ16 as a template to mark the two fastener positions onto the  
mounting surface.  
3. Prepare the surface and install the fasteners. Do not tighten fasteners at this time.  
4. Align the mounting holes of the MRD1400HZ16 with the installed wall fasteners.  
5. Place the unit over the fasteners, and then slide the box down into position. Tighten  
the fasteners to secure the unit to the wall.  
6. Make all required control, power, and camera connections. Refer to Figure 8 and the  
Control, Power, and Camera Connections section of this manual.  
4-40 PHILLIPS BUTTON  
HEAD SCREW  
TO  
CAMERA  
01220  
Figure 2. Wall Mounting  
DF5/DF8 SERIES DOME INSTALLATION  
To install the MRD1400HZ16 in a DF5/DF8 dome:  
1. Remove the MRD board from the MRD1400HZ16. To remove the board:  
a. Unscrew the two Phillips button head screws from the unit (refer to Figure 2), and  
remove the cover. Discard the screws.  
b. Using a small screwdriver, carefully pry each corner of the board from the PEM  
studs. Refer to Figure 4.  
2. Use the four 4-40 Phillips button head screws (provided) to attach the board to the  
DF5/DF8/EH2512 Series adapter.  
3. Assemble the tilt table supplied with the dome. For detailed instructions refer to the  
manual supplied with the DF5/DF8 Series dome.  
4. Refer to Figure 3. Attach the board to the tilt table with the supplied #10 nut and  
washer.  
5. Make all required control, power, and camera connections. Refer to Figure 8 and the  
Control, Power, and Camera Connections section of this manual.  
6. Refer to the manual supplied with the DF5 or DF8 Series dome to install the camera  
and complete the installation.  
6
Pelco Manual C1973M-B (8/03)  
 
CAMERA BRACKET  
DOME  
MRD1400HZ16  
AND MOUNT ADAPTER  
01212  
Figure 3. DF5/DF8 Installation  
POWER LED  
RESET BUTTON  
DATA LED  
01216  
Figure 4. Removing the MRD Board  
Pelco Manual C1973M-B (8/03)  
7
 
EH3512 SERIES ENCLOSURE INSTALLATION  
Do the following to install the MRD1400HZ16 in an EH3512 Series enclosure:  
1. Remove the camera sled from the EH3512 Series enclosure. If the camera is attached  
to the sled remove the camera.  
2. Attach the camera to the 4-inch camera sled supplied with the MRD. Install the cam-  
era sled and camera into the enclosure. Place the camera sled as close to the viewing  
window as possible.  
3. Remove the PC board from the MRD1400HZ16. To remove the board:  
a. Unscrew the two Phillips button head screws from the unit (refer to Figure 2), and  
remove the cover.  
b. Using a small screwdriver, carefully pry each corner of the board from the PEM  
studs. Refer to Figure 4.  
4. Refer to Figure 5. Install the EH3512 adapter into the enclosure.  
5. Make all required control, power, and camera connections to the board. Refer to  
Figure 8 and the Control, Power and Camera Connections section of this manual.  
6. Refer to Figure 6. Position the board over the EH3512 adapter. The DIP switches of  
the board should face up. Lightly press on each corner of the board to attach it to the  
PEM studs of the adapter.  
BACK OF  
EH3512  
ADAPTER PLATE  
01213  
Figure 5. Installing the EH3512 Adapter  
PEM  
STUD  
01214  
DIP SWITCHES  
MRD-1400HZ16  
Figure 6. Installing the MRD Board onto the EH3512 Adapter  
8
Pelco Manual C1973M-B (8/03)  
 
EH2512 SERIES ENCLOSURE INSTALLATION  
To install the MRD1400HZ16 in an EH2512 Series enclosure:  
1. Remove the PC board from the MRD1400HZ16. To remove the board:  
a. Unscrew the two Phillips button head screws from the unit (refer to Figure 2), and  
remove the cover. Discard the screws.  
b. Using a small screwdriver, carefully pry each corner of the board from the PEM  
studs. Refer to Figure 4.  
2. Use the four 4-40 Phillips button head screws (provided) to attach the board to the  
DF5/DF8/EH2512 Series adapter.  
3. Remove the camera sled from the housing. Refer to the manual supplied with the  
EH2512 Series enclosure.  
4. Make all required control, power, and camera connections. Refer to Figure 8 and the  
Control, Power, and Camera Connections section of this manual.  
5. Refer to Figure 7. Attach the board to the camera sled of the enclosure with the sup-  
plied #10 nut and washer.  
6. Refer to the manual supplied with the EH2512 Series enclosure to install the camera  
and complete the installation.  
MRD BOARD  
DATA IN  
CONNECTION  
#10 WASHER  
#10 NUT  
01217  
Figure 7. EH2512 Series Enclosure Installation  
Pelco Manual C1973M-B (8/03)  
9
 
CONTROL, POWER, AND CAMERA CONNECTIONS  
1. Refer to Figure 8 and Table C. Connect the control wires from the controller to the  
MRD DATA IN connector. Use the supplied four-pin connector. To connect multiple  
units with parallel connections refer to Figure 9.  
2. Connect one end of the 12-inch data cable into the CAM input of the MRD (refer to  
Figure 8). Connect the other end of the cable to the camera connector labeled CON-  
TROL OUT. If the installation requires a longer data cable refer to Figure 10. Maximum  
cable length is 25-feet.  
3. Make required power connections. Refer to Figure 8.  
Note: Input power range 12-24 volts AC/DC.  
T+  
T-  
(+)  
NO CONNECT  
(-)  
R-  
R+  
Table C. Two-Wire Control Connections  
From  
Controller  
MRD  
R+  
P
W
R
TX+  
DATA  
IN  
TX-  
R-  
RST  
DATA  
CAM  
MRD1400HZ16  
Made in USA  
SW1  
01219  
Figure 8. Control, Power, and Camera Connections  
CC1400HZ16  
CC1400HZ16  
CC1400HZ16  
FROM THE  
CONTROLLER  
Tx+  
Tx-  
MRD  
MRD  
MRD  
T+ T- R+ R- T+ T- R+ R- T+ T- R+ R-  
Figure 9. Multiple Units with Parallel Connections  
ONE TWIST IN CABLE  
PIN  
PIN  
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
LOCKING TAB ON BOTTOM  
01221  
Figure 10. Data Cable Wiring  
10  
Pelco Manual C1973M-B (8/03)  
 
OPERATION  
CAMERA OPERATION  
Zoom In  
PELCO CONTROLLER COMMAND  
Tilt joystick up  
Zoom Out  
Tilt joystick down  
Quickly Zoom In  
Press the Zoom Tele button or turn the joystick clockwise  
Press the Zoom Wide button or turn the joystick counterclockwise  
Press the Focus Near button  
Quickly Zoom Out  
Focus Near  
Focus Far  
Press the Focus Far button  
Increase Brightness  
Press the Iris Open button  
Decrease Brightness  
Enter/Exit the camera menu  
Navigate through the camera menu  
Increase the value of the selected menu item  
Decrease the value of the selected menu item  
Press the Iris Close button  
*Preset 95 or AUX 8 ON  
Move the joystick up or down to move through menu selections  
Press the Focus Far button  
Press the Focus Near button  
PRESETS (Refer to the documentation supplied with the controller for instructions on how to set and call a preset.)  
Save camera action as preset 1-8  
1-8 Set  
Move to preset position 1-8  
1-8 Call  
Clear control lockup if undefined preset is called  
Enter/Exit menu  
Preset 9 Call  
*Preset 95 Call  
AUX (Refer to the documentation supplied with the controller for instructions on auxiliary commands.)  
Turn camera power on  
Aux 1 on  
Aux 1 off  
Aux 2 on  
Aux 3 on  
Aux 3 off  
Aux 4 on  
Aux 6 on  
Turn camera power off  
Enable/Disable the three digit MRD address display  
Turn digital zoom on  
Turn digital zoom off  
Reset the Camera  
Display mirror image on screen; left-right flip  
(digital zoom must be enabled)  
Display normal image on screen  
(digital zoom must be enabled)  
Aux 6 off  
Display current software version for 3 seconds  
Enter/Exit menu  
Aux 7 on  
*Aux 8 on  
*Subsequent operation must be performed before repeating command.  
Pelco Manual C1973M-B (8/03)  
11  
 
TROUBLESHOOTING  
Problem  
Possible Cause and Solutions  
Unit does not operate. No power.  
1. Check to see if the power LED is lit. If the LED is not lit:  
a. Verify input power is good.  
b. Check power connections to make sure the wires are making contact.  
c. Verify the input power source is in range 12-24 volts AC/DC.  
Camera does not respond or  
responds improperly to commands.  
1. Check the baud rate of the MRD and the controller/switcher. Both should have the  
same baud rate setting.  
2. The camera address is not set correctly. Check the MRD camera address setting.  
3. If the baud or address switch settings are changed, press the power reset button (see  
Figure 4).  
Video erratic. Control lock up.  
Can not call preset.  
1. The selected preset has not been defined. To clear lock up:  
a. Call preset 9.  
b. Define new preset.  
DATA LED is not lit.  
1. Check connection to the camera.  
2. Push and hold the power reset button for 5 seconds and then release, to recycle power  
to the camera. Refer to Figure 4.  
SPECIFICATIONS  
MECHANICAL  
Construction:  
Dimensions:  
Electrical:  
Aluminum  
3.30 (H) x 3.70 (W) x 1.12 (D) inches (8.38 x 9.40 x 2.84 cm)  
12-24 VAC/VDC (+10%/-15%), 50/60-HZ  
Power Consumption: <1 watt  
Communication:  
RS-422, half-duplex  
(Design and product specifications subject to change without notice.)  
PRODUCT WARRANTY AND RETURN INFORMATION  
WARRANTY  
Pelco will repair or replace, without charge, any merchandise proved defective in material or  
workmanship for a period of one year after the date of shipment.  
If  
a
warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or  
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following  
information:  
1. Model and serial number  
Exceptions to this warranty are as noted below:  
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number  
3. Details of the defect or problem  
Five years on FT/FR8000 Series fiber optic products.  
Three years on Genex® Series products (multiplexers, server, and keyboard).  
If there is a dispute regarding the warranty of a product which does not fall under the  
warranty conditions stated above, please include a written explanation with the product  
when returned.  
Three years on Camclosure® and fixed camera models, except the CC3701H-2,  
CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models,  
which have a five-year warranty.  
Method of return shipment shall be the same or equal to the method by which the item was  
received by Pelco.  
Two years on standard motorized or fixed focal length lenses.  
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series  
fixed dome products.  
RETURNS  
In order to expedite parts returned to the factory for repair or credit, please call the factory at  
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned  
for credit, and RA number if returned for repair).  
Two years on Spectra®, Esprit®, ExSite, and PS20 scanners, including when used in  
continuous motion applications.  
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).  
All merchandise returned for credit may be subject to a 20% restocking and refurbishing  
charge.  
Eighteen months on DX Series digital video recorders, NVR300 Series network video  
recorders, and EnduraSeries distributed network-based video products.  
Goods returned for repair or credit should be clearly identified with the assigned CA or RA  
number and freight should be prepaid. Ship to the appropriate address below.  
One year (except video heads) on video cassette recorders (VCRs). Video heads will be  
covered for a period of six months.  
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:  
Service Department  
Pelco  
Six months on all pan and tilts, scanners or preset lenses used in continuous motion  
applications (that is, preset scan, tour and auto scan modes).  
3500 Pelco Way  
Clovis, CA 93612-5699  
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco  
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,  
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident  
are not covered under this warranty.  
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are  
instructed to return goods to the USA, you may do one of the following:  
If the goods are to be sent by a COURIER SERVICE, send the goods to:  
Pelco  
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from  
the specific use or application made of the Products. Pelcos liability for any claim, whether  
based on breach of contract, negligence, infringement of any rights of any party or product  
liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for  
such Products. In no event will Pelco be liable for any special, incidental or consequential  
damages (including loss of use, loss of profit and claims of third parties) however caused,  
whether by the negligence of Pelco or otherwise.  
3500 Pelco Way  
Clovis, CA 93612-5699 USA  
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:  
Pelco c/o Expeditors  
473 Eccles Avenue  
The above warranty provides the Dealer with specific legal rights. The Dealer may also have  
additional rights, which are subject to variation from state to state.  
South San Francisco, CA 94080 USA  
Phone: 650-737-1700  
Fax: 650-737-0933  
REVISION HISTORY  
Manual #  
C1973M  
C1973M-A  
C1973M-B  
Date  
10/01  
8/02  
Comments  
Original version.  
Revised instructions.  
8/03  
Revised supplied parts list and installation instructions for DF5/DF8 and EH2512 enclosures.  
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco.  
Endura and ExSite are trademarks of Pelco.  
© Copyright 2003, Pelco  
All rights reserved.  
12  
Pelco Manual C1973M-B (8/03)  
 

Peavey Portable Speaker DTH 4215 User Manual
Peavey Stereo Amplifier IP 4C User Manual
Philips Automobile 520H User Manual
Philips Baby Accessories SCF884 01 User Manual
Philips CRT Television Television Set Remote Control User Manual
Philips Portable DVD Player PET744 12 User Manual
Philips Speaker SBC BA140 User Manual
Philips TV Cables SWA2525 User Manual
Pioneer Car Amplifier DEH 2020MP User Manual
PYLE Audio Music Pedal PPDLHM User Manual