Important Safety Instructions  
Prior to installation and use of this product, the following WARNINGS should be observed.  
1. Installation and servicing should be done only by qualified service personnel and conform to all local codes.  
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not  
be installed where exposed to rain and moisture.  
3. Only use replacement parts recommended by Pelco.  
4. After replacement/repair of this unit’s electrical components, conduct a resistance measurement between line and exposed parts to verify  
the exposed parts have not been connected to line circuitry.  
5. The installation method and materials should be capable of supporting four times the weight of the enclosure, pan and tilt, camera and lens  
combination.  
The product and/or manual may bear the following marks:  
This symbol indicates that dangerous voltage constituting a risk of electric  
shock is present within this unit.  
CAUTION:  
RISK OF ELECTRIC SHOCK.  
This symbol indicates that there are important operating and maintenance  
DO NOT OPEN.  
instructions in the literature accompanying this unit.  
Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.  
Description  
The EH8106L is a sealed and pressurized camera enclosure designed for use with PT780 Series Legacy® pan and tilts. The enclosure has lens  
preset capabilities and is designed for cameras with fixed focal length or motorized zoom lenses. Two 40-watt heaters are also standard with the  
enclosure.  
The EH8106L makes use of the Legacy Series system of integral CCTV components. Legacy components make the installation of the pan and tilt  
and enclosure fast and easy. The RediLINK® connector is a feature that attaches the enclosure mechanically and electrically to the pan and tilt in  
one easy step.  
C1420M-H (1/07)  
3
 
   
Installation  
MOUNTING  
To attach the enclosure to the pan and tilt unit, perform the following installation steps.  
1. Make sure the tilt shaft on the pan and tilt unit is near horizontal so that the connector in the tilt shaft is pointing upward.  
2. Lift the housing over the pan and tilt unit, and align the connector in the bottom of the enclosure to the mating connector in the top of the  
pan and tilt unit.  
3. Place the enclosure down onto the pan and tilt unit. Move the enclosure side-to-side and back and forth as required to mate the two  
connectors. Once the two units are mated, apply firm pressure downward and to the back of the enclosure to fully seat the enclosure to the  
pan and tilt unit.  
4. Balance the enclosure on the pan and tilt. Tighten the two screws in the back of the RediLINK clamp with a 3/32-inch Allen wrench.  
CAMERA AND LENS INSTALLATION  
To install the camera and lens, perform the following steps:  
a. Remove the spiral retaining ring from the back of the enclosure. Use a screwdriver to pry the end of the spiral retaining ring from the  
retaining ring groove.  
b. Pull on the T-handle to remove the rear plate from the housing.  
2. Slide the sled out of the enclosure.  
3. Remove the desiccant bag from the camera sled. Do not discard the bag.  
4. Mount the camera and lens onto the sled:  
a. Extend the lens to the maximum length before positioning the camera and lens.  
b. Position the camera and lens so that they do not extend beyond the track.  
c. Fasten the camera and lens to the sled. Fastener is not supplied.  
5. Connect wiring for camera power, lens functions, and video. Refer to Figure 2.  
6. Unwrap and install the desiccant bag inside the enclosure.  
7. Reinstall the camera sled by sliding it back into the enclosure body. Secure with the spiral retaining ring.  
8. Pressurize the inside of the enclosure and assemble the mating connector. Refer to the sections Recharging the Enclosure and Mating  
Connector Assembly.  
4
C1420M-H (1/07)  
 
     
SCHRAEDER  
VALVE  
RETAINING  
SPRING  
END  
PRESSURE  
RELIEF VALVE  
GROUND STUD  
SPIRAL  
RETAINING  
SPRING  
T-HANDLE  
Figure 1. EH8106L Enclosure - Rear View  
HTR  
GROUND  
HTR  
THERMOSTAT  
A
L
B
K
M
F
N
S
C
J
P
R
D
PP ZOOM  
PP FOCUS  
PP COM  
PP +5V  
E
G
TABLE A  
FUNCTION  
VIDEO  
VIDEO  
PP +5V  
PP COM  
PIN NO.  
COLOR  
COAX CORE  
COAX SHIELD  
BLK/WHT  
RED/WHT  
BLU  
VIO  
GRN/WHT  
BLK  
A
B
C
D
E
F
G
H
J
CAMERA AC LINE  
CAMERA AC NEUT  
PS SWITCH  
AC LINE  
PS SWITCH  
IRIS  
FOCUS  
WHT/GRN  
BRN  
K
L
RED  
M
N
P
R
S
ZOOM  
LENS  
AC NEUTRAL  
PP FOCUS  
PP ZOOM  
ORG  
COM YEL  
WHT  
YEL/WHT  
GRY/WHT  
Figure 2. EH8106L Enclosure - Wiring Diagram  
C1420M-H (1/07)  
5
 
   
MATING CONNECTOR ASSEMBLY  
To assemble the 16-pin mating connector, perform the following  
steps:  
4. Solder the individual conductors to the appropriate pins in  
the back of the connector (refer to Figure 2). Push the  
rubber grommet into the back of the connector.  
1. Discard the white plastic sleeve that is included with the  
connector assembly. Thread the cable through the  
compression nut/strain relief and connector shell.  
BACK OF CONNECTOR  
GROMMET  
CONNECTOR  
SHELL  
COMPRESSION NUT  
AND STRAIN RELIEF  
2. Prepare the cabling by doing the following:  
Control Cable  
a. Strip the outer jacket back 2 inches (5 cm).  
5. Screw the connector shell to the back of the connector  
and tighten. Tighten the compression nut/strain relief as  
far as possible to compress the sealing ring inside the  
shell. Attach the cable clamps to the compression nut/  
strain relief.  
b. Strip the individual conductors back 1/4-inch (6 mm)  
and thread them into the appropriate holes through  
the rubber grommet. Refer to Figure 2.  
RUBBER  
GROMMET  
THREADED END  
COMPRESSION NUT  
AND STRAIN RELIEF  
CONNECTOR  
SHELL  
CABLE CLAMP  
THREADED END  
3. Assemble the back of the connector.  
6
C1420M-H (1/07)  
 
RECHARGING THE ENCLOSURE  
You may use your own charging equipment or Pelco’s EH8000RKIT to recharge the enclosure. If you are using your own equipment, adjust the  
regulator for an output pressure of 12 psi (83 kPa). If you are using the EH8000RKIT, it uses a regulator with a fixed, nonadjustable output  
pressure of 12 psi (83 kPa). The gauge reads the tank pressure only.  
1. Open the tank valve of the charging kit.  
2. Remove the cap from the enclosure’s Schraeder valve and then attach the air chuck from the charging equipment to the valve.  
3. To reduce the purge time necessary to remove air from the enclosure, position the enclosure so that the window is pointing up.  
4. Remove the plastic cap on the pressure relief valve on the rear of the enclosure. Use a small screwdriver and hold the valve open. Allow the  
nitrogen to flow through the enclosure until the humidity indicator registers the lowest humidity level, changing color from pink to blue.  
(The humidity indicator can be viewed through the front window of the enclosure looking at the inside top of the enclosure.) Once the  
humidity indicator registers the lowest level, remove the screwdriver and allow nitrogen to continue to flow into the enclosure until you no  
longer hear the flow of nitrogen from the tank to the enclosure.  
5. Remove the charging equipment air chuck from the Schraeder valve. Replace the Schraeder valve and pressure relief valve caps.  
POWER CONNECTION  
1. Connect ground wire to the ground stud on the back of the enclosure.  
2. Connect the mating connector to the rear of the enclosure.  
Operation  
The heaters are thermostatically controlled to come on at 40°F (4°C) and go off at 60°F (16°C).  
Maintenance  
At a minimum, the enclosure should be recharged once a year. Also, recharge the enclosure after opening for servicing. Refer to the Servicing  
section for instructions on how to disassemble, reassemble, and charge the enclosure.  
C1420M-H (1/07)  
7
 
       
Servicing  
DISASSEMBLY  
CAUTION: Pressure must be released prior to opening the enclosure or personal injury may result.  
1. Disconnect the power from the enclosure.  
2. Remove the mating connector from the rear of the enclosure by turning the outer ring counterclockwise until a click is felt; then pull the  
mating portion of the connector off. You may elect to remove the enclosure from its mount, which will make the disassembly process much  
easier.  
4. Relieve internal enclosure pressure by depressing and holding down the center stem of the Schraeder valve.  
a. Remove the spiral retaining ring from the back of the enclosure. Use a screwdriver to pry the end of the spiral retaining ring from the  
retaining ring groove.  
b. Pull on the T-handle to remove the rear plate from the housing.  
RECHARGING AND REASSEMBLY  
Whenever the enclosure is disassembled for servicing, it should be recharged after reassembly and prior to installation. Recharging requires the  
use of a Pelco EH8000RKIT recharge kit (or equivalent) and O-ring kit, part number EH8006ORKIT.  
To prepare the enclosure for recharging, follow the steps below.  
1. Once the enclosure has been disassembled, remove the O-ring from the rear plate and install a new O-ring in the O-ring groove in the rear  
plate.  
2. When the new O-ring has been installed in the rear plate, smear a liberal amount of the O-ring lubricant provided with the kit on the  
exterior surface of the O-ring and rear plate. Replace the desiccant bag in the enclosure with a new one provided with the kit.  
3. Slide the camera sled back into the body making sure the front lip of the sled is under the retaining bracket of the enclosure. When fully  
installed, the rear plate will fit firmly into the rear opening of the housing and the retaining groove will be fully visible.  
4. Reinstall the spiral retaining ring in the retaining groove in the rear of the enclosure.  
5. Recharge the enclosure. Refer to the section Recharging and Reassembly for instructions.  
8
C1420M-H (1/07)  
 
     
Specifications  
Electrical  
Input Voltage  
120 VAC (230 VAC optional) for heaters  
80 watts  
Power Consumption (heater)  
Connector  
16-pin jam nut receptacle  
Maximum Cable Distances  
(120 VAC)  
16 AWG (0.5 mm2)  
18 AWG (1.0 mm2)  
20 AWG (1.5 mm2)  
16 AWG (0.5 mm2)  
18 AWG (1.0 mm2)  
20 AWG (1.5 mm2)  
2,238 ft (682 m)  
1,410 ft (430 m)  
886 ft (270 m)  
8,224 ft (2,507 m)  
5,182 ft (1,579 m)  
3,257 ft (993 m)  
(230 VAC)  
Heater  
Two 40 watt, 120 VAC. Heaters are thermostatically controlled to activate ON at 40°F (4°C) and OFF at  
60°F (16°C)  
General  
Construction  
Aluminum 6061 T6  
Finish  
Outside  
Inside  
Polyester powder coat  
Black anodized  
Dimensions  
Front Window  
6-inch diameter tempered glass, 0.225-inch thick  
Maximum Camera/Lens Size  
5" diameter x 18" long (12.7 x 45.72 cm)  
or  
18" L x 4.0" W x 4.0" H inches (45.72 x 10.16 x 10.16 cm)  
Enclosure Mounting  
Purge Fitting  
Purge Relief Fitting  
Weight  
RediLINK 26-pin connector mates enclosure to pan/tilt  
Standard Schraeder valve to allow enclosure to be filled with dry nitrogen  
Prevents over-pressurization of enclosure  
17.2 lb (7.8 kg)  
Ratings  
Meets NEMA Type 6 and IP 67 standards  
C1420M-H (1/07)  
9
 
 
ENVIRONMENTAL  
Ambient Operating Temperature  
Vibration  
-40° to 122°F (-40° to 50°C) (with heater)  
5 to 60 Hz with 0.082 inch total travel (15 g’s at 60 Hz). From 60 to 1,000 Hz, 5 g’s rms with  
random vibration.  
Altitude  
Sea level to equivalent of 10,000 feet (3,048 m)  
Operates in 150 dB acoustic noise environments  
Acoustic Noise  
Humidity  
Up to 100% relative humidity. Equipped with standard Schraeder and pressure relief valves provide  
positive internal pressure with dry nitrogen.  
(Design and product specifications subject to change without notice.)  
9.25  
(16.51)  
6.5  
(16.51)  
7.0 (REF)  
(17.78)  
20.00  
(50.80)  
22.00  
(55.88)  
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS;  
ALL OTHERS ARE INCHES.  
Figure 3. EH8106L Enclosure Dimension Drawing  
10  
C1420M-H (1/07)  
 
 
PRODUCT WARRANTY AND RETURN INFORMATION  
WARRANTY  
Pelco will repair or replace, without charge, any merchandise proved defective in material or  
workmanship for a period of one year after the date of shipment.  
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or  
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following  
information:  
Exceptions to this warranty are as noted below:  
1. Model and serial number  
Five years on FR/FT/FS Series fiber optic products and TW3000 Series unshielded twisted  
pair transmission products.  
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number  
3. Details of the defect or problem  
Three years on Spectra® IV products.  
If there is a dispute regarding the warranty of a product which does not fall under the  
warranty conditions stated above, please include a written explanation with the product  
when returned.  
Three years on Genex® Series products (multiplexers, server, and keyboard).  
Three years on Camclosure® and fixed camera models, except the CC3701H-2,  
CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models,  
which have a five-year warranty.  
Method of return shipment shall be the same or equal to the method by which the item was  
received by Pelco.  
Three years on PMCL200/300/400 Series LCD monitors.  
Two years on standard motorized or fixed focal length lenses.  
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series  
fixed dome products.  
Two years on Spectra III, Esprit®, ExSite, and PS20 scanners, including when used in  
continuous motion applications.  
RETURNS  
In order to expedite parts returned to the factory for repair or credit, please call the factory at  
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned  
for credit, and RA number if returned for repair).  
Two years on Esprit and WW5700 Series window wiper (excluding wiper blades).  
All merchandise returned for credit may be subject to a 20% restocking and refurbishing  
charge.  
Two years (except lamp and color wheel) on Digital Light Processing (DLP®) displays.  
The lamp and color wheel will be covered for a period of 90 days. The air filter is not  
covered under warranty.  
Goods returned for repair or credit should be clearly identified with the assigned CA or RA num-  
ber and freight should be prepaid. Ship to the appropriate address below.  
Eighteen months on DX Series digital video recorders, NVR300 Series network video  
recorders, and EnduraSeries distributed network-based video products.  
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:  
One year (except video heads) on video cassette recorders (VCRs). Video heads will be  
covered for a period of six months.  
Service Department  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699  
Six months on all pan and tilts, scanners or preset lenses used in continuous motion  
applications (that is, preset scan, tour and auto scan modes).  
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco  
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,  
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident  
are not covered under this warranty.  
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed  
to return goods to the USA, you may do one of the following:  
If the goods are to be sent by a COURIER SERVICE, send the goods to:  
Pelco  
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from  
the specific use or application made of the Products. Pelco’s liability for any claim, whether  
based on breach of contract, negligence, infringement of any rights of any party or product  
liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for  
such Products. In no event will Pelco be liable for any special, incidental or consequential  
damages (including loss of use, loss of profit and claims of third parties) however caused,  
whether by the negligence of Pelco or otherwise.  
3500 Pelco Way  
Clovis, CA 93612-5699 USA  
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:  
Pelco c/o Expeditors  
473 Eccles Avenue  
South San Francisco, CA 94080 USA  
Phone: 650-737-1700  
Fax: 650-737-0933  
The above warranty provides the Dealer with specific legal rights. The Dealer may also have  
additional rights, which are subject to variation from state to state.  
The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC.  
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union  
regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.  
REVISION HISTORY  
Manual #  
C1420M  
C1420M-A  
C1420M-B  
Date  
1/95  
4/95  
5/96  
Comments  
Original version.  
Rev. A. Incorporates changes in Section 4.0 and Figure 1 for unit weights and dimensions and maximum camera/lens dimensions per ECO #95-042.  
Rev. B. Incorporates changes in heater blankets and brackets per ECO #96-147. Part references updated accordingly and Figure 3 redone. Pressure switch  
information added per ECO # 95-220.  
C1420M-C  
5/96  
7/97  
6/98  
Rev. C. Figure 3 reused to remove pressure sensor switch. Refer to manual C1445M for switch wiring. Figure 5 and Section 8.2 revised to include grounding lug.  
Section 7.3, step 4 revised (color: pink to blue). Added new Section 3.2 for CE and UL compliance.  
Removed references to UL compliance. Changed format.  
11/98  
7/00  
Revised Figure 4. Editing changes.  
C1420M-D  
Revised manual to include grounding stud on rear plate. Revised mating connector assembly instructions and diagram. Moved exploded assembly diagram and parts  
lists to new maintenance/service manual (C1420SM). Removed installation instructions for sun shroud, which has separate manual. Updated manual to new format.  
Revised enclosure pressure from 5 psi to 8 psi.  
Factory preset for regulator changed to 12 psi per ECO# 04-9807. Updated layout.  
Revised instructions and artwork for mating connector assembly per ECO #04-10254.  
Revised Specifications section for power consumption, maximum cable distances, and enclosure mounting.  
C1420M-E  
C1420M-F  
C1420M-G  
C1420M-H  
1/04  
12/04  
12/04  
1/07  
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco.  
Endura, ExSite, and Spectra III are trademarks of Pelco.  
©Copyright 2007, Pelco. All rights reserved.  
DLP is a registered trademark of Texas Instruments, Inc.  
 
®
Worldwide Headquarters  
3500 Pelco Way  
Clovis, California 93612 USA  
USA & Canada  
Tel: 800/289-9100  
Fax: 800/289-9150  
International  
Tel: 1-559/292-1981  
Fax: 1-559/348-1120  
ISO9001  
Australia Canada Finland France Italy Russia Singapore Spain Sweden The Netherlands United Arab Emirates United Kingdom United States  
|
|
|
|
|
|
|
|
|
|
|
|
 

Philips Cell Phone CTX800BLK User Manual
Philips Indoor Furnishings P 8515 B User Manual
Philips Speaker SPA3300 User Manual
Philips Work Light 40233 48 16 User Manual
Pinnacle Speakers Gas Grill TG475 2 User Manual
Pioneer Car Video System AVX P7650DVD User Manual
Planet Technology Switch POE 400 User Manual
Polaroid Digital Photo Frame IDF 0560 User Manual
Poulan Lawn Mower 190781 User Manual
PYLE Audio Speaker PDSUB8 User Manual