®
SD5 Series
Spectra®
(Software Version 3.0)
Dome
Installation/
Operation Manual
C1456M-D (10/98)
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120
5.11.17 Alarm Pattern ......................................................................46
5.11.18 Zone Blank .........................................................................46
5.11.19 Auto Flip..............................................................................47
5.11.20 Proportional Pan .................................................................47
5.11.21 Limit Stops ..........................................................................48
5.11.21.1 Turning Limit Stops On or Off ............................ 48
5.11.21.2 Programming Limit Stops ..................................48
5.11.22 Park Time Minutes ..............................................................49
5.11.23 Scan Speed ........................................................................49
5.11.24 Pattern Length ....................................................................50
6.0 TROUBLESHOOTING ..............................................................................51
6.1 BACK BOX ELECTRONIC ASSEMBLY REMOVAL..........................52
7.0 MAINTENANCE ........................................................................................53
7.1 DOME CLEANING ............................................................................53
7.2 SERVICE MANUAL ..........................................................................53
8.0 SPECIFICATIONS ....................................................................................54
9.0 WARRANTY AND RETURN INFORMATION ...........................................58
LIST OF ILLUSTRATIONS
Figure
Page
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
In-Ceiling Components ...................................................................... 9
Back Box Parts ..................................................................................9
Pendant Components .......................................................................10
Compass Tool ...................................................................................14
Conduit Fitting Installation ................................................................14
Installing Back Box............................................................................15
Fastening Back Box ..........................................................................15
Wiring Diagram .................................................................................16
Interconnect Door .............................................................................18
Transformer Wiring ............................................................................19
Interconnect Circuit Board Electrical Connections............................ 19
Switch Locations ...............................................................................21
Lower Dome Installation, In-Ceiling Models......................................27
Lower Dome Installation, Pendant Models........................................28
Backlight Compensation ...................................................................36
SD5 Series Dimension Drawing........................................................54
LIST OF TABLES
Table
Page
A
B
C
D
E
Video Coaxial Cable Wiring Distances .............................................17
24 VAC Wiring Distances ..................................................................17
Switch Settings for SW1 ...................................................................21
Switch Settings for SW2 – P-Type Control........................................22
Switch Settings for SW2 – D-Type Control .......................................23
Pelco Manual C1456M-D (10/98)
3
REVISION HISTORY
Manual # Date
Comments
C1456M
3/97
4/97
Original version.
Added instructions for assembling T-rail clip for metal
panel per ECO 97-134.
C1456M-A
C1456M-B
4/97
5/97
7/97
RevisionA. Added pendant models.
Added standard heater and sun shield.
Added Rev. 2 software features and low-temperature
heater.
9/97
Added note in Sections 3.2 and 5.1 about minimum
voltage requirement. In Section 4.1 added instructions for
sealing pendant dome from moisture. In Section 5.2 added
paragraph about pan/tilt operation with fixed-speed
controllers. Changed the minimum specification for the low-
temperature heater from -40°F (-40°C) to -60°F
(-51°C). Revised input power requirements.
12/97
In Section 1.2.2, added pipe sealant to parts list. In
Section 2.1.2, removed models with an “L” in the suffix;
removed heater kits; moved SD5-SS to Section 2.2. In
Section 2.2, added WX24. In Section 3.2, removed power
requirement for models with standard heater (obsolete);
emphasized that power ratings are “per dome.” In Table B,
removed column for 22-gauge wire. In Table C, removed
references to Spectra® working with CM9501. In Section
4.1, added note about moisture condensation. In Section
5.3 added note about zoom speed. In Section 5.7, added
patterns for CM6700. In Section 5.8, added note about
using presets without alarms. Added Section 5.11.15.
Revised Section 7.0. In Section 9, revised power and
temperature specifications. Throughout manual, removed
references to RS-485 control.
12/97
4/98
Section 1.1, Important Safeguards and Warnings, up-
dated to include French translation for CUL certification.
C1456M-C
Added Section 1.2, Regulatory Notices. Added in-ceiling
model exploded drawing in Section 1.3.1 and pendant
model exploded drawing in Section 1.3.2. In Section 2.1,
removed reference to standard and low-temperature
heaters. In Section 2.2, removed material on options and
added certification material. In Section 3.1.2, removed
optional metal panel reference in the Caution. Removed
Section 3.1.3 documentation on the optional suspended
ceiling panel and revised Figures 4 and 5 to reflect the
change. Changed the example in Section 3.2 to 90vA from
80vA. Revised Table B. Revised item 1 in Section 3.3 to
remove references to the metal panel. In Section 4.0,
revised the note and the installation instructions to include
information about sealing against moisture and condensa-
tion. In Section 4.2, added reference to pendant conduit
adapter. In Section 5.8, revised the note and documenta-
tion to include additional information and cautioning about
using alarm presets for multiple uses. Added Section 7.2,
Service Manual. Moved Section 8.0, Exploded Assembly
Diagrams to new service manual, C1455SM. Changed
manual pagination.
5/98
Revised Section 4.1 and Figures 3, 14, and 16 because
of modification to top mount.
4
Pelco Manual C1456M-D (10/98)
C1456M-D
8/98
Manual name changed to Spectra® (Software Version
3.0). In Section 2.2, revised the certifications. In Section
5.1, added information about selectable power-up mode.
In Section 5.2, revised information about high zoom in
turbo mode. Added Section 5.2.2, Scan Speed. In Section
5.6, added zone blanking information. In Section 5.7,
revised pattern material and added a note. In Section 5.8,
made extensive revisions and additions to material on
alarms. In Section 5.9, added material on programming
for AUX. In Section 5.11, added features to the list and
revised the menu structure. Changed the Main Menu
Access section number from 5.11.15 to 5.11.1, altering all
subsequent 5.11 section numbering. Added the following
sections to document new menu items: 5.11.12 (Power
Up Mode), 5.11.13 (AUX Mode), 5.11.14 (Alarm
Resume), 5.11.15 (Alarm Dwell), 5.11.16 (Alarm Priority),
5.11.17 (Alarm Pattern), and 5.11.18 (Zone Blank). In
Section 5.11.20, revised information about high zoom in
turbo mode. Moved the section on park time minutes
(new number 5.11.22) after the section on limit stops
(new number 5.11.21). Added the following sections to
document new menu items: 5.11.23 (Scan Speed) and
5.11.24 (Pattern Length). Added material in Section 6.0.
In Section 8.0, revised pan speed under Mechanical,
weights under General, and removed NTSC color camera
material under Camera.
10/98
Revised Section 6.0, Troubleshooting.
Pelco Manual C1456M-D (10/98)
5
(This page intentionally left blank.)
6
Pelco Manual C1456M-D (10/98)
1.0 GENERAL
1.1 IMPORTANT SAFEGUARDS AND
WARNINGS
1.1 MEASURES DE SECURITE
IMPORTANTES
Prior to installation and use of this product, the following
WARNINGS should be observed.
Avant d’installer ou d’utiliser ce produit, les mesures de
sécurité suivantes sont à prendre:
1. Toute installation et réparation devraient être
entreprises par un technicien qualifié et conformes
au codes locaux.
1. Installation and servicing should only be done by
qualified service personnel and conform to all local
codes.
2. Unless the unit is specifically marked as a NEMA
Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is de-
signed for indoor use only and it must not be installed
where exposed to rain and moisture.
2. A moins que cet equipement indique avoir un boitié
agrée NEMA de type 3, 3R, 3S, 4, 4X, 6 ou 6P, il est
uniquement conçu pour utilisation intérieure et ne
peut donc pas être en contact de pluie ou d’humidité.
3. Only use replacement parts recommended by
Pelco.
3. Utiliser seulement les pièces de rechanges
recommandées par Pelco.
4. After replacement/repair of this unit’s electrical
components, conduct a resistance measurement
between line and exposed parts to verify the ex-
posed parts have not been connected to line cir-
cuitry.
4. Après toute installation ou réparation de la partie
électrique de ce produit, une résistance entre le cou-
rant et la partie exposée devrait être installée afin
de vérifier que la partie électrique n’aie pas été en
contact d’un court circuit.
5. The installation method and materials should be ca-
pable of supporting four times the weight of the en-
closure, pan/tilt, camera and lens combination.
5. L’installation entreprise et le matériel utilisé devraient
supporter quatre fois le poids du boitié, de la tourelle,
de la caméra, et de la lentille.
Ce produit et/ou le manuel pourrait inclurent
les symbols suivants:
The product and/or manual may bear the
following marks:
This symbol indicates that dangerous voltage con-
stituting a risk of electric shock is present within this
unit.
Ce symbol indique qu’un voltage dangereux pouvant
provoquer un chock électrique est présant dans cette
unité.
This symbol indicates that there are important oper-
ating and maintenance instructions in the literature
accompanying this unit.
Ce symbol indique qu’il y a des mesures d’installation
et d’entretient importantes inclus dans le manuel de
cet équipement.
CAUTION:
RISK OF
CAUTION:
RISQUE DE
ELECTRIC SHOCK.
DO NOT OPEN.
CHOQUE ÉLECTRIQUE
NE PAS OUVRIR
CAUTION:
CAUTION:
TO REDUCE THE RISK OF ELECTRICAL SHOCK,
DO NOT REMOVE COVER. NO USER-
AFIN DE RÉDUIRE LES RISQUES DE CHOQUE
ÉLECTRIQUE, LE CACHE NE DEVRAIT PAS
ÊTRE RETIRÉ. POUR TOUTE RÉPARATION,
SE RÉFÉRER À UN TECHNICIEN.
SERVICEABLE PARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE PERSONNEL.
Please thoroughly familiarize yourself
with the information in this manual prior
to installation and operation.
Nous vous prions de bien vous
familiarisez avec la manuel avant
d’entreprendre toute installation.
Pelco Manual C1456M-D (10/98)
7
1.2 REGULATORY NOTICES
NOTE: This equipment has been tested and found to comply with the limits of a
Class A digital device, pursuant to part 15 of the FCC rules. These limits are de-
signed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the interfer-
ence at his own expense.
1.3 UNPACKING INSTRUCTIONS
Unpack and inspect all parts carefully.
Be sure to save the shipping carton, boxes and inserts. They are the safest material
in which to make future shipments.
If an item appears to have been damaged in shipment, replace it properly in its box
and contact the factory at 1-800-289-9100 or 1-59-292-1981 for a replacement.
(International customers fax 1-559-348-1120 for authorization and instructions.)
If an item needs to be returned to the factory for repair, consult the WARRANTY
AND RETURN section of this manual for instructions.
8
Pelco Manual C1456M-D (10/98)
1.3.1 In-Ceiling Models
The Spectra® (Version 3.0) dome shipping carton contains three boxes, plus the
C1456M-D system manual that covers everything in the system (back box, dome
drive, and lower dome). Inspect each box to make sure all parts are present.
Back Box
1
1
Back box
Parts bag (refer to Figure 2)
1 Conduit fitting
1 Safety chain bracket
1 Lock nut
1 Compass tool
4 T-rail clip (clip, L-bracket, screw, lock washer and nut)
Installation/Operation Manual (C1488M)
1
Dome Drive
1
1
Dome drive
Installation/Operation Manual (C1490M)
Lower Dome
1
1
Acrylic lower dome with trim ring
Installation Instructions (C1457M-B)
COMPASS TOOL
BACK
BOX
SAFETY
BRACKET
DOME
DRIVE
CONDUIT FITTING
& LOCK NUT
T-RAIL CLIP
LOWER
DOME
Figure 1. In-Ceiling Components
Figure 2. Back Box Parts
Pelco Manual C1456M-D (10/98)
9
1.3.2 Pendant Models
The Spectra® (Version 3.0) dome shipping carton contains three boxes, plus the
C1456M-D system manual that covers everything in the system (back box, dome
drive, and lower dome). Inspect each box to make sure all parts are present.
Back Box
1
1
1
Back box
Tube of pipe sealant
Installation/Operation Manual (C1488M)
Dome Drive
1
1
Dome drive
Installation/Operation Manual (C1490M)
Lower Dome
1
1
Acrylic lower dome with trim ring
Parts bag
1
1
2
1
O-ring
O-ring lubricant
Screw, 6-32 x 1/4" (black) or 6-32 x 5/16" (gray)
Tube of Loctite®
1
Installation Instructions (C1457M-B)
BACK
BOX
DOME
DRIVE
LOWER
DOME
Figure 3. Pendant Components
10
Pelco Manual C1456M-D (10/98)
1.4 RECOMMENDED TOOLS
Pelco does not supply basic tools needed for the installation process. The following
tools are recommended.
To install the back box:
Small flat screwdriver
BNC crimp tool
Wire stripper
Wire cutter
Pen or pencil (in-ceiling models only)
Drill with 3/32-inch drill bit (in-ceiling models only)
Saw to cut hole in ceiling (in-ceiling models only)
Medium Phillips screwdriver (in-ceiling models and pendant surface-mount only)
Drill with hole saw (pendant surface-mount only)
Coaxial cable stripper
To install the dome drive:
To install the lower dome:
None required
Medium Phillips screwdriver (pendant models only)
Pelco Manual C1456M-D (10/98)
11
2.0 DESCRIPTION
Spectra® (Version 3.0) domes are capable of the following:
•
•
360° pan rotation
+2 to -92° tilt
•
•
preset positioning
variable speed
The in-ceiling models can be installed in hard ceilings or standard 2' x 2' (61 cm x
61 cm) suspended ceilings. These models are for indoor installation only.
The pendant models can be installed indoors or outdoors. The outdoor models
include a sun shield and heater. The heater allows operation in temperatures down
to -60°F (-51°C).
All models include a high-resolution color or monochrome (black and white) cam-
era with a 12X optical, 8X electronic zoom lens for a total zoom ratio of 96X.
An integral receiver has a switch to select the type of control. The receiver supports
Coaxitron® and RS-422 control types.
The dome drive quickly disconnects from the back box for easy servicing or moving.
The Spectra® (Version 3.0) domes operate on 24 VAC.
2.1 MODELS
Each Spectra® (Version 3.0) system consists of one each: back box, dome drive, and
lower dome. Outdoor pendant systems include a sun shield and heater. Refer to
components below (in-ceiling or pendant) to determine your system configuration.
2.1.1 In-Ceiling Components
BB5A-F
DD5-C-X
DD5-M
DD5-M-X
LD5F-0
LD5F-1
LD5F-2
LD5F-3
Indoor back box for flush mounting in a ceiling
Dome drive with color camera/lens, PAL standard
Dome drive with monochrome camera/lens, EIA standard
Dome drive with monochrome camera/lens, CCIR standard
Smoked lower dome (1/2 f-stop of light loss)
Clear lower dome
Chrome lower dome (2 f-stops of light loss)
Gold lower dome (2 f-stops of light loss)
2.1.2 Pendant Components
BB5A-PB
BB5A-PG
BB5A-PG-E
DD5-C-X
DD5-M
Black pendant-mount back box
Light gray pendant-mount back box
Same as BB5A-PG except includes heater and sun shield
Dome drive with color camera/lens, PAL standard
Dome drive with monochrome camera/lens, EIA standard
Dome drive with monochrome camera/lens, CCIR standard
Smoked lower dome (1/2 f-stop of light loss) for black pendant-
mount dome
DD5-M-X
LD5PB-0
LD5PB-1
LD5PB-2
Clear lower dome for black pendant-mount dome
Chrome lower dome (2 f-stops of light loss) for black pendant-
mount dome
LD5PB-3
LD5PG-0
Gold lower dome (2 f-stops of light loss) for black pendant-
mount dome
Smoked lower dome (1/2 f-stop of light loss) for light gray
pendant-mount dome
LD5PG-1
LD5PG-2
Clear lower dome for light gray pendant-mount dome
Chrome lower dome (2 f-stops of light loss) for light gray
pendant-mount dome
LD5PG-3
Gold lower dome (2 f-stops of light loss) for light gray pendant-
mount dome
LD5PG-E0
LD5PG-E1
Same as LD5PG-0 except includes heater
Same as LD5PG-1 except includes heater
12
Pelco Manual C1456M-D (10/98)
2.2 CERTIFICATIONS
The products identified below have been tested and certified for agency compli-
ance as noted.
Agency Compliance Certification
Model
CE
FCC
UL
CSA/cUL
Spectra® (Ver. 3) DD5-C-X
Spectra® (Ver. 3) DD5-M
Spectra® (Ver. 3) DD5-M-X
Spectra® BB5A-F
X
X
X
X
X
X
X
Spectra® BB5A-PB
Spectra® BB5A-PG
Spectra® BB5A-PG-E
Pending
Pending
Pending
Pending
Pending
Pending
Applicable CE, FCC, UL, and CSA/cUL directives/standards:
• 93/68/ECC–CE Mark Directive
89/336/ECC, 92/31/ECC–Electromagnetic Compatibility (EMC) Directives
EN 55022: 1984 Class A–Radio-frequency emissions limits
EN 50082-2: 1992–Immunity standard
IEC 801-2: 1984–ESD immunity
IEC 801-3: 1984–Radiated field immunity
IEC 801-4: 1988–Electrical transients
• FCC-47 CFR, Part 15, Subpart B, Class A
• UL Listed (DRQH) E119552
• cUL Listed (DRQH7)
Additional applicable standards:
• NEMA Type 4 (except -F flush mount models; NEMA Type 1)
• IP 56 (except -F flush mount models; NEMA Type 10)
Pelco Manual C1456M-D (10/98)
13
3.0 INSTALLATION FOR IN-CEILING MODELS
To install the dome proceed through the steps in this section, beginning with Sec-
tion 3.1, “Ceiling and Back Box Preparation.”
3.1 CEILING AND BACK BOX PREPARATION
3.1.1 Hard Ceiling
1. Locate the center point where you want to drill a hole in the ceiling.
2. Drill a hole in the ceiling using a 3/32-inch drill bit.
NOTE: Use the SCA1 (structural
ceiling adapter) if additional support
is required.
3. Remove the compass tool from the parts bag that came with the back box
(refer to Figure 4). Press the stud of the compass tool into the hole in the
ceiling. Insert a pencil in the hole in the other end of the compass and mark a
circle on the ceiling.
CAUTION: Be careful
not to cut outside of the
line. If you do, you may not
be able to install the back
box. Also, the trim ring
may not cover the hole.
4. Carefully cut the circle out of the ceiling.
5. Remove the conduit fitting, lock nut, and safety chain bracket from the parts
bag and attach them to the back box as shown in Figure 5.
Proceed to Section 3.2, WIRING.
ATTACH SAFETY CHAIN HERE
Figure 4. Compass Tool
Figure 5. Conduit Fitting Installation
14
Pelco Manual C1456M-D (10/98)
3.1.2 Suspended Ceiling
1. Remove the ceiling tile from the ceiling.
CAUTION: The ceiling
tile must be capable of
supporting 16 pounds
(7.3 kg) of weight. If the
ceiling tile will not support
this weight, order the
SD5-P metal panel.
2. Locate the center point to drill a hole in the tile.
3. Drill a hole in the ceiling tile using a 3/32-inch drill bit.
4. Remove the compass tool from the parts bag that came with the back box
(refer to Figure 4). Press the stud of the compass tool into the hole in the
ceiling. Insert a pencil in the hole in the other end of the compass and mark a
circle on the ceiling.
CAUTION: Be careful
not to cut outside of the
line. If you do, you may not
be able to install the back
box. Also, the trim ring
may not cover the hole.
5. Carefully cut the circle out of the ceiling tile.
6. Remove the conduit fitting, lock nut, and safety chain bracket from the parts
bag and attach them to the back box as shown in Figure 5.
7. Refer to Figure 6. Compress the spring clips on the back box with your hands
and push the back box through the hole in the ceiling tile. The spring clips will
spring out when they clear the ceiling tile.
8. Refer to Figure 7. Tighten the screws until the spring clips hold the back box
firmly to the ceiling tile. You will hear a clicking noise when the screws are tight.
Do not install the ceiling tile in the ceiling yet.
Proceed to Section 3.2, WIRING.
HARD CEILING
OR
CEILING TILE
Figure 6. Installing Back Box
HARD CEILING
OR
CEILING TILE
T-RAIL CLIP
FOR
CEILING TILE
T-RAIL CLIP
FOR
CEILING TILE
Figure 7. Fastening Back Box
Pelco Manual C1456M-D (10/98)
15
3.2 WIRING
Bring wiring to the back box opening in the ceiling. Do not attach the wiring to the
back box. You will do that later.
Refer to Figure 8 for the wiring diagram.
Wiring is required for power, earth ground, and video.
Refer to Table A for the type of video coaxial cable to use.
Input power for the dome is 24 VAC only. Power consumption is 25 vA per dome for
indoor models and 90 vAfor outdoor models. Refer to Table B to determine the size
of wire to use.
Use a 24 VAC transformer with the following minimum vA:
NOTE: The dome will stop oper-
ating if the voltage at the dome
drops below 18 VAC. It will turn
back on when the voltage exceeds
18 VAC.
30 vA per dome
100 vA per dome For outdoor models (with heater)
For indoor models (without heater)
Refer to Figure 10 for wiring multiple domes from the same transformer.
If you are using a Coaxitron® controller, the control signals to operate the dome
drive will be transmitted over the video coax. The RS-422 control lines are not used.
If you are not using a Coaxitron® controller, use the RS-422 control lines. Use 22-
gauge wire. The distance will be the same as the video coax.
Optional wiring may be provided for alarm inputs (maximum of seven), relay output,
and auxiliary output.
Proceed to Section 3.3, BACK BOX INSTALLATION.
SPECTRA® (VERSION 3.0) INTERCONNECT BOARD
CONTROL
(RS-422)
7
+5 to +24 VDC
EXTERNAL RELAY
(WIRING EXAMPLE)
Figure 8. Wiring Diagram
16
Pelco Manual C1456M-D (10/98)
Table A. Video Coaxial Cable Wiring Distances
Cable Type*
Maximum Distance
RG59/U
RG6/U
RG11/U
750 ft (229 m)
1,000 ft (305 m)
1,500 ft (457 m)
* Minimum cable requirements:
75 ohms impedance. All-copper center conductor. All-copper braided
shield with 95% braid coverage
Table B. 24 VAC Wiring Distances
The following are the recommended maximum distances for 24 VAC with a 10-
percent voltage drop. (Ten percent is generally the maximum allowable voltage drop
for AC-powered devices.)
Wire Gauge
20
18
16
14
12
10
EXAMPLE: A dome that requires
90 vA and is installed 31 feet (9 m)
from the transformer would require
a minimum wire gauge of 20 Awg.
10
20
25
283 451 716 1142 1811 2880
(86) (137) (218) (348) (551) (877)
141 225 358 571 905 1440
(42) (68) (109) (174) (275) (438)
113 180 286 457 724 1152
NOTE: Distances are calculated
in feet; values in parentheses are
meters.
(34) (55) (87) (139) (220) (351)
30
40
50
60
70
80
90
94 150 238 380 603 960
(28) (45) (72) (115) (183) (292)
70
112 179
285 452 720
(86) (137) (219)
(21) (34) (54)
56
90 143
228 362 576
(69) (110) (175)
(17) (27) (43)
47 75 119
190 301 480
(57) (91) (146)
(14) (22) (36)
40 64 102
163 258 411
(49) (78) (125)
(12) (19) (31)
35 56 89
142 226 360
(43) (68) (109)
(10) (17) (27)
31 50 79
126 201 320
(38) (61) (97)
(9) (15) (24)
100 28
(8)
45 71
(13) (21)
114 181 288
(34) (55) (87)
110 25
(7)
41 65
103 164 261
(31) (49) (79)
(12) (19)
37 59
120 23
(7)
95
150 240
(11) (17)
(28) (45) (73)
130 21
(6)
34 55
87
139 221
(10) (16)
32 51
(26) (42) (67)
140 20
(6)
81 129 205
(9) (15)
30 47
(9) (14)
(24) (39) (62)
76 120 192
150 18
(5)
(23) (36) (58)
160 17
(5)
28 44
71 113 180
(8) (13)
26 42
(21) (34) (54)
67 106 169
170 16
(4)
(7) (12)
(20) (32) (51)
180 15
(4)
25 39
63 100 160
(7) (11)
23 37
(19) (30) (48)
60 95 151
190 14
(4)
(7) (11)
22 35
(6) (10)
(18) (28) (46)
57 90 144
(17) (27) (43)
200 14
(4)
Pelco Manual C1456M-D (10/98)
17
3.3 BACK BOX INSTALLATION
1. Suspended Ceiling Only (for hard ceiling, go to step 2) – Install the ceiling
tile with the back box. Attach a T-rail clip on each side of the ceiling tile as
shown in Figure 7.
OPTIONAL PROCEDURE: If
you prefer, you may make the wir-
ing connections inside the back box
before installing the back box in the
ceiling.
The clips for the ceiling tile are supplied with the back box. Attach the clip to
the T-rail. Fasten the L-bracket to the clip with the supplied screw, lock washer
and nut.
To do this, loosen the thumbscrew
inside the back box and open the
hinged door (refer to Figure 9).
Bring the wiring into the back box
through the conduit fitting. Follow
the steps in Section 3.4, “Back Box
Connections,” and then return to
this section.
2. Install a safety chain or cable (not supplied) that will support up to 16 pounds
(7.3 kg). Fasten one end to a support structure in the ceiling. Fasten the other
end to the safety chain bracket (refer to Figure 5) to prevent the back box from
falling.
3. Refer to Figure 9. Loosen the thumbscrew inside the back box and open the
hinged door.
4. Bring the wiring into the back box through the conduit fitting. If the wiring is
inside flexible conduit, connect the conduit to the fitting on the back box.
CAUTION: The ceiling
must be capable of sup-
porting 16 pounds (7.3 kg)
of weight. If the ceiling will
not support this weight,
provide additional rein-
forcement. Also, a suit-
able safety chain must be
attached to the back box
to support up to 16
pounds (7.3 kg) in the
event of a ceiling failure.
5. Hard Ceiling Only - Refer to Figure 6. Compress the spring clips on the back
box with your hands and push the back box through the hole in the ceiling. The
spring clips will spring out when they clear the ceiling. Refer to Figure 7. Tighten
the screws until the spring clips hold the back box firmly to the ceiling. You will
hear a clicking noise when the screws are tight.
Proceed to Section 3.4, BACK BOX CONNECTIONS.
THUMBSCREW
Figure 9. Interconnect Door
18
Pelco Manual C1456M-D (10/98)
3.4 BACK BOX CONNECTIONS
Refer to Figure 11 to attach the wiring to the interconnect circuit board inside the
back box. Also refer to Figure 8 if necessary.
1. Earth Ground - Connect earth ground to the middle connector on the power
connector.
WARNING: Make sure
you wire power to the
outer connectors of the
terminal block and ground
to the middle connector.
Otherwise, you could
damage the dome.
2. Power - Connect 24 VAC from the transformer to the outer terminals on the
power connector. It does not matter which lead goes to which terminal.
If you are wiring more than one dome from the same transformer, it is impor-
tant to wire the power connector in each dome the same way. That is, the
wiring from one side of the transformer must be connected to the same con-
nector on each dome. If you reverse the wiring, the cameras will be out of
phase with each other and may produce what appears to be vertical roll when
switching between cameras. Refer to Figure 10 for a wiring diagram.
3. Video - Connect the coaxial cable to the BNC video connector.
4. Control - If you are using a Coaxitron® controller, control signals will be trans-
mitted over the video coax.
If you are using RS-422 control signals, connect the control lines from the
controller to the circuit board. Connect the wires as follows:
From controller
To 4-Wire terminal on circuit board
RX-
RX+
TX-
TX-
TX+
RX-
RX+
TX+
EXAMPLE: If each
dome requires 20 vA,
three domes require a
60 vA transformer.
CONNECTOR
FOR OPTIONAL
TRANSLATOR
SUBASSEMBLY
HTR/FAN
VIDEO
RS-422
CONTROL
SIGNALS
DOME 1
POWER
1
RX–
RX+
TX–
TX+
2
DOME DRIVE
CONNECTOR
3
4
5
6
7
GND
NO
COM
NC
AUX 2
GND
DOME 2
POWER
AUX 1
FUSE
FAN
24 VAC
MIDDLE
PIN IS
GND
DOME 3
POWER
POWER
(24 VAC ONLY)
1.6 A
Figure 10. Transformer Wiring
Figure 11. Interconnect Circuit Board
Electrical Connections
Pelco Manual C1456M-D (10/98)
19
5. Heater/Fan - This is a factory connection for a heater on outdoor pendant
models.
NOTE: Connect only a low volt-
age device to the relay output.
Maximum current rating of the re-
lay contacts is two amperes.
6. Alarm Inputs - If you need alarm inputs, connect them. The maximum num-
ber of alarm inputs is seven. Refer to Figure 8 for a typical wiring example.
Alarm inputs require a ground signal through a contact closure, such as a
switch.
7. AUX 1 - An AUX 1 command from the controller will activate the relay output.
If you need the relay, wire it as required. Refer to Figure 8. The relay contacts
are shown when AUX 1 is inactive. When an AUX 1 command is issued, the
relay contacts will reverse and remain latched until a clear command is is-
sued.
CAUTION: The maxi-
mum output of AUX 2 is
150 mA. If you connect a
device that draws more
current, you could destroy
the output transistor. The
output is intended to
drive logic circuits or low-
current devices. If higher
current is required, con-
nect the output to a relay.
8. AUX 2 - An AUX 2 command from the controller will place a ground at the
output of AUX 2 to operate the device connected to it. The output will remain
latched until a clear command is issued. If you need the AUX 2 output, wire it
as required. Refer to Figure 8 for typical wiring examples. TheAUX 2 output is
an open collector transistor driver which is capable of passing a maximum of
150 mAat 32 VDC. It is capable of driving TTL logic circuits or low-current reed
relays. If you use an external relay, make sure that both the supply voltage and
the current requirements are well below the maximum of 32 VDC and 150 mA.
Exceeding these values will cause permanent damage to the dome. If you are
not familiar with open collector drive requirements, contact Pelco technical
support for assistance.
CAUTION: Leave ad-
equate slack in the wiring
to permit the door to open
without pulling on the con-
nectors.
9. Close the door and tighten the thumbscrew securely.
Proceed to Section 3.5, DOME DRIVE.
3.5 DOME DRIVE
NOTE: For Coaxitron® control,
SW2 is not used and all switches
must be OFF.
1. Turn on power to the back box. The red LED should light to indicate power.
If the LED does not light, correct the trouble before proceeding. Refer to Sec-
tion 6.0, TROUBLESHOOTING.
If the light is operating, you may either leave the power on and continue with
the installation, or you may turn the power off before proceeding further.
2. Set the switches on the bottom of the dome drive. Refer to Figure 12 and Table
C for the settings for SW1.
Refer to Figure 12 and Tables D and E for the settings for SW2.
3. Install the dome drive in the back box: Line up the green drive eject tab on the
dome drive with the green label on the back box and the red static tab with the
red label on the back box. Raise the dome drive into the back box and push on
the ends of the tabs until they both click into place on the back box.
CAUTION: Make sure
the dome drive locks into
place. Tug downward on
the dome drive with mod-
erate pressure to ensure
that it stays in place.
4. Turn on power, if it is not on. Listen for the fan operating. If the fan does not
work, the dome will overheat and shut down. If the fan does not work, return
the back box electronic assembly and dome drive to the factory for repair.
Refer to Section 6.1, BACK BOX ELECTRONIC ASSEMBLY REMOVAL.
Proceed to Section 3.6, LOWER DOME.
20
Pelco Manual C1456M-D (10/98)
Table C. Switch Settings for SW1
Control Type
Switch Setting
SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8
Coaxitron®
P-Type Control
D-Type Control
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF*
OFF**
OFF**
OFF**
NOTES: Switches SW1-3 through SW1-6 MUST be OFF.
D-type control is RS-422 that is compatible with Pelco’s CM6700, MPT9500 and CM8500
controllers or with American Dynamics control systems using the AD2083 Translator.
P-type control is RS-422 that is compatible with Pelco’s CM6700/CM9750/CM9760 control systems.
* OFF- Use with controllers that have more than 32 presets.
ON- Use with American Dynamics controllers (32 presets).
** OFF - Use with all control systems except CM9502 with variable speed keyboards.
For CM9502 with fixed speed keyboards, set switch OFF.
ON - Use with CM9502 with variable speed keyboards for smoother joystick control.
SW 1
ON
1
1
8
OFF
ON
8
OFF
SW 1
SW 2
ON
1 2 3 4 5 6 7 8
OFF
ON
1 2 3 4 5 6 7 8
SW 2
OFF
Figure 12. Switch Locations
Pelco Manual C1456M-D (10/98)
21
Table D. Switch Settings for SW2 – P-Type Control
NOTES: For Coaxitron® controls, all switches on SW2 MUST be OFF.
For D-type control systems, refer to Table E.
Receiver Address
Switch Setting
SW2-3
SW2-1
SW2-2
SW2-4
SW2-5
1
2
3
4
5
6
7
8
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
9
OFF
OFF
ON
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
Baud Rate
Switch Setting
SW2-6
SW2-7
SW2-8
2400
4800
9600
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
22
Pelco Manual C1456M-D (10/98)
Table E. Switch Settings for SW2 – D-Type Control
NOTES: For Coaxitron® controls, all switches on SW2 MUST be OFF.
For P-type control systems, refer to Table D.
Receiver Address
Switch Setting
SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
1
2
3
4
5
6
7
8
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
Continued on next page
Pelco Manual C1456M-D (10/98)
23
Table E. Switch Settings for SW2 – D-Type Control (continued)
Receiver Address
Switch Setting
SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
89
90
91
92
93
94
95
96
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
97
98
99
ON
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
Continued on next page
24
Pelco Manual C1456M-D (10/98)
Table E. Switch Settings for SW2 – D-Type Control (continued)
Receiver Address
Switch Setting
SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
ON
ON
ON
OFF
OFF
Continued on next page
Pelco Manual C1456M-D (10/98)
25
Table E. Switch Settings for SW2 - D-Type Control (continued)
Receiver Address
Switch Setting
SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
OFF
OFF
ON
Continued on next page
26
Pelco Manual C1456M-D (10/98)
Table E. Switch Settings for SW2 - D-Type Control (continued)
Receiver Address
Switch Setting
SW2-1 SW2-2 SW2-3 SW2-4 SW2-5 SW2-6 SW2-7 SW2-8
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
OFF
ON
ON
ON
ON
ON
3.6 LOWER DOME
1. Snap the clip on the end of the trim ring leash into the hole on the lip of the
back box next to one of the mounting screws.
2. Line up the snaps on the trim ring with the mounting screws on the back box.
Snap the trim ring into place on the plastic snap washers on the mounting
screws.
Figure 13. Lower Dome Installation, In-Ceiling Models
Pelco Manual C1456M-D (10/98)
27
4.0 INSTALLATION FOR PENDANT MODELS
4.1 PENDANT-MOUNT INSTALLATION
1. Install the pendant dome mount. Refer to the instructions supplied with the
mount. If the mount is outdoors, make sure it is properly sealed to keep mois-
ture out.
2. Bring the wiring for the dome through the mount. Refer to Section 3.2, WIR-
ING.
3. Refer to Figure 9. Loosen the thumbscrew inside the back box and open the
hinged door.
4. Screw the back box into the mount and bring the wiring into the back box. If
outdoors, apply the provided pipe sealant to the threads on the back box.
5. Attach the wiring to the back box. Refer to Section 3.4, BACK BOX CONNEC-
TIONS.
NOTE: If outdoors, apply Duct
Seal inside the pipe portion of the
back box to prevent moisture or
cold air inside the mount from en-
tering the unit and causing conden-
sation on the dome. Make sure no
moisture has condensed inside the
unit before installing the lower
dome. Duct Seal can be purchased
through local electrical supply
houses.
6. Install the dome drive. Refer to Section 3.5, DOME DRIVE.
7. Remove the O-ring and O-ring lubricant from the parts bag. Apply lubricant to
the O-ring. Install the O-ring in the groove on the trim ring of the lower dome.
8. Refer to Figure 14. Hanging down from the back box is a short cable (the trim
ring leash). Hold up the lower dome near the back box so that the trim ring
leash touches the lower dome. Line up the two screw holes in the trim ring of
the lower dome with the two screw holes in the back box. Place a finger on the
edge of the trim ring where the leash touches the lower dome.
LEASH
SCREW HOLES
(FRONT & BACK)
ATTACH LEASH
TO NEAREST
RETAINER
SCREW
Figure 14. Lower Dome Installation, Pendant Models
28
Pelco Manual C1456M-D (10/98)
9. Look inside the lower dome and note which of the six retainer screws is clos-
est to your finger. Remove this screw and attach the trim ring leash to the
screw. Reinstall the screw securely and make sure the leash will hold the
lower dome.
10. If you are installing an outdoor model, plug the two-pin heater connection in
the lower dome into the mating connector in the back box.
11. Remove the two screws and the tube of Loctite® from the parts bag. Apply a
drop of Loctite® to each screw.
12. Push the lower dome inside the back box, line up the screw holes, and install
the two screws.
4.2 SURFACE-MOUNT INSTALLATION
NOTE: For hard ceilings, such as
concrete, where the wiring must be
installed in surface-mounted con-
duit, use the optional BB5-PCA-BK
(black) or BB5-PCA-GY (gray) Pen-
dant Conduit Adapter.
1. Use a hole saw to drill a hole in the ceiling where you want to hang the pen-
dant dome.
2. Bring the wiring for the dome to the opening. Refer to Section 3.2, WIRING.
3. Refer to Figure 9. Loosen the thumbscrew inside the back box and open the
hinged door.
4. Remove the gasket and the top mount from the back box by taking out the
three screws and lock washers.
5. Attach the back box to the ceiling using #8 hardware (not supplied). Reattach
the cable (trim ring leash) that was attached to one of the screws you removed
in step 4.
6. Attach the wiring to the back box. Refer to Section 3.4, BACK BOX CONNEC-
TIONS.
7. Install the dome drive. Refer to Section 3.5, DOME DRIVE.
8. Remove the O-ring and O-ring lubricant from the parts bag. Apply lubricant to
the O-ring. Install the O-ring in the groove on the trim ring of the lower dome.
9. Refer to Figure 14. Hanging down from the back box is a short cable (the trim
ring leash). Hold up the lower dome near the back box so that the trim ring
leash touches the lower dome. Line up the two screw holes in the trim ring of
the lower dome with the two screw holes in the back box. Place a finger on the
edge of the trim ring where the leash touches the lower dome.
10. Look inside the lower dome and note which of the six retainer screws is clos-
est to your finger. Remove this screw and attach the trim ring leash to the
screw. Reinstall the screw securely and make sure the leash will hold the
lower dome.
11. If you are installing an outdoor model, plug the two-pin heater connection in
the lower dome into the mating connector in the back box.
12. Remove the two screws and the tube of Loctite® from the parts bag. Apply a
drop of Loctite® to each screw.
13. Push the lower dome inside the back box, line up the screw holes, and install
the two screws.
Pelco Manual C1456M-D (10/98)
29
5.0 OPERATION
NOTE: In the following material,
sometimes a number in parenthe-
ses follows a preset. This second
number is for 32-preset mode.
The red LED in the interconnect door in the back box lights when power is turned
on and the fan operates to exhaust heat from inside the back box.
If you have an outdoor pendant model with a heater, the heater elements in the
back box turn on at 70°F (21°C) and turn off at 85°F (29°C). The heater element in
the lower dome turns on at 40°F (4°C) and turns off at 60°F (16°C). The fans in the
back box operate continuously.
5.1 POWER-UP DISPLAY
When the Spectra® (Version 3.0) dome is powered up or reset, the selected proto-
col, revision number, and other information is displayed on the monitor. For ex-
ample, the screen might show the following information:
PELCO SPECT II 3.02
CONFIGURE DONE
Protocol C
The information remains on the monitor until the dome is moved. The information
displayed depends on the selected protocol and the choice made on the menu for
selectable power-up mode, a feature that lets the dome resume a desired condition
upon power-up.As a default, the dome goes to a random position. (Refer to Section
5.11.12, POWER UP MODE).
The control system protocol (C, D, or P) appears. C is for Pelco’s Coaxitron® control
systems. D-type control is RS-422 that is compatible with Pelco’s CM6700, MPT9500
and CM8500 controllers or with American Dynamics control systems using the
AD2083 Translator. P-type control is RS-422 that is compatible with Pelco’s CM6700
and CM9750/CM9760 control systems.
NOTE: The dome will stop oper-
ating if the voltage at the dome
drops below 18 VAC. It will turn
back on and go through its start-
up routine when the voltage ex-
ceeds 18 VAC.
For the D and P protocols, the device address, baud rate, parity (N), number of data
bits (8), and number of stop bits (1) appears. For the D protocol, if the mode for 32
presets is selected (SW1-7 is ON), “32 presets” appears.
If the CM9500 mode is selected (SW1-8 is ON), “CM9500 mode” appears.
5.2 PAN AND TILT FUNCTIONS
Use the joystick on your controller to control pan and tilt functions.
Pan and tilt operation is at a fixed speed with fixed-speed controllers. The speed is
determined by the controller.
Standard pan operation with variable-speed controllers will range from 0.5 to 80
degrees per second, depending on the position of the joystick. In the turbo mode,
pan speed will be 150 degrees per second. When performing preset operations,
pan speed will be 250 degrees per second.
Standard tilt operation with variable-speed controllers will range from 0.5 to 40 de-
grees per second, depending on the position of the joystick. When performing pre-
set operations, tilt speed will be 100 degrees per second. Turbo mode does not
affect the tilt speed.
If the proportional pan mode is enabled (refer to Section 5.11.20, PROPORTIONAL
PAN), the pan (and tilt) speed will depend on the amount of zoom. At telephoto
zoom settings, the pan (and tilt) speeds will be slower for a given amount of joystick
deflection than at wide zoom settings. This keeps the image from moving too fast on
the monitor when there is a large amount of zoom. This slowing does not happen
when going to a preset, but does occur in turbo mode when high zoom is selected.
30
Pelco Manual C1456M-D (10/98)
5.2.1 Auto Flip
When the camera tilts downward and goes just beyond the vertical position, the dome
rotates 180 degrees. When the dome rotates (flips), the camera starts moving upward
as long as you continue to hold the joystick in the down position. Once you let go of the
joystick after the dome rotates, joystick control returns to normal operation.The auto-flip
feature is useful for following a person who passes directly beneath the camera.
You can disable this feature in the auto flip programming menu. Refer to Section
5.11.19, AUTO FLIP.
5.2.2 Scan Speed
Scan speed is adjustable from 1 to 40 degrees per second through the program-
ming menu.
5.3 ZOOM
NOTE: On some controllers the
zoom speed can be changed. Re-
fer to the documentation for your
controller.
The Spectra® (Version 3.0) dome can magnify an object up to 96 times. The dome
has 12X of optical zoom and 8X of electronic (digital) zoom for a total of 96X zoom.
The amount of zoom can be set for 12X, 24X, 48X, or 96X. Software controls the
amount of zoom. Refer to Section 5.11.3, ZOOM LIMIT, to program the zoom limits.
12X or 24X Zoom
Press the Zoom Tele button to magnify an object up to 12 or 24 times. Hold down
the button until the desired picture is obtained.
48X or 96X Zoom
1. Press the Zoom Tele button until the picture reaches 24X zoom.
2. Release the button.
3. Within one second hold down the button again. Hold down the button until the
desired picture is obtained.
5.4 PRESET FUNCTIONS
NOTE: If you are using the Spec-
tra® (Version 3.0) dome’s alarm in-
puts, presets 1-7 must be reserved
for alarm operations. For more in-
formation, refer to Section 5.8,
ALARMS.
The Spectra® (Version 3.0) dome is capable of going to 64 preset locations, each
with a 20-character label. The presets are numbered 1-32 and 35-66.
Refer to the documentation for your control system for programming presets.
When a preset operation is performed, the amount of error in moving to the pan and
tilt position a is 1/2 degree. If you command the dome to go to an undefined preset,
erratic operation may result.
NOTE: For AMERICAN DYNAM-
ICS controllers with only 32 pre-
sets, set switch SW1-7 on the
dome drive in the ON position.
When SW1-7 is ON, preset
Presets 33 and 34 are fixed commands, meaning that you cannot program them.
Preset 33 is the “flip” command, which will pan the dome drive 180 degrees from
the position it is at. Preset 34 is the “pan zero” command, which will direct the dome
drive to the factory-determined zero reference point.
The following presets are reserved for special functions:
99 becomes 32
98 becomes 31
97 becomes 30
96 becomes 29
95 becomes 28
93 becomes 26
92 becomes 25
91 becomes 24
90 becomes 23
Preset
1
Function
Park (Section 5.11.22)
1-7
33
34
90-93
95
Alarms, if used (Section 5.8)
Flip command (Section 5.4)
Pan zero command (Section 5.4)
Limit stops (Sections 5.5 and 5.11.21)
Select camera programming menu (Section 5.11.1)
Stop a scan (Section 5.5)
96
97-99
Activate scanning (Section 5.5)
If the limit stops are turned off (refer
to Section 5.11.21.1), presets 23-
26 can be used as regular presets.
Pelco Manual C1456M-D (10/98)
31
5.5 RANDOM, FRAME, AND AUTO SCANNING
Program preset 97 (30) to start random scanning. Program preset 98 (31) to acti-
vate frame scanning (three seconds of scanning followed by a three-second pause).
Program preset 99 (32) to start auto (continuous) scanning.
NOTE: In the following material,
sometimes a number in parenthe-
ses follows a preset. This second
number is for 32-preset mode.
Scan limit stops are controlled by software. Refer to Section 5.11.21, LIMIT STOPS,
to program the scan limit stops.
When the dome reaches a scan limit stop, it will immediately reverse direction.
Program preset 96 (29) to stop a scan. Any pan/tilt or lens command also will stop
a scan.
5.6 ZONES
The Spectra® (Version 3.0) dome is capable of eight zones, each with a 20-char-
acter label. Depending on the controller, you can define the zone size and define
any zone as “blanked” for video when the camera pans into the zone area. (Zone
sizing and blanking work with the CM8500, CM9500, and MPT9500; but do not
work with the CM6700 and System 9760™.) If zone labels are turned off, the sys-
tem displays the message, VIDEO BLANK, to indicate the video is being blanked
and is not failing. (Refer to Section 5.11.18, ZONE BLANK, for instructions.) For
other information on programming zones, refer to the documentation for your con-
trol system.
5.7 PATTERNS
The Spectra® (Version 3.0) dome can do either one full pattern (1.5, 3, or 6 minutes
long) or two half patterns (.75, 1.5, or 3 minutes long). (With a CM6700 controller,
the dome can do either two patterns up to 30 seconds long or one pattern up to 60
seconds long.) This pattern can consist of any standard pan and tilt or lens com-
mand. Presets, flip, and turbo are not allowed in a pattern. Zone scan can be en-
abled while running a pattern.
NOTE: Changing the length
erases all stored patterns.
Refer to the documentation for your control system to program and run patterns.
5.8 ALARMS
The Spectra® (Version 3.0) dome has seven alarm inputs, which can be designated
as either high or low priority through its programming menu. When an alarm is
received, the dome moves to the preset position that corresponds to the alarm
number. For example, if alarm 3 is activated, the dome moves to preset 3. There is
no indication at the controller that an alarm has been received, other than the view
displayed on the monitor.
NOTE: If any of presets 1-7 are
not used for alarms, they can be
used as regular presets. However,
if they are being used for alarms,
they should not be used for any-
thing else.
The high priority setting (if set on the programming menu) is significant when more
than one alarm is activated. If priority in alarms is not required, leave all alarms in
the low setting.
•
If the activated alarm inputs have the same priority–all low or all high–then the
dome will sequence between the presets that correspond to the alarm num-
bers.
•
If the activated alarm inputs have different priorities–for example, one is high
and four are low–the dome goes only to the high. It remains fixed on the high
and only goes to the low after the high has been cleared.
32
Pelco Manual C1456M-D (10/98)
In certain situations, the dome will respond as follows:
•
•
If a preset has not been set, but an alarm is connected: the dome will go to a
factory preset that will not be the desired position.
If one alarm is a preset and another is a pattern and both are received: the
dome will alternate between them.
An alarm clears by returning to its former (off) state.
Depending on choices made on the programming menu, the dome can respond to
an alarm by running one of the patterns below. (Refer to Section 5.7, PATTERNS,
for more information.)
•
•
•
Run full pattern
Run half pattern 1
Run half pattern 2
When sequencing between presets, the dwell time depends on the time set on the
Alarm Dwell submenu for that preset. After the dwell time expires, the dome imme-
diately does one of the following:
•
If the resume feature was selected on the programming menu and there are
no other alarms activated, the dome resumes its prior activity. So, it might
return to its previous position or resume a scan or pattern.
•
If there are other alarms activated, the dome goes to them.
If you move the joystick to pan or tilt the dome, or if you issue a lens command while
there is an alarm, the pan and tilt or lens command overrides the alarm. Sixty sec-
onds after the last pan and tilt or lens command, the dome will return to the alarm
preset if the alarm is still active.
5.9 AUXILIARY OUTPUTS
An AUX 1 command from the controller will activate the relay in the dome and
operate the device that is connected to the relay. The relay will remain latched until
a clear command is issued.
AnAUX 2 command from the controller will place a ground at the output of AUX 2 to
operate the device that is connected to it. The output will remain latched until a clear
command is issued. Refer to Section 3.4, BACK BOX CONNECTIONS, for precau-
tions regarding the use of the AUX 2 output.
The output relay can also be programmed so that it is activated when any alarm
input is activated. When latching (toggling) is selected on the programming menu,
giving the AUX 1 command from the controller changes the state of the AUX (for
example, if it was on, this turns it off). The clear command from the controller will
turn the AUX off in the latching or toggle mode.
5.10 PARK
If the Spectra® (Version 3.0) dome does not receive any commands for a specified
period of time (refer to Section 5.11.22, PARK TIME MINUTES), the dome will go to
preset 1 and park. If the time specified is zero, or if preset 1 has not been pro-
grammed, the dome will not park. The default is zero minutes.
Pelco Manual C1456M-D (10/98)
33
5.11 PROGRAMMING THE SPECTRA™ (VERSION 3.0)
The Spectra® (Version 3.0) dome can be programmed for the following functions:
AGC (automatic gain control) Auto park time
Power-up mode
Proportional panning
Scan speed
Alarm dwell
Alarm pattern
Alarm priority
Alarm resume
Auto flip disable
Auto focus
Auxiliary relays
Backlight compensation
Camera reset
Gain
Limit stops
Pattern length
Sharpness
Shutter speed
Video zone blanking
White balance
Auto iris
Power line synchronization Zoom limit
The main menu contains six secondary menus:
•
•
•
•
•
•
Camera
Line Sync
Power Up Mode
Aux
Alarms, Zone Blank
Other
Each secondary menu has submenus, which are structured as shown below. Be-
side the menu items are section numbers in parentheses showing where the func-
tions are explained.
1. Camera
First Camera Submenu
Backlight comp (5.11.2)
Zoom limit (5.11.3)
Reset camera (5.11.4)
Gain/AGC (5.11.5)
AGC mode
Second Camera Submenu
Shutter speed (5.11.7)
Auto focus mode (5.11.8)
Sharpness (5.11.9)
Auto sharpness
Sharpness
Gain
Auto-iris (5.11.6)
Auto-iris mode
White balance (5.11.10)
Auto white bal
R-B white bal
Auto-iris level
M-G white bal
Auto-iris peak
Prev (to first camera submenu)
Next (to second camera submenu)
2. Line Sync (5.11.11)
Line sync
Line sync phase
3. Power Up (5.11.12)
Power Up
4. Aux (5.11.13)
Aux 1 mode
Aux 2 mode
5. Alarm, Zone Blank
Alarm resume (5.11.14)
Alarm dwell sec (5.11.15)
Alarm priority (5.11.16)
Alarm pattern (5.11.17)
Zone blank (5.11.18)
6. Other
Auto flip (5.11.19)
Proportional pan (5.11.20)
Limit stops (5.11.21)
Park time minutes (5.11.22)
Scan speed deg/s (5.11.23)
Pattern length (5.11.24)
The following sections explain how to program the Spectra® (Version 3.0) dome
using the menu choices.
34
Pelco Manual C1456M-D (10/98)
5.11.1 Main Menu Access
You can call up the main menu on your monitor by programming (setting or creat-
ing) preset 95 (28 if in 32-preset mode; refer to Section 5.4).
Programming preset 95 varies according to the type of controller you are using.
Instructions for programming preset 95 are given below for various controllers.
CM6700
1. Enter the number of the Spectra® (Version 3.0) camera and press the CAM key.
2. Enter 95 and hold the PRESET key for two seconds.
3. In the Edit Preset menu, arrow to SET and press theACK key. The main menu
appears.
CM8500
1. Enter the number of the Spectra® (Version 3.0) camera and press the CAM key.
2. Highlight PRESET in the Camera menu and hold down the joystick button until
the Set Presets prompt appears.
3. Enter 95 and press the PRESET key. The main menu appears.
CM9500
1. Enter the number of the Spectra® (Version 3.0) camera and press the CAM key.
2. Press the SELECT key twice.
3. Highlight CAM in the Setup menu and press the SELECT key.
4. Highlight PRESET in the Camera menu and press the SELECT key.
5. Enter 95 and press the F1 key. The main menu appears.
CM9750
1. Turn the KEY SWITCH to the ON position.
2. Press the PROG key. PROGRAM appears on the LCD display.
3. Press the PRES key. The PRESET prompt appears.
4. Enter 95 and press the ENTER key. The main menu appears.
5. Turn the KEY SWITCH to the OFF position.
CM9760
1. In the default menu, select DEF. The Define Submenu appears.
2. Enter your four-digit PIN.
3. Enter 95 and select PRST. The main menu appears on the monitor.
4. Select the Quit icon to return to the default menu.
MPT9500
Standard Coaxitron® Mode
1. Enter 95 and press the PRESET SET key.
2. Position the asterisk in the YES row and press the F1 key. The main menu
appears.
Extended Coaxitron®or RS-485 Mode
1. Enter 95 and press the PRESET SET key.
2. Press the F2 key. The main menu appears.
Pelco Manual C1456M-D (10/98)
35
5.11.2 Backlight Compensation
There are two backlight compensation modes: on and off.
Backlight compensation allows the Spectra® (Version 3.0) dome to compensate for
bright light behind the object you want to view. With backlight compensation On, the
Spectra® (Version 3.0) dome will use only the center 10 percent of the picture for
adjusting the iris (refer to Figure 15). If there is a bright light source outside of this
area, it will wash out to white. The camera will adjust the iris so that the object in the
sensitive area is properly exposed.
Non-Sensitive Area
Sensitive
Area
To change the backlight compensation mode:
1. Program Preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET
FUNCTIONS) to access the main menu (refer to Section 5.11.1, MAIN MENU
ACCESS). The main menu will appear.
Figure 15. Backlight Compensation
2. If the cursor (>) is not beside Camera, move the joystick up or down to position
the cursor beside Camera.
3. Press the Iris Open button to enter the Camera submenu.
4. Move the joystick up or down to position the cursor beside Backlight Comp.
5. Press the Iris Open button on your keyboard. A star will appear beside Back-
light Comp and the cursor will move to the right beside the word On or Off.
6. Move the joystick up or down to toggle between On and Off.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL- Press the Iris Close button if you do not want to change the setting.
5.11.3 Zoom Limit
The Spectra® (Version 3.0) dome can magnify an object up to 96 times. The dome
has 12X optical zoom and 8X of electronic (digital) zoom for a total of 96X zoom.
The amount of zoom can be set for 12X, 24X, 48X, or 96X.
To change the zoom limit:
1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET
FUNCTIONS) to access the main menu (refer to Section 5.11.1, MAIN MENU
ACCESS). The main menu will appear.
2. If the cursor (>) is not beside Camera, move the joystick up or down to position
the cursor beside Camera.
3. Press the Iris Open button to enter the Camera submenu.
4. Move the joystick up or down to position the cursor beside Zoom Limit.
5. Press the Iris Open button. A star will appear beside Zoom Limit and the cur-
sor will move to the right beside the current zoom limit.
6. Move the joystick up or down to choose the zoom limit.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL- Press the Iris Close button if you do not want to change the setting.
36
Pelco Manual C1456M-D (10/98)
5.11.4 Reset Camera
Resetting the camera returns the following settings to their defaults.
Setting:
Auto-focus mode
Default:
Auto
Gain/AGC
AGC mode
Gain
Auto
No default setting
Backlight comp
Shutter speed
Auto-iris
Off
Auto
Mode
Auto
Level
Peak
Default value depends on type of camera
Default value depends on type of camera
White balance
Auto white balance
R-B white balance
M-G white balance
Sharpness
Auto sharpness
Sharpness
On
No default setting
No default setting
On
No default setting
When the camera is reset, the following settings are not changed: zoom limit, park
time, auto flip disable, limit stops, and proportional panning.
Turning off power to the Spectra® (Version 3.0) dome does not reset the camera.
Camera settings are retained in memory, and when the power is turned back on,
the settings will be the same as they were when it was turned off.
To reset the camera:
1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET
FUNCTIONS) to access the main menu (refer to Section 5.11.1, MAIN MENU
ACCESS). The main menu will appear.
2. If the cursor (>) is not beside Camera, move the joystick up or down to position
the cursor beside Camera.
3. Press the Iris Open button to enter the Camera submenu.
4. Move the joystick up or down to position the cursor beside Reset Camera.
5. Press the Iris Open button to reset the camera.
Pelco Manual C1456M-D (10/98)
37
5.11.5 Gain/AGC
5.11.5.1 AGC Mode
There are three AGC (Automatic Gain Control) modes: auto, on, and off.
In the auto mode, the Spectra® (Version 3.0) dome automatically adjusts the gain
- the amount of amplification the camera places on its video information in order
to obtain a full 1-volt peak-to-peak video signal out. If the iris is manually opened
to its wide-open position and the picture is weak, the AGC can be turned off and
the gain increased manually to improve the picture. For instructions on how to do
this, refer to Section 5.11.6, AUTO IRIS. When you close the iris, the AGC will
turn back on automatically when the lens iris starts closing.
In the on mode the AGC is on all the time.
In the off mode the AGC is off.
To change the AGC mode:
1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET
FUNCTIONS) to access the main menu (refer to Section 5.11.1, MAIN MENU
ACCESS). The main menu will appear.
2. If the cursor (>) is not beside Camera, move the joystick up or down to position
the cursor beside Camera.
3. Press the Iris Open button to enter the Camera submenu.
4. Move the joystick up or down to position the cursor beside Gain/AGC.
5. Press the Iris Open button to enter the Gain/AGC submenu.
6. Move the joystick up or down to position the cursor beside AGC mode.
7. Press the Iris Open button on your keyboard. A star will appear beside AGC
mode and the cursor will move to the right beside the word Auto, On, or Off.
8. Move the joystick up or down to position the cursor beside Auto, On, or Off.
9. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL- Press the Iris Close button if you do not want to change the setting.
5.11.5.2 Gain
The gain adjusts the signal level of the video output. Increasing the gain in low light
conditions will increase the level of noise in the picture.
To change the gain:
1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET
FUNCTIONS) to access the main menu (refer to Section 5.11.1, MAIN MENU
ACCESS). The main menu will appear.
2. If the cursor (>) is not beside Camera, move the joystick up or down to position
the cursor beside Camera.
3. Press the Iris Open button to enter the Camera submenu.
4. Move the joystick up or down to position the cursor beside Gain/AGC.
5. Press the Iris Open button to enter the Gain/AGC submenu.
6. Move the joystick up or down to position the cursor beside Gain.
7. Press the Iris Open button on your keyboard. Astar will appear beside Gain and
the cursor will move to the right beside the current gain setting (a numeric value).
8. Move the joystick up or down to change the gain. As you change the gain, the
picture on your monitor will get brighter or darker.
9. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL- Press the Iris Close button if you do not want to change the setting.
38
Pelco Manual C1456M-D (10/98)
5.11.6 Auto Iris
There are three settings for auto iris: mode, level, and peak.
To change the settings for auto iris:
1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET
FUNCTIONS) to access the main menu (refer to Section 5.11.1, MAIN MENU
ACCESS). The main menu will appear.
2. If the cursor (>) is not beside Camera, move the joystick up or down to position
the cursor beside Camera.
3. Press the Iris Open button to enter the Camera submenu.
4. Move the joystick up or down to position the cursor beside Auto-Iris.
5. Press the Iris Open button on your keyboard. Another menu will appear with
auto-iris mode, level, and peak selections.
6. Move the joystick up or down to position the cursor beside one of the choices.
Press the Iris Open button on your keyboard.
MODE - The cursor moves to one of two choices: Auto or Off. In theAuto mode, the
iris is automatically adjusted to produce a constant video output as determined by
the Level setting below. In the Off mode, auto iris is disabled, and control is always
manual. Move the joystick up or down to toggle betweenAuto and Off. Press the Iris
Open button to select the choice, or press the Iris Close button if you do not want to
change the setting.
LEVEL - The cursor moves to a numeric value, which the Spectra® (Version 3.0)
dome uses to try to maintain a certain light level. Changing the value of the Level
setting will change the video level to which the auto iris adjusts. This setting should
be adjusted if the video level in the auto iris mode is too bright or too dark. Move the
joystick up or down to a value. Press the Iris Open button to select the value, or
press the Iris Close button if you do not want to change the setting.
PEAK - The cursor moves to a numeric value. Increasing this value will cause the
auto iris circuit to react more to highlights or “peaks” in the picture. Decreasing this
value will cause it to use the average video level to adjust the iris. Move the joystick
up or down to a value. Press the Iris Open button to select the value, or press the
Iris Close button if you do not want to change the setting.
If auto iris is in the auto mode, it remains that way until you manually open or close
the iris. The dome will return to auto iris when it is panned or tilted more than 15
degrees.
If there is not enough light for a good picture when the iris is wide open, you can
increase the gain of the camera to improve the picture. To do this:
1. The AGC mode (Section 5.11.5.1, AGC MODE) must be in either the Auto or
Off mode. The following steps will not work if the AGC mode is On.
2. Hold down the Iris Open button until the iris is wide open.
3. Release the button.
4. Within one second, hold down the button again. This will start increasing the
camera gain. Hold down the button until a desirable picture is obtained or the
maximum gain is reached.
Pelco Manual C1456M-D (10/98)
39
5.11.7 Shutter Speed
There are nine electronic shutter speed settings:
Auto
1/100
1/120
1/500
1/1000
1/2000
1/4000
1/10,000
1/30,000
In the Auto setting the camera controls the shutter speed automatically.
Increasing the shutter speed lowers the light sensitivity, but rapidly moving objects
will be less blurred as the speed is increased.
To change the electronic shutter speed settings:
1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET
FUNCTIONS) to access the main menu (refer to Section 5.11.1, MAIN MENU
ACCESS). The main menu will appear.
2. If the cursor (>) is not beside Camera, move the joystick up or down to position
the cursor beside Camera.
3. Press the Iris Open button to enter the Camera submenu.
4. Move the joystick up or down to position the cursor beside Next.
5. Press the Iris Open button to go to the next camera submenu.
6. Move the joystick up or down to position the cursor beside Shutter Speed.
7. Press the Iris Open button on your keyboard.
8. A star will appear beside Shutter Speed and the cursor will move to the right
beside the current shutter speed.
9. Move the joystick up or down to choose the shutter speed.
10. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL- Press the Iris Close button if you do not want to change the setting.
40
Pelco Manual C1456M-D (10/98)
5.11.8 Auto-Focus Mode
There are two auto-focus modes: auto and off.
If auto focus is in the auto mode, pressing the Focus Far or Focus Near button will
place the focus in the manual mode. The dome will return to auto focus if you pan or
tilt the unit or do a zoom function.
If the mode is set to off, the dome will operate in the manual mode with one excep-
tion. If you issue a command to go to a preset, auto focus will turn on and remain on
until you press the Focus Far or Focus Near button.
To change the mode:
1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET
FUNCTIONS) to access the main menu (refer to Section 5.11.1, MAIN MENU
ACCESS). The main menu will appear.
2. If the cursor (>) is not beside Camera, move the joystick up or down to position
the cursor beside Camera.
3. Press the Iris Open button to enter the Camera submenu.
4. Move the joystick up or down to position the cursor beside Next.
5. Press the Iris Open button to go to the next camera menu.
6. Move the joystick up or down to position the cursor beside Auto-Focus Mode.
7. Press the Iris Open button on your keyboard. A star will appear beside Auto-
Focus Mode and the cursor will move to the right beside the word Auto or Off.
8. Move the joystick up or down to toggle between Auto and Off.
9. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL- Press the Iris Close button if you do not want to change the setting.
5.11.9 Sharpness
There are two modes for adjusting the sharpness of the picture: automatic and manual.
To change the mode:
1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET
FUNCTIONS) to access the main menu (refer to Section 5.11.1, MAIN MENU
ACCESS). The main menu will appear.
2. If the cursor (>) is not beside Camera, move the joystick up or down to position
the cursor beside Camera.
3. Press the Iris Open button to enter the Camera submenu.
4. Move the joystick up or down to position the cursor beside Next.
5
Press the Iris Open button to go to the next camera menu.
6. Move the joystick up or down to position the cursor beside Sharpness.
7. Press the Iris Open button. Another menu will appear with the auto sharpness
and sharpness selections.
8. Move the joystick up or down to position the cursor beside one of the choices.
Press the Iris Open button.
AUTO SHARPNESS - The cursor moves to one of two choices: On or Off. Move the
joystick up or down to toggle between them. Press the Iris Open button to select the
choice, or press the Iris Close button if you do not want to change the setting.
SHARPNESS - The cursor moves to a numeric value. Move the joystick up or down
to a value. As you change the value, you will see the sharpness change. Press the
Iris Open button to select the value, or press the Iris Close button if you do not want
to change the setting. If the Auto Sharpness is on, it will change to off when you
select a new value.
Pelco Manual C1456M-D (10/98)
41
5.11.10 White Balance (Color Cameras Only)
There are three settings for white balance: auto, red-blue, and magenta-green.
To change the white balance settings:
1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET
FUNCTIONS) to access the main menu (refer to Section 5.11.1, MAIN MENU
ACCESS). The main menu will appear.
2. If the cursor (>) is not beside Camera, move the joystick up or down to position
the cursor beside Camera.
3. Press the Iris Open button to enter the Camera submenu.
4. Move the joystick up or down to position the cursor beside Next.
5. Press the Iris Open button to go to the next camera submenu.
6. Move the joystick up or down to position the cursor beside White Balance.
7. Press the Iris Open button on your keyboard. Another menu will appear with
the auto, red-blue, and magenta-green selections.
8. Move the joystick up or down to position the cursor beside one of the choices.
Press the Iris Open button on your keyboard.
AUTO WHITE BALANCE - The cursor moves to one of two choices: Auto or Off. Move
the joystick up or down to toggle between them. Press the Iris Open button to select the
choice, or press the Iris Close button if you do not want to change the setting.
R-B WHITE BALANCE - The cursor moves to a numeric value. Move the joystick up
or down to a value. As you change the value, you will see the color change on your
monitor. Press the Iris Open button to select the value, or press the Iris Close button
if you do not want to change the setting. If Auto White Balance is on, it will change
to off when you select a new value.
M-G WHITE BALANCE - The cursor moves to a numeric value. Move the joystick
up or down to a value. As you change the value, you will see the color change on
your monitor. Press the Iris Open button to select the value, or press the Iris Close
button if you do not want to change the setting. If Auto White Balance is on, it will
change to off when you select a new value.
42
Pelco Manual C1456M-D (10/98)
5.11.11 Line Synchronization
You can turn the line synchronization on or off.
If it is on, you can adjust the synchronization of the power line voltage so that it is in
phase with other cameras. If cameras are out of phase with each other, they may
produce what appears to be vertical roll when switching between cameras.
If it is off, the Spectra® (Version 3.0) dome synchronizes to an internal clock.
To change the line synchronization settings:
1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET
FUNCTIONS) to access the main menu (refer to Section 5.11.1, MAIN MENU
ACCESS). The main menu will appear.
2. If the cursor (>) is not beside Line Sync, move the joystick up or down to
position the cursor beside Line Sync.
3. Press the Iris Open button on your keyboard. Another menu will appear with
the Line Sync and Line Sync Phase selections.
4. Move the joystick up or down to position the cursor beside one of the choices.
LINE SYNC - The cursor moves to one of two choices: On or Off. Move the joystick
up or down to toggle between them.
Press the Iris Open button to select the choice. If you changed to Off, the camera
may reset itself as it adjusts to the new synchronization. If the camera resets, it will
only affect the line synchronization. It willnot change any other camera parameters,
such as auto focus or auto iris.
Press the Iris Close button if you do not want to change the setting.
LINE SYNC PHASE - The cursor moves to a numeric value. Move the joystick up or
down to change the value.
Press the Iris Open button to select the choice. The value represents the phase angle
in tenths of a degree between 0 degrees and 359 degrees. For example, 900 is 90
degrees, 1200 is 120 degrees, and 2400 is 240 degrees. Press the Iris Open button
on your keyboard to select your choice. The Line Sync setting will change to On. The
camera may reset or the picture on your monitor may wiggle when you change the
phase angle. If the camera resets, it will only affect the line synchronization. It will not
change any other camera parameters, such as auto focus or auto iris.
Press the Iris Close button if you do not want to change the setting.
5.11.12 Power Up Mode
This feature lets the dome resume a desired condition following power-up. The
menu includes the following choices:
•
Default–On power-up, the dome goes through a configuration cycle and stops
at zero reference, showing “Configuration Done,” and address and mode set-
tings on the screen.
•
•
•
•
•
•
•
Park–The dome moves to preset 1 when the power-up sequence finishes.
The only text on the screen is the preset label (if any is programmed).
Scan Auto–The dome initiates scan mode when the power-up sequence fin-
ishes. Again, there is no text.
Scan Frame–The dome initiates a frame scan when the power-up sequence
finishes.
Scan Rand–The dome initiates a random scan when the power-up sequence
finishes.
Full Pat–The dome initiates its programmed pattern when the power-up se-
quence finishes. The length can be set to 1.5, 3, or 6 minutes.
Half Pat 1–The dome initiates the first half-pattern when the power-up se-
quence finishes. The length can be set to .75, 1.5, or 3 minutes.
Half Pat 2–The dome initiates the second half-pattern when the power-up
sequence finishes. The length can be set to .75, 1.5, or 3 minutes.
The default setting is Default.
Pelco Manual C1456M-D (10/98)
43
To select the power-up mode:
1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4,PRESET
FUNCTIONS) to access the main menu (refer to Section 5.11.1). The main
menu will appear.
2. If the cursor (>) is not beside Power Up Mode, move the joystick up or down to
position the cursor beside Power Up Mode.
3. Press the Iris Open button to enter the Power Up Mode submenu.
4. Move the joystick up or down to cycle through the selections. Stop on the item
you want to select.
5.
SELECT – Press the Iris Open button on your keyboard to select your choice.
CANCEL- Press the Iris Close button if you do not want to change the setting.
5.11.13 AUX Mode
This feature defines the output relay as either Normal (under control of the head
end), Latching (pressing the AUX key turns on the AUX and the next press of the
AUX key turns it off), or Alarm (any alarm input activates the AUX).
To change the AUX mode:
1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET
FUNCTIONS) to access the main menu (refer to Section 5.11.1, MAIN MENU
ACCESS). The main menu will appear.
2. If the cursor (>) is not beside AUX, move the joystick up or down to position the
cursor beside AUX.
3. Press the Iris Open button to enter the AUX submenu.
4. Move the joystick up or down to position the cursor next to either Aux 1 mode
or Aux 2 mode.
5. Press the Iris Open button. The cursor will move to the right beside the word
Normal, Latching, or Alarm.
6. Move the joystick up or down to toggle between Normal, Latching, or Alarm.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL- Press the Iris Close button if you do not want to change the setting.
5.11.14 Alarm Resume
This mode lets the dome resume its previous activity (scan, pattern, or previous
position) after all alarms are cleared.
To change the alarm resume mode:
1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET
FUNCTIONS) to access the main menu (refer to Section 5.11.1, MAIN MENU
ACCESS). The main menu will appear.
2. If the cursor (>) is not beside Alarms, Zone Blank, move the joystick up or
down to position the cursor beside Alarms, Zone Blank.
3. Press the Iris Open button to enter the Alarms, Zone Blank submenu.
4. Move the joystick up or down to position the cursor beside Alarm Resume.
5. Press the Iris Open button. The cursor will move to the right beside the word
On or Off.
6. Move the joystick up or down to toggle between On or Off.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL- Press the Iris Close button if you do not want to change the setting.
44
Pelco Manual C1456M-D (10/98)
5.11.15 Alarm Dwell
This is the minimum time the Spectra® (Version 3.0) will stay at an alarm even if the
alarm is present for less than this amount of time.
To change the alarm dwell:
1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET
FUNCTIONS) to access the main menu (refer to Section 5.11.1, MAIN MENU
ACCESS). The main menu will appear.
2. If the cursor (>) is not beside Alarms, Zone Blank, move the joystick up or
down to position the cursor beside Alarms, Zone Blank.
3. Press the Iris Open button to enter the Alarms, Zone Blank submenu.
4. Move the joystick up or down to position the cursor beside Alarm Dwell sec.
5. Press the Iris Open button. The cursor will move to the right beside the num-
ber of seconds for the alarm dwell time.
6. Move the joystick up or down and hold to cycle through 1-200 seconds in one-
second increments.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL- Press the Iris Close button if you do not want to change the setting.
5.11.16 Alarm Priority
This feature lets you set alarm inputs as either high or low priority. A high priority
alarm will not release to a low priority alarm. Alarms will release or sequence be-
tween low priority alarms only if no high priority alarm exists. (Refer to Section 5.8,
ALARMS, for more information.)
To change alarm priority:
1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET
FUNCTIONS) to access the main menu (refer to Section 5.11.1, MAIN MENU
ACCESS). The main menu will appear.
2. If the cursor (>) is not beside Alarms, Zone Blank, move the joystick up or
down to position the cursor beside Alarms, Zone Blank.
3. Press the Iris Open button to enter the Alarms, Zone Blank submenu.
4. Move the joystick up or down to position the cursor beside Alarm Priority.
5. Press the Iris Open button to enter the Alarm Priority submenu.
6. Move the joystick up or down to position the cursor beside the number of the
alarm input for which you want to set the priority.
7. Press the Iris Open button. The cursor will move to the right beside the word
High or Low.
8. Move the joystick up or down to toggle between the words High and Low.
9. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL- Press the Iris Close button if you do not want to change the setting.
Pelco Manual C1456M-D (10/98)
45
5.11.17 Alarm Pattern
In response to an alarm, the Spectra® (Version 3.0) dome can do either one full
pattern (1.5, 3, or 6 minutes long) or two half patterns (.75, 1.5, or 3 minutes long).
You can choose one of the following for each of the seven alarm inputs:
NOTE:Pattern length is set on the
secondary menu entitled Other.
•
•
Full Pat (run full pattern)
Half Pat 1 (run half pattern 1)
•
•
Half Pat 2 (run half pattern 2)
No Pattern
To change the alarm pattern:
1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET
FUNCTIONS) to access the main menu (refer to Section 5.11.1, MAIN MENU
ACCESS). The main menu will appear.
2. If the cursor (>) is not beside Alarms, Zone Blank, move the joystick up or
down to position the cursor beside Alarms, Zone Blank.
3. Press the Iris Open button to enter the Alarms, Zone Blank submenu.
4. Move the joystick up or down to position the cursor beside Alarm Pattern.
5. Press the Iris Open button to enter the Alarm Pattern submenu.
6. Move the joystick up or down to position the cursor beside the number of the
alarm input for which you want to set the pattern.
7. Press the Iris Open button. The cursor will move to the right beside the words
Full Pat, Half Pat 1, Half Pat 2, or No Pattern.
8. Move the joystick up or down to toggle between the choices.
9. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL- Press the Iris Close button if you do not want to change the setting.
5.11.18 Zone Blank
This feature lets you define any of eight zones as blanked for video when the cam-
era pans into the zone area. The choices are On and Off. On means video blanking
is in effect. The default is Off.
To change the blank zone setting:
1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET
FUNCTIONS) to access the main menu (refer to Section 5.11.1, MAIN MENU
ACCESS). The main menu will appear.
2. If the cursor (>) is not beside Alarms, Zone Blank, move the joystick up or
down to position the cursor beside Alarms, Zone Blank.
3. Press the Iris Open button to enter the Alarms, Zone Blank submenu.
4. Move the joystick up or down to position the cursor beside Zone Blank.
5. Press the Iris Open button to enter the Zone Blank submenu.
6. Move the joystick up or down to position the cursor beside the number of the
zone for which you want to set the blank option.
7. Press the Iris Open button. The cursor will move to the right beside the word
On or Off.
8. Move the joystick up or down to toggle between the words On and Off.
9. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL- Press the Iris Close button if you do not want to change the setting.
46
Pelco Manual C1456M-D (10/98)
5.11.19 Auto Flip
There are two auto flip modes: on or off.
When the auto flip mode is on, the auto flip feature is enabled. When it is off, the
feature is disabled.
To change the auto flip mode:
1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET
FUNCTIONS) to access the main menu (refer to Section 5.11.1, MAIN MENU
ACCESS). The main menu will appear.
2. If the cursor (>) is not beside Other, move the joystick up or down to position
the cursor beside Other.
3. Press the Iris Open button to enter the Other submenu.
4. Move the joystick up or down to position the cursor beside Auto Flip.
5. Press the Iris Open button. A star will appear beside Auto Flip and the cursor
will move to the right beside the word On or Off.
6. Move the joystick up or down to toggle between On and Off.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL- Press the Iris Close button if you do not want to change the setting.
5.11.20 Proportional Pan
There are two proportional pan modes: on or off.
When proportional pan mode is on, the proportional pan feature is enabled and the
pan (and tilt) speed will depend on the amount of zoom. At telephoto zoom settings,
the pan (and tilt) speeds will be slower for a given amount of joystick deflection than
at wide zoom settings. This keeps the image from moving too fast on the monitor
when there is a large amount of zoom. This slowing does not happen when going to
a preset, but does occur in turbo mode when high zoom is selected.
When the proportional pan mode is off, the feature is disabled and the pan speed
will not depend on the amount of zoom.
To change the proportional pan mode:
1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET
FUNCTIONS) to access the main menu (refer to Section 5.11.1, MAIN MENU
ACCESS). The main menu will appear.
2. If the cursor (>) is not beside Other, move the joystick up or down to position
the cursor beside Other.
3. Press the Iris Open button to enter the Other submenu.
4. Move the joystick up or down to position the cursor beside Proportional Pan.
5. Press the Iris Open button. Astar will appear beside Proportional Pan and the
cursor will move to the right beside the word On or Off.
6. Move the joystick up or down to toggle between On and Off.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL- Press the Iris Close button if you do not want to change the setting.
Pelco Manual C1456M-D (10/98)
47
5.11.21 Limit Stops
There are two types of limit stops:
Manual limit stops
Scan limit stops
When manual limit stops are set, a manual (joystick) pan operation will stop when a
limit stop is reached.
When scan limit stops are set, the dome will reverse direction during random, frame,
or auto scanning when a limit stop is reached.
Limit stops are controlled by software. To set limit stops:
1. Turn on the limit stop mode.
2. Program the limit stops.
5.11.21.1 Turning Limit Stops On or Off
To change the limit stop mode:
1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET
FUNCTIONS) to access the main menu (refer to Section 5.11.1, MAIN MENU
ACCESS). The main menu will appear.
2. If the cursor (>) is not beside Other, move the joystick up or down to position
the cursor beside Other.
3. Press the Iris Open button to enter the Other submenu.
4. Move the joystick up or down to position the cursor beside Limit Stops.
5. Press the Iris Open button. A star will appear beside Limit Stops and the cur-
sor will move to the right beside the word On or Off.
6. Move the joystick up or down to toggle between On and Off.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL- Press the Iris Close button if you do not want to change the setting.
5.11.21.2 Programming Limit Stops
Manual Limit Stops
NOTE: Programming preset 90
(23) disables the manual limit
stops until preset 91 (24) is set.
1. Make sure the limit stops are turned ON (refer to Section 5.11.21.1, TURNING
LIMIT STOPS ON OR OFF).
2. Program preset 90 (23) for the left manual stop and preset 91 (24) for the right
manual stop. Refer to the documentation for your control system for program-
ming presets. Program preset 90 (23) first and then program preset 91 (24). If
presets 90 (23) and 91 (24) are set for the same point, the manual limit stops
will be disabled.
Scan Limit Stops
1. Make sure the limit stops are turned ON (refer to Section 5.11.21.1, TURNING
LIMIT STOPS ON OR OFF).
2. Program preset 92 (25) for the left scan stop and preset 93 (26) for the right
scan stop. Refer to the documentation for your control system for program-
ming presets. Programming preset 92 (25) disables the scan limit stops until
preset 93 (26) is set. If presets 92 (25) and 93 (26) are set for the same point,
the scan limit stops will be disabled.
48
Pelco Manual C1456M-D (10/98)
5.11.22 Park Time Minutes
This feature causes the dome to park at preset 1 after a programmed number of
minutes of control inactivity. The time can be set from 1 minute to 720 minutes (12
hours), or it can be set to zero, which disables this feature.
NOTE: Preset 1 must be pro-
grammed for the dome to park.
To change the park time:
1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET FUNC-
TIONS) to access the main menu (refer to Section 5.11.21.1, TURNING LIMIT
STOPS ON OR OFF). The main menu will appear.
2. If the cursor (>) is not beside Other, move the joystick up or down to position the
cursor beside Other.
3. Press the Iris Open button to enter the Other submenu.
4. Move the joystick up or down to position the cursor beside Park Time Minutes.
5. Press the Iris Open button. A star will appear beside Park Time Minutes and the
cursor will move to the right beside the current park time.
6. Move the joystick up or down to change the park time.
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
5.11.23 Scan Speed
The scan speed is adjustable from 1-40 degrees per second. This occurs in three
scan modes: auto, random, and frame scan.
To change the scan speed:
1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET FUNC-
TIONS) to access the main menu (refer to Section 5.11.1, MAIN MENU AC-
CESS). The main menu will appear.
2. If the cursor (>) is not beside Other, move the joystick up or down to position the
cursor beside Other.
3. Press the Iris Open button to enter the submenu entitled Other.
4. Move the joystick up or down to position the cursor beside Scan Speed deg/s.
5. Press the Iris Open button. The cursor will move to the right beside the number
of degrees.
6. Move the joystick up or down to toggle through the number of degrees (1-40)
until you reach the number you want. (If set on a low number, the scan will
appear to barely move but is still functioning.)
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL - Press the Iris Close button if you do not want to change the setting.
Pelco Manual C1456M-D (10/98)
49
5.11.24 Pattern Length
You can set the pattern length to 1.5, 3, or 6 minutes or have two half-patterns of
.75, 1.5, or 3 minutes long.
CAUTION: If the length
is changed, all patterns
that were stored are
erased.
To set the pattern length:
1. Program preset 95 (28 if in 32-preset mode; refer to Section 5.4, PRESET
FUNCTIONS) to access the main menu (refer to Section 5.11.1, MAIN MENU
ACCESS). The main menu will appear.
2. If the cursor (>) is not beside Other, move the joystick up or down to position
the cursor beside Other.
3. Press the Iris Open button to enter the submenu entitled Other.
4. Move the joystick up or down to position the cursor beside Pattern Length.
5. Press the Iris Open button. The cursor will move to the right beside the num-
ber of minutes (1.5, 3, or 6).
6. Move the joystick up or down to toggle through the number of minutes (1.5, 3, or
6).
7. SELECT - Press the Iris Open button on your keyboard to select your choice.
CANCEL- Press the Iris Close button if you do not want to change the setting.
50
Pelco Manual C1456M-D (10/98)
6.0 TROUBLESHOOTING
NOTE:The dome drive contains no
user-serviceable parts. If there is a
problem with your dome drive, it
must be returned to Pelco as a com-
plete unit for servicing.
Symptom: Unit does not operate.
1. Make sure your controller is trying to communicate with the unit and not an-
other camera.
2. Turn off power.
3. Remove the lower dome:
In-Ceiling Models - Insert the flat blade of a screwdriver into one of the slots on
the trim ring and twist the screwdriver to pop loose the trim ring and lower dome.
Pendant Models - Remove the two screws that hold the trim ring to the back
box. Insert the flat blade of a screwdriver into the slots on the trim ring and
twist the screwdriver to free the lower dome from the back box.
4. Remove the dome drive: Push in on the green drive eject tab on the side of the
dome drive and gently rock the dome drive to release the latch. When the
green latch releases, pull the dome down.
5. Turn on power.
6. If the red power LED on the door of the interconnect circuit board in the back
box does not light, turn off power.
a. Open the door to the interconnect circuit board and check the fuse.
Refer to Figure 9 for the location of the fuse. If the fuse is bad, replace
it. To order a replacement fuse from Pelco, specify the part number
FUS1.6-5X20FAST. This is a 1.6-ampere fuse, 5 x 20 mm, fast blow.
b. If the fuse is good, turn on power and use a voltmeter to check if 24 VAC
is getting to the power connector on the interconnect circuit board. Refer
to Figure 9 for the location of the AC power connector.
c. If there is 24 VAC to the power connector, turn off power and return the
back box electronic assembly to the factory for repair. Refer to Section
6.1, BACK BOX ELECTRONIC ASSEMBLY REMOVAL.
d. If there is no voltage at the power connector, check your power supply.
7. If the red power LED is lit, turn off power.
a. Open the door to the interconnect circuit board and check that all con-
nectors are fully seated.
b. Make sure the wiring is correct between the unit and controller.
c. Close the door. Check the switch settings on the dome drive (refer to
Tables C, D, and E) and reinstall the dome drive.
d. Turn on power. If the unit still does not operate, turn off power and re-
place the dome drive with a unit that is good, if you have a spare. Check
the switch settings on the substitute dome drive before installing it. If you
do not have a spare, return the dome drive to the factory. Also return the
back box electronic assembly. Refer to Section 6.1. BACK BOX ELEC-
TRONIC ASSEMBLY REMOVAL.
e. If you substituted a dome drive, turn on power. If the unit operates, the
original dome drive is bad. Return it to the factory. If the unit still does not
operate, then the interconnect board is bad. Return the back box elec-
tronic assembly to the factory; refer to Section 6.1, BACK BOX ELEC-
TRONIC ASSEMBLY REMOVAL.
Pelco Manual C1456M-D (10/98)
51
Symptom: Fan does not operate.
1. Turn off power.
2. Remove the lower dome:
In-Ceiling Models - Insert the flat blade of a screwdriver into one of the slots
on the trim ring and twist the screwdriver to pop loose the trim ring and lower
dome.
Pendant Models - Remove the two screws that hold the trim ring to the back
box. Insert the flat blade of a screwdriver into the slots on the trim ring and
twist the screwdriver to free the lower dome from the back box.
3. Remove the dome drive: Push in on the green drive eject tab on the side of the
dome drive and gently rock the dome drive to release the latch. When the
green latch releases, pull the dome down.
4. Make sure the connector for the fan is fully seated.
5. Replace the dome drive. Turn on power. If the fan does not operate, return the
back box electronic assembly and dome drive to the factory for repair. Refer to
Section 6.1, BACK BOX ELECTRONIC ASSEMBLY REMOVAL.
Symptom: Alarms not cycling when more than one alarm is active
Reset all your alarm priorities to all LOW or all HIGH (refer to Section 5.8, ALARMS,
for an explanation of alarm high/low priorities). To reset the alarm priorities:
1. Go to Section 5.11.1, MAIN MENU ACCESS, and follow the instructions for
accessing the programming main menu.
2. Go to Section 5.11.16, ALARM PRIORITY, and follow the instructions for set-
ting the alarm priority.
Symptom: Alarms not going to preset
•
•
•
Check that the preset is defined.
Check that no higher priority alarm is activated.
Check that a pattern is not set for the affected alarm(s). If a pattern is set, the
alarm will run a pattern, not go to a preset. If a pattern (or patterns) is set, reset
the pattern(s) to NO PATTERN. To reset a pattern:
1. Go to Section 5.11.1, MAIN MENU ACCESS, and follow the instructions for
accessing the programming main menu.
2. Go to Section 5.11.17, ALARM PATTERN, and follow the instructions for set-
ting the alarm pattern.
Symptom: Alarms not starting a pattern
Ensure that the pattern selected is valid. Any time you expect a pattern to execute,
make sure the pattern is recorded correctly and is valid.
Symptom: Motion problems
When troubleshooting motion problems on a system where alarms are connected,
you can eliminate alarms as a cause of the problem by disconnecting the alarm
block in the back box.
6.1 BACK BOX ELECTRONIC ASSEMBLY REMOVAL
To remove the back box electronic assembly:
1. Turn off power.
2. Open the interconnect door and disconnect all wiring to the back box.
3. Use an 11/32 socket driver to remove the three 8-32 washers and nuts that
hold the electronic assembly to the back box. When the screws are removed,
the interconnect back box receptacle will drop down. It may be necessary to
move the open interconnect door past 90 degrees vertical toward the side of
the back box to release the door from the built-in grounding strip (and free the
interconnect back box receptacle).
4. Remove the interconnect back box receptacle with the electronic components
from the back box.
52
Pelco Manual C1456M-D (10/98)
7.0 MAINTENANCE
7.1 DOME CLEANING
Clean the acrylic dome as necessary to maintain a clear picture. Be careful not to
scratch the sufaces of the dome.
Exterior Surface - Clean the dome's exterior surface with a nonabrasive cleaning
cloth and cleaning agent that is safe for acrylic. Either liquid or spray cleaner/wax
suitable for fine furniture is acceptable.
Interior Surface (Except Chrome or Gold) - Clean the same as the exterior sur-
face.
Interior Surface (Chrome or Gold) - The inside surface of a chrome or gold dome
is easily scratched. Use the following precautions to maintain the dome's surface.
a. Always handle the dome from the outside of its circular flange.
b. Never touch the coated inside surface. The acid in your fingerprints will even-
tually etch the coating if the fingerprints are not carefully removed according
to the recommended cleaning procedure in item “e”.
c. If dust or other contaminants accumulate on the dome's interior, remove the
debris with compressed air. Compressed air cans are available from photo-
graphic equipment or electronic supply dealers.
d. If heavy residue accumulates and cannot be removed with air pressure, rinse
with water and immediately dry with air pressure so that water spots will not
remain. Avoid wiping the coated surface with direct hand pressure - it will eas-
ily abrade unless extreme care is taken. Once scratched, the dome cannot be
recoated.
e. If internal wiping is necessary, avoid hand rubbing. Instead, make a wick as
follows:
Use a very soft paper towel. Roll a section into a tightly wound tube. Tear the
tube in half, and wet the fuzzy end of the wick with a solution of isopropyl
alcohol diluted with water. Hold the dome with its opening facing downward
and wipe the interior of the dome with the wet end of the wick. Use a circular
motion, starting from the outside and spiraling into the center. Use a new wick
for each two passes over the dome.
7.2 SERVICE MANUAL
If you need to service your unit, obtain a service manual in one of the following
ways:
•
•
C1455SM.
Contact Pelco’s Literature Department and request service manual C1455SM.
Pelco Manual C1456M-D (10/98)
53
8.0 SPECIFICATIONS
MECHANICAL
Construction
Back box:
Dome drive:
Lower dome:
Cable Entry
In-Ceiling:
Pendant:
Pan Movement:
Vertical Tilt:
Manual Pan Tilt
Speeds*
Aluminum
Aluminum, ABS plastic
Acrylic
.75" (1.91 cm) conduit fitting
Through 1.5" (3.81 cm) NPT pendant mount
360° Continuous pan rotation
Unobstructed +2° to -92°
Pan:
Tilt:
Preset Speeds
Pan:
Tilt
0.5°-80°/sec manual operation, 150°/sec turbo
0.5°-40°/sec
250°/sec
100°/sec
Dimensions:
See Figure 16
* For variable-speed operation an appropriate controller is required. With fixed speed
controllers, Spectra® (Version 3.0) pan/tilt speed is 24°/sec. The CM6700 controller
with the KBD200 keyboard has programmable fixed speeds.
TOP PORTION OF BACK BOX
IS REMOVABLE FOR SURFACE
MOUNT APPLICATIONS
DOME IS SECURED
TO CEILING BY
MOUNTING BRACKET
7.25 (18.13)
6.60 (16.76)
8.52
(21.64)
5.25
(13.34)
6.75
(17.15)
10.90
27.69
5.83
(14.80)
3.25
(8.26)
5.90 (14.99)
8.25 (20.96)
5.90
(14.99)
PENDANT DOME
IN-CEILING DOME
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES.
Figure 16. SD5 Series Dimension Drawing
54
Pelco Manual C1456M-D (10/98)
ELECTRICAL
Input Voltage:
Input Power
In-ceiling:
18-30 VAC, 24 VAC nominal
25 vA
Indoor pendant: 25 vA
Outdoor
pendant:
Fuse:
90 vA
1.6 A
Relay Contacts
AUX 1
AUX 2 Output
Type:
Voltage:
Form C
Low voltage (<40 V)
Open collector transistor output
32 VDC maximum
Current:
2 A maximum
150 mA maximum
GENERAL
Environment
In-Ceiling:
Pendant:
Indoor only
Indoor/outdoor
Operating Range
In-Ceiling:
Pendant
32° to 122°F (0° to 50°C)
Without
heater:
32° to 122°F (0° to 50°C)
With Heater*: -60° to 122°F (-51.11° to 50°C)
continuous operation; minimal icing
-50° to 122°F (-45.56° to 50°C)
continuous operation; prevents icing
-40° to 122°F (-40° to 50°C)
continuous operation; de-ices .1" (2.5 mm)
within three hours after power-up
Weight
In-Ceiling
Unit
Shipping
Back Box
Dome Drive
Lower Dome
Pendant
2.6 lb (1.18 kg)
2.65 lb (1.20 kg)
.19 lb (.09 kg)
4 lb (1.81 kg)
5 lb (2.27 kg)
1 lb (.45 kg)
Back Box
2.85 lb (1.28 kg)
5 lb (2.27 kg)
Add 1.25 lbs (.57 kg) for heater and sun shield
Dome Drive
Lower Dome
2.65 lb (1.20 kg)
1.30 lb (.59 kg)
5 lb (2.27 kg)
2.20 lb (1.0 kg)
Add .25 lbs (.11 kg) for heater
* Assumes no wind chill factor; for detailed test conditions, contact Pelco.
CAMERA
COLOR
Signal Format:
PAL
Scanning System: 2:1 interlace
Image Sensor
PAL:
1/4-inch interline transfer
Total pixels: 795 (H) x 596 (V)
Effective pixels: 752 (H) x 582 (V)
460 TV lines
Resolution:
Lens
Minimum f/stop: F/1.6
Focal Length:
Zoom Ratio:
Horizontal
4 to 48 mm
12X optical zoom, 8X electronic zoom
Angle of View: 47° (at 4 mm wide zoom), 4° (at 48 mm telephoto zoom)
MTBF:
Focus:
>2 million cycles at room temperature (zoom, focus, iris)
Automatic
Sensitivity:
4 lux at f/1.6 at signal level of 300 mv (PAL), gain high
Signal Process:
Sync System:
White Balance:
Shutter Speed:
Iris Control:
Gain Control:
Video Output:
Signal to Noise:
DSP III
AC line lock, phase adjustable via remote control*
Automatic with manual override*
Automatic (electronic iris)/manual; 1/50-1/30,000 (PAL)*
Automatic with manual override*
Automatic with manual override*
PAL -.7 V ±.07 V
>46 dB
* Manual control over camera setup functions depends on the head end and is not
available on all control models.
Pelco Manual C1456M-D (10/98)
55
BLACK AND WHITE
Signal Format:
EIA/CCIR
Scanning System: 2:1 interlace
Image Sensor
EIA:
1/4-inch interline transfer
Total pixels: 537 (H) x 505 (V)
Effective pixels: 510 (H) x 492 (V)
Total pixels: 537 (H) x 597 (V)
Effective pixels: 500 (H) x 582 (V)
380 TV lines
CCIR:
Resolution:
Lens
Minimum f/stop: F/1.6
Focal Length:
Zoom Ratio:
Horizontal
4 to 48 mm
12X optical zoom, 8X electronic zoom
Angle of View: 47degree (at 4 mm wide zoom), 4degree (at 48 mm telephoto
zoom)
MTBF:
Focus:
>2 million cycles at room temperature (zoom, focus, iris)
Automatic
Sensitivity:
0.5 lux at f/1.6 at signal level of 40 IRE (EIA)/300 mv (CCIR),
gain high
Signal Process:
Sync System:
Shutter Speed:
DSP III
AC line lock, phase adjustable via remote control*
Automatic (electronic iris)/manual; 1/60 – 1/30,000 (EIA); 1/50-
1/30,000 (CCIR)*
Iris Control:
Automatic with manual override*
Automatic with manual override*
EIA - .714 V ±.07 V (100 IRE ±10 IRE); CCIR -.7 V ±.07 V
>46 dB
Gain Control:
Video Output:
Signal to Noise:
* Manual control over camera setup functions is dependent on the head end and is
not available on all control models.
(Design and product specifications subject to change without notice.)
56
Pelco Manual C1456M-D (10/98)
NOTES
Pelco Manual C1456M-D (10/98)
57
9.0 WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or
workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
•
•
•
Five years on FT/FR8000 Series fiber optic products.
Three years on Genex® Series products (multiplexers, server, and keyboard).
Three years on Camclosure® and fixed camera models, except the CC3701H-2, CC3701H-2X,
CC3751H-2,CC3651H-2X,MC3651H-2,andMC3651H-2Xcameramodels,whichhaveafive-
year warranty.
•
•
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed
dome products.
•
Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, including when used in
continuous motion applications.
•
•
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).
Eighteen months on DX Series digital video recorders, NVR300 Series network video
recorders, and Endura™ Series distributed network-based video products.
•
•
One year (except video heads) on video cassette recorders (VCRs). Video heads will be
covered for a period of six months.
Sixmonthsonallpanandtilts,scannersorpresetlensesusedincontinuousmotionapplications
(that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment.
AllgoodsrequiringwarrantyrepairshallbesentfreightprepaidtoPelco,Clovis,California.Repairs
made necessary by reason of misuse, alteration, normal wear, or accident are not covered under
this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the
specific use or application made of the Products. Pelco’s liability for any claim, whether based on
breach of contract, negligence, infringement of any rights of any party or product liability, relating
totheProductsshallnotexceedthepricepaidbytheDealertoPelcoforsuchProducts. Innoevent
will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss
of profit and claims of third parties) however caused, whether by the negligence of Pelco or
otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have
additional rights, which are subject to variation from state to state.
Ifawarrantyrepairisrequired, theDealermustcontactPelcoat(800) 289-9100or(559)292-1981
to obtain a Repair Authorization number (RA), and provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall under the warranty
conditions stated above, please include a written explanation with the product when returned.
Methodofreturnshipmentshallbethesameorequaltothemethodbywhichtheitemwasreceived
by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800)
289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit,
and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number
and freight should be prepaid. Ship to the appropriate address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed
to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco, the Pelco logo, Camclosure, Esprit,
Genex, Legacy, and Spectra are registered
trademarks of Pelco.
Pelco c/o Expeditors
473 Eccles Avenue
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
Endura and ExSite are trademarks of Pelco.
© Copyright 1998, Pelco. All rights reserved.
58
Pelco Manual C1456M-D (10/98)
|