Pelco Model Vehicle ccc4000pckit User Manual

®
CCC4000PCKIT  
Camera Control  
Software  
Installation/  
Operation Manual  
C1931M (5/99)  
Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 USA • www.pelco.com  
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150  
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120  
 
DESCRIPTION  
Version 1.2 of the CCC4000 Camera Control software lets you program controls in all mod-  
els of the CCC4000 Series color cameras for the following:  
White balance  
Vertical phase (V-phase)  
Edge enhancement  
Illumination control  
Hue  
These controls determine the way the camera operates by creating unique camera perfor-  
mance for special applications.  
To set the camera’s controls, the camera is connected to a PC and programmed through a  
Microsoft® Windows® interface.You can program and store three sets of settings in the  
camera’s memory. In addition, you can recall and use the default factory setting at any time.  
MINIMUM HARDWARE AND SOFTWARE REQUIREMENTS  
The following are minimum hardware and software requirements to run Version 1.2 of the  
CCC4000 Camera Control software:  
IBM-compatible personal computer with available serial interface port  
MicrosoftWindowsoperating system, Version 3.1 or later  
INSTALLING THE CCC4000 CAMERA CONTROL SOFTWARE  
To install the camera control software:  
1. Insert the disk in drive A.  
2. Do one of the following:  
If you are installing the CCC4000 Camera Control software under Windows 3.1, select  
File Manager, and then select drive A.  
or  
If you are installing the CCC4000 Camera Control software under Windows 95 or a  
later version, open Windows Explorer, and then select drive A.  
3. Double-click install.bat.  
The following screen appears:  
INSTALL - WHAT  
Auto  
The camera control software is automatically installed in the VCM directory on drive  
C. If you do not want to install the camera control software in this directory, select a dif-  
ferent directory. However, Pelco recommends that you install the software in a sepa-  
rate, unique directory.  
Pelco Manual C1931M (5/99)  
3
 
4. Do one of the following:  
Press ENTER to install the software in the C:\VCM directory.  
or  
Type the path and directory name where you want to install the software, and press  
ENTER.  
The following messages appear:  
Finished - INSTALL  
Auto  
x
5. Press ENTER, and then click  
to close the installation window.  
CONNECTING THE CAMERA TO THE COMPUTER  
To program the camera, the camera must be connected to the computer where the software  
is installed. Establish a connection between the camera and the computer using the sup-  
plied cable.  
1. Important. . . Before you connect the camera to the computer, turn off the com-  
puter.  
2. Connect the DB-9 end of the cable to an RS-232 communication port on the computer.  
If the computer has multiple communication ports, make a note of the port to which  
you connected the cable; you may need to identify this port later.  
3. Plug the other end of the cable into the camera.  
4. Connect the camera to power.  
5. Restart the computer.  
STARTING AND EXITING CCC4000 CAMERA CONTROL  
SOFTWARE  
To start the CCC4000 Camera Control software:  
1. In File Manager (Windows 3.1) or Windows Explorer (Windows 95 and later versions),  
access the VCM directory and double-click Vcm_cc.exe.  
Name  
Ctl3d.dll  
Readme.txt  
Vcm cc.exe  
Vcm cc.hlp  
4
Pelco Manual C1931M (5/99)  
 
The Pelco CCC4000 Camera Control window appears.  
Pelco CCC4000 Camera Control  
File Info Help  
White Balance  
V-Phase  
122  
Hue  
33  
-5  
2
mSec  
%
%
degrees  
Line Lock  
Full Remote  
Full Auto  
Edge Enhancement  
On / Off  
Fixed Indoor  
Illumination Control  
Fixed Outdoor  
Fixed FL / TL  
Speed  
Red Blue  
Program 1  
Shutter  
Default Save  
Comm port 2  
Program 2  
Program 3  
AGC  
Firmware version: 1.1  
NTSC  
Camera ready  
2. Verify that the camera status is Camera ready.  
You cannot program the camera until the status is Camera ready. If the status is not  
Camera ready, check the following:  
The cable is connected to the camera.  
The cable is connected to the computer.  
The camera has power.  
The correct communication port is selected.  
To exit from the CCC4000 Camera Control software:  
x
1. Click  
. If you have not saved the changes you made, a message appears asking  
you to save the changes.  
2. Choose Yes to save the changes, or No to cancel (delete) the changes you made.  
ABOUT THE CAMERA CONTROL SOFTWARE  
You change the camera controls through the Pelco CCC4000 Camera Control screen.You  
have the option to save three sets of camera controls, and you can recall the factory setting  
at any time.  
CAMERA STATUS  
The status at the bottom of the control window shows information about the camera and in-  
dicates whether the camera can be programmed. The camera must be in Camera ready  
status before it can be programmed.  
Firmware version: 1.1  
NTSC  
Camera ready  
VERSION NUMBER  
OF THE FIRMWARE  
TV STANDARD  
OF THE CAMERA,  
NTSC OR PAL  
STATUS OF THE CAMERA  
A Faulty camera status indicates that there is a problem with the camera. A No connec-  
tion to camera status indicates that the camera is not properly connected to the computer.  
CAMERA CONTROL SETTINGS  
The camera automatically starts and uses the settings from the program that was selected  
last.You can change the following camera controls:  
White balance  
V-phase  
Edge enhancement  
Illumination control  
Hue  
Pelco Manual C1931M (5/99)  
5
 
WHITE BALANCE MODES  
When the camera is adjusted properly, the white parts of a scene should be white, not an-  
other color. Automatic (Full Auto) and fixed (Fixed) modes set the camera’s white bal-  
ance automatically for you, while remote (Full Remote) mode lets you specify the  
camera’s control settings.  
Full Remote – When you choose Full Remote, you can adjust the white balance by  
changing the percent of red or blue in the scene.  
Full Auto – When you choose Full Auto, no further adjustments are required; however,  
you may want to change the speed of the white balance. In Full Auto mode, the white bal-  
ance continuously and automatically corrects the color temperature within a range of 2500  
to 6500 Kelvin.  
When you select Full Auto, the Speed control is active. The speed changes the time interval  
between two successive white balance measurements in the camera. The minimum time in-  
terval for PAL cameras is 20 ms, and the maximum is 2.3 seconds. For NTSC cameras, the  
minimum time interval is 16.67 ms, and the maximum is 2 seconds.  
When the lighting of a scene (related to color temperature) is changing very slowly, a low  
speed white balance adjustment gives you the best performance. However, when the color  
temperature changes fast or often, a high speed white balance adjustment gives you the  
best performance.  
Fixed – Fixed modes have pre-set balance settings. The camera has the following balance  
settings:  
fixed indoor (color temperature of 3200 Kelvin)  
fixed outdoor (color temperature of 5600 Kelvin)  
fixed FL/TL (fluorescent light of approximately 4500 Kelvin)  
VERTICAL PHASE (V-PHASE)  
When two or more cameras share the same monitor or VCR, switching from one camera to  
another may cause the picture to roll on the monitor and cause a temporary recording mal-  
function on the VCR. Rolling occurs when cameras are not synchronized. To prevent rolling,  
the Line-Lock control synchronizes the power supply so that it is in phase with the camera.  
Phase variations in the power supply can cause phase variations between cameras. To cor-  
rect the phase variations, you can change the camera’s V-phase control in 1-degree incre-  
ments to a maximum of plus or minus (+/-) 313 degrees.  
EDGE ENHANCEMENT  
Edge enhancement gives you a sharper picture. Edge enhancement, however, also in-  
creases the noise in the picture. Depending on how you use the camera, you can turn the  
Edge Enhancement control off to reduce the noise in the picture.  
ILLUMINATION CONTROL  
The camera uses the AGC (Automatic Gain Control), Iris, and Shutter controls for illumina-  
tion adjustment. The AGC control is always active. However, depending on the type of lens  
mounted on the camera, either the Iris or the Shutter control is active; both are not active at  
the same time. Fixed-iris and manual-iris lenses activate the Shutter control, and passive  
auto-iris lenses activate the Iris control.  
AGC keeps the output signal of the camera constant for an illumination range. When a  
scene is dark and contains only a few highlights, realistic color is reproduced as the AGC  
automatically amplifies to the maximum level.  
NOTE: If you install an  
electronic lens on the  
CCC40001-2 camera, the  
Shutter control is not valid  
because the electronic shut-  
ter feature is disabled on the  
CCC40001-2 camera.  
Iris and Shutter are both Iris controls.You use the Iris control for mechanical-lens iris con-  
trol, and the Shutter control for an electronic-lens iris. In scenes where background illumina-  
tion forms a highlight compared to the main subject, the subject appears very dark on the  
monitor. (This occurs, for example, when a person stands in front of a window.) You must  
compensate for the lighting by realigning the controls so that the main subject is clear.  
6
Pelco Manual C1931M (5/99)  
 
HUE  
Hue ensures that a monitor accurately displays colors by correcting the phase of the color  
signal. Hue applies only to NTSC cameras.  
CHANGING THE CAMERA’S CONTROLS  
To change the camera’s controls:  
1. In the Program section, select Program 1, Program 2, or Program 3 depending  
on where you want to save the new settings.  
2. If the correct communications port is not selected, select the port where you installed  
the DB-9 cable.  
3. Select one of the following White Balance controls:  
In normal situations, select Full Auto for all color temperature changes between  
2500 and 6500 Kelvin. When the scene contains 5 percent or less white, Full  
Auto does not perform at an optimum level.  
For incandescent indoor lighting, select Fixed Indoor (fixed-color temperature  
of 3200 Kelvin).  
For clear-daylight, outdoor lighting, select Fixed Outdoor (fixed-color tempera-  
ture of 5600 Kelvin).  
For fluorescent lighting, select Fixed FL/TL (fixed-color temperature of 4500  
Kelvin).  
For special light conditions, select Full Remote (corrects every color tempera-  
ture between 2500 and 6500 Kelvin).  
4. Do one of the following:  
If you selected Full Auto, adjust the speed.  
or  
If you selected Full Remote, adjust the percent of red or blue in the scene as neces-  
sary using the appropriate scroll bar.  
5. Set the V-phase using the scroll bar. If only one camera is connected to a monitor and  
VCR, turn off the Line-Lock control. Turning off this control improves the picture quality.  
6. Set the Edge Enhancement by selecting the On/Off control. If a check mark appears,  
the edge enhancement control is turned on.  
7. Using the appropriate scroll bar, do one of the following:  
If you are setting up an NTSC camera, set the Illumination Control by adjusting the  
Shutter and AGC as necessary.  
or  
If you are setting up a PAL camera, set the Illumination Control by adjusting the Iris  
and AGC as necessary.  
8. If you are setting up an NTSC camera, set the Hue using the scroll bar.  
Pelco Manual C1931M (5/99)  
7
 
SAVING THE SETTINGS  
To save the settings in the camera after changing the camera controls:  
Save  
1. Select  
2. Click  
.
x
to close the CCC4000 Camera Control program.  
GETTING HELP  
Instructions to use the Pelco CCC4000 Camera Control software can be found in the online  
help file. To access the online help file from the menu bar, choose Help. Then choose  
Help index. The Pelco CCC4000 Camera Control Software help file appears.  
From the help file’s Table of Contents you can access topics related to getting started, un-  
derstanding the camera control settings, and adjusting the camera’s settings.  
PRODUCT WARRANTY AND RETURN INFORMATION  
WARRANTY  
Pelco will repair or replace, without charge, any merchandise proved defective in material or  
workmanship for a period of one year after the date of shipment.  
If  
a
warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or  
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following  
information:  
1. Model and serial number  
Exceptions to this warranty are as noted below:  
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number  
3. Details of the defect or problem  
Five years on FT/FR8000 Series fiber optic products.  
Three years on Genex® Series products (multiplexers, server, and keyboard).  
If there is a dispute regarding the warranty of a product which does not fall under the  
warranty conditions stated above, please include a written explanation with the product  
when returned.  
Three years on Camclosure® and fixed camera models, except the CC3701H-2,  
CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models,  
which have a five-year warranty.  
Method of return shipment shall be the same or equal to the method by which the item was  
received by Pelco.  
Two years on standard motorized or fixed focal length lenses.  
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series  
fixed dome products.  
RETURNS  
In order to expedite parts returned to the factory for repair or credit, please call the factory at  
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned  
for credit, and RA number if returned for repair).  
Two years on Spectra®, Esprit®, ExSite, and PS20 scanners, including when used in  
continuous motion applications.  
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).  
All merchandise returned for credit may be subject to a 20% restocking and refurbishing  
charge.  
Eighteen months on DX Series digital video recorders, NVR300 Series network video  
recorders, and EnduraSeries distributed network-based video products.  
Goods returned for repair or credit should be clearly identified with the assigned CA or RA  
number and freight should be prepaid. Ship to the appropriate address below.  
One year (except video heads) on video cassette recorders (VCRs). Video heads will be  
covered for a period of six months.  
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:  
Six months on all pan and tilts, scanners or preset lenses used in continuous motion  
applications (that is, preset scan, tour and auto scan modes).  
Service Department  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699  
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco  
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,  
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident  
are not covered under this warranty.  
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are  
instructed to return goods to the USA, you may do one of the following:  
If the goods are to be sent by a COURIER SERVICE, send the goods to:  
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from  
the specific use or application made of the Products. Pelcos liability for any claim, whether  
based on breach of contract, negligence, infringement of any rights of any party or product  
liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for  
such Products. In no event will Pelco be liable for any special, incidental or consequential  
damages (including loss of use, loss of profit and claims of third parties) however caused,  
whether by the negligence of Pelco or otherwise.  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699 USA  
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:  
Pelco c/o Expeditors  
473 Eccles Avenue  
The above warranty provides the Dealer with specific legal rights. The Dealer may also have  
additional rights, which are subject to variation from state to state.  
South San Francisco, CA 94080 USA  
Phone: 650-737-1700  
Fax: 650-737-0933  
REVISION HISTORY  
Manual # Date  
C1931M 5/99  
Comments  
Original version.  
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco.  
Endura and ExSite are trademarks of Pelco.  
©Copyright 1999, Pelco.  
All rights reserved.  
8
Pelco Manual C1931M (5/99)  
 

PGS Gas Grill S27 User Manual
Philips CD Player 128MB User Manual
Philips Headphones SHE9621 User Manual
Philips Music Mixer SA615 User Manual
Philips Speaker AD7000W 12 User Manual
Poulan Chainsaw PP3516AVX User Manual
Poulan Lawn Mower Accessory PR625Y22SHP User Manual
Poulan Tiller FT825 User Manual
Premier Mounts Projector Accessories MAG 1321 User Manual
PYLE Audio CD Player PLCD26 User Manual