I N S T A L L A T I O N
®
110 Series Camclosure
Integrated Camera
System
Surface Mount
C2403M-E (2/08)
Contents
Important Safety Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Regulatory Notices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Mounting Directly to Surface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Wiring Through Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Wiring Through Side Conduit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Mounting to a 4S Electrical Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Mounting to a Plaster Ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Install Camera. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Install Dome and Trim Ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Adjustments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Vertical Phase (24 VAC Operation Only). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Focus Adjustment for Fixed Focal Length Lens with Auto Iris. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Switch Settings for Fixed Focal Length Lens Without Auto Iris . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
C2403M-E (2/08)
3
Important Safety Instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
6. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus
(including amplifiers) that produce heat.
7. Only use attachments/accessories specified by the manufacturer.
8. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the
apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid
injury from tip-over.
9. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been
damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or
objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not
operate normally, or has been dropped.
10. Installation should be done only by qualified personnel and conform to all local codes.
11. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is
designed for indoor use only and it must not be installed where exposed to rain and moisture.
12. Use only installation methods and materials capable of supporting four times the maximum
specified load.
13. Use stainless steel hardware to fasten the mount to outdoor surfaces.
14. To prevent damage from water leakage when installing a mount outdoors on a roof or wall, apply
sealant around the bolt holes between the mount and mounting surface.
15. CAUTION: These servicing instructions are for use by qualified service personnel only.
To reduce the risk of electric shock do not perform any servicing other that contained in the
operating instructions unless you are qualified to do so.
16. Only use replacement parts recommended by Pelco.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage
CAUTION:
constituting a risk of electric shock is present
within this unit.
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
This symbol indicates that there are important
operating and maintenance instructions in the
literature accompanying this unit.
Please thoroughly familiarize yourself with the information in this manual prior to installation and
operation.
4
C2403M-E (2/08)
Regulatory Notices
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However there is no guarantee that the interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
•
Consult the dealer or an experienced radio/TV technician for help.
You may also find helpful the following booklet, prepared by the FCC: “How to Identify and Resolve Radio-
TV Interference Problems.” This booklet is available from the U.S. Government Printing Office, Washington
D.C. 20402.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment
can void your authority to operate this equipment under Federal Communications Commission’s rules.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
C2403M-E (2/08)
5
Description
The ICS110 Series Camclosure® integrated camera system combines an environmental cover, back box,
camera, lens, and lower dome into a small, high-security system that is quick and easy to install. The
system is perfect for a variety of indoor and outdoor applications, and its versatile design allows for
multiple mounting options.
The ICS110 Series Camclosure can be installed directly to a ceiling, wall, 4S electrical box (using the
optional ICS110-AP adapter plate), or a standard plaster ring. The system has three conduit openings: two
in the base, and a threaded 0.75-inch (1.91 cm) opening in the side.
6
C2403M-E (2/08)
Installation
MOUNTING DIRECTLY TO SURFACE
WIRING THROUGH BASE
Follow the proceeding steps when feeding wire/cables through the base of the cover and back box:
1. Using the cover as a template, mark one of
the large hole positions onto the mounting
surface.
2. Cut out the hole in the mounting surface for
COVER
power and video wiring.
3. Pull video and power wires through the
hole in the cover.
4. Attach the cover to the mounting surface
(hardware not supplied). Use stainless steel
hardware when installing the system
BACK BOX
outdoors.
5. Connect the video cable.
6. Connect the power wires.
•
For 12 VDC, connect the 24 VAC/12
VDC (red) and GND (black) wires to
input power. The blue wire is not
used.
•
For 24 VAC, connect the 24 VAC/12 VDC (red) and 24 VAC (blue) wires to input power.
The black wire is not used.
7. Install the back box inside the cover. Rotate and position the back box so that the conduit plug on the
side of the box is located on the opposite side (180 degrees) from the notch on the side of the cover.
Use the supplied 8-32 x 0.375-inch screws and washers to secure the back box to the cover.
NOTE: For vandal-resistant installations, the conduit plug located on the side of the back box should be
hidden if it is not used. To hide the conduit plug rotate the back box so that the plug is located on the
opposite side (180 degrees) from the notch on the side of cover.
C2403M-E (2/08)
7
WIRING THROUGH SIDE CONDUIT
Follow the proceeding steps when feeding wire/cables through the side conduit opening of the unit:
1. Attach the cover to the mounting surface (hardware not supplied). Use stainless steel hardware
when installing the system outdoors.
2. Remove the conduit plug from the side of the back box.
3. Use a blunt tool to pull the wires and plug, located on the base of the back box, into the back box.
Insert the black plug (supplied) into the hole in the base of the back box.
4. Install the back box inside the cover. Rotate and position the back box so that the conduit hole on the
side of the back box is aligned with the side notch of the cover. Use the supplied 8-32 x 0.375-inch
screws and washers to secure the back box to the cover.
5. Install a 0.75-inch (1.91 cm) conduit fitting in the conduit hole of the back box.
6. Connect the video cable.
7. Connect the power wires.
•
For 12 VDC, connect the 24 VAC/12 VDC (red) and GND (black) wires to input power.
The blue wire is not used.
•
For 24 VAC, connect the 24 VAC/12 VDC (red) and 24 VAC (blue) wires to input power.
The black wire is not used.
MOUNTING TO A 4S ELECTRICAL BOX
1. Attach the ICS110-AP adapter plate (not supplied) to a 4S box with the two 8-32 x 0.75-inch flat
head screws supplied with the adapter plate.
2. Pull the video and power wires into the cover, and then attach the cover to the adapter plate with
the three supplied 8-32 x 0.375-inch pan head screws.
3. Connect the video cable.
4. Connect the power wires.
•
For 12 VDC, connect the 24 VAC/12 VDC (red) and GND (black) wires to input power.
The blue wire is not used.
•
For 24 VAC, connect the 24 VAC/12 VDC (red) and 24 VAC (blue) wires to input power.
The black wire is not used.
5. Install the back box inside the cover. For vandal-resistant installations, rotate and position the back
box so that the conduit plug on the side of the box is located on the opposite side (180 degrees) from
the notch on the side of the cover. Use the supplied 8-32 x 0.375-inch screws and washers to secure
the back box to the cover.
MOUNTING TO A PLASTER RING
1. Pull video and power wires into the cover, and then attach the cover to a 404 plaster ring. Use the
two supplied 6-32 x 0.75-inch pan head screws to attach the cover to a 404 plaster ring.
2. Connect the video cable.
3. Connect the power wires.
•
For 12 VDC, connect the 24 VAC/12 VDC (red) and GND (black) wires to input power.
The blue wire is not used.
•
For 24 VAC, connect the 24 VAC/12 VDC (red) and 24 VAC (blue) wires to input power.
The black wire is not used.
4. Install the back box inside the cover. For vandal-resistant installations, rotate and position the back
box so that the conduit plug on the side of the box is located on the opposite side (180 degrees) from
the notch on the side of the cover. Use the supplied 8-32 x 0.375-inch screws and washers to secure
the back box to the cover.
8
C2403M-E (2/08)
Install Camera
WARNING: Heater elements could be hot! When camera power is on, use caution when
adjusting the camera. This applies to all models.
1. Some indoor installations do not require a heater. If the
installation does not require a heater, remove the heater
board from the camera assembly. To remove the heater,
press on an end of the board.
HEATER
BOARD
2. 12 VDC operation only: The camera is set for 24 VAC
operation at the factory. For 12 VDC operation remove
the jumper from the 24 VAC position and install it in the
12 VDC position.
VIDEO
CONNECTOR
HEATER
CONNECTOR
12 VDC JUMPER
24 VAC JUMPER
3. If the heater is installed, plug the heater connector from
the camera into the mating connector inside the base.
Plug the video connector from the camera into the
mating connector inside the base.
Turn on power to the camera and monitor.
VIDEO
CONNECTOR
4. Always make sure the tab on the camera bracket is
pointing out of the enclosure (away from the ceiling or
wall). Gently squeeze the bracket, place it against the
groove inside the back box, and then gently release.
HEATER
CONNECTOR
Proper camera orientation:
CAMERA BRACKET
TAB ALWAYS POINTS
TOP OF
OUT OF THE
CAMERA
ENCLOSURE
CAMERA BRACKET
TAB ALWAYS POINTS
OUT OF THE
ENCLOSURE
Wall Mounting: The camera braket
tab points out of the enclosure, and
the top of the camera points up
towards the tab.
Ceiling Mounting: The camera bracket tab
points out of the enclosure, and the top of
the camera is pointed in the opposite
direction.
C2403M-E (2/08)
9
Install Dome and Trim Ring
Domes with Liners (only):
1. Align the screw holes in the trim ring with
those in the Camclosure base.
ADJUSTMENT
GROOVE
2. Position the viewing window over the lens of
the camera.
DOME LINER
a.
Loosen the three Phillip screws located
in the dome.
LOOSEN SCREWS
b.
Insert the blade of a standard
screwdriver in one of the adjustment
grooves. Move the dome into position.
c.
Tighten the three Phillip screws to lock
the liner in place.
3. Tighten the tamper-resistant screws with the supplied 1/8-inch hollow screwdriver bit.
10
C2403M-E (2/08)
Adjustments
The camera is set up at the factory and normally requires no adjustments. Sometimes, however,
adjustments may be necessary.
1. Remove the dome and trim ring using the supplied 1/8-inch hollow screwdriver bit.
2. Adjust the vertical phase, focus, or switch settings (refer to the following procedures).
3. Replace the dome and trim ring.
VERTICAL PHASE (24 VAC OPERATION ONLY)
Adjustment is required if there is vertical roll when switching between two cameras.
1. Reverse the 24 VAC connections on one camera. If both cameras are connected to the same
transformer, this should solve the problem.
2. If reversing the connections does not solve the problem, or if cameras are connected to different
transformers, turn the adjustment screw on one camera (while switching as rapidly as possible
between the two camera views) until the switching is clean and there is no vertical roll. If more than
two cameras are out of synchronization with each other, choose one camera and synchronize all
others to it.
VERTICAL
PHASE
ADJUSTMENT
C2403M-E (2/08)
11
FOCUS ADJUSTMENT FOR FIXED FOCAL LENGTH LENS WITH
AUTO IRIS
WARNING: Heater elements could be hot! When camera power is on, use caution when
adjusting the camera.
To adjust the focus, it may be necessary to remove the heater board in order to loosen the locking screw on
the bottom of the lens.
To remove the heater board:
1. Disconnect the 4-pin heater wiring.
HEATER
2. Wait for the heater elements to cool if they are hot.
3. Press on an end of the board.
BOARD
To adjust the focus:
FOCUS
ADJUSTMENT SCREW
1. Loosen the locking screw on the bottom of the lens.
2. Move the screw in the slot to bring the picture into focus.
3. Retighten the locking screw.
4. Replace the heater board if it was removed.
5. Reconnect the 4-pin heater wiring.
ADJUSTMENT SLOT
BOTTOM VIEW OF CAMERA
WITH HEATER BOARD REMOVED
SWITCH SETTINGS FOR FIXED FOCAL LENGTH LENS WITHOUT
AUTO IRIS
Refer to the switch position drawing. The switch is located next to the lens. Automatic backlight
compensation (factory setting) is used under varying lighting conditions (such as outdoors) or fixed lighting
conditions, where there are no bright spots that darken other picture details. Manual backlight
compensation is used in fixed lighting conditions to optimize the picture detail when there are bright
spots.
•
•
•
ALC/ELC switch:
Always ELC
Not used
FACTORY SETTINGS
Y/DC switch:
Auto backlight compensation:
BLC switch OFF
ABL switch ON
•
Manual backlight compensation:
BLC switch ON
ABL switch OFF
= SWITCH POSITION
12
C2403M-E (2/08)
Specifications
General
Operating Temperature
-50° to 122°F (-46° to 50°C)
De-ices to 25°F (-4°C)
Cable Entry
3/4-inch (1.91 cm) conduit fitting and 3/4-inch (1.91 cm) opening for
NPT threaded pipe
Pan/Tilt Adjustment
Construction
Finish
Manual; 360° pan, 180° tilt
Aluminum with steel camera mounting bracket and polycarbonate dome
Gray polyester powder coat
Environment
Unit Weight
Low temperature, indoor/outdoor
2.2 lb (1.0 kg)
Electrical
Input Voltage
Power Consumption
Video Connector
12 VDC or 24 VAC, 10%
13 W or less
BNC
3X Ø 0.343
THRU
5.50
(13.97)
1.76
(4.47)
2.36
(6.00)
3.593
(9.136)
4.01
(10.19)
1.797
(5.026)
3.79
(9.63)
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS;
ALL OTHERS ARE INCHES.
(Design and product specifications subject to change without notice.)
C2403M-E (2/08)
13
The materials used in the manufacture of this document and its components are compliant to the
requirements of Directive 2002/95/EC.
This equipment contains electrical or electronic components that must be recycled properly to
comply with Directive 2002/96/EC of the European Union regarding the disposal of waste
electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling
this equipment.
14
C2403M-E (2/08)
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of
shipment.
Exceptions to this warranty are as noted below:
•
•
•
•
Five years on fiber optic products and TW3000 Series unshielded twisted pair (UTP) transmission products.
Three years on Spectra® IV products.
Three years on Genex® Series products (multiplexers, server, and keyboard).
Three years on DX Series digital video recorders, DVR5100 Series digital video recorders, DigitalSENTRY® Series hardware products, DVX Series
digital video recorders, NVR300 Series network video recorders, and Endura® Series distributed network-based video products.
Three years on Camclosure® and Pelco-branded fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2,
and MC3651H-2X camera models, which have a five-year warranty.
•
•
•
•
•
•
•
Three years on PMCL200/300/400 Series LCD monitors.
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products.
Two years on Spectra III™, Spectra Mini, Esprit®, ExSite®, and PS20 scanners, including when used in continuous motion applications.
Two years on Esprit and WW5700 Series window wiper (excluding wiper blades).
Two years (except lamp and color wheel) on Digital Light Processing (DLP®) displays. The lamp and color wheel will be covered for a period of
90 days. The air filter is not covered under warranty.
Two years on Intelli-M® eIDC controllers.
One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.
Six months on all pan and tilts, scanners, or preset lenses used in continuous motion applications (preset scan, tour, and auto scan modes).
•
•
•
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent
freight prepaid to a Pelco designated location. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under
this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s
liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the
Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental, or
consequential damages (including loss of use, loss of profit, and claims of third parties) however caused, whether by the negligence of Pelco or
otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state
to state.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and
provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, sales order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product that does not fall under the warranty conditions stated above, please include a written
explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
RETURNS
To expedite parts returned for repair or credit, please call Pelco at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if
returned for credit, and RA number if returned for repair) and designated return location.
All merchandise returned for credit may be subject to a 20 percent restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid.
1-8-08
REVISION HISTORY
Manual #
C2403M
Date Comments
2/05 Original version.
C2403M-A
C2403M-B
4/05 Varifocal camera case redesigned. Replaced 8-32 x 0.5-inch screws with 8-32 x 0.375-inch screws per ECO 05-10876.
5/05 Added information for setting the jumper when using 12 VDC, and revised dimension drawing to show mounting
hole pattern.
C2403M-C
C2403M-D
C2403M-E
10/05
Revise switch setting-descriptions for varifocal lens. Added WEEE statement.
1/06 Updated factory switch settings for varifocal lens. Updated wiring information.
2/08 Revised manual for fixed focus color cameras.
Pelco, the Pelco logo, Camclosure, DigitalSENTRY, Endura, Esprit, ExSite, Genex, Intelli-M, Legacy, and Spectra are registered trademarks of Pelco, Inc.
Spectra III is a trademark of Pelco, Inc.
© Copyright 2008, Pelco, Inc. All rights reserved.
DLP is a registered trademark of Texas Instruments, Inc.
Worldwide Headquarters
3500 Pelco Way
Clovis, California 93612 USA
USA & Canada
Tel: 800/289-9100
Fax: 800/289-9150
International
Tel: 1-559/292-1981
Fax: 1-559/348-1120
ISO9001
Australia Finland France Germany Italy Macau The Netherlands Russia Singapore
|
|
|
|
|
|
|
|