Pelco Video Gaming Accessories WCS1 4 User Manual

INSTALLATION/OPERATION  
WCS1-4  
Environmental  
Power Supply  
®
C561M-E (8/05)  
 
DESCRIPTION  
The WCS1-4 is a mutliple power supply designed for indoor or outdoor applications and is ideal for  
use with cameras, domes, and integrated positioning systems such as Spectra® and Esprit®. The  
WCS1-4 is capable of powering up to four units and can handle pan/tilt, heater, blower, and camera  
operation.  
The WCS1-4 power supply has one fused output and is capable of handling up to 4 amps (100 VA)  
of total load. The unit features selectable 100/120/240 VAC input power, selectable 24/26/28 VAC  
output power, and a stainless steel link-lock latch that can be secured with padlock (padlock not  
provided).  
C561M-E (8/05)  
 
3
INSTALLATION  
MOUNTING INSTRUCTIONS  
To mount the power supply directly to a wallboard, wall, or concrete refer to Figures 1 through 3  
and do the following:  
1. Remove the retaining screw from the door latch of the WCS1-4 power supply.  
2. Open the door of the WCS1-4 power supply, and then remove the plug(s) from the required  
conduit hole(s) located on the bottom of the unit. Install 3/4-inch (1.91 cm) conduit fitting(s) (not  
supplied). Close the lid to the power supply.  
3. Determine the mounting location for the WCS1-4.  
4. Use the WCS1-4 power supply as a template and mark the four fastener positions on the  
mounting surface.  
5. Prepare the holes for installation.  
6. Attach the WCS1-4 power supply securely to the mounting surface with four fasteners of  
appropriate length. Fasteners between 1/4-inch and 5/16-inch diameter (not supplied) can be  
used.  
MOUNTING HARDWARE WITH  
ANCHOR OR TOGGLE BOLT  
(NOT SUPPLIED)  
MOUNTING  
WOOD SCREW  
(NOT SUPPLIED)  
HARDWARE  
(NOT SUPPLIED)  
DOOR  
LATCH  
DOOR  
LATCH  
DOOR  
LATCH  
RETAINING  
SCREW  
RETAINING  
SCREW  
RETAINING  
SCREW  
CONCRETE  
WALL  
WALLBOARD  
WALL  
Figure 1.  
Mounting to  
Wallboard  
Figure 2.  
Mounting to  
Figure 3.  
Mounting to Concrete  
Wall  
WARNING: Under light load conditions and high input power voltage, output voltage  
from the WCS1-4 power supply may reach 32 VAC. Pelco recommends that all  
equipment connected to the WCS1-4 power supply be rated to handle 32 VAC.  
Pelcos Spectra® domes and Esprit® integrated positioning systems meet this require-  
ment.  
Pelco cannot be liable for any damages resulting from incorrect wiring of the WCS1-4  
power supply.  
4
C561M-E (8/05)  
 
FUSE INSTALLATION  
The WCS1-4 power supply is shipped from the factory with a 1.6-amp fuse installed for 100/120 VAC  
input power. To use input power of 240 VAC, change the 1.6-amp fuse to a 500-milliamp fuse (supplied).  
To change the fuse remove the lid to the fuse holder (refer to figure 4) located inside the power  
supply and then install the new fuse. Store extra fuses (supplied) in the spare fuse holders.  
INPUT POWER WIRING  
WARNING: The WCS1-4 does not have an on/off switch. Turn off power at the circuit  
breaker before wiring the power supply.  
To install the input power wires to the WCS1-4 power supply, refer to Figure 4 and do the  
following:  
1. Determine the size of the input wire needed.  
2. Bring the wiring into the WCS1-4 through the conduit fitting.  
3. Attach the neutral input power wire to the 100V, 120V, or 240V NEUTRAL connection on the  
Primary Line Input connector strip. Attach the hot wire to the LINE connection on the same  
strip.  
4. Attach the input ground wire to the No. 6 ground stud, located between the conduit holes, and  
tighten the wire with the nut and washer (supplied).  
C561M-E (8/05)  
 
5
OUTPUT WIRING  
To install the output wiring to the camera, dome, or positioning system, refer to Figure 4 and do the  
following:  
1. Refer to Table A and determine the output connection needed for your camera, dome, or  
positioning system. Refer to Figure 4, for the proper connector strip connections.  
2. Attach one output wire to either the Tap A (24 VAC), Tap B (26 VAC), or Tap C (28 VAC)  
connections on the Secondary Output Tap’s connector strip and attach the second wire to the  
COM connection on the same strip. Be sure that you have the proper wiring size and distances  
installed if you plan to change connections later.  
3. Close the lid to the WCS1-4 power supply, replace the retaining screw to the door latch, and  
then turn power on.  
SPARE FUSES  
FUSE HOLDER  
120V-  
240V-  
F
F
1.6A  
0.5A  
H
H
OUTPUT TERMINALS  
INPUT TERMINALS  
GROUND STUD  
Figure 4. Wiring Connector Diagram  
6
C561M-E (8/05)  
 
CABLE CONNECTIONS AND REQUIREMENTS  
Table A. Wiring Distances  
The following are the recommended maximum distances to wire the WCS1-4 to a Spectra III or  
Esprit positioning system.  
To determine the correct voltage tap:  
1. Pick the unit type.  
2. Find the wire gauge used (22 gauge is not recommended).  
3. Determine which secondary output tap (A, B, or C) is appropriate for the distance between the  
dome or positioning system and the WCS1-4. Distance is in feet (meters).  
MAXIMUM DISTANCE FROM TRANSFORMER TO LOAD  
20 AWG 18 AWG 16 AWG 14 AWG 12 AWG  
Spectra III Indoor (25 VA)  
(0.5 mm2) (1.0 mm2) (1.5 mm2) (2.5 mm2) (4.0 mm2)  
Tap A (24 VAC)  
113 (34)  
133 (40)  
155 (47)  
180 (55)  
287 (87) 455 (139) 725 (221)  
Tap B (26 VAC)  
212 (64) 337 (103) 536 (163) 852 (260)  
246 (75) 392 (119) 623 (190) 990 (302)  
Tap C (28 VAC)  
Environmental Spectra III and  
Esprit with IOC & IOP (70 VA)  
20 AWG 18 AWG 16 AWG 14 AWG 12 AWG  
(0.5 mm2) (1.0 mm2) (1.5 mm2) (2.5 mm2) (4.0 mm2)  
Tap A (24 VAC)  
Tap B (26 VAC)  
Tap C (28 VAC)  
41 (12)  
49 (15)  
55 (17)  
64 (19)  
78 (24)  
88 (27)  
102 (31)  
124 (38)  
135 (41)  
163 (50)  
198 (60)  
259 (79)  
315 (96)  
222 (68) 353 (107)  
20 AWG 18 AWG 16 AWG 14 AWG 12 AWG  
Esprit (50 VA)  
Tap A (24 VAC)  
Tap B (26 VAC)  
Tap C (28 VAC)  
(0.5 mm2) (1.0 mm2) (1.5 mm2) (2.5 mm2) (4.0 mm2)  
56 (17)  
66 (20)  
77 (23)  
90 (27)  
105 (32)  
122 (37)  
143 (43)  
168 (51)  
195 (59)  
228 (69) 362 (110)  
268 (81) 425 (129)  
311 (94) 493 (150)  
C561M-E (8/05)  
7
 
MAINTENANCE  
There are no user-serviceable parts except for the fuse. If the transformer in the WCS1-4 does not  
work properly, the entire environmental power supply needs to be returned to the factory for repair.  
Refer to the Warranty and Return Information for instructions on returning the WCS1-4.  
Clean the outer surface of the WCS1-4 box with a nonabrasive cleaning cloth and antistatic  
cleaner. Do not use kerosene or similar substances that may damage the surface.  
8
C561M-E (8/05)  
 
SPECIFICATIONS  
ELECTRICAL  
Input Voltage:  
Selectable 100, 120, 240 VAC, 50/60 Hz via the Primary Line Input connector  
strip  
Output  
Voltage/Power:  
Selectable 24 VAC (Tap A), 26 VAC (Tap B), or 28 VAC (Tap C) at 100 VA via  
the Secondary Output Tap’s connector strip  
Fusing:  
One fuse. Select from one of the following supplied fuses:  
Three 1.6 A fast-acting fuses (120 VAC)  
Three 500 mA fast-acting fuses (240 VAC)  
Spare Fuse  
Holder:  
Two spare fuse holders (attached to transformer cover)  
MECHANICAL  
Construction:  
Finish:  
Aluminum  
Gray polyester powder coat  
Cable Entry:  
Two hole plugs will accommodate 3/4-inch (1.91 cm) conduit fittings (not  
provided) that meet NEMA Type 4X standards.  
Mount Method:  
Latch:  
Four 0.375-inch (0.95 cm) holes on mounting plate  
One stainless steel link-lock latch secured with screw; latch also can be  
secured with padlock (not supplied)  
GENERAL  
Environment:  
Operating Range:  
Weight:  
Indoor/outdoor  
-50°F to 122°F (-45.56°C to 50°C)  
6.5 lb (2.95 kg)  
Dimensions:  
See Figure 5  
(Design and product specifications subject to change without notice.)  
This equipment contains electrical or electronic components that must be recycled properly to  
comply with Directive 2002/96/EC of the European Union regarding the disposal of waste  
electrical and electronic equipment (WEEE). Contact your local dealer for procedures for  
recycling this equipment.  
C561M-E (8/05)  
 
9
6.50 (16.51)  
5.63 (14.30)  
4.50 (11.43)  
4.00  
(10.16)  
7.88  
(20.02)  
6.44  
(16.36)  
5.88  
(14.94)  
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS;  
ALL OTHERS ARE INCHES.  
Figure 5. WCS1-4 Dimension Drawing  
10  
C561M-E (8/05)  
 
WARRANTY AND RETURN INFORMATION  
WARRANTY  
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of  
shipment.  
Exceptions to this warranty are as noted below:  
Five years on FT/FR8000 Series fiber optic products.  
Three years on Genex® Series products (multiplexers, server, and keyboard).  
Three years on Camclosure® and fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-  
2X camera models, which have a five-year warranty.  
Two years on standard motorized or fixed focal length lenses.  
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products.  
Two years on Spectra®, Esprit®, ExSite, and PS20 scanners, including when used in continuous motion applications.  
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).  
Eighteen months on DX Series digital video recorders, NVR300 Series network video recorders, and EnduraSeries distributed network-based  
video products.  
One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.  
Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).  
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight  
prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.  
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s  
liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products  
shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages  
(including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.  
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state  
to state.  
Ifawarrantyrepairisrequired, theDealermustcontactPelcoat(800) 289-9100or(559)292-1981toobtainaRepairAuthorizationnumber(RA), andprovide  
the following information:  
1. Model and serial number  
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number  
3. Details of the defect or problem  
Ifthereisadisputeregardingthewarrantyofaproductwhichdoesnotfallunderthewarrantyconditionsstatedabove,pleaseincludeawrittenexplanation  
with the product when returned.  
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.  
RETURNS  
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization  
number (CA number if returned for credit, and RA number if returned for repair).  
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.  
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate  
address below.  
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:  
Service Department  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699  
IfyouarelocatedoutsidethecontinentalU.S., Alaska, HawaiiorPuertoRicoandareinstructedtoreturngoodstotheUSA, youmaydooneofthefollowing:  
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:  
If the goods are to be sent by a COURIER SERVICE, send the goods to:  
Pelco c/o Expeditors  
Pelco  
473 Eccles Avenue  
3500 Pelco Way  
Clovis, CA 93612-5699 USA  
South San Francisco, CA 94080 USA  
Phone: 650-737-1700  
Fax: 650-737-0933  
® Pelco, the Pelco logo, Spectra, Genex, Coaxitron, Legacy, Esprit, Camclosure, Spectra III, and Spectra III SE are registered trademarks of Pelco.  
© Copyright 2003, Pelco. All rights reserved.  
REVISION HISTORY  
Manual #  
C561M  
C561M-A  
Date  
11/97  
12/98  
5/00  
Comments  
Original version.  
Changed model number. Revised Table A to update vA ratings for Spectra.  
Changed model number.  
C561M-B  
C561M-C  
C561M-D  
C561M-E  
6/00  
5/03  
11/03  
8/05  
Revised manual to support changes required for UL listing.  
Revised Wiring Distance section to include Spectra III and Esprit information. Updated manual to new format.  
Revised cover photo and Figure 5 to show new conduit hole plug per ECO 01-6947.  
Revised manual per ECO 05-11280 to change input power and a fuse value from 230 VAC to 240 VAC.  
C561M-E (8/05)  
11  
 
®
World Headquarters  
3500 Pelco Way  
Clovis, California 93612 USA  
USA & Canada  
Tel: 800/289-9100  
Fax: 800/289-9150  
International  
Tel: 1-559/292-1981  
Fax: 1-559/348-1120  
ISO9001  
Orangeburg, New York Las Vegas, Nevada Eindhoven, The Netherlands Wokingham, United Kingdom Montreal, Canada  
Singapore  
 

Philips CD Player AZ7794 User Manual
Philips Digital Camera PCVC690K User Manual
Philips Switch SWS3683W User Manual
Philips TV Cables SWA2520T User Manual
Pioneer CD Player DRM 1004XR21 User Manual
Polk Audio Speaker SC6S User Manual
Polycom Conference Phone 3726 17900 001 User Manual
Poulan Chainsaw 115327926 User Manual
Precor Treadmill 842i User Manual
ProForm Home Gym No 831290880 User Manual