Register your product and get support at
HX6733
4
EnglisH
iMPORTAnT sAFEgUARDs
READ ALL INSTRUCTIONS BEFORE USE
DAngERs
To reduce the risk of electrocution:
1
2
3
4
Do not place or store the product where it can
fall or be pulled into a tub or sink.
Do not place the product in or drop it into
water or any other liquid.
Do not reach for a product that has fallen into
water. Unplug immediately.
Do not use the product while bathing.
WARnings
To reduce the risk of burns, electrocution, fire to
persons:
1
Discontinue use if this product appears damaged in
any way (brush head, handle, charger and sanitizer).
This product contains no user-serviceable parts.
Refer to chapter‘Guarantee and service’ if your
Sonicare no longer works properly or needs repair.
Never use the charger or sanitizer if it has a
damaged cord or plug.
2
3
4
5
Keep the cord away from heated surfaces.
Do not use the charger or sanitizer outdoors.
Do not use the charger or sanitizer if dropped
into water.
6
This product is designed to clean your teeth,
gums and tongue only. Use this product only
for its intended use as described in this booklet.
Discontinue use of this product and contact
a physician/dentist if discomfort or pain is
experienced.
EnglisH
5
7
This appliance is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience
and knowledge, unless they have been given
supervision or instruction concerning use of the
appliance by a person responsible for their safety.
Children should be supervised to ensure that
they do not play with the appliance.
8
9
Do not use attachments other than those
recommended by the manufacturer.
10 If your toothpaste includes peroxide, baking soda
or other bicarbonate (common in whitening
toothpastes), thoroughly clean your brush head
and handle with soap and water after each use.
Otherwise plastic cracking may occur.
11 To avoid damage to the product, do not place
the brush head, handle, sanitizer, charger or
charger covers in the dishwasher for cleaning.
12 Discontinue use of the sanitizer if the UV light bulb
remains on when the door is open. UV light can
be harmful to the human eye and skin. Keep the
sanitizer out of the reach of children at all times.
13 Do not operate the UV sanitizer without the
protective screen in place to avoid contact
with hot bulb.
14 The UV light bulb is hot during and immediately
after the sanitizing cycle. Do not touch the UV
light bulb when it is hot.
15 Do not operate the UV sanitizer where aerosol
(spray) products are being used or where
oxygen is being administered.
16 If the sanitizer is used for 3 consecutive UV clean
cycles (i.e., 3 times in a row) a minimum of 30
minutes ‘OffTime’ is required before you start
another UV clean cycle.
6
EnglisH
MEDiCAlWARnings
1
2
3
Consult your dental professional before you use
this product if you have had oral or gum surgery
in the previous 2 months.
Contact your dental professional if excessive
bleeding occurs after using this product or
bleeding continues to occur after 1 week of use.
If you have a pacemaker or other implanted
device contact your physician or the device
manufacturer prior to use.
4
5
Sonicare has been tested and is compliant with
safety standards for electromagnetic devices.
Consult your physician prior to using the
Sonicare if you have medical concerns.
SAVETHESE INSTRUCTIONS
Your sonicare (Fig. 1)
A
B
C
Hygienic travel cap
Brush head
Interchangeable color code ring
D Handle with soft grip
E
F
Power on/off button
Brushing modes
G Charge light indicator
- Deluxe charge indicator (select models)
- Standard charge indicator (select models)
H Deluxe charger (select models)
1
2
3
Charger cover with brush head holder
Travel charger
Charger base with cord wrap
EnglisH
7
I
UV sanitizer with integrated charger and cord wrap
- Not shown: UV light bulb
- Not shown: Sanitizer drip tray
- Not shown: Protective screen for UV light bulb
Note:The contents of the box vary based on model
purchased
getting started
Changing the color code ring
Sonicare brush heads come with interchangeable
color code rings to identify your brush head.
To change the color code ring:
1 Pull the color code ring from the bottom of
the brush head.
2 Install a new ring by slipping one edge of the
new ring over the bottom of the brush head.
Then press down on the other side to snap the
ring into place.
Attaching the brush head
1 Align the brush head so the bristles face the
front of the handle.
2 Firmly press the brush head down onto the
metal shaft until it stops.
Note:There is a small gap between the color code ring
and the handle.
8
EnglisH
Charging your sonicare
1 Plug the charger into a live outlet.
2 Place the handle on the charger.
, The battery charge indicator next to the battery
symbol flashes to indicate that the toothbrush is
charging.
Battery charge indicator
The battery charge indicator shows the approximate
remaining battery charge.
Deluxe charge indicator (select models):
- Solid green: 50-100%
- Flashing green: 10-49%
- Flashing yellow: less than 10%
Standard charge indicator (select models):
- Solid green: 50-100%
- Flashing green: less than 50%
Note:When the battery of your Sonicare is low, you hear
3 beeps after the completion of the brushing cycle and
the battery charge indicator flashes for 30 seconds.
Note:To keep the battery fully charged, you may
keep your Sonicare on the charger when not in use. It
takes 24 hours to fully charge the battery.
EnglisH
9
Using your sonicare
Brushing instructions
1 Wet the bristles and apply a small amount of
toothpaste.
2 Place the toothbrush bristles against the teeth
at a slight angle towards the gumline.
3 Press the power on/off button to turn on the
Sonicare.
4 Apply light pressure to maximize Sonicare’s
effectiveness and let the Sonicare toothbrush
do the brushing for you.
5 Gently move the brush head slowly across
the teeth in a small back and forth motion
so the longer bristles reach between your
teeth. Continue this motion throughout
your brushing cycle.
Note:To make sure you brush evenly throughout the
mouth, divide your mouth into 4 sections using the
Quadpacer feature (see chapter ‘Features’).
6 Begin brushing in section 1 (outside top teeth)
and brush for 30 seconds before moving to
section 2 (inside top teeth). Continue brushing
in section 3 (outside bottom teeth) and brush
for 30 seconds before moving to section 4
(inside bottom teeth).
7 After you have completed the brushing
cycle, you can spend additional time brushing
the chewing surfaces of your teeth and areas
where staining occurs.You may also brush your
tongue, with the toothbrush turned on or off,
as you prefer.
10 EnglisH
Your Sonicare is safe to use on:
- Braces (brush heads wear out sooner when used
on braces)
- Dental restorations (fillings, crowns, veneers)
Note:The toothbrush may be turned off at any time
by pressing and holding the power on/off button for
2 seconds.
Clean andWhite mode brushing
instructions
The Clean and White mode combines 2 minutes
of Clean mode for a whole mouth clean, with an
additional 30 seconds of White mode to focus on
the visible front teeth.
1 Brush the first 2 minutes as instructed in steps
1-6 above.
2 After the 2 minutes of Clean mode, the
White mode begins with a change in brushing
sound and motion.That is your signal to start
brushing the upper front teeth for 15 seconds
3 At the next beep and pause, move to the
bottom front teeth for the final 15 seconds of
brushing.
Brushing modes
Sonicare automatically starts in the default Clean
mode.To select a different brushing mode:
1 Press the on/off button to toggle between
modes.
, The green LED indicates the selected mode.
Note:You can only switch between modes when the
toothbrush is turned on.
EnglisH 11
Clean mode
Standard mode for superior teeth cleaning.
sensitive mode (select models)
Gentle, yet thorough cleaning for sensitive gums and
teeth.
Clean andWhite mode
2 minutes of Clean mode, with an additional 30 seconds
of White mode to focus on your visible front teeth.
Note:When Sonicare is used in clinical studies, the
default 2-minute Clean mode must be selected.
However, in whitening/stain reduction studies, the Clean
andWhite mode must be selected.The handle should
be fully charged and the Easy-start feature deactivated.
Features
Easy-start
- This Sonicare model comes with the Easy-start
feature activated.
- The Easy-start feature gently increases power over
the first 14 brushings to ease into the Sonicare
experience.
Note: Each of the first 14 brushings must be at least 1
minute in length to move through the Easy-start ramp-
up cycle properly.
Note:When the Clean andWhite mode is selected, the
Easy-start feature is inactive.
Deactivating or activating the Easy-start
feature
1 Attach your brush head to the handle.
2 Place the handle in the plugged-in charger.
12 EnglisH
- To deactivate Easy-start:
Press and hold the power on/off button for 2
seconds.You hear 1 beep to indicate that the Easy-
start feature has been deactivated.
- To activate Easy-start:
Press and hold the power on/off button for 2
seconds.You hear 2 beeps to indicate that the Easy-
start feature has been activated.
Note: Using the Easy-start feature beyond the initial
ramp-up period is not recommended and reduces
Sonicare’s effectiveness in removing plaque.
smartimer
The Smartimer indicates that your brushing cycle is
complete by automatically turning off the toothbrush
at the end of the brushing cycle.
Dental professionals recommend brushing no less
than 2 minutes twice a day.
If you want to pause or stop brushing during your
2-minute cycle, press and hold the power on/off
button for 2 seconds. Press the power on/off button
again and the Smartimer picks up where you left off.
The Smartimer automatically resets to the beginning
of a 2-minute cycle if:
- brushing is paused for 30 seconds or longer.
- the handle is returned to the charger.
Quadpacer (select models)
- The Quadpacer is an interval timer that has a
short beep and pause to remind you to brush the
4 sections of your mouth evenly and thoroughly.
- When you use the two-minute Clean or Sensitive
mode, you hear a short beep and a pause in
brushing action at 30, 60 and 90 second intervals.
EnglisH 13
- When you use the Clean and White mode, you
hear and feel a change in the brush head sound
and motion after 2 minutes of Clean mode.Then
move the brush head to the visible top front teeth
and brush them for 15 seconds.At the final beep
and pause, move to the visible bottom teeth and
brush them for 15 seconds.
Cord wrap on deluxe charger (select models)
If your model includes the deluxe charger cover and
base, the travel charger is pre-installed inside the
cover. If you want to shorten the power cord, you
can store excess cord in the cord wrap feature built
into the charger base.
1 To separate the charger cover from the
charger base, press the two gray snap bars on
the charger base and pull the white charger
cover upwards.
2
Wrap excess power cord around the gray charger
base as shown in the picture. Be sure to wrap the
cord on the inside of the two snap levers.
3 When you have stored the excess cord, guide
the power cord through the small groove in
the rear of the gray charger base.
4 Reattach the charger cover by pressing it down
over the charger base until it snaps into place.
14 EnglisH
Tip: For extra convenience during travel, you can
remove the travel charger and use it without the
charger cover and charger base.
Cord wrap on sanitizer with integrated charger
1 If your model includes the sanitizer, you can
store excess cord using the cord wrap feature
built into the bottom of the sanitizer.
sanitizing (select models)
- With the UV sanitizer you can clean your brush
head after every use.
Discontinue use of the sanitizer if the UV light bulb
remains on when the door is open or if the blue
window is broken or missing from the sanitizer.
UV light can be harmful to the human eye and skin.
This device should be kept out of reach of children
at all times.
Unplug the sanitizer and call Consumer Care if the
sanitizer gives off smoke or a burning smell while it
is operating..
1 After brushing, rinse the brush head and shake
off excess water.
Do not place the travel cap on the brush head
during sanitization.
2 Place your finger in the door recess on top of
the sanitizer and pull open the door.
EnglisH 15
3
Place the brush head on one of the 2 pegs in
the sanitizer.
Note: Only clean Sonicare ProResults brush heads in
the sanitizer.
Make sure the bristles of the brush head directly
face the light bulb.
4 Make sure the sanitizer is plugged into a live
outlet of appropriate voltage.
5 Close the door and press the green power on/
off button once to select the UV clean cycle.
Note:You can only turn on the sanitizer if the door is
properly closed.
Note:The sanitizer stops if you open the door during
the sanitizing cycle.
Note:The sanitizer cycle runs for 10 minutes and then
automatically shuts off.
, The sanitizer is in operation when the blue light
glows through the window.
, When the sanitizing cycle is complete, the
sanitizer automatically shuts off.
Cleaning
Do not clean the brush heads,handle,charger, charger
covers or the UV sanitizer in the dishwasher.
Toothbrush handle
1 Remove the brush head and rinse the metal
shaft area with warm water.
Do not push on the rubber seal on the metal shaft
with sharp objects, as this may cause damage.
16 EnglisH
2 Use a damp cloth to wipe the entire surface of
the handle.
Brush head
1 Rinse the brush head and bristles after each use.
2 Remove the brush head from the handle and
rinse the brush head connection at least once a
week with warm water.
Charger
1 Unplug the charger before cleaning.
2 Use a damp cloth to wipe the surface of
the charger.
Brush head UV sanitizer (select models)
Do not clean the sanitizer when the UV light bulb
is hot.
For optimal effectiveness, it is recommended to
clean your sanitizer weekly.
1 Unplug the sanitizer.
2 Pull the drip tray straight out. Rinse the drip
tray and wipe it clean with a damp cloth.
3 Clean all reflector surfaces with a damp cloth.
4 Remove the protective screen in front of the
UV light bulb.
To remove the screen, grasp the edges next to the
snaps, gently squeeze and pull out the protective screen.
5 Remove the UV light bulb.
EnglisH 17
To remove the light bulb, grasp it and pull it out of
the metal clasp.
6 Clean the protective screen and the UV light
bulb with a damp cloth.
7 Reinsert the UV light bulb.
To reinsert the light bulb, align the bottom of the
light bulb with the metalclasp and push the bulb into
the clasp.
8 Reinsert the protective screen.
To reinsert the screen, align the pegs on the screen
with the slots on the reflective surface near the UV
light bulb. Push the screen straight into the slots on
the sanitizer.
storage
- If you are not going to use the product for an
extended period of time, unplug it from the
electrical outlet, clean it and store it in a cool and
dry place away from direct sunlight.You can use
the cord wrap (select models) to store the power
cord in an organized manner.
- You can store brush heads on the pegs at the
back of the charger.
Replacement
Brush head
- Replace Sonicare brush heads every 3 months to
achieve optimal results.
- Use only compatible Sonicare replacement brush
heads.
18 EnglisH
UV light bulb
- Replacement UV bulbs are available through
your Sonicare Consumer Care Center in North
America by calling 1-800-682-7664. Outside
North America, contact your local Philips
Consumer Care Center.
Disposal
- At the end of product life and prior to disposal,
please remove the rechargeable battery from the
handle by following the instructions below.
- Do not throw away the appliance or the UV light
bulb (bulb contains mercury) with the normal
household waste at the end of its life, but hand
it in at an official collection point for recycling. By
doing this, you help to preserve the environment.
- The built-in rechargeable battery contains
substances that may pollute the environment.
Always remove the battery before you discard the
appliance, and recycle or dispose of the battery
according to local waste management requirements.
- If you have any recycling questions, contact your
local waste management office.
Removing the rechargeable battery
Please note that this process is not reversible.
- To remove the rechargeable battery, you need a
flat-head (standard) screwdriver. Observe basic
safety precautions when you follow the procedure
outlined below. Be sure to protect your eyes,
hands, fingers, and the surface on which you work.
1 To deplete the rechargeable battery of any
charge, remove the handle from the charger,
turn on the Sonicare and let it run until it
stops. Repeat this step until you can no longer
switch on the Sonicare.
EnglisH 19
2 Insert a screwdriver into the slot
located at the bottom of the handle and
turn counterclockwise to release the bottom cap.
3 Hold the handle upside down and push
down on the shaft to release the internal
components of the handle.
4 Insert the screwdriver under the circuit board,
next to the battery connections, and twist to
break the connections. Remove the circuit board
and pry the battery from the plastic carrier.
The rechargeable battery can now be recycled or
disposed of and the rest of the product discarded
appropriately.
Warranty and service
Philips guarantees its products for two years after
the date of purchase. Defects due to faulty materials
and workmanship will be repaired or replaced at
Philips expense provided that convincing proof of
purchase in the qualifying period is provided.
Use of unauthorized replacement parts will void
this warranty.
Contact our Customer Service Center at 1-800-
682-7664 (North America), outside North America
contact your local Philips Customer Care Center.
20 EnglisH
WARRAnTY EXClUsiOns
What is not covered under warranty:
- Brush heads.
- Damage caused by misuse, abuse, neglect,
alterations or unauthorized repair.
- Damage caused by use of unauthorized
replacement parts.
- Normal wear and tear, including chips, scratches,
abrasions, discoloration or fading.
- UV light bulb.
iMPliEDWARRAnTiEs
ANY IMPLIED WARRANTIES, INCLUDING
IMPLIED WARRANTIES OF MERCHANTABILITY
AND FITNESS FOR A PARTICULAR PURPOSE,
SHALL BE LIMITEDTOTHE DURATION OFTHE
EXPRESS WARRANTIES SET FORTH ABOVE. IN
SOME STATES LIMITATIONS ON DURATION OF
IMPLIED WARRANTIES DO NOT APPLY.
liMiTATiOn OF REMEDiEs
IN NO EVENT SHALL PHILIPS OR ANY OF
ITS AFFILIATED OR SUBSIDIARY COMPANIES
BE LIABLE FOR ANY SPECIAL, INCIDENTAL
OR CONSEQUENTIAL DAMAGES BASED
UPON BREACH OF WARRANTY, BREACH OF
CONTRACT, NEGLIGENCE,TORT, OR ANY
OTHER LEGALTHEORY. SUCH DAMAGES
INCLUDE,WITHOUT LIMITATION, LOSS OF
SAVINGS OR REVENUE; LOSS OF PROFIT;
LOSS OF USE;THE CLAIMS OFTHIRD PARTIES
INCLUDING,WITHOUT LIMITATION, DENTISTS
AND DENTAL HYGIENISTS;AND COST OF ANY
SUBSTITUTE EQUIPMENT OR SERVICES. SOME
STATES DO NOT ALLOWTHE EXCLUSION
OR LIMITATION OF INCIDENTAL OR
CONSEQUENTIAL DAMAGES.
EnglisH 21
Frequently asked questions
This chapter lists the questions most frequently
asked about the appliance. If you cannot find the
answer to your question, contact the Customer Care
Center in your country.
Question
Answer
Why doesn’t the
Sonicare work?
You may need to recharge the Sonicare. Charge
the Sonicare for at least 24 hours.
Make sure that your Sonicare charger is plugged
into a live electrical outlet and not into an outlet
controlled by a light switch.
You may need to reattach or replace the brush
head.
Why do I feel a
tickling sensation
when I use the
Sonicare?
You may experience a slight tickling/tingling
sensation when you use the Sonicare for the first
time.As you become accustomed to brushing
with Sonicare, this sensation diminishes.
The brush head
To avoid this, keep the brush head properly
chatters against my oriented, with the bristles placed on the gumline
teeth.What can I
do about this?
at a slight angle.
Why does the
Sonicare seem less
powerful?
You may need to charge the Sonicare.
The Easy-start feature may be on. Deactivate the
Easy-start feature (See chapter ‘Features’).
You may need to replace your brush head.
22 EnglisH
Question
Answer
Why does the
Sonicare seem
to change power
during brushing?
You may be in the Clean and White brushing
mode. If this is the case, the toothbrush starts in
the Clean mode for 2 minutes and then changes
to the White mode for 30 seconds. The Clean
and White mode has a different sound and
brush movement.
Do I need a special Travel tip: the Sonicare charger can be used with
charger if I travel
with my Sonicare?
common worldwide voltages between 100-
240V AC, at either 50 or 60Hz.A simple plug
adapter is all that is required.
Why doesn’t the
UV sanitizer light
go on?
You may need to plug the sanitizer into a live
outlet.
You may need to shut the door of the sanitizer.
You may need to replace the UV light bulb (see
chapter‘Replacement’).
Protected by U.S. and international patents. Other patents pending.
Reg. U.S. Pat. &Tm.Off.
@2012 Koninklijke Philips Electronics NV (KPENV).All rights reserved.
PHILIPS and Philips shield are registered trademarks of KPENV. Easy-
start, Quadpacer, Sonicare and the Sonicare logo are trademarks of
Philips Oral Healthcare, Inc. and/or KPENV
4235.020.3710.3
|