Philips T5VHO Extreme
Temperature System
Ideal for high-bay
applications without
climate control
T5 COLLECTION
† This lamp is better for the environment because of
its reduced mercury content.All Philips ALTO®
lamps give you end-of-life options which can simplify
and reduce your lamp disposal costs depending on
your state and local regulations.
Lower the costs of your ceilings
With the Philips T5 VHO Extreme Temperature System,
you can useT5 lamps in high-bay applications without
sacrificing light output due to hot or cold temperatures.
Provides high light output even in spaces without climate control
• Lumen output is >90% from 65˚F to 170˚F (20˚C to 75˚C) due to amalgam technology
• More light over the life of the lamp than a standard 400W HID system*
Operates on existing electrical system
• 277V–480V input voltage range eliminates the need for rewiring
your electrical system
Reduce total cost of ownership (TCOO) when compared to a
standard HID 400W system
• Reduced energy costs—save up to 40 system watts‡
• Reduced maintenance costs—up to 75% longer lamp life◊ which extends
the relamping cycle
• Reduced costs since less lamps are needed to meet lumen requirements**
(*, ‡, ◊, ** See page 2 for footnotes)
Advance 277V–480V (1) or (2) lamp 95WT5VHO Ballast
Ballast Ordering, Electrical andTechnical Data
Lamp
Starting
Method
Maximum
Input Power
ANSI (Watts)
Min.
Starting
Temp(˚F/˚C)
No. of
Lamps
Input
Volts
Ballast
Family
Catalog
Number
Ballast
Factor
Line Current
(Amps)
1
1
1
2
2
2
277
347
480
277
347
480
PS
PS
PS
PS
PS
PS
Optanium
Optanium
Optanium
Optanium
Optanium
Optanium
JOP-2S95-G
JOP-2S95-G
JOP-2S95-G
JOP-2S95-G
JOP-2S95-G
JOP-2S95-G
116W
116W
116W
206W
206W
206W
1.1
1.1
1.1
1.0
1.0
1.0
0.42A
0.35A
0.24A
0.74A
0.59A
0.43A
-19/-28
-19/-28
-19/-28
-19/-28
-19/-28
-19/-28
Above specifications subject to change without notice.
Features
• Programmed Start ballast
• Ballast factor of 1.0 for 2-lamp version
• 277V–480V input voltage range, 50/60Hz
• 194˚F/90˚C maximum case temperature
• -19˚F (-28˚C) minimum starting temperature
• <10% Total Harmonic Distortion (THD)
• One or two lamp operation
General Specifications
Section I—Physical Characteristics
1.1 The electronic ballast shall be furnished with integral leads color coded
to ANSI standard C82.11.
2.10 The electronic ballast shall be a high frequency electronic type
and operate above 40 kHz to avoid interference with infrared
control systems, and eliminate visible flicker.
2.11The electronic ballast shall comply with ANSI C82.11, where applicable.
2.12 The electronic ballast shall provide transient immunity as specified
in ANSI C62.41.
2.13 The electronic ballast shall provide end of life protection circuitry.
2.14 The electronic ballast shall have a minimum starting temperature
of -19°F (-28°C) for T5VHO lamps.
Section II—Performance Requirements
2.1 The electronic ballast shall be programmed start.
2.2 The electronic ballast shall operate from 250V–528V.
2.3 The electronic ballast shall maintain constant light output, for line
voltage variations of 10% of rated supply voltage.
2.4 The electronic ballast input current shall have Total Harmonic
Distortion (THD) of less than 10% at maximum light output
for primary lamps.
2.5 The electronic ballast shall have a Power Factor greater than 98%
at full light output.
2.6 The electronic ballast shall have a minimum ballast factor of 1.0
for primary lamp applications.
Section III—Regulatory Requirements
3.1 The electronic ballast shall not contain any Polycholorinated
Biphenyl (PCB’s).
3.2 The electronic ballast shall be Underwriters Laboratories (UL 935)
listed, Class P and Type 1 Outdoor; and Canadian Standards
Association (CSA) certified, where applicable.
2.7 The electronic ballast lamp current crest factor shall be 1.7 or less
in accordance with lamp manufacturer recommendation.
2.8 The electronic ballast shall withstand a sustained open circuit and
output conditions without damage.
Section IV—Other
4.1 The manufacturer shall have a fifteen-year history of producing
electronic ballasts for the North American market.
4.2 The electronic ballast shall be produced in a factory certified
to ISO 9001 Quality System Standards.
2.9 The electronic ballast shall be Sound Rated A.
Wiring Diagram–Lamp Operation
Advance JOP-2S95-G T5VHO for 2-lamp version ballast
RED
RED
BLACK/ORANGE
(HOT)
BLACK/ORANGE
(HOT)
YELLOW
YELLOW
BALLAST
BALLAST
BLACK/WHITE
BLACK/WHITE
(NEUTRAL )
(NEUTRAL )
BLUE
BLUE
Yellow leads must be connected for (1) lamp operation
Enclosure Dimensions
Advance JOP-2S95-G T5VHO Ballast
A . . . . . . . 1.18"
B . . . . . . . 1.70"
C . . . . . . 16.34"
D . . . . . . 16.70"
Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
A Division of Philips Electronics North America Corporation
Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
10275 West Higgins Road
Rosemont, IL 60018-5603
1-800-322-2086
A Division of Philips Electronics North America Corporation
©2008 Philips Lighting Company, A Division of Philips Electronics North America Corporation
All rights reserved. Reproduction in whole or part is prohibited without the prior written consent of the copyright owner.The information
presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed
without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any
license under patent or other industrial or intellectual property rights. Data subject to change without notice.
09/08
P-5904-A
|