Pioneer Flat Panel Television PDP 614MX and PDP 424MV User Manual |
External Control Manual
RS-232C Configuration
(for PDP-614MX and PDP-424MV)
Version 1.0
Dec 2005
PDP-614MX External Control Manual
2) Connector on the external equipment side: Serial port (RS-232C) connector. See the specifications of the equipment that is
to be connected for the type of connector and the pin assignment.
3) Wiring
Use a crossed (reverse) cable.
Wire the cable so that each pair of data lines cross between the two devices. These data line pairs are RXD (Receive data)
and TXD (Transmit data), DTR (DTE side ready) and DSR (DCE side ready), and RTS (Ready to send) and CTS (Clear to
send).
Communication Parameters
(1) Communication system
(2) Interface
Asynchronous
RS-232C
(3) Baud rate*
1200/2400/4800/9600(default)/19200/38400bps
(4) Data length
(5) Parity
8 bits
Non
1 bit
(6) Stop bit
(7) Communication code
(8) Flow control
Hex
Non
* Selectable in the service menu.
3
PDP-614MX External Control Manual
Communication Format
8bit 8bit 8bit 8bit 8bit 8bit
8bit 8bit
Command 1
Unit ID 1
Unit ID 2
Command 2
Data length
Data
Check sum
Command1
Command 1, along with command 2, is a number used to distinguish each command.
When making it operate using ID, bit1 and bit0 are set up as follows.
Bit1,Bit0 Unit ID distinction bit
11B
10B
01B
00B
:Usually, a form (with no ID)
:Usually, a form (with no ID)
:Set ID
:Video wall ID
In the case of ACK, when the lower order 4 bits is FH (as in 3FH and 7FH), this indicates that the commands and
data of the supported equipment have been received. When the lower order 4 bits is BH (as in 3BH and 7BH),
this indicates that unsupported commands and data have been received.
Unit ID1,2 (UA1,UA2)
Unit ID 1 and unit ID 2 are numbers used to identify the equipment that is to be connected.
60H is used for the plasma monitor and 80H is used for external control equipment such as a personal computer.
1)Unit ID 1: Indicates the equipment sending the signal. When supporting Set ID by the command 1, 4 bits of low
ranks of Set ID are set up.
2)Unit ID 2: Indicates the equipment receiving the signal. When supporting Set ID by the command 1, 4 bits of
higher ranks of Set ID are set up.
* Set ID : it is the apparatus number assigned to each plasma monitor.
Command 2
Command 2, along with command 1, is a number used to distinguish each command.
Check Sum (CKS), Error Processing, and ACK
1) The check sum described below and RS-232C odd parity are used together for a check of the received data. The check sum is
4
PDP-614MX External Control Manual
the lower order 8 bits of one frame of sent or received data comprising the sum total of Command 1, Unit ID 1 and 2,
Command 2, Data Length, and Data.
Check Sum Example
DFH
80H
60H
47H
01H
01H
08H
Command1
Unit ID1
Unit ID2
Command2 Data Length
Data
Check Sum
Total 208H
2) Error Processing
• When the communication interval is vacant for more than 4 ms, thereafter a received Command 1 will be recognized. If, at
this time, meaningful data cannot be recognized, that data will not be recognized (as valid data).
• An ACK will not be returned unless the receive data error, the check sum error, and the receive data are all taken in.
5
PDP-614MX External Control Manual
The control method of the set by Set ID
When controlling two or more sets of plasma monitors, if the command using Set ID is used, it will become controllable
individually.
The example of the POWER ON command to the plasma monitor which set ID as "5" is shown below.
It is not based on ID but is the POWER ON command to all sets.
9F 80 60 4E 00 CD
In ID= "5", the value of ID-1=4 is set up.
9D 84 60 4E 00 CF
The example of a change in the single mode of a 4th page multi-system configuration and the multi-mode is shown below.
ID of the set used as a master(etc PC) is set to 50, and it assumes that ID is shaken by AUTO ID to each set. ID shaken at each set is as
follows.
Upper left set (master) ID = 50 = 32h
Upper right set ID = 51 = 33h
Lower right set ID = 52 = 34h
Lower left set ID = 53 = 35h
Transmission Data
DD 81 63 03 03 03 01 00 CB
DD 82 63 03 03 03 02 00 CD
DD 83 63 03 03 03 03 00 CF
DD 84 63 03 03 03 04 00 D1
Transmission of the above command performs a 4th page multi SPLIT display.
Moreover, the following commands are published in order to change a 4th page multi-display into a single mode display.
DF 80 60 03 03 01 01 00 C7
All sets become a single mode display by the above-mentioned command.
Since this command does not specify Set ID, all sets execute it.
*:Control by ID may not be able to be performed depending on connection with external control apparatus.
6
PDP-614MX External Control Manual
Command Reference List
CMD1
9FH
9FH
DFH
DFH
9FH
9FH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
DFH
1FH
DFH
DFH
DFH
DFH
DFH
DFH
1FH
1FH
1FH
1FH
1FH
1FH
DFH
DFH
DFH
1FH
DFH
5FH
1FH
DFH
DFH
DFH
DFH
CMD2
4EH
4FH
47H
7FH
3EH
3FH
7FH
7FH
7FH
7FH
7FH
0AH
00H
7FH
7FH
7FH
C0H
7FH
7FH
7FH
51H
7FH
7FH
7FH
7FH
7FH
7FH
7FH
1AH
1AH
C6H
C1H
6BH
C8H
54H
70H
8CH
8BH
8AH
5BH
5CH
26H
41H
45H
6FH
3FH
17H
0CH
0DH
13H
88H
5FH
61H
15H
89H
65H
8EH
8FH
LEN
00H
00H
01H
03H
00H
00H
03H
03H
03H
03H
03H
01H
01H
04H
04H
04H
01H
03H
03H
03H
01H
03H
03H
03H
03H
03H
03H
03H
02H
02H
01H
01H
03H
04H
00H
02H
01H
01H
01H
01H
01H
00H
00H
00H
00H
00H
00H
01H
08H
04H
00H
01H
01H
00H
01H
01H
01H
01H
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
Power ON
Power OFF
Input Switch Change
VOLUME Gain Data
AUDIO Mute ON
AUDIO Mute OFF
CONTRAST Gain Data
BRIGHT Gain Data
SHARPNESS Gain Data
Color Gain Data
TINT Gain Data
AV SELECTION Select
COLOR TEMP SELECT
RED Gain Data
GREEN Gain Data
BLUE Gain Data
DNR MODE Set
BASS Gain Data
TREBLE Gain Data
BALANCE Gain Data
SCREEN SIZE Select
V.POSITION Gain Data
H.POSITION Gain Data
V-SIZE Gain Data
H-SIZE Gain Data
AUTO PICTURE Select
PHASE Gain Data
CLOCK Gain Data
OSM ADJ. position Data
POWER MGT Select
SIDE MASK Set
PURECINEMA Set
LONG LIFE Set
SCREEN WIPER Set
ALL RESET
Audio Inut Set
BNC INPUT
RGB Select
HD Select
LANGUAGE Select
COLOR SYSTEM Select
FREQUENCY Request
Input MODE Request
VIDEO ADJ Request
Audio Select Request
Failure Mode Request
MODEL NAME Request
LOW TONE
C.DETAIL ADJ
GAMMA Gain Data
Running Sense
OSM OBITER
Input Skip
SERIAL No. Request
S1/S2 SELECT
SOFT FOCUS
PLUG and PLAY
BLACK LEVEL
(DIGITAL SIGNAL LEVEL)
OSM CONTRAST
59
DFH
37H
01H
7
PDP-614MX External Control Manual
29
35
51
54
OSM Select
INVESE Set
TIMER SWITCH
TIMER
DFH
DFH
DFH
58H
C7H
02H
30H
01H
03H
01H
08H
PROGRAM DFH
SETTING
55
56
57
58
59
60
61
PRESENT TIME SETTING
MULTI MODE Select
MULTI MODE Request
AUTO ID SET START
PLE LINK
VIDEO WALL SETTING
POWER DELAY ON
(DIVIDER setting : 1/4/9)
POWER DELAY ON
(DIVIDER setting : 16/25)
ORBITTER SET
DFH
DFH
1FH
5FH
DFH
DFH
DFH
31H
03H
3BH
F0H
F1H
F3H
F2H
03H
03H
00H
01H
03H
02H
01H
62
DFH
F6H
01H
65
67
DFH
DFH
DFH
DFH
DFH
1EH
60H
2AH
63H
64H
04H
01H
01H
04H
06H
OSM ANGLE
69*1 PICTURE Size
70
71
OPTION Select
REPEAT Timer
8
PDP-614MX External Control Manual
01. Power ON
Function
The external control equipment switches on the power of the plasma monitor.
Transmission Data
9FH 80H 60H 4EH 00H CKS
ACK
The plasma monitor returns the following ACK when the power is switched on.
3FH 60H 80H 4EH 00H CKS
NOTE: Do not set the Power ON or Power OFF command continuously.
02. Power OFF
Function
The external control equipment switches off the power of the plasma monitor.
Transmission Data
9FH 80H 60H 4FH 00H CKS
ACK
The plasma monitor returns the following ACK when the power is switched off.
3FH 60H 80H 4FH 00H CKS
NOTE: Do not set the Power ON or Power OFF command continuously.
9
PDP-614MX External Control Manual
03. Input Switch Change
Function
The external control equipment switches the input of the plasma monitor.
Transmission Data
DFH 80H 60H 47H 01H DATA00
CKS
DATA00 : Input Select
01H : Video1
02H : Video2
03H : Video3
05H : COMPNT1
06H : COMPNT2
07H : PC1DSUB
08H : PC2-BNC
0CH : PC3-DVI
ACK
The plasma monitor returns the following ACK when the input is switched.
3FH 60H 80H 47H 00H CKS
10
PDP-614MX External Control Manual
04. VOLUME Gain Data
Function
The external control equipment changes the VOLUME gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02
DATA00: USER SOUND Gain Flag 05H
CKS
DATA01: VOLUME Gain Flag
DATA02: VOLUME Gain
01H
00H: Step0
:
0AH: Step10 (Default)
:
2AH: Step42
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER SOUND Gain Flag
05H
DATA01: VOLUME Gain Flag
01H
05. AUDIO Mute ON
Function
The external control equipment switches on AUDIO Mute of the plasma monitor.
Transmission Data
9FH 80H 60H 3EH 00H CKS
ACK
3FH 60H 80H 3EH 00H CKS
06. AUDIO Mute OFF
Function
The external control equipment switches off AUDIO Mute of the plasma monitor.
Transmission Data
9FH 80H 60H 3FH 00H CKS
ACK
3FH 60H 80H 3FH 00H CKS
11
PDP-614MX External Control Manual
07. CONTRAST Gain Data
Function
The external control equipment changes the CONTRAST gain data of the plasma c
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02
CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : CONTRAST Gain Flag
DATA02 : CONTRAST Gain
01H
07H
CCH : -52
:
FFH : -01
00H : 0
01H : +01
:
14H : +20
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: CONTRAST Gain Flag
07H
08. BRIGHT Gain Data
Function
The external control equipment changes the BRIGHT gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02
CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : BRIGHT Gain Flag
DATA02 : BRIGHT Gain
01H
08H
E0H : -32
:
FFH : -01
00H : 0
01H : +01
:
20H : +32
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00 : USER PICTURE Gain Flag
01H
DATA01 : BRIGHT Gain Flag
08H
09. SHARPNESS Gain Data
Function
The external control equipment changes the SHARPNESS gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : SHARPNESS Gain Flag
DATA02 : SHARPNESS Gain
01H
06H
F0H : -16
:
FFH : -01
00H : 0
12
PDP-614MX External Control Manual
01H : +01
:
10H : +16
Only when a RGB signal is connected
DATA02 : SHARPNESS Gain
01H : 1
02H : 2
03H : 3
04H : 4
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00 : USER PICTURE Gain Flag
01H
DATA01 : SHARPNESS Gain Flag
06H
13
PDP-614MX External Control Manual
10. COLOR Gain Data
Function
The external control equipment changes the COLOR gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : COLOR Gain Flag
DATA02 : COLOR Gain
01H
04H
E0H : -32
:
FFH : -01
00H : 0
01H : +01
:
20H : +32
* COLOR Gain is from -22 (EAH) to +22 (16H) only during video.
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00 : USER PICTURE Gain Flag
01H
DATA01 : COLOR Gain Flag
04H
11. TINT Gain Data
Function
The external control equipment changes the TINT gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : TINT Gain Flag
DATA02 : TINT Gain
01H
05H
E0H: -32
:
* TINT Gain is from -22 (EAH) to
+22 (16H) only during video.
FFH : -01
00H : 0
01H : +01
:
20H : +32
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00 : USER PICTURE Gain Flag
01H
DATA01 : TINT Gain Flag
05H
12. AV SELECTION Select
Function
The external control equipment sets the av selection of the plasma monitor.
Transmission Data
DFH 80H 60H 0AH 01H DATA00 CKS
DATA00: 01H : STD
02H : MOVIE1*
03H : MOVIE2*
04H : Default
05H : Dynamic*
* It cannot choose in the still picture input of a personal computer
14
PDP-614MX External Control Manual
ACK
7FH 60H 80H 0AH 01H DATA00 CKS
DATA00: 01H : STD
02H : MOVIE1
03H : MOVIE2
04H : Default
05H : Dynamic
13. COLOR TEMP SELECT
Function
The external control equipment changes the COLOR TEMP of the plasma monitor.
Transmission Data
DFH 80H 60H 00H 01H DATA00
DATA00 : 00H: low
01H: middle
CKS
02H: high
03H: middle low
ACK
7FH 60H 80H 00H 01H DATA00
DATA00 : 00H: low
01H: middle
CKS
02H: high
03H: middle low
14. RED Gain Data
Function
The external control equipment changes the RED Gain Data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : RED Gain Flag
DATA02 : RED Low
01H
01H
D8H : -40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
D8H : -40
:
DATA03: RED High
FFH : -01
00H : 0
01H : +01
:
1EH : +30
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : RED Gain Flag
01H
01H
15
PDP-614MX External Control Manual
15. GREEN Gain Data
Function
The external control equipment changes the GREEN Gain Data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : GREEN Gain Flag
DATA02 : GREEN Low
01H
02H
D8H : -40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
D8H : -40
:
DATA03: GREEN High
FFH : -01
00H : 0
01H : +01
:
1EH : +30
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
DATA01: GREEN Gain Flag
01H
02H
16
PDP-614MX External Control Manual
16. BLUE Gain Data
Function
The external control equipment changes the BLUE Gain Data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : BLUE Gain Flag
DATA02 : BLUE Low
01H
03H
D8H :-40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
D8H :-40
:
DATA03: BLUE High
FFH : -01
00H : 0
01H : +01
:
1EH : +30
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
01H
DATA01: BLUE Gain Flag
03H
17
PDP-614MX External Control Manual
17. DNR MODE Set
Function
The external control equipment sets the NR (Noise Reduction) mode of the plasma monitor.
Transmission Data
DFH 80H 60H C0H 01H DATA00 CKS
DATA00: 01H : OFF
02H : LOW
03H : MID
04H : HIGH
ACK
7FH 60H 80H C0H 01H DATA00 CKS
DATA00: 01H : OFF
02H : LOW
03H : MID
04H : HIGH
18. BASS Gain Data
Function
The external control equipment changes the BASS gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02
CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : BASS Gain Flag
DATA02 : BASS Gain
05H
03H
F3H : -13
:
FFH : -01
00H : 0
01H : +01
:
0DH : +13
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : BASS Gain Flag
05H
03H
18
PDP-614MX External Control Manual
19. TREBLE Gain Data
Function
The external control equipment changes the TREBLE gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : TREBLE Gain Flag
DATA02 : TREBLE Gain
05H
04H
F3H : -13
:
FFH : -01
00H : 0
01H : +01
:
0DH : +13
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
DATA01: TREBLE Gain Flag
05H
04H
20. BALANCE Gain Data
Function
The external control equipment changes the BALANCE gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : BALANCE Gain Flag
DATA02 : BALANCE Gain
05H
02H
EAH : -22
:
FFH : -01
00H : 0
01H : +01
:
16H : +22
ACK
7FH 60H 80H 7FH 02H DATA00
DATA00: USER PICTURE Gain Flag
DATA01: BALANCE Gain Flag
DATA01
CKS
05H
02H
1. SCREEN SIZE Select
Function
The external control equipment switches the screen mode of the plasma monitor.
Transmission Data
DFH 80H 60H 51H 01H DATA00 CKS
DATA00 02H : WIDE
03H : ZOOM
04H : STD
05H : FULL
06H : DOT BY DOT
08H : UNDERSCAN
09H : 14:9
19
PDP-614MX External Control Manual
0AH : 2.35:1
ACK
7FH 60H 80H 51H 01H DATA00
DATA00 02H : WIDE
03H : ZOOM
CKS
04H : STD
05H : FULL
06H : DOT BY DOT
08H : UNDERSCAN
09H : 14:9
0AH : 2.35:1
20
PDP-614MX External Control Manual
22. V.POSITION Gain Data
Function
The external control equipment changes the V. POSITION gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : V.POSITION Gain Flag
DATA02 : V.POSITION Gain
03H
01H
C0H : -64
:
FFH : -01
00H : 0
01H : +01
:
40H : +64
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
DATA01: V.POSITION Gain Flag
03H
01H
21
PDP-614MX External Control Manual
23. H.POSITION Gain Data
Function
The external control equipment changes the H. POSITION gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : H.POSITION Gain Flag
DATA02 : H.POSITION Gain
03H
02H
80H : -128
:
FFH : -01
00H : 0
01H : +01
:
7FH : +127
ACK
7FH 60H 80H 7FH 02H DATA00
DATA00: USER PICTURE Gain Flag
DATA01: H.POSITION Gain Flag
DATA01
03H
02H
CKS
24. V.SIZE Gain Data
Function
The external control equipment changes the V.SIZE gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : V.SIZE Gain Flag
DATA02 : V.SIZE Gain
03H
07H
00H : 0
:
40H : +64
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
DATA01: V.SIZE Gain Flag
03H
07H
22
PDP-614MX External Control Manual
25. H.SIZE Gain Data
Function
The external control equipment changes the H.SIZE gain data of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : H.SIZE Gain Flag
DATA02 : H.SIZE Gain
03H
08H
00H : 0
:
40H : +64
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
DATA01: H.SIZE Gain Flag
03H
08H
26. AUTO PICTURE Select
Function
The external control equipment switches on or off the AUTO PICTURE of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00
DATA00 : USER PICTURE Gain Flag
DATA01 : AUTO PICTURE Select Flag
DATA02 00H : ON
DATA01 DATA02 CKS
03H
09H
01H : OFF
ACK
7FH 60H 80H 7FH 03H DATA00
DATA00 : USER PICTURE Gain Flag
DATA01 : AUTO PICTURE Select Flag
DATA02 00H : ON
DATA01 DATA02 CKS
03H
09H
01H : OFF
23
PDP-614MX External Control Manual
27. PHASE Gain Data
Function
The external control equipment changes the PHASE gain data (Phase) of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : PHASE Gain Flag
DATA02 : PHASE Gain
03H
03H
00H : 0
:
40H : +64 :
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
DATA01: PHASE Gain Flag
03H
03H
28. CLOCK Gain Data
Function
The external control equipment changes the CLOCK gain data (ratio of frequency division) of the plasma monitor.
Transmission Data
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag
DATA01 : CLOCK Gain Flag
DATA02 : CLOCK Gain
03H
04H
C0H : -64
:
FFH : -01
00H : 0
01H : +01
:
40H : +64
ACK
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS
DATA00: USER PICTURE Gain Flag
DATA01: CLOCK Gain Flag
03H
04H
24
PDP-614MX External Control Manual
29. OSM ADJ. POSITION Data
Function
The external control equipment sets the position of the OSM menu of the plasma monitor.
Transmission Data
DFH 80H 60H 1AH 02H DATA00 DATA01 CKS
DATA00 : OSM ADJ. Gain Flag
02H
DATA01
01H : 1(TOP LEFT)
02H : 2(TOP CENTER)
03H : 3(TOP RIGHT)
04H : 4(BOTTOM LEFT)
05H : 5(BOTTOM CENTER)
06H : 6(BOTTOM RIGHT)
ACK
7FH 60H 80H 1AH 01H DATA00 CKS
DATA00 : OSM ADJ. Gain Flag 02H
30. POWER MGT Select
Function
The external control equipment switches on or off the POWER MANAGEMENT of the plasma monitor.
Transmission Data
DFH 80H 60H 1AH 02H DATA00
DATA01 CKS
DATA00 : POWER MGT Select
03H
DATA01
01H : ON
02H : OFF
ACK
7FH 60H 80H 1AH 02H DATA00
DATA01 CKS
DATA00 : POWER MGT Select
03H
DATA01
01H : ON
02H : OFF
31. SIDE MASK Set
Function
The external control equipment sets the SIDE MASK of the plasma monitor.
Transmission Data
DFH 80H 60H C6H 01H DATA00 CKS
DATA00 : SIDE MASK
00H : 0
:
0FH : 15
ACK
7FH 60H 80H C6H 01H DATA00 CKS
DATA00 : SIDE MASK
00H : 0
:
0FH : 15
32. PURECINEMA Set
25
PDP-614MX External Control Manual
Function
The external control equipment switches on or off the PURECINEMA of the plasma monitor.
Transmission Data
DFH 80H 60H C1H 01H DATA00
CKS
DATA00 : PURECINEMA Set
01H : ON
02H : OFF
ACK
7FH 60H 80H C1H 01H DATA00
CKS
DATA00 : PURECINEMA Set
01H : ON
02H : OFF
26
PDP-614MX External Control Manual
33. LONG LIFE Set
Function
The external control equipment sets the PLE, ORBITER, and INVERSE (inverse of image brightness) or WHITE of the
plasma monitor.
Transmission Data
DFH 80H 60H 6BH 03H DATA00 DATA01 DATA02 CKS
DATA00 : PLE
01H : AUTO
02H : LOCK1
03H : LOCK2
04H : LOCK3
01H : INVERSE
02H : OFF
DATA01 : INVERSE/WHITE
DATA02 : ORBITER
03H :WHITE
01H : AUTO1
02H : OFF
03H : AUTO2
ACK
The plasma monitor returns the following ACK when setting the PLE, ORBITER, and INVERSE (inverse of image brightness)
or WHITE:
3FH 60H 80H 6BH 00H CKS
27
PDP-614MX External Control Manual
34. SCREEN WIPER Set
Function
2001.7.10
INVERSE
Set
The external control equipment sets the SCREEN WIPER of the plasma monitor.
Transmission Data
コマンド追加
DFH 80H 60H C8H 04H DATA00 to DATA03 CKS
DATA00 : SCREEN WIPER
00H : No operation
01H : ON
02H : OFF
DATA01 :
DATA02 :
DATA03 :
00H : fixed
FFH: fixed
01H : fixed
ACK
3FH 60H 80H C8H 00H CKS
35. ALL RESET
Function
The external control equipment resets the user adjustment of the plasma monitor.
Transmission Data
1FH 80H 60H 54H 00H CKS
ACK
3FH 60H 80H 54H 00H CKS
28
PDP-614MX External Control Manual
36. Audio Select Set
Function
The external control equipment sets combinations of audio and video inputs for the plasma monitor.
Transmission Data
DFH 80H 60H 70H 02H DATA00 DATA01 CKS
DATA00 : AUDIO INPUT
01H : AUDIO1
02H : AUDIO2
03H : AUDIO3
DATA01 : VISUAL INPUT
01H : VIDEO1
02H : VIDEO2
03H : VIDEO3
05H : COMPNT1
06H : COMPNT2
07H : PC1DSUB
08H : PC2-BNC
0CH : PC3-DVI
ACK
The plasma monitor returns the following ACK when the input is switched.
3FH 60H 80H 70H 00H CKS
* The plasma monitor returns “Not Available” when selecting the video input same as the one set at one of the AUDIO 1 to 3.
Example:
The plasma monitor returns “Not Available” when selecting the VIDEO1 for AUDIO2 or VIDEO3 after VIDEO1 has been set
to AUDIO1.
29
PDP-614MX External Control Manual
37. BNC INPUT
Function
The external control equipment sets the BNC SELECT of the plasma monitor.
Transmission Data
DFH 80H 60H 8CH 01H DATA00 CKS
DATA00 : BNC SELECT
01H : RGB
02H : Component
ACK
The plasma monitor returns the following ACK when setting the BNC SELECT:
7FH 60H 80H 8CH 01H DATA00 CKS
DATA00 : BNC SELECT
01H : RGB
02H : Component
38. RGB Select
Function
The external control equipment sets the RGB SELECT of the plasma monitor.
Transmission Data
DFH 80H 60H 8BH 01H DATA00 CKS
DATA00
01H : AUTO
02H : STILL
03H : MOTION
04H : WIDE1
05H : WIDE2
06H : DTV
07H : WIDE3
08H : WIDE4
ACK
7FH 60H 80H 8BH 01H DATA00 CKS
DATA00
01H : AUTO
02H : STILL
03H : MOTION
04H : WIDE1
05H : WIDE2
06H : DTV
07H : WIDE3
08H : WIDE4
39. HD Select
Function
The external control equipment sets the HD SELECT of the plasma monitor.
Transmission Data
DFH 80H 60H 8AH 01H DATA00 CKS
DATA00
01H : 1035I
02H : 1080A
03H : 1080B
ACK
7FH 60H 80H 8AH 01H DATA00 CKS
DATA00
01H : 1035I
02H : 1080A
03H : 1080B
30
PDP-614MX External Control Manual
40. LANGUAGE Select
Function
The external control equipment sets the LANGUAGE SELECT of the plasma monitor.
Transmission Data
DFH 80H 60H 5BH 01H DATA00 CKS
DATA00: 01H : ENGLISH
02H : GERMAN
03H : FRENCH
04H : SPANISH
05H : ITALIAN
06H : SWEDISH
07H : JAPANESE
0AH : CHINESE
ACK
7FH 60H 80H 5BH 01H DATA00 CKS
DATA00: 01H : ENGLISH
02H : GERMAN
03H : FRENCH
04H : SPANISH
05H : ITALIAN
06H : SWEDISH
07H : JAPANESE
0AH : CHINESE
41. COLOR SYSTEM Select
Function
The external control equipment sets the COLOR SYSTEM of the plasma monitor.
Transmission Data
DFH 80H 60H 5CH 01H DATA00 CKS
DATA00: 01H : 3.58NTSC
02H : 4.43NTSC
03H : PAL
04H : SECAM
0AH : AUTO
0BH : PAL60
0DH : PAL-M
0EH : PAL-N
ACK
7FH 60H 80H 5CH 01H DATA00 CKS
DATA00: 01H : 3.58NTSC
02H : 4.43NTSC
03H : PAL
04H : SECAM
0AH : AUTO
0BH : PAL60
0DH : PAL-M
0EH : PAL-N
31
PDP-614MX External Control Manual
42. FREQUENCY Request(SIGNAL INFORMATION)
Function
The external control equipment inquires the Horizontal frequency, Vertical frequency, Horizontal sync polarity, Vertical sync
polarity, Mode, and Resolution of the plasma monitor.
Transmission Data
1FH 80H 60H 26H 00H CKS
ACK
7FH 60H 80H 26H 0BH DATA00 to DATA0A CKS
Horizontal frequency
DATA00: Integer part
00H: 0 (No signal: 00H)
:
FFH
:
255
DATA01: One decimal place 00H: 0 (No signal: 00H)
:
09H : 9
Vertical frequency
DATA02: Integer part
00H: 0 (No signal: 00H)
:
FFH
:
255
DATA03: One decimal place 00H: 0 (No signal: 00H)
:
09H
:
9
Horizontal sync polarity
DATA04
00H
:
-
01H : Positive
02H : Negative
Vertical sync polarity
DATA05
00H
:
-
01H : Positive
02H : Negative
32
PDP-614MX External Control Manual
MODE
DATA06
00H
: No signal
-
01H to 80H : RGB signal
Identification number of PC mode
81H
82H
83H
84H
85H
86H
87H
88H
89H
A0H
A1H
A2H
A3H
A4H
A5H
A6H
: Video signal 3.58NTSC
:
:
:
:
:
:
:
:
4.43NTSC
PAL
PAL-M
PAL-N
PAL60
SECAM
B/W60
B/W50
: HD/DVD/DTV signal
480I
:
:
:
:
:
:
480P
576I
576P
720P
1035I
1080I
RESOLUTION
DATA07: Dots (Low-order byte) 00H: 0 (No signal: 00H)
:
FFH 255
DATA08: Dots (High-order byte) 00H: 257 (No signal: 00H)
:
FFH
DATA09: Lines (Low-order byte) 00H: 0 (No signal: 00H)
:
FFH 255
DATA10: Lines (High-order byte) 00H: 257 (No signal: 00H)
:
FFH
33
PDP-614MX External Control Manual
43. Input MODE Request
Function
The display returns the current input information by the external control equipment’ s request.
Transmission Data
1FH 80H 60H 41H 00H CKS
ACK
7FH 60H 80H 41H 01H DATA00 CKS
DATA00 : Input Select
01H : Video
02H : Video2
03H : Video3
04H : COMPNT1
05H : PC1DSUB
06H : PC2-BNC
0CH : COMPNT2
0EH : PC3-DVI
44. VIDEO ADJ. Request
Function
The display returns the video adjustments information by the external control equipment’s request.
Transmission Data
1FH 80H 60H 45H 00H CKS
ACK
7FH 60H 80H 45H 0CH DATA00 to DATA0B CKS
DATA00: RED Gain (Low)
DATA01: GREEN Gain (Low)
DATA02: BLUE Gain (Low)
DATA03: COLOR Gain
D8H : -40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
D8H : -40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
D8H : -40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
E0H : -32
:
* COLOR Gain is from -22 (EAH) to FFH : -01
+22 (16H) only during video.
00H : 0
01H : +01
:
20H : +32
34
PDP-614MX External Control Manual
DATA04: TINT Gain
E0H : -32
:
* TINT Gain is from -22 (EAH) to
+22 (16H) only during video.
FFH : -01
00H : 0
01H : +01
:
20H : +32
DATA05: SHARPNESS Gain
DATA06: CONTRAST Gain
DATA07: BRIGHT Gain
F0H : -16
:
FFH : -01
00H : 0
01H : +01
:
10H : +16
CCH : -52
:
FFH : -01
00H : 0
01H : +01
:
14H : +20
E0H : -32
:
FFH : -01
00H : 0
01H : +01
:
20H : +32
DATA08: RED Gain (High)
DATA09: GREEN Gain (High)
DATA0A: BLUE Gain (High)
D8H : -40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
D8H : -40
:
FFH : -01
00H : 0
01H : +01
:
1EH : +30
D8H : -40
:
FFH : -01
00H : 0
35
PDP-614MX External Control Manual
01H : +01
:
1EH : +30
DATA0B: COLOR TEMP SELECT 00H: low
01H: middle
02H: high
03H: middle low
45. Audio Select Request
Function
The external control equipment inquires the current combinations of audio and video inputs for the plasma monitor.
Transmission Data
1FH 80H 60H 6FH 00H CKS
ACK
The plasma monitor returns the following ACK:
7FH 60H 80H 6FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : AUDIO1
01H-0CH : VISUAL INPUT DATA
DATA01 : AUDIO2
01H-0CH : VISUAL INPUT DATA
DATA02 : AUDIO3
01H-0CH : VISUAL INPUT DATA
<VISUAL INPUT DATA>
01H : VIDEO1
02H : VIDEO2
03H : VIDEO3
05H : COMPNT1
06H : COMPNT2
07H : PC1DSUB
08H : PC2-BNC
0CH : PC3-DVI
36
PDP-614MX External Control Manual
46. Failure Mode Request
Function
The external control equipment inquires the detection of failures of the plasma monitor.
Transmission Data
1FH 80H 60H 3FH 00H CKS
ACK
The plasma monitor returns the following ACK:
7FH 60H 80H 3FH 02H DATA00 DATA01 CKS
DATA00: FAILURE MODE 1
Bit 0 : PDP MODULE
0: Abnormal
1: Normal
Bit 1 : 1: fixed (backup)
Bit 2 : TEMPERATURE
0: Abnormal
1: Normal
Bit 3 : FAN
0: Abnormal
1: Normal
Bit 4 : TEMPERATURE SENSOR
0: Abnormal
1: Normal
Bit 5 : 1: fixed (backup)
Bit 6 : 1: fixed (backup)
Bit 7 : 1: fixed (backup)
DATA01: FAILURE MODE 2
Bit 0-7 : 1: fixed (backup)
37
PDP-614MX External Control Manual
47. MODEL NAME Request
Function
The external control equipment inquires the product code of the plasma monitor.
Transmission Data
1FH 80H 60H 17H 00H CKS
ACK
The plasma monitor returns the following ACK:
7FH 60H 80H 17H 0CH DATA00 to DATA11 CKS
DATA00 : 1st character of the product code
DATA01 : 2nd character of the product code
:
DATA11 : 12th character of the product code
Received data
00H-09H : 0-9
80H
81H
82H
83H
84H
85H
86H
87H
96H
:
:
:
:
:
:
:
:
- (Hyphen)
+
/
(
)
.
‘
:
Blank
10H-29H
: A-Z
Corresponding
character
A
B
C
D
E
F
G
H
I
J
Received data (H) 10 11 12 13 14 15 16 17 18 19
Corresponding
character
K
L
M
N
O
P
Q
R
S
T
Received data (H) 1A 1B 1C 1D 1E 1F 20 21 22 23
Corresponding
character
U
V
W
X
Y
Z
Received data (H) 24 25 26 27 28 29
If there are fewer than 12 characters in the product code, product code would be padded right with blanks.
Example: If the product code of your plasma monitor is “50XGA”, the returned codes would be as follows.
DATA00:05H, DATA01:00H, DATA02:27H, DATA03:16H, DATA04:10H, DATA05:96H, DATA06:96H, DATA07:96H,
DATA08:96H, DATA09:96H, DATA10:96H, DATA11:96H
38
PDP-614MX External Control Manual
48.LOW TONE
Function
The external control equipment sets the dithering processing or error diffusion processing of the plasma monitor.
Transmission Data
DFH 80H 60H 0CH 01H DATA00 CKS
DATA00:
00H:AUTO
01H: dithering processing(for motion picture)
02H: dithering processing (for still picture)
03H: error diffusion processing
ACK
7FH 60H 80H 0CH 01H DATA00 CKS
DATA00:
00H:AUTO
01H: dithering processing
02H: dithering processing
03H: error diffusion processing
39
PDP-614MX External Control Manual
49. C.DETAIL ADJ
Function
External control equipment can adjust RGB each color which a plasma monitor wants to emphasize.
Transmission Data
DFH 80H 60H 0DH 07H DATA00 to DATA06 CKS
DATA00:RED
00H : -32
:
20H : 0
:
40H : +32
DATA01:GREEN
DATA02:BLUE
DATA03:YELLOW
DATA04:MAZENTA
DATA05:CYAN
DATA06:RESET
00H : -32
:
20H : 0
:
40H : +32
00H : -32
:
20H : 0
:
40H : +32
00H : -32
:
20H : 0
:
40H : +32
00H : -32
:
20H : 0
:
40H : +32
00H : -32
:
20H : 0
:
40H : +32
00H : OFF
01H : ON
ACK
7FH 60H 80H 0DH 00H CKS
50.GAMMA GAIN Data
Function
External control apparatus changes Gamma of a plasma monitor.
Transmission Data
DFH 80H 60H 13H 02H DATA00 DATA01 CKS
DATA00: GAMMA FLAG
01H : Gamma change
00H :1(GAMMA2.1)
01H :2(GAMMA2.2)
02H :3(GAMMA2.3)
03H :4(GAMMA2.4)
DATA01: GAMMA
40
PDP-614MX External Control Manual
ACK
7FH 60H 80H 13H 01H DATA00 CKS
DATA00: GAMMA FLAG 01H : Gamma change
41
PDP-614MX External Control Manual
51.Running Sense
Function
External control apparatus grasps the power supply state of a plasma monitor.
A plasma monitor is made to recognize connection of PC CONTROL.
Transmission Data
1FH 80H 60H 88H 00H CKS
ACK
7FH 60H 80H 88H 01H DATA CKS
DATA: Bit0:Connect Condition
0: No connection
1: Connected
Bit1 0: Fixed
1:-
Bit2:Power Status
0:POWER ON
1:POWER OFF(STANBY)
Bit3 0: Fixed
Bit4 0: Fixed
Bit5 0: Fixed
Bit6 0: Fixed
Bit7 0: Fixed
42
PDP-614MX External Control Manual
52. OSM OBITER
Function
In order to decrease printing of a screen by OSM display, whenever it displays OSM, shift operation of the OSM is carried out.
Transmission Data
DFH 80H 60H 5FH 01H DATA00
CKS
DATA00
ACK
01H : OBITER ON
02H : OBITER OFF
7FH 60H 80H 5FH 01H DATA00
CKS
DATA00
01H : OBITER ON
02H : OBITER OFF
53. Input Skip
Function
In a monitor's key "an input change", when there is no signal, it flies and shifts to the following channel.
Transmission Data
DFH 80H 60H 61H 01H DATA00
CKS
DATA00
ACK
01H : ON
02H : OFF
7FH 60H 80H 61H 01H DATA00
CKS
DATA00
01H : ON
02H : OFF
43
PDP-614MX External Control Manual
54. SERIAL No. Request
Function
External control apparatus read the serial number of the set recorded by EEPROM of a plasma display.
Transmission Data
1FH 80H 60H 15H 00H CKS
ACK
7FH 60H 80H 15H 0CH DATA00 to DATA11 CKS
Even DATA00-DATA11 is set up as follows.
Setting value
00H-09H
96H
:
:
0 - 9
Blank
10H-29H
:
A-Z of Alphabet
55.S1/S2 SELECT
Function
External control apparatus sets up the S1/S2 detection of a plasma monitor.
Transmission Data
DFH 80H 60H 89H 01H DATA00 CKS
DATA00
01H : AUTO
02H : OFF
ACK
7FH 60H 80H 89H 01H DATA00 CKS
DATA00
01H : AUTO
02H : OFF
44
PDP-614MX External Control Manual
56.SOFT FOCUS
Function
External control apparatus sets up the Soft Focus of a plasma monitor.
Transmission Data
DFH 80H 60H 65H 01H DATA00 CKS
DATA00 01H : OFF
02H : LEVEL1
03H : LEVEL2
04H : LEVEL3
05H : LEVEL4
ACK
7FH 60H 80H 65H 01H DATA00 CKS
DATA00 01H : OFF
02H : LEVEL1
03H : LEVEL2
04H : LEVEL3
05H : LEVEL4
57.PLUG and PLAY
Function
External control apparatus sets up the Plug and Play of a plasma monitor.
Transmission Data
DFH 80H 60H 8EH 01H DATA00 CKS
DATA00 01H : PC
02H : STB/DVD(HDCP signal)
ACK
7FH 60H 80H 8EH 01H DATA00 CKS
DATA00 01H : PC
02H : STB/DVD(HDCP signal)
45
PDP-614MX External Control Manual
58.BLACK LEVEL SELECT
Function
External control apparatus sets up the black level (digital signal level) of a plasma monitor.
Transmission Data
DFH 80H 60H 8FH 01H DATA00 CKS
DATA00 01H : LOW
02H : HIGH
ACK
7FH 60H 80H 8FH 01H DATA00 CKS
DATA00 01H : LOW
02H : HIGH
59.OSM CONTRAST SELECT
Function
External control apparatus selects the OSM contrast function of a plasma monitor.
Transmission Data
DFH 80H 60H 37H 01H DATA00 CKS
DATA00 01H : NORMAL
02H : LOW
ACK
7FH 60H 80H 37H 01H DATA00 CKS
DATA00 01H : NORMAL
02H : LOW
.60.OSM Select
Function
The external control equipment switches on or off the on-screen menu (OSM) of the plasma monitor.
Transmission Data
DFH 80H 60H 58H 01H DATA00 CKS
DATA00:
01H: On-Screen menu On
02H: On-Screen menu Off
ACK
7FH 60H 80H 58H 01H DATA00 CKS
DATA00:
01H: On-Screen menu On
02H: On-Screen menu Off
*Operation is as described in the table below.
On-Screen Menu (OSM)
Display of items and adjustments
on the menu
Volume display, input display, and
screen size display
Operation
When
screen When
screen When
screen When
screen
menu is ON
menu is OFF
menu is ON
menu is OFF
46
PDP-614MX External Control Manual
Remote
control
operation
Personal
computer
control
Yes
No
Yes
Yes
No
No
Yes
No
operation
61. INVERSE Set
Function
2001.7.10
INVERSE
Set
The external control equipment sets the INVERSE (inverse of image brightness) and the WHITE of the plasm
Transmission Data
コマンド追加
DFH 80H 60H C7H 03H DATA00 DATA01 DATA02 CKS
DATA00: INVERSE/WHITE
00H : No operation
01H : ON (INVERSE)
02H : OFF
03H : WHITE
DATA01 : WORKING TIME
00H : ON
01H: 03M (minutes)
02H: 06M (minutes)
:
FFH: 12H (hours) and 45M (minutes)
01H: 03M (minutes)
02H: 06M (minutes)
:
DATA02 : WAITING TIME
FFH: 12H (hours) and 45M (minutes)
ACK
3FH 60H 80H C7H 00H CKS
NOTE: The WORKING TIME and the WAITING TIME can be set in
units of 3 minutes.
Example: 03H=9 minutes
1EH=1 hour and 30 minutes
47
PDP-614MX External Control Manual
62. TIMER SWITCH
Function
The external control equipment sets the timer reservation of the plasma monitor.
Transmission Data
DFH 80H 60H 02H 01H DATA00 CKS
DATA00:
00H : Reservation OFF
01H : Reservation ON
ACK
7FH 60H 80H 02H 01H DATA00 CKS
DATA00:
00H : Reservation OFF
01H : Reservation ON
63. TIMER PROGRAM SETTING
Function
External control apparatus sets up the timer program of a plasma monitor.
Transmission Data
DFH 80H 60H 30H 08H DATA00 to DATA07 CKS
DATA00 PROGRAM No
01H~07H
DATA01 DATE
01H~07H
08H
:No1~No7
: Sunday - Saturday
: Every day
09H~0FH
: Every week Sunday - every week Saturday
FFH : - (with No Setup)
DATA02 ON time (HOUR)
00H~09H
10H~19H
20H~23H
:00~09
:10~19
:20~23
FFH : - (with No Setup)
DATA03 ON time (MIN)
00H~09H
10H~19H
20H~29H
30H~39H
40H~49H
50H~59H
:00~09
:10~19
:20~29
:30~39
:40~49
:50~59
FFH : - (with No Setup)
DATA04 OFF time (HOUR)
00H~09H
10H~19H
20H~23H
:00~09
:10~19
:20~23
FFH : - (with No Setup)
DATA05 OFF time(MIN)
00H~09H
10H~19H
20H~29H
30H~39H
40H~49H
50H~59H
:00~09
:10~19
:20~29
:30~39
:40~49
:50~59
FFH : - (with No Setup)
48
PDP-614MX External Control Manual
DATA06 INPUT
01H
02H
: Video1
: Video2
03H
: Video3
04H
: COMPNT1
: COMPNT2
: PC1DSUB
: PC2-BNC
: PC3-DVI
05H
06H
07H
08H
FFH
: - (with No Setup)
DATA07 MODE
01H
: OBIT
: INV
02H
03H
: WT
04H
: WIPER
FFH : - (with No Setup)
ACK
7FH 60H 80H 30H 00H CKS
64. PRESENT TIME SETTING
Function
External control apparatus sets up the present time of a plasma monitor.
Transmission Data
DFH 80H 60H 31H 03H DATA00 to DATA02 CKS
DATA00 Day of the week 01H-07H : 1-7 (Sunday - Saturday)
DATA01 HOUR
DATA02 minutes
00H-09H:00-09
10H~19H:10~19
20H~23H:20~23
00H-09H:00-09
10H~19H:10~19
20H~29H:20~29
30H~39H:30~39
40H~49H:40~49
50H~59H:50~59
ACK
7FH 60H 80H 31H 00H CKS
65. MULTI MODE Select
Function
External control apparatus changes MULTI MODE of a plasma monitor.
Transmission Data
DFH 80H 60H 03H 03H DATA00 DATA01 DATA02 CKS
DATA00 (SCREEN DIVIDER SETTING)
01H : Single mode
02H : Multi mode 1 screens
03H : Multi mode 4 screens
04H : Multi mode 9 screens
05H : Multi mode 16 screens
06H : Multi mode 25 screens
49
PDP-614MX External Control Manual
DATA01 (POSITION OF DIVIDE)
01H : Upper left selected (4 screens)
02H : Upper right selected (4 screens)
03H : Lower right selected (4 screens)
04H : Lower left selected (4 screens)
07H : Top left selected (9 screens)
08H : Top middle selected (9 screens)
09H : Top right selected (9 screens)
0AH : Middle left selected (9 screens)
0BH : Middle centerselected (9 screens)
0CH : Middle rightselected (9 screens)
0DH : Bottom leftselected (9 screens)
0EH : Bottom middle selected (9 screens)
0FH : Bottom right selected (9 screens)
10H : position1(16 screens,refer to figure1)
11H : position2(16 screens,refer to figure1)
:
18H : position9(16 screens,refer to figure1)
19H : position10(16 screens,refer to figure1)
:
1FH : position16 (16 screens,refer to figure1)
20H : position1(25 screens,refer to figure2)
21H : position2(25 screens,refer to figure2)
:
29H : position10(25 screens,refer to figure2)
2AH : position11(25 screens,refer to figure2)
:
32H : position19(25 screens,refer to figure2)
33H : position20(25 screens,refer to figure2)
:
38H : position25(25 screens,refer to figure2)
1
6
2
7
3
8
4
9
5
1
6
2
7
3
8
4
10
15
9
11
16
21
12
17
22
13
18
23
14
11
16
12
17
13
18
14
19
19 20
24 25
Figure1
Figure2
DATA02 (DISP MODE)
00H : SPLIT
01H : BRANKING
ACK
7FH 60H 80H 03H 03H DATA00 DATA01 DATA02 CKS
DATA00 (SCREEN DIVIDER SETTING)
01H : Single mode
02H : Multi mode 1 screens
03H : Multi mode 4 screens
04H : Multi mode 9 screens
50
PDP-614MX External Control Manual
05H : Multi mode 16 screens
06H : Multi mode 25 screens
DATA01 (POSITION OF DIVIDE)
01H : Upper left selected (4 screens)
02H : Upper right selected (4 screens)
03H : Lower right selected (4 screens)
04H : Lower left selected (4 screens)
07H : Top left selected (9 screens)
08H : Top middle selected (9 screens)
09H : Top right selected (9 screens)
0AH : Middle left selected (9 screens)
0BH : Middle centerselected (9 screens)
0CH : Middle rightselected (9 screens)
0DH : Bottom leftselected (9 screens)
0EH : Bottom middle selected (9 screens)
0FH : Bottom right selected (9 screens)
10H : position1(16 screens,refer to figure1)
11H : position2(16 screens,refer to figure1)
:
18H : position9(16 screens,refer to figure1)
19H : position10(16 screens,refer to figure1)
:
1FH : position16 (16 screens,refer to figure1)
20H : position1(25 screens,refer to figure2)
21H : position2(25 screens,refer to figure2)
:
29H : position10(25 screens,refer to figure2)
2AH : position11(25 screens,refer to figure2)
:
32H : position19(25 screens,refer to figure2)
33H : position20(25 screens,refer to figure2)
:
38H : position25(25 screens,refer to figure2)
1
6
2
7
3
8
4
9
5
1
6
2
7
3
8
4
10
15
9
11
16
21
12
17
22
13
18
23
14
11
16
12
17
13
18
14
19
19 20
24 25
Figure1
Figure2
DATA02 (DISP MODE)
00H : SPLIT
01H : BRANKING
66. MULTI MODE Request
Function
External control apparatus can know the MULTI MODE information on a plasma monitor.
51
PDP-614MX External Control Manual
Transmission Data
1FH 80H 60H 3BH 00H CKS
ACK
7FH 80H 60H 3BH 02H DATA00 DATA01 DATA02 CKS
DATA00 (SCREEN DIVIDER SETTING)
01H : Single mode
02H : Multi mode 1 screens
03H : Multi mode 4 screens
04H : Multi mode 9 screens
05H : Multi mode 16 screens
06H : Multi mode 25 screens
DATA01 (POSITION OF DIVIDE)
01H : Upper left selected (4 screens)
02H : Upper right selected (4 screens)
03H : Lower right selected (4 screens)
04H : Lower left selected (4 screens)
07H : Top left selected (9 screens)
08H : Top middle selected (9 screens)
09H : Top right selected (9 screens)
0AH : Middle left selected (9 screens)
0BH : Middle centerselected (9 screens)
0CH : Middle rightselected (9 screens)
0DH : Bottom leftselected (9 screens)
0EH : Bottom middle selected (9 screens)
0FH : Bottom right selected (9 screens)
10H : position1(16 screens,refer to figure1)
11H : position2(16 screens,refer to figure1)
:
18H : position9(16 screens,refer to figure1)
19H : position10(16 screens,refer to figure1)
:
1FH : position16 (16 screens,refer to figure1)
20H : position1(25 screens,refer to figure2)
21H : position2(25 screens,refer to figure2)
:
29H : position10(25 screens,refer to figure2)
2AH : position11(25 screens,refer to figure2)
:
32H : position19(25 screens,refer to figure2)
33H : position20(25 screens,refer to figure2)
:
38H : position25(25 screens,refer to figure2)
1
6
2
7
3
8
4
9
5
1
6
2
7
3
8
4
10
15
9
11
16
21
12
17
22
13
18
23
14
11
16
12
17
13
18
14
19
19 20
24 25
Figure1
Figure2
52
PDP-614MX External Control Manual
DATA02 (DISP MODE)
00H : SPLIT
01H : BRANKING
53
PDP-614MX External Control Manual
67. AUTO ID SET START
Function
External control apparatus sets up ID automatically to two or more plasma monitors.
Transmission Data
5FH 80H 60H F0H 01H DATA00 CKS
DATA00
00H~FFH: ID of a master*1 is set up.
*: When you use it by the multi-system, please remove the link input of a master*1.
*1: “Master” means the 1st set of PDP at the time of cable connection at the time of AUTO ID execution.
68. PLE LINK
Function
External control apparatus sets up equally PLE between two or more plasma monitors.
Transmission Data
DFH 80H 60H F1H 03H DATA00 to DATA02 CKS
DATA00 00H:PLE LINK ON
01H:PLE LINK OFF
DATA01 FFH(fixed)
DATA02 FFH(fixed)
*:Turn on the AUTO ID and set the DIVIDER(at 1,4 or 9), before this operation
69. VIDEO WALL SETTING
Function
External control apparatus sets 4screens or 9screens as a video wall.
Transmission Data
DFH 80H 60H F3H 03H DATA00 DATA01 DATA02 CKS
DATA00:
01H:1 screen
(Matrix diplay function does not work.)
04H:4 screens (2*2 video wall)
09H:9 screens (3*3 video wall)
00H(fixed)
DATA 01:
DATA 02:
01H : Video1
02H : Video2
03H : Video3
04H : COMPNT1
05H : COMPNT2
06H : COMPNT3
07H : PC1DSUB
08H : PC2-BNC
09H : PC3-DVI
*:Turn on the AUTO ID, before this operation
*: This command is used to following system.
1. The system configuration is video wall system (4screens or 9screens).
Then please connect each PDP by wired cable.
In the case of 16 screens or 25 screens video wall system, please refer to No.65.”MULTI MODE Select”.
2. The ID number from a master display is set the continuous number.
54
PDP-614MX External Control Manual
55
PDP-614MX External Control Manual
70. POWER DELAY ON(at 4 or 9 multiscreen)
Function
External control apparatus attaches a time lag to two or more plasma monitors, and turns on a power supply.
Transmission Data
DFH 80H 60H F2H 01H DATA00 CKS
DATA00: 00H-FFH: Delay time (second)
*:Turn on the AUTO ID and set the DIVIDER(at 4 or 9), before this operation
*: This command is premised on two or more plasma monitor system composition being multi-systems. In command issue of
master1 OSD operation, the value of DATA00 is 01H (1 second). This command does not have ACK for one-way traffic.
*1: “Master” means the 1st set of PDP at the time of cable connection at the time of AUTO ID execution.
71. POWER DELAY ON (at 16 or 25 multi screens)
Function
External control apparatus attaches a time lag to 10 or more plasma monitors, and turns on a power supply.
Transmission Data
DFH 80H 60H F6H 01H DATA00 CKS
DATA00: 01H
02H
mode1
mode2
ACK
7FH 60H 80H F6H 01H DATA00 CKS
DATA00: 01H
02H
mode1
mode2
NOTE: When multi mode is 16 or 25, this function is available.
56
PDP-614MX External Control Manual
72. ORBITER SET
Function
A picture shift function is set up.
Transmission Data
DFH 80H 60H 1EH 04H DATA00 to DATA03 CKS
DATA00: Mode
00H : OFF
01H : Auto 1
02H : Auto 2
03H : Manual
DATA01: The horizontal amount of movements
1 dot : 01H
to
: -
20 dot : 14H
DATA02: The vertical amount of movements
One line : 01H
to
: -
20 line : 14H
DATA03: Interval of operation 1 - 5 minutes : 01H - 05H
ACK
7FH 60H 80H 1EH 01H DATA00 CKS
DATA00: Mode
00H : OFF
01H : Auto 1
02H : Auto 2
03H : Manual
* DATA01-03
Auto1,2 setting : 01H fixed
Manual setting : Please set DATA 01-03.
73. OSM ANGLE
Function
The vertical display of OSM and a horizontal display are chosen.
Transmission Data
DFH 80H 60H 60H 01H DATA00
CKS
DATA00
01H : Horizontal display
02H : Vertical display
ACK
7FH 60H 80H 60H 01H DATA00
CKS
DATA00
01H : Horizontal display
02H : Vertical display
74. PICTURE Size
Function
Screen mode selection.
57
PDP-614MX External Control Manual
Transmission Data
DFH 80H 60H 2AH 01H DATA00
DATA00 01H : ON
CKS
CKS
02H : OFF
ACK
7FH 60H 80H 2AH 01H DATA00
DATA00 01H : ON
02H : OFF
75. OPTION Select
Function
Power-on mode, a control lock, and IR remote are set up.
Transmission Data
DFH 80H 60H 63H 04H DATA00 to DATA03 CKS
DATA00 : Power ON mode
00H : LAST
01H : Video1
02H : Video2
03H : Video3
05H : COMPNT1
06H: COMPNT2
07H : PC1DSUB
08H : PC2-BNC
0CH : PC3-DVI
00H : OFF
DATA01 : Control Lock
DATA02 : IR remote
DATA03 : Loop Out
01H : ON
00H : OFF
01H : ON
00H : OFF
01H : ON
ACK
7FH 60H 80H 63H 00H CKS
76. REPEAT Timer
Function
External control apparatus sets up the repeat timer of a plasma monitor.
Transmission Data
DFH 80H 60H 64H 07H DATA00 to DATA06 CKS
DATA00
00H :REPEAT Timer OFF
01H :REPEAT Timer ON
DATA01 PROGRAM 1
01H :DIVIDER 1
02H :DIVIDER 4
03H :DIVIDER 9
DATA02 SOURCE 01H :Video1
02H :Video2
03H :Video3
05H : COMPNT1
06H : COMPNT2
07H : PC1DSUB
08H : PC2-BNC
58
PDP-614MX External Control Manual
0CH : PC3-DVI
DATA03 WORK TIME
01 H-FFH:1 - 255 minutes (1 minute - 4 hours and 15 minutes)
DATA04 PROGRAM 1
01H :DIVIDER 1
02H :DIVIDER 4
03H :DIVIDER 9
DATA05 SOURCE 01H :Video1
02H :Video2
03H :Video3
05H : COMPNT1
06H : COMPNT2
07H : PC1DSUB
08H : PC2-BNC
0CH : PC3-DVI
DATA06 WORK TIME
01 H-FFH:1 - 255 minutes (1 minute - 4 hours and 15 minutes)
ACK
7FH 60H 80H 64H 00H CKS
*:Turn on the AUTO ID, before this operation
59
External Control Manual
RS-232C Configuration
(for PDP-614MX and PDP-424MV)
Pioneer Electronics (USA) Inc.
Industrial Solutions Business Group
2265 East 220th Street
Long Beach, CA 90810
|