Pioneer Flat Panel Television PDP 614MX and PDP 424MV User Manual

External Control Manual  
RS-232C Configuration  
(for PDP-614MX and PDP-424MV)  
Version 1.0  
Dec 2005  
 
PDP-614MX External Control Manual  
2) Connector on the external equipment side: Serial port (RS-232C) connector. See the specifications of the equipment that is  
to be connected for the type of connector and the pin assignment.  
3) Wiring  
Use a crossed (reverse) cable.  
Wire the cable so that each pair of data lines cross between the two devices. These data line pairs are RXD (Receive data)  
and TXD (Transmit data), DTR (DTE side ready) and DSR (DCE side ready), and RTS (Ready to send) and CTS (Clear to  
send).  
Communication Parameters  
(1) Communication system  
(2) Interface  
Asynchronous  
RS-232C  
(3) Baud rate*  
1200/2400/4800/9600(default)/19200/38400bps  
(4) Data length  
(5) Parity  
8 bits  
Non  
1 bit  
(6) Stop bit  
(7) Communication code  
(8) Flow control  
Hex  
Non  
* Selectable in the service menu.  
3
 
PDP-614MX External Control Manual  
Communication Format  
8bit 8bit 8bit 8bit 8bit 8bit  
8bit 8bit  
Command 1  
Unit ID 1  
Unit ID 2  
Command 2  
Data length  
Data  
Check sum  
Command1  
Command 1, along with command 2, is a number used to distinguish each command.  
When making it operate using ID, bit1 and bit0 are set up as follows.  
Bit1,Bit0 Unit ID distinction bit  
11B  
10B  
01B  
00B  
:Usually, a form (with no ID)  
:Usually, a form (with no ID)  
:Set ID  
:Video wall ID  
In the case of ACK, when the lower order 4 bits is FH (as in 3FH and 7FH), this indicates that the commands and  
data of the supported equipment have been received. When the lower order 4 bits is BH (as in 3BH and 7BH),  
this indicates that unsupported commands and data have been received.  
Unit ID1,2 (UA1,UA2)  
Unit ID 1 and unit ID 2 are numbers used to identify the equipment that is to be connected.  
60H is used for the plasma monitor and 80H is used for external control equipment such as a personal computer.  
1)Unit ID 1: Indicates the equipment sending the signal. When supporting Set ID by the command 1, 4 bits of low  
ranks of Set ID are set up.  
2)Unit ID 2: Indicates the equipment receiving the signal. When supporting Set ID by the command 1, 4 bits of  
higher ranks of Set ID are set up.  
* Set ID : it is the apparatus number assigned to each plasma monitor.  
Command 2  
Command 2, along with command 1, is a number used to distinguish each command.  
Check Sum (CKS), Error Processing, and ACK  
1) The check sum described below and RS-232C odd parity are used together for a check of the received data. The check sum is  
4
 
PDP-614MX External Control Manual  
the lower order 8 bits of one frame of sent or received data comprising the sum total of Command 1, Unit ID 1 and 2,  
Command 2, Data Length, and Data.  
Check Sum Example  
DFH  
80H  
60H  
47H  
01H  
01H  
08H  
Command1  
Unit ID1  
Unit ID2  
Command2 Data Length  
Data  
Check Sum  
Total 208H  
2) Error Processing  
• When the communication interval is vacant for more than 4 ms, thereafter a received Command 1 will be recognized. If, at  
this time, meaningful data cannot be recognized, that data will not be recognized (as valid data).  
• An ACK will not be returned unless the receive data error, the check sum error, and the receive data are all taken in.  
5
 
PDP-614MX External Control Manual  
The control method of the set by Set ID  
When controlling two or more sets of plasma monitors, if the command using Set ID is used, it will become controllable  
individually.  
The example of the POWER ON command to the plasma monitor which set ID as "5" is shown below.  
It is not based on ID but is the POWER ON command to all sets.  
9F 80 60 4E 00 CD  
In ID= "5", the value of ID-1=4 is set up.  
9D 84 60 4E 00 CF  
The example of a change in the single mode of a 4th page multi-system configuration and the multi-mode is shown below.  
ID of the set used as a master(etc PC) is set to 50, and it assumes that ID is shaken by AUTO ID to each set. ID shaken at each set is as  
follows.  
Upper left set (master) ID = 50 = 32h  
Upper right set ID = 51 = 33h  
Lower right set ID = 52 = 34h  
Lower left set ID = 53 = 35h  
Transmission Data  
DD 81 63 03 03 03 01 00 CB  
DD 82 63 03 03 03 02 00 CD  
DD 83 63 03 03 03 03 00 CF  
DD 84 63 03 03 03 04 00 D1  
Transmission of the above command performs a 4th page multi SPLIT display.  
Moreover, the following commands are published in order to change a 4th page multi-display into a single mode display.  
DF 80 60 03 03 01 01 00 C7  
All sets become a single mode display by the above-mentioned command.  
Since this command does not specify Set ID, all sets execute it.  
*:Control by ID may not be able to be performed depending on connection with external control apparatus.  
6
 
PDP-614MX External Control Manual  
Command Reference List  
CMD1  
9FH  
9FH  
DFH  
DFH  
9FH  
9FH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
1FH  
DFH  
DFH  
DFH  
DFH  
DFH  
DFH  
1FH  
1FH  
1FH  
1FH  
1FH  
1FH  
DFH  
DFH  
DFH  
1FH  
DFH  
5FH  
1FH  
DFH  
DFH  
DFH  
DFH  
CMD2  
4EH  
4FH  
47H  
7FH  
3EH  
3FH  
7FH  
7FH  
7FH  
7FH  
7FH  
0AH  
00H  
7FH  
7FH  
7FH  
C0H  
7FH  
7FH  
7FH  
51H  
7FH  
7FH  
7FH  
7FH  
7FH  
7FH  
7FH  
1AH  
1AH  
C6H  
C1H  
6BH  
C8H  
54H  
70H  
8CH  
8BH  
8AH  
5BH  
5CH  
26H  
41H  
45H  
6FH  
3FH  
17H  
0CH  
0DH  
13H  
88H  
5FH  
61H  
15H  
89H  
65H  
8EH  
8FH  
LEN  
00H  
00H  
01H  
03H  
00H  
00H  
03H  
03H  
03H  
03H  
03H  
01H  
01H  
04H  
04H  
04H  
01H  
03H  
03H  
03H  
01H  
03H  
03H  
03H  
03H  
03H  
03H  
03H  
02H  
02H  
01H  
01H  
03H  
04H  
00H  
02H  
01H  
01H  
01H  
01H  
01H  
00H  
00H  
00H  
00H  
00H  
00H  
01H  
08H  
04H  
00H  
01H  
01H  
00H  
01H  
01H  
01H  
01H  
01  
02  
03  
04  
05  
06  
07  
08  
09  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
Power ON  
Power OFF  
Input Switch Change  
VOLUME Gain Data  
AUDIO Mute ON  
AUDIO Mute OFF  
CONTRAST Gain Data  
BRIGHT Gain Data  
SHARPNESS Gain Data  
Color Gain Data  
TINT Gain Data  
AV SELECTION Select  
COLOR TEMP SELECT  
RED Gain Data  
GREEN Gain Data  
BLUE Gain Data  
DNR MODE Set  
BASS Gain Data  
TREBLE Gain Data  
BALANCE Gain Data  
SCREEN SIZE Select  
V.POSITION Gain Data  
H.POSITION Gain Data  
V-SIZE Gain Data  
H-SIZE Gain Data  
AUTO PICTURE Select  
PHASE Gain Data  
CLOCK Gain Data  
OSM ADJ. position Data  
POWER MGT Select  
SIDE MASK Set  
PURECINEMA Set  
LONG LIFE Set  
SCREEN WIPER Set  
ALL RESET  
Audio Inut Set  
BNC INPUT  
RGB Select  
HD Select  
LANGUAGE Select  
COLOR SYSTEM Select  
FREQUENCY Request  
Input MODE Request  
VIDEO ADJ Request  
Audio Select Request  
Failure Mode Request  
MODEL NAME Request  
LOW TONE  
C.DETAIL ADJ  
GAMMA Gain Data  
Running Sense  
OSM OBITER  
Input Skip  
SERIAL No. Request  
S1/S2 SELECT  
SOFT FOCUS  
PLUG and PLAY  
BLACK LEVEL  
(DIGITAL SIGNAL LEVEL)  
OSM CONTRAST  
59  
DFH  
37H  
01H  
7
 
PDP-614MX External Control Manual  
29  
35  
51  
54  
OSM Select  
INVESE Set  
TIMER SWITCH  
TIMER  
DFH  
DFH  
DFH  
58H  
C7H  
02H  
30H  
01H  
03H  
01H  
08H  
PROGRAM DFH  
SETTING  
55  
56  
57  
58  
59  
60  
61  
PRESENT TIME SETTING  
MULTI MODE Select  
MULTI MODE Request  
AUTO ID SET START  
PLE LINK  
VIDEO WALL SETTING  
POWER DELAY ON  
(DIVIDER setting : 1/4/9)  
POWER DELAY ON  
(DIVIDER setting : 16/25)  
ORBITTER SET  
DFH  
DFH  
1FH  
5FH  
DFH  
DFH  
DFH  
31H  
03H  
3BH  
F0H  
F1H  
F3H  
F2H  
03H  
03H  
00H  
01H  
03H  
02H  
01H  
62  
DFH  
F6H  
01H  
65  
67  
DFH  
DFH  
DFH  
DFH  
DFH  
1EH  
60H  
2AH  
63H  
64H  
04H  
01H  
01H  
04H  
06H  
OSM ANGLE  
69*1 PICTURE Size  
70  
71  
OPTION Select  
REPEAT Timer  
8
 
PDP-614MX External Control Manual  
01. Power ON  
Function  
The external control equipment switches on the power of the plasma monitor.  
Transmission Data  
9FH 80H 60H 4EH 00H CKS  
ACK  
The plasma monitor returns the following ACK when the power is switched on.  
3FH 60H 80H 4EH 00H CKS  
NOTE: Do not set the Power ON or Power OFF command continuously.  
02. Power OFF  
Function  
The external control equipment switches off the power of the plasma monitor.  
Transmission Data  
9FH 80H 60H 4FH 00H CKS  
ACK  
The plasma monitor returns the following ACK when the power is switched off.  
3FH 60H 80H 4FH 00H CKS  
NOTE: Do not set the Power ON or Power OFF command continuously.  
9
 
PDP-614MX External Control Manual  
03. Input Switch Change  
Function  
The external control equipment switches the input of the plasma monitor.  
Transmission Data  
DFH 80H 60H 47H 01H DATA00  
CKS  
DATA00 : Input Select  
01H : Video1  
02H : Video2  
03H : Video3  
05H : COMPNT1  
06H : COMPNT2  
07H : PC1DSUB  
08H : PC2-BNC  
0CH : PC3-DVI  
ACK  
The plasma monitor returns the following ACK when the input is switched.  
3FH 60H 80H 47H 00H CKS  
10  
 
PDP-614MX External Control Manual  
04. VOLUME Gain Data  
Function  
The external control equipment changes the VOLUME gain data of the plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02  
DATA00: USER SOUND Gain Flag 05H  
CKS  
DATA01: VOLUME Gain Flag  
DATA02: VOLUME Gain  
01H  
00H: Step0  
:
0AH: Step10 (Default)  
:
2AH: Step42  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00: USER SOUND Gain Flag  
05H  
DATA01: VOLUME Gain Flag  
01H  
05. AUDIO Mute ON  
Function  
The external control equipment switches on AUDIO Mute of the plasma monitor.  
Transmission Data  
9FH 80H 60H 3EH 00H CKS  
ACK  
3FH 60H 80H 3EH 00H CKS  
06. AUDIO Mute OFF  
Function  
The external control equipment switches off AUDIO Mute of the plasma monitor.  
Transmission Data  
9FH 80H 60H 3FH 00H CKS  
ACK  
3FH 60H 80H 3FH 00H CKS  
11  
 
PDP-614MX External Control Manual  
07. CONTRAST Gain Data  
Function  
The external control equipment changes the CONTRAST gain data of the plasma c  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02  
CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : CONTRAST Gain Flag  
DATA02 : CONTRAST Gain  
01H  
07H  
CCH : -52  
:
FFH : -01  
00H : 0  
01H : +01  
:
14H : +20  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00: USER PICTURE Gain Flag  
01H  
DATA01: CONTRAST Gain Flag  
07H  
08. BRIGHT Gain Data  
Function  
The external control equipment changes the BRIGHT gain data of the plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02  
CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : BRIGHT Gain Flag  
DATA02 : BRIGHT Gain  
01H  
08H  
E0H : -32  
:
FFH : -01  
00H : 0  
01H : +01  
:
20H : +32  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00 : USER PICTURE Gain Flag  
01H  
DATA01 : BRIGHT Gain Flag  
08H  
09. SHARPNESS Gain Data  
Function  
The external control equipment changes the SHARPNESS gain data of the plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : SHARPNESS Gain Flag  
DATA02 : SHARPNESS Gain  
01H  
06H  
F0H : -16  
:
FFH : -01  
00H : 0  
12  
 
PDP-614MX External Control Manual  
01H : +01  
:
10H : +16  
Only when a RGB signal is connected  
DATA02 : SHARPNESS Gain  
01H : 1  
02H : 2  
03H : 3  
04H : 4  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00 : USER PICTURE Gain Flag  
01H  
DATA01 : SHARPNESS Gain Flag  
06H  
13  
 
PDP-614MX External Control Manual  
10. COLOR Gain Data  
Function  
The external control equipment changes the COLOR gain data of the plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : COLOR Gain Flag  
DATA02 : COLOR Gain  
01H  
04H  
E0H : -32  
:
FFH : -01  
00H : 0  
01H : +01  
:
20H : +32  
* COLOR Gain is from -22 (EAH) to +22 (16H) only during video.  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00 : USER PICTURE Gain Flag  
01H  
DATA01 : COLOR Gain Flag  
04H  
11. TINT Gain Data  
Function  
The external control equipment changes the TINT gain data of the plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : TINT Gain Flag  
DATA02 : TINT Gain  
01H  
05H  
E0H: -32  
:
* TINT Gain is from -22 (EAH) to  
+22 (16H) only during video.  
FFH : -01  
00H : 0  
01H : +01  
:
20H : +32  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00 : USER PICTURE Gain Flag  
01H  
DATA01 : TINT Gain Flag  
05H  
12. AV SELECTION Select  
Function  
The external control equipment sets the av selection of the plasma monitor.  
Transmission Data  
DFH 80H 60H 0AH 01H DATA00 CKS  
DATA00: 01H : STD  
02H : MOVIE1*  
03H : MOVIE2*  
04H : Default  
05H : Dynamic*  
* It cannot choose in the still picture input of a personal computer  
14  
 
PDP-614MX External Control Manual  
ACK  
7FH 60H 80H 0AH 01H DATA00 CKS  
DATA00: 01H : STD  
02H : MOVIE1  
03H : MOVIE2  
04H : Default  
05H : Dynamic  
13. COLOR TEMP SELECT  
Function  
The external control equipment changes the COLOR TEMP of the plasma monitor.  
Transmission Data  
DFH 80H 60H 00H 01H DATA00  
DATA00 : 00H: low  
01H: middle  
CKS  
02H: high  
03H: middle low  
ACK  
7FH 60H 80H 00H 01H DATA00  
DATA00 : 00H: low  
01H: middle  
CKS  
02H: high  
03H: middle low  
14. RED Gain Data  
Function  
The external control equipment changes the RED Gain Data of the plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : RED Gain Flag  
DATA02 : RED Low  
01H  
01H  
D8H : -40  
:
FFH : -01  
00H : 0  
01H : +01  
:
1EH : +30  
D8H : -40  
:
DATA03: RED High  
FFH : -01  
00H : 0  
01H : +01  
:
1EH : +30  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : RED Gain Flag  
01H  
01H  
15  
 
PDP-614MX External Control Manual  
15. GREEN Gain Data  
Function  
The external control equipment changes the GREEN Gain Data of the plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : GREEN Gain Flag  
DATA02 : GREEN Low  
01H  
02H  
D8H : -40  
:
FFH : -01  
00H : 0  
01H : +01  
:
1EH : +30  
D8H : -40  
:
DATA03: GREEN High  
FFH : -01  
00H : 0  
01H : +01  
:
1EH : +30  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00: USER PICTURE Gain Flag  
DATA01: GREEN Gain Flag  
01H  
02H  
16  
 
PDP-614MX External Control Manual  
16. BLUE Gain Data  
Function  
The external control equipment changes the BLUE Gain Data of the plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : BLUE Gain Flag  
DATA02 : BLUE Low  
01H  
03H  
D8H :-40  
:
FFH : -01  
00H : 0  
01H : +01  
:
1EH : +30  
D8H :-40  
:
DATA03: BLUE High  
FFH : -01  
00H : 0  
01H : +01  
:
1EH : +30  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00: USER PICTURE Gain Flag  
01H  
DATA01: BLUE Gain Flag  
03H  
17  
 
PDP-614MX External Control Manual  
17. DNR MODE Set  
Function  
The external control equipment sets the NR (Noise Reduction) mode of the plasma monitor.  
Transmission Data  
DFH 80H 60H C0H 01H DATA00 CKS  
DATA00: 01H : OFF  
02H : LOW  
03H : MID  
04H : HIGH  
ACK  
7FH 60H 80H C0H 01H DATA00 CKS  
DATA00: 01H : OFF  
02H : LOW  
03H : MID  
04H : HIGH  
18. BASS Gain Data  
Function  
The external control equipment changes the BASS gain data of the plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02  
CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : BASS Gain Flag  
DATA02 : BASS Gain  
05H  
03H  
F3H : -13  
:
FFH : -01  
00H : 0  
01H : +01  
:
0DH : +13  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : BASS Gain Flag  
05H  
03H  
18  
 
PDP-614MX External Control Manual  
19. TREBLE Gain Data  
Function  
The external control equipment changes the TREBLE gain data of the plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : TREBLE Gain Flag  
DATA02 : TREBLE Gain  
05H  
04H  
F3H : -13  
:
FFH : -01  
00H : 0  
01H : +01  
:
0DH : +13  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00: USER PICTURE Gain Flag  
DATA01: TREBLE Gain Flag  
05H  
04H  
20. BALANCE Gain Data  
Function  
The external control equipment changes the BALANCE gain data of the plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : BALANCE Gain Flag  
DATA02 : BALANCE Gain  
05H  
02H  
EAH : -22  
:
FFH : -01  
00H : 0  
01H : +01  
:
16H : +22  
ACK  
7FH 60H 80H 7FH 02H DATA00  
DATA00: USER PICTURE Gain Flag  
DATA01: BALANCE Gain Flag  
DATA01  
CKS  
05H  
02H  
1. SCREEN SIZE Select  
Function  
The external control equipment switches the screen mode of the plasma monitor.  
Transmission Data  
DFH 80H 60H 51H 01H DATA00 CKS  
DATA00 02H : WIDE  
03H : ZOOM  
04H : STD  
05H : FULL  
06H : DOT BY DOT  
08H : UNDERSCAN  
09H : 14:9  
19  
 
PDP-614MX External Control Manual  
0AH : 2.35:1  
ACK  
7FH 60H 80H 51H 01H DATA00  
DATA00 02H : WIDE  
03H : ZOOM  
CKS  
04H : STD  
05H : FULL  
06H : DOT BY DOT  
08H : UNDERSCAN  
09H : 14:9  
0AH : 2.35:1  
20  
 
PDP-614MX External Control Manual  
22. V.POSITION Gain Data  
Function  
The external control equipment changes the V. POSITION gain data of the plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : V.POSITION Gain Flag  
DATA02 : V.POSITION Gain  
03H  
01H  
C0H : -64  
:
FFH : -01  
00H : 0  
01H : +01  
:
40H : +64  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00: USER PICTURE Gain Flag  
DATA01: V.POSITION Gain Flag  
03H  
01H  
21  
 
PDP-614MX External Control Manual  
23. H.POSITION Gain Data  
Function  
The external control equipment changes the H. POSITION gain data of the plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : H.POSITION Gain Flag  
DATA02 : H.POSITION Gain  
03H  
02H  
80H : -128  
:
FFH : -01  
00H : 0  
01H : +01  
:
7FH : +127  
ACK  
7FH 60H 80H 7FH 02H DATA00  
DATA00: USER PICTURE Gain Flag  
DATA01: H.POSITION Gain Flag  
DATA01  
03H  
02H  
CKS  
24. V.SIZE Gain Data  
Function  
The external control equipment changes the V.SIZE gain data of the plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : V.SIZE Gain Flag  
DATA02 : V.SIZE Gain  
03H  
07H  
00H : 0  
:
40H : +64  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00: USER PICTURE Gain Flag  
DATA01: V.SIZE Gain Flag  
03H  
07H  
22  
 
PDP-614MX External Control Manual  
25. H.SIZE Gain Data  
Function  
The external control equipment changes the H.SIZE gain data of the plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : H.SIZE Gain Flag  
DATA02 : H.SIZE Gain  
03H  
08H  
00H : 0  
:
40H : +64  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00: USER PICTURE Gain Flag  
DATA01: H.SIZE Gain Flag  
03H  
08H  
26. AUTO PICTURE Select  
Function  
The external control equipment switches on or off the AUTO PICTURE of the plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00  
DATA00 : USER PICTURE Gain Flag  
DATA01 : AUTO PICTURE Select Flag  
DATA02 00H : ON  
DATA01 DATA02 CKS  
03H  
09H  
01H : OFF  
ACK  
7FH 60H 80H 7FH 03H DATA00  
DATA00 : USER PICTURE Gain Flag  
DATA01 : AUTO PICTURE Select Flag  
DATA02 00H : ON  
DATA01 DATA02 CKS  
03H  
09H  
01H : OFF  
23  
 
PDP-614MX External Control Manual  
27. PHASE Gain Data  
Function  
The external control equipment changes the PHASE gain data (Phase) of the plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : PHASE Gain Flag  
DATA02 : PHASE Gain  
03H  
03H  
00H : 0  
:
40H : +64 :  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00: USER PICTURE Gain Flag  
DATA01: PHASE Gain Flag  
03H  
03H  
28. CLOCK Gain Data  
Function  
The external control equipment changes the CLOCK gain data (ratio of frequency division) of the plasma monitor.  
Transmission Data  
DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : USER PICTURE Gain Flag  
DATA01 : CLOCK Gain Flag  
DATA02 : CLOCK Gain  
03H  
04H  
C0H : -64  
:
FFH : -01  
00H : 0  
01H : +01  
:
40H : +64  
ACK  
7FH 60H 80H 7FH 02H DATA00 DATA01 CKS  
DATA00: USER PICTURE Gain Flag  
DATA01: CLOCK Gain Flag  
03H  
04H  
24  
 
PDP-614MX External Control Manual  
29. OSM ADJ. POSITION Data  
Function  
The external control equipment sets the position of the OSM menu of the plasma monitor.  
Transmission Data  
DFH 80H 60H 1AH 02H DATA00 DATA01 CKS  
DATA00 : OSM ADJ. Gain Flag  
02H  
DATA01  
01H : 1(TOP LEFT)  
02H : 2(TOP CENTER)  
03H : 3(TOP RIGHT)  
04H : 4(BOTTOM LEFT)  
05H : 5(BOTTOM CENTER)  
06H : 6(BOTTOM RIGHT)  
ACK  
7FH 60H 80H 1AH 01H DATA00 CKS  
DATA00 : OSM ADJ. Gain Flag 02H  
30. POWER MGT Select  
Function  
The external control equipment switches on or off the POWER MANAGEMENT of the plasma monitor.  
Transmission Data  
DFH 80H 60H 1AH 02H DATA00  
DATA01 CKS  
DATA00 : POWER MGT Select  
03H  
DATA01  
01H : ON  
02H : OFF  
ACK  
7FH 60H 80H 1AH 02H DATA00  
DATA01 CKS  
DATA00 : POWER MGT Select  
03H  
DATA01  
01H : ON  
02H : OFF  
31. SIDE MASK Set  
Function  
The external control equipment sets the SIDE MASK of the plasma monitor.  
Transmission Data  
DFH 80H 60H C6H 01H DATA00 CKS  
DATA00 : SIDE MASK  
00H : 0  
:
0FH : 15  
ACK  
7FH 60H 80H C6H 01H DATA00 CKS  
DATA00 : SIDE MASK  
00H : 0  
:
0FH : 15  
32. PURECINEMA Set  
25  
 
PDP-614MX External Control Manual  
Function  
The external control equipment switches on or off the PURECINEMA of the plasma monitor.  
Transmission Data  
DFH 80H 60H C1H 01H DATA00  
CKS  
DATA00 : PURECINEMA Set  
01H : ON  
02H : OFF  
ACK  
7FH 60H 80H C1H 01H DATA00  
CKS  
DATA00 : PURECINEMA Set  
01H : ON  
02H : OFF  
26  
 
PDP-614MX External Control Manual  
33. LONG LIFE Set  
Function  
The external control equipment sets the PLE, ORBITER, and INVERSE (inverse of image brightness) or WHITE of the  
plasma monitor.  
Transmission Data  
DFH 80H 60H 6BH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : PLE  
01H : AUTO  
02H : LOCK1  
03H : LOCK2  
04H : LOCK3  
01H : INVERSE  
02H : OFF  
DATA01 : INVERSE/WHITE  
DATA02 : ORBITER  
03H :WHITE  
01H : AUTO1  
02H : OFF  
03H : AUTO2  
ACK  
The plasma monitor returns the following ACK when setting the PLE, ORBITER, and INVERSE (inverse of image brightness)  
or WHITE:  
3FH 60H 80H 6BH 00H CKS  
27  
 
PDP-614MX External Control Manual  
34. SCREEN WIPER Set  
Function  
2001.7.10  
INVERSE  
Set  
The external control equipment sets the SCREEN WIPER of the plasma monitor.  
Transmission Data  
コマンド追加  
DFH 80H 60H C8H 04H DATA00 to DATA03 CKS  
DATA00 : SCREEN WIPER  
00H : No operation  
01H : ON  
02H : OFF  
DATA01 :  
DATA02 :  
DATA03 :  
00H : fixed  
FFH: fixed  
01H : fixed  
ACK  
3FH 60H 80H C8H 00H CKS  
35. ALL RESET  
Function  
The external control equipment resets the user adjustment of the plasma monitor.  
Transmission Data  
1FH 80H 60H 54H 00H CKS  
ACK  
3FH 60H 80H 54H 00H CKS  
28  
 
PDP-614MX External Control Manual  
36. Audio Select Set  
Function  
The external control equipment sets combinations of audio and video inputs for the plasma monitor.  
Transmission Data  
DFH 80H 60H 70H 02H DATA00 DATA01 CKS  
DATA00 : AUDIO INPUT  
01H : AUDIO1  
02H : AUDIO2  
03H : AUDIO3  
DATA01 : VISUAL INPUT  
01H : VIDEO1  
02H : VIDEO2  
03H : VIDEO3  
05H : COMPNT1  
06H : COMPNT2  
07H : PC1DSUB  
08H : PC2-BNC  
0CH : PC3-DVI  
ACK  
The plasma monitor returns the following ACK when the input is switched.  
3FH 60H 80H 70H 00H CKS  
* The plasma monitor returns “Not Available” when selecting the video input same as the one set at one of the AUDIO 1 to 3.  
Example:  
The plasma monitor returns “Not Available” when selecting the VIDEO1 for AUDIO2 or VIDEO3 after VIDEO1 has been set  
to AUDIO1.  
29  
 
PDP-614MX External Control Manual  
37. BNC INPUT  
Function  
The external control equipment sets the BNC SELECT of the plasma monitor.  
Transmission Data  
DFH 80H 60H 8CH 01H DATA00 CKS  
DATA00 : BNC SELECT  
01H : RGB  
02H : Component  
ACK  
The plasma monitor returns the following ACK when setting the BNC SELECT:  
7FH 60H 80H 8CH 01H DATA00 CKS  
DATA00 : BNC SELECT  
01H : RGB  
02H : Component  
38. RGB Select  
Function  
The external control equipment sets the RGB SELECT of the plasma monitor.  
Transmission Data  
DFH 80H 60H 8BH 01H DATA00 CKS  
DATA00  
01H : AUTO  
02H : STILL  
03H : MOTION  
04H : WIDE1  
05H : WIDE2  
06H : DTV  
07H : WIDE3  
08H : WIDE4  
ACK  
7FH 60H 80H 8BH 01H DATA00 CKS  
DATA00  
01H : AUTO  
02H : STILL  
03H : MOTION  
04H : WIDE1  
05H : WIDE2  
06H : DTV  
07H : WIDE3  
08H : WIDE4  
39. HD Select  
Function  
The external control equipment sets the HD SELECT of the plasma monitor.  
Transmission Data  
DFH 80H 60H 8AH 01H DATA00 CKS  
DATA00  
01H : 1035I  
02H : 1080A  
03H : 1080B  
ACK  
7FH 60H 80H 8AH 01H DATA00 CKS  
DATA00  
01H : 1035I  
02H : 1080A  
03H : 1080B  
30  
 
PDP-614MX External Control Manual  
40. LANGUAGE Select  
Function  
The external control equipment sets the LANGUAGE SELECT of the plasma monitor.  
Transmission Data  
DFH 80H 60H 5BH 01H DATA00 CKS  
DATA00: 01H : ENGLISH  
02H : GERMAN  
03H : FRENCH  
04H : SPANISH  
05H : ITALIAN  
06H : SWEDISH  
07H : JAPANESE  
0AH : CHINESE  
ACK  
7FH 60H 80H 5BH 01H DATA00 CKS  
DATA00: 01H : ENGLISH  
02H : GERMAN  
03H : FRENCH  
04H : SPANISH  
05H : ITALIAN  
06H : SWEDISH  
07H : JAPANESE  
0AH : CHINESE  
41. COLOR SYSTEM Select  
Function  
The external control equipment sets the COLOR SYSTEM of the plasma monitor.  
Transmission Data  
DFH 80H 60H 5CH 01H DATA00 CKS  
DATA00: 01H : 3.58NTSC  
02H : 4.43NTSC  
03H : PAL  
04H : SECAM  
0AH : AUTO  
0BH : PAL60  
0DH : PAL-M  
0EH : PAL-N  
ACK  
7FH 60H 80H 5CH 01H DATA00 CKS  
DATA00: 01H : 3.58NTSC  
02H : 4.43NTSC  
03H : PAL  
04H : SECAM  
0AH : AUTO  
0BH : PAL60  
0DH : PAL-M  
0EH : PAL-N  
31  
 
PDP-614MX External Control Manual  
42. FREQUENCY Request(SIGNAL INFORMATION)  
Function  
The external control equipment inquires the Horizontal frequency, Vertical frequency, Horizontal sync polarity, Vertical sync  
polarity, Mode, and Resolution of the plasma monitor.  
Transmission Data  
1FH 80H 60H 26H 00H CKS  
ACK  
7FH 60H 80H 26H 0BH DATA00 to DATA0A CKS  
Horizontal frequency  
DATA00: Integer part  
00H: 0 (No signal: 00H)  
:
FFH  
:
255  
DATA01: One decimal place 00H: 0 (No signal: 00H)  
:
09H : 9  
Vertical frequency  
DATA02: Integer part  
00H: 0 (No signal: 00H)  
:
FFH  
:
255  
DATA03: One decimal place 00H: 0 (No signal: 00H)  
:
09H  
:
9
Horizontal sync polarity  
DATA04  
00H  
:
-
01H : Positive  
02H : Negative  
Vertical sync polarity  
DATA05  
00H  
:
-
01H : Positive  
02H : Negative  
32  
 
PDP-614MX External Control Manual  
MODE  
DATA06  
00H  
: No signal  
01H to 80H : RGB signal  
Identification number of PC mode  
81H  
82H  
83H  
84H  
85H  
86H  
87H  
88H  
89H  
A0H  
A1H  
A2H  
A3H  
A4H  
A5H  
A6H  
: Video signal 3.58NTSC  
:
:
:
:
:
:
:
:
4.43NTSC  
PAL  
PAL-M  
PAL-N  
PAL60  
SECAM  
B/W60  
B/W50  
: HD/DVD/DTV signal  
480I  
:
:
:
:
:
:
480P  
576I  
576P  
720P  
1035I  
1080I  
RESOLUTION  
DATA07: Dots (Low-order byte) 00H: 0 (No signal: 00H)  
:
FFH 255  
DATA08: Dots (High-order byte) 00H: 257 (No signal: 00H)  
:
FFH  
DATA09: Lines (Low-order byte) 00H: 0 (No signal: 00H)  
:
FFH 255  
DATA10: Lines (High-order byte) 00H: 257 (No signal: 00H)  
:
FFH  
33  
 
PDP-614MX External Control Manual  
43. Input MODE Request  
Function  
The display returns the current input information by the external control equipment’ s request.  
Transmission Data  
1FH 80H 60H 41H 00H CKS  
ACK  
7FH 60H 80H 41H 01H DATA00 CKS  
DATA00 : Input Select  
01H : Video  
02H : Video2  
03H : Video3  
04H : COMPNT1  
05H : PC1DSUB  
06H : PC2-BNC  
0CH : COMPNT2  
0EH : PC3-DVI  
44. VIDEO ADJ. Request  
Function  
The display returns the video adjustments information by the external control equipment’s request.  
Transmission Data  
1FH 80H 60H 45H 00H CKS  
ACK  
7FH 60H 80H 45H 0CH DATA00 to DATA0B CKS  
DATA00: RED Gain (Low)  
DATA01: GREEN Gain (Low)  
DATA02: BLUE Gain (Low)  
DATA03: COLOR Gain  
D8H : -40  
:
FFH : -01  
00H : 0  
01H : +01  
:
1EH : +30  
D8H : -40  
:
FFH : -01  
00H : 0  
01H : +01  
:
1EH : +30  
D8H : -40  
:
FFH : -01  
00H : 0  
01H : +01  
:
1EH : +30  
E0H : -32  
:
* COLOR Gain is from -22 (EAH) to FFH : -01  
+22 (16H) only during video.  
00H : 0  
01H : +01  
:
20H : +32  
34  
 
PDP-614MX External Control Manual  
DATA04: TINT Gain  
E0H : -32  
:
* TINT Gain is from -22 (EAH) to  
+22 (16H) only during video.  
FFH : -01  
00H : 0  
01H : +01  
:
20H : +32  
DATA05: SHARPNESS Gain  
DATA06: CONTRAST Gain  
DATA07: BRIGHT Gain  
F0H : -16  
:
FFH : -01  
00H : 0  
01H : +01  
:
10H : +16  
CCH : -52  
:
FFH : -01  
00H : 0  
01H : +01  
:
14H : +20  
E0H : -32  
:
FFH : -01  
00H : 0  
01H : +01  
:
20H : +32  
DATA08: RED Gain (High)  
DATA09: GREEN Gain (High)  
DATA0A: BLUE Gain (High)  
D8H : -40  
:
FFH : -01  
00H : 0  
01H : +01  
:
1EH : +30  
D8H : -40  
:
FFH : -01  
00H : 0  
01H : +01  
:
1EH : +30  
D8H : -40  
:
FFH : -01  
00H : 0  
35  
 
PDP-614MX External Control Manual  
01H : +01  
:
1EH : +30  
DATA0B: COLOR TEMP SELECT 00H: low  
01H: middle  
02H: high  
03H: middle low  
45. Audio Select Request  
Function  
The external control equipment inquires the current combinations of audio and video inputs for the plasma monitor.  
Transmission Data  
1FH 80H 60H 6FH 00H CKS  
ACK  
The plasma monitor returns the following ACK:  
7FH 60H 80H 6FH 03H DATA00 DATA01 DATA02 CKS  
DATA00 : AUDIO1  
01H-0CH : VISUAL INPUT DATA  
DATA01 : AUDIO2  
01H-0CH : VISUAL INPUT DATA  
DATA02 : AUDIO3  
01H-0CH : VISUAL INPUT DATA  
<VISUAL INPUT DATA>  
01H : VIDEO1  
02H : VIDEO2  
03H : VIDEO3  
05H : COMPNT1  
06H : COMPNT2  
07H : PC1DSUB  
08H : PC2-BNC  
0CH : PC3-DVI  
36  
 
PDP-614MX External Control Manual  
46. Failure Mode Request  
Function  
The external control equipment inquires the detection of failures of the plasma monitor.  
Transmission Data  
1FH 80H 60H 3FH 00H CKS  
ACK  
The plasma monitor returns the following ACK:  
7FH 60H 80H 3FH 02H DATA00 DATA01 CKS  
DATA00: FAILURE MODE 1  
Bit 0 : PDP MODULE  
0: Abnormal  
1: Normal  
Bit 1 : 1: fixed (backup)  
Bit 2 : TEMPERATURE  
0: Abnormal  
1: Normal  
Bit 3 : FAN  
0: Abnormal  
1: Normal  
Bit 4 : TEMPERATURE SENSOR  
0: Abnormal  
1: Normal  
Bit 5 : 1: fixed (backup)  
Bit 6 : 1: fixed (backup)  
Bit 7 : 1: fixed (backup)  
DATA01: FAILURE MODE 2  
Bit 0-7 : 1: fixed (backup)  
37  
 
PDP-614MX External Control Manual  
47. MODEL NAME Request  
Function  
The external control equipment inquires the product code of the plasma monitor.  
Transmission Data  
1FH 80H 60H 17H 00H CKS  
ACK  
The plasma monitor returns the following ACK:  
7FH 60H 80H 17H 0CH DATA00 to DATA11 CKS  
DATA00 : 1st character of the product code  
DATA01 : 2nd character of the product code  
:
DATA11 : 12th character of the product code  
Received data  
00H-09H : 0-9  
80H  
81H  
82H  
83H  
84H  
85H  
86H  
87H  
96H  
:
:
:
:
:
:
:
:
- (Hyphen)  
+
/
(
)
.
:
Blank  
10H-29H  
: A-Z  
Corresponding  
character  
A
B
C
D
E
F
G
H
I
J
Received data (H) 10 11 12 13 14 15 16 17 18 19  
Corresponding  
character  
K
L
M
N
O
P
Q
R
S
T
Received data (H) 1A 1B 1C 1D 1E 1F 20 21 22 23  
Corresponding  
character  
U
V
W
X
Y
Z
Received data (H) 24 25 26 27 28 29  
If there are fewer than 12 characters in the product code, product code would be padded right with blanks.  
Example: If the product code of your plasma monitor is “50XGA”, the returned codes would be as follows.  
DATA00:05H, DATA01:00H, DATA02:27H, DATA03:16H, DATA04:10H, DATA05:96H, DATA06:96H, DATA07:96H,  
DATA08:96H, DATA09:96H, DATA10:96H, DATA11:96H  
38  
 
PDP-614MX External Control Manual  
48.LOW TONE  
Function  
The external control equipment sets the dithering processing or error diffusion processing of the plasma monitor.  
Transmission Data  
DFH 80H 60H 0CH 01H DATA00 CKS  
DATA00:  
00H:AUTO  
01H: dithering processing(for motion picture)  
02H: dithering processing (for still picture)  
03H: error diffusion processing  
ACK  
7FH 60H 80H 0CH 01H DATA00 CKS  
DATA00:  
00H:AUTO  
01H: dithering processing  
02H: dithering processing  
03H: error diffusion processing  
39  
 
PDP-614MX External Control Manual  
49. C.DETAIL ADJ  
Function  
External control equipment can adjust RGB each color which a plasma monitor wants to emphasize.  
Transmission Data  
DFH 80H 60H 0DH 07H DATA00 to DATA06 CKS  
DATA00:RED  
00H : -32  
:
20H : 0  
:
40H : +32  
DATA01:GREEN  
DATA02:BLUE  
DATA03:YELLOW  
DATA04:MAZENTA  
DATA05:CYAN  
DATA06:RESET  
00H : -32  
:
20H : 0  
:
40H : +32  
00H : -32  
:
20H : 0  
:
40H : +32  
00H : -32  
:
20H : 0  
:
40H : +32  
00H : -32  
:
20H : 0  
:
40H : +32  
00H : -32  
:
20H : 0  
:
40H : +32  
00H : OFF  
01H : ON  
ACK  
7FH 60H 80H 0DH 00H CKS  
50.GAMMA GAIN Data  
Function  
External control apparatus changes Gamma of a plasma monitor.  
Transmission Data  
DFH 80H 60H 13H 02H DATA00 DATA01 CKS  
DATA00: GAMMA FLAG  
01H : Gamma change  
00H :1(GAMMA2.1)  
01H :2(GAMMA2.2)  
02H :3(GAMMA2.3)  
03H :4(GAMMA2.4)  
DATA01: GAMMA  
40  
 
PDP-614MX External Control Manual  
ACK  
7FH 60H 80H 13H 01H DATA00 CKS  
DATA00: GAMMA FLAG 01H : Gamma change  
41  
 
PDP-614MX External Control Manual  
51.Running Sense  
Function  
External control apparatus grasps the power supply state of a plasma monitor.  
A plasma monitor is made to recognize connection of PC CONTROL.  
Transmission Data  
1FH 80H 60H 88H 00H CKS  
ACK  
7FH 60H 80H 88H 01H DATA CKS  
DATA: Bit0:Connect Condition  
0: No connection  
1: Connected  
Bit1 0: Fixed  
1:-  
Bit2:Power Status  
0:POWER ON  
1:POWER OFF(STANBY)  
Bit3 0: Fixed  
Bit4 0: Fixed  
Bit5 0: Fixed  
Bit6 0: Fixed  
Bit7 0: Fixed  
42  
 
PDP-614MX External Control Manual  
52. OSM OBITER  
Function  
In order to decrease printing of a screen by OSM display, whenever it displays OSM, shift operation of the OSM is carried out.  
Transmission Data  
DFH 80H 60H 5FH 01H DATA00  
CKS  
DATA00  
ACK  
01H : OBITER ON  
02H : OBITER OFF  
7FH 60H 80H 5FH 01H DATA00  
CKS  
DATA00  
01H : OBITER ON  
02H : OBITER OFF  
53. Input Skip  
Function  
In a monitor's key "an input change", when there is no signal, it flies and shifts to the following channel.  
Transmission Data  
DFH 80H 60H 61H 01H DATA00  
CKS  
DATA00  
ACK  
01H : ON  
02H : OFF  
7FH 60H 80H 61H 01H DATA00  
CKS  
DATA00  
01H : ON  
02H : OFF  
43  
 
PDP-614MX External Control Manual  
54. SERIAL No. Request  
Function  
External control apparatus read the serial number of the set recorded by EEPROM of a plasma display.  
Transmission Data  
1FH 80H 60H 15H 00H CKS  
ACK  
7FH 60H 80H 15H 0CH DATA00 to DATA11 CKS  
Even DATA00-DATA11 is set up as follows.  
Setting value  
00H-09H  
96H  
:
:
0 - 9  
Blank  
10H-29H  
:
A-Z of Alphabet  
55.S1/S2 SELECT  
Function  
External control apparatus sets up the S1/S2 detection of a plasma monitor.  
Transmission Data  
DFH 80H 60H 89H 01H DATA00 CKS  
DATA00  
01H : AUTO  
02H : OFF  
ACK  
7FH 60H 80H 89H 01H DATA00 CKS  
DATA00  
01H : AUTO  
02H : OFF  
44  
 
PDP-614MX External Control Manual  
56.SOFT FOCUS  
Function  
External control apparatus sets up the Soft Focus of a plasma monitor.  
Transmission Data  
DFH 80H 60H 65H 01H DATA00 CKS  
DATA00 01H : OFF  
02H : LEVEL1  
03H : LEVEL2  
04H : LEVEL3  
05H : LEVEL4  
ACK  
7FH 60H 80H 65H 01H DATA00 CKS  
DATA00 01H : OFF  
02H : LEVEL1  
03H : LEVEL2  
04H : LEVEL3  
05H : LEVEL4  
57.PLUG and PLAY  
Function  
External control apparatus sets up the Plug and Play of a plasma monitor.  
Transmission Data  
DFH 80H 60H 8EH 01H DATA00 CKS  
DATA00 01H : PC  
02H : STB/DVD(HDCP signal)  
ACK  
7FH 60H 80H 8EH 01H DATA00 CKS  
DATA00 01H : PC  
02H : STB/DVD(HDCP signal)  
45  
 
PDP-614MX External Control Manual  
58.BLACK LEVEL SELECT  
Function  
External control apparatus sets up the black level (digital signal level) of a plasma monitor.  
Transmission Data  
DFH 80H 60H 8FH 01H DATA00 CKS  
DATA00 01H : LOW  
02H : HIGH  
ACK  
7FH 60H 80H 8FH 01H DATA00 CKS  
DATA00 01H : LOW  
02H : HIGH  
59.OSM CONTRAST SELECT  
Function  
External control apparatus selects the OSM contrast function of a plasma monitor.  
Transmission Data  
DFH 80H 60H 37H 01H DATA00 CKS  
DATA00 01H : NORMAL  
02H : LOW  
ACK  
7FH 60H 80H 37H 01H DATA00 CKS  
DATA00 01H : NORMAL  
02H : LOW  
.60OSM Select  
Function  
The external control equipment switches on or off the on-screen menu (OSM) of the plasma monitor.  
Transmission Data  
DFH 80H 60H 58H 01H DATA00 CKS  
DATA00:  
01H: On-Screen menu On  
02H: On-Screen menu Off  
ACK  
7FH 60H 80H 58H 01H DATA00 CKS  
DATA00:  
01H: On-Screen menu On  
02H: On-Screen menu Off  
*Operation is as described in the table below.  
On-Screen Menu (OSM)  
Display of items and adjustments  
on the menu  
Volume display, input display, and  
screen size display  
Operation  
When  
screen When  
screen When  
screen When  
screen  
menu is ON  
menu is OFF  
menu is ON  
menu is OFF  
46  
 
PDP-614MX External Control Manual  
Remote  
control  
operation  
Personal  
computer  
control  
Yes  
No  
Yes  
Yes  
No  
No  
Yes  
No  
operation  
61. INVERSE Set  
Function  
2001.7.10  
INVERSE  
Set  
The external control equipment sets the INVERSE (inverse of image brightness) and the WHITE of the plasm
Transmission Data  
コマンド追加  
DFH 80H 60H C7H 03H DATA00 DATA01 DATA02 CKS  
DATA00: INVERSE/WHITE  
00H : No operation  
01H : ON (INVERSE)  
02H : OFF  
03H : WHITE  
DATA01 : WORKING TIME  
00H : ON  
01H: 03M (minutes)  
02H: 06M (minutes)  
:
FFH: 12H (hours) and 45M (minutes)  
01H: 03M (minutes)  
02H: 06M (minutes)  
:
DATA02 : WAITING TIME  
FFH: 12H (hours) and 45M (minutes)  
ACK  
3FH 60H 80H C7H 00H CKS  
NOTE: The WORKING TIME and the WAITING TIME can be set in  
units of 3 minutes.  
Example: 03H=9 minutes  
1EH=1 hour and 30 minutes  
47  
 
PDP-614MX External Control Manual  
62. TIMER SWITCH  
Function  
The external control equipment sets the timer reservation of the plasma monitor.  
Transmission Data  
DFH 80H 60H 02H 01H DATA00 CKS  
DATA00:  
00H : Reservation OFF  
01H : Reservation ON  
ACK  
7FH 60H 80H 02H 01H DATA00 CKS  
DATA00:  
00H : Reservation OFF  
01H : Reservation ON  
63. TIMER PROGRAM SETTING  
Function  
External control apparatus sets up the timer program of a plasma monitor.  
Transmission Data  
DFH 80H 60H 30H 08H DATA00 to DATA07 CKS  
DATA00 PROGRAM No  
01H~07H  
DATA01 DATE  
01H~07H  
08H  
:No1~No7  
: Sunday - Saturday  
: Every day  
09H~0FH  
: Every week Sunday - every week Saturday  
FFH : - (with No Setup)  
DATA02 ON time (HOUR)  
00H~09H  
10H~19H  
20H~23H  
:00~09  
:10~19  
:20~23  
FFH : - (with No Setup)  
DATA03 ON time (MIN)  
00H~09H  
10H~19H  
20H~29H  
30H~39H  
40H~49H  
50H~59H  
:00~09  
:10~19  
:20~29  
:30~39  
:40~49  
:50~59  
FFH : - (with No Setup)  
DATA04 OFF time (HOUR)  
00H~09H  
10H~19H  
20H~23H  
:00~09  
:10~19  
:20~23  
FFH : - (with No Setup)  
DATA05 OFF time(MIN)  
00H~09H  
10H~19H  
20H~29H  
30H~39H  
40H~49H  
50H~59H  
:00~09  
:10~19  
:20~29  
:30~39  
:40~49  
:50~59  
FFH : - (with No Setup)  
48  
 
PDP-614MX External Control Manual  
DATA06 INPUT  
01H  
02H  
: Video1  
: Video2  
03H  
: Video3  
04H  
: COMPNT1  
: COMPNT2  
: PC1DSUB  
: PC2-BNC  
: PC3-DVI  
05H  
06H  
07H  
08H  
FFH  
: - (with No Setup)  
DATA07 MODE  
01H  
: OBIT  
: INV  
02H  
03H  
: WT  
04H  
: WIPER  
FFH : - (with No Setup)  
ACK  
7FH 60H 80H 30H 00H CKS  
64. PRESENT TIME SETTING  
Function  
External control apparatus sets up the present time of a plasma monitor.  
Transmission Data  
DFH 80H 60H 31H 03H DATA00 to DATA02 CKS  
DATA00 Day of the week 01H-07H : 1-7 (Sunday - Saturday)  
DATA01 HOUR  
DATA02 minutes  
00H-09H:00-09  
10H~19H:10~19  
20H~23H:20~23  
00H-09H:00-09  
10H~19H:10~19  
20H~29H:20~29  
30H~39H:30~39  
40H~49H:40~49  
50H~59H:50~59  
ACK  
7FH 60H 80H 31H 00H CKS  
65. MULTI MODE Select  
Function  
External control apparatus changes MULTI MODE of a plasma monitor.  
Transmission Data  
DFH 80H 60H 03H 03H DATA00 DATA01 DATA02 CKS  
DATA00 (SCREEN DIVIDER SETTING)  
01H : Single mode  
02H : Multi mode 1 screens  
03H : Multi mode 4 screens  
04H : Multi mode 9 screens  
05H : Multi mode 16 screens  
06H : Multi mode 25 screens  
49  
 
PDP-614MX External Control Manual  
DATA01 (POSITION OF DIVIDE)  
01H : Upper left selected (4 screens)  
02H : Upper right selected (4 screens)  
03H : Lower right selected (4 screens)  
04H : Lower left selected (4 screens)  
07H : Top left selected (9 screens)  
08H : Top middle selected (9 screens)  
09H : Top right selected (9 screens)  
0AH : Middle left selected (9 screens)  
0BH : Middle centerselected (9 screens)  
0CH : Middle rightselected (9 screens)  
0DH : Bottom leftselected (9 screens)  
0EH : Bottom middle selected (9 screens)  
0FH : Bottom right selected (9 screens)  
10H : position1(16 screens,refer to figure1)  
11H : position2(16 screens,refer to figure1)  
:
18H : position9(16 screens,refer to figure1)  
19H : position10(16 screens,refer to figure1)  
:
1FH : position16 (16 screens,refer to figure1)  
20H : position1(25 screens,refer to figure2)  
21H : position2(25 screens,refer to figure2)  
:
29H : position10(25 screens,refer to figure2)  
2AH : position11(25 screens,refer to figure2)  
:
32H : position19(25 screens,refer to figure2)  
33H : position20(25 screens,refer to figure2)  
:
38H : position25(25 screens,refer to figure2)  
1
6
2
7
3
8
4
9
5
1
6
2
7
3
8
4
10  
15  
9
11  
16  
21  
12  
17  
22  
13  
18  
23  
14  
11  
16  
12  
17  
13  
18  
14  
19  
19 20  
24 25  
Figure1  
Figure2  
DATA02 (DISP MODE)  
00H : SPLIT  
01H : BRANKING  
ACK  
7FH 60H 80H 03H 03H DATA00 DATA01 DATA02 CKS  
DATA00 (SCREEN DIVIDER SETTING)  
01H : Single mode  
02H : Multi mode 1 screens  
03H : Multi mode 4 screens  
04H : Multi mode 9 screens  
50  
 
PDP-614MX External Control Manual  
05H : Multi mode 16 screens  
06H : Multi mode 25 screens  
DATA01 (POSITION OF DIVIDE)  
01H : Upper left selected (4 screens)  
02H : Upper right selected (4 screens)  
03H : Lower right selected (4 screens)  
04H : Lower left selected (4 screens)  
07H : Top left selected (9 screens)  
08H : Top middle selected (9 screens)  
09H : Top right selected (9 screens)  
0AH : Middle left selected (9 screens)  
0BH : Middle centerselected (9 screens)  
0CH : Middle rightselected (9 screens)  
0DH : Bottom leftselected (9 screens)  
0EH : Bottom middle selected (9 screens)  
0FH : Bottom right selected (9 screens)  
10H : position1(16 screens,refer to figure1)  
11H : position2(16 screens,refer to figure1)  
:
18H : position9(16 screens,refer to figure1)  
19H : position10(16 screens,refer to figure1)  
:
1FH : position16 (16 screens,refer to figure1)  
20H : position1(25 screens,refer to figure2)  
21H : position2(25 screens,refer to figure2)  
:
29H : position10(25 screens,refer to figure2)  
2AH : position11(25 screens,refer to figure2)  
:
32H : position19(25 screens,refer to figure2)  
33H : position20(25 screens,refer to figure2)  
:
38H : position25(25 screens,refer to figure2)  
1
6
2
7
3
8
4
9
5
1
6
2
7
3
8
4
10  
15  
9
11  
16  
21  
12  
17  
22  
13  
18  
23  
14  
11  
16  
12  
17  
13  
18  
14  
19  
19 20  
24 25  
Figure1  
Figure2  
DATA02 (DISP MODE)  
00H : SPLIT  
01H : BRANKING  
66. MULTI MODE Request  
Function  
External control apparatus can know the MULTI MODE information on a plasma monitor.  
51  
 
PDP-614MX External Control Manual  
Transmission Data  
1FH 80H 60H 3BH 00H CKS  
ACK  
7FH 80H 60H 3BH 02H DATA00 DATA01 DATA02 CKS  
DATA00 (SCREEN DIVIDER SETTING)  
01H : Single mode  
02H : Multi mode 1 screens  
03H : Multi mode 4 screens  
04H : Multi mode 9 screens  
05H : Multi mode 16 screens  
06H : Multi mode 25 screens  
DATA01 (POSITION OF DIVIDE)  
01H : Upper left selected (4 screens)  
02H : Upper right selected (4 screens)  
03H : Lower right selected (4 screens)  
04H : Lower left selected (4 screens)  
07H : Top left selected (9 screens)  
08H : Top middle selected (9 screens)  
09H : Top right selected (9 screens)  
0AH : Middle left selected (9 screens)  
0BH : Middle centerselected (9 screens)  
0CH : Middle rightselected (9 screens)  
0DH : Bottom leftselected (9 screens)  
0EH : Bottom middle selected (9 screens)  
0FH : Bottom right selected (9 screens)  
10H : position1(16 screens,refer to figure1)  
11H : position2(16 screens,refer to figure1)  
:
18H : position9(16 screens,refer to figure1)  
19H : position10(16 screens,refer to figure1)  
:
1FH : position16 (16 screens,refer to figure1)  
20H : position1(25 screens,refer to figure2)  
21H : position2(25 screens,refer to figure2)  
:
29H : position10(25 screens,refer to figure2)  
2AH : position11(25 screens,refer to figure2)  
:
32H : position19(25 screens,refer to figure2)  
33H : position20(25 screens,refer to figure2)  
:
38H : position25(25 screens,refer to figure2)  
1
6
2
7
3
8
4
9
5
1
6
2
7
3
8
4
10  
15  
9
11  
16  
21  
12  
17  
22  
13  
18  
23  
14  
11  
16  
12  
17  
13  
18  
14  
19  
19 20  
24 25  
Figure1  
Figure2  
52  
 
PDP-614MX External Control Manual  
DATA02 (DISP MODE)  
00H : SPLIT  
01H : BRANKING  
53  
 
PDP-614MX External Control Manual  
67. AUTO ID SET START  
Function  
External control apparatus sets up ID automatically to two or more plasma monitors.  
Transmission Data  
5FH 80H 60H F0H 01H DATA00 CKS  
DATA00  
00H~FFH: ID of a master*1 is set up.  
*: When you use it by the multi-system, please remove the link input of a master*1.  
*1: “Master” means the 1st set of PDP at the time of cable connection at the time of AUTO ID execution.  
68. PLE LINK  
Function  
External control apparatus sets up equally PLE between two or more plasma monitors.  
Transmission Data  
DFH 80H 60H F1H 03H DATA00 to DATA02 CKS  
DATA00 00H:PLE LINK ON  
01H:PLE LINK OFF  
DATA01 FFH(fixed)  
DATA02 FFH(fixed)  
*:Turn on the AUTO ID and set the DIVIDER(at 1,4 or 9), before this operation  
69. VIDEO WALL SETTING  
Function  
External control apparatus sets 4screens or 9screens as a video wall.  
Transmission Data  
DFH 80H 60H F3H 03H DATA00 DATA01 DATA02 CKS  
DATA00:  
01H:1 screen  
(Matrix diplay function does not work.)  
04H:4 screens (2*2 video wall)  
09H:9 screens (3*3 video wall)  
00H(fixed)  
DATA 01:  
DATA 02:  
01H : Video1  
02H : Video2  
03H : Video3  
04H : COMPNT1  
05H : COMPNT2  
06H : COMPNT3  
07H : PC1DSUB  
08H : PC2-BNC  
09H : PC3-DVI  
*:Turn on the AUTO ID, before this operation  
*: This command is used to following system.  
1. The system configuration is video wall system (4screens or 9screens).  
Then please connect each PDP by wired cable.  
In the case of 16 screens or 25 screens video wall system, please refer to No.65.”MULTI MODE Select”.  
2. The ID number from a master display is set the continuous number.  
54  
 
PDP-614MX External Control Manual  
55  
 
PDP-614MX External Control Manual  
70. POWER DELAY ON(at 4 or 9 multiscreen)  
Function  
External control apparatus attaches a time lag to two or more plasma monitors, and turns on a power supply.  
Transmission Data  
DFH 80H 60H F2H 01H DATA00 CKS  
DATA00: 00H-FFH: Delay time (second)  
*:Turn on the AUTO ID and set the DIVIDER(at 4 or 9), before this operation  
*: This command is premised on two or more plasma monitor system composition being multi-systems. In command issue of  
master1 OSD operation, the value of DATA00 is 01H (1 second). This command does not have ACK for one-way traffic.  
*1: “Master” means the 1st set of PDP at the time of cable connection at the time of AUTO ID execution.  
71. POWER DELAY ON (at 16 or 25 multi screens)  
Function  
External control apparatus attaches a time lag to 10 or more plasma monitors, and turns on a power supply.  
Transmission Data  
DFH 80H 60H F6H 01H DATA00 CKS  
DATA00: 01H  
02H  
mode1  
mode2  
ACK  
7FH 60H 80H F6H 01H DATA00 CKS  
DATA00: 01H  
02H  
mode1  
mode2  
NOTE: When multi mode is 16 or 25, this function is available.  
56  
 
PDP-614MX External Control Manual  
72. ORBITER SET  
Function  
A picture shift function is set up.  
Transmission Data  
DFH 80H 60H 1EH 04H DATA00 to DATA03 CKS  
DATA00: Mode  
00H : OFF  
01H : Auto 1  
02H : Auto 2  
03H : Manual  
DATA01: The horizontal amount of movements  
1 dot : 01H  
to  
: -  
20 dot : 14H  
DATA02: The vertical amount of movements  
One line : 01H  
to  
: -  
20 line : 14H  
DATA03: Interval of operation 1 - 5 minutes : 01H - 05H  
ACK  
7FH 60H 80H 1EH 01H DATA00 CKS  
DATA00: Mode  
00H : OFF  
01H : Auto 1  
02H : Auto 2  
03H : Manual  
* DATA01-03  
Auto1,2 setting : 01H fixed  
Manual setting : Please set DATA 01-03.  
73. OSM ANGLE  
Function  
The vertical display of OSM and a horizontal display are chosen.  
Transmission Data  
DFH 80H 60H 60H 01H DATA00  
CKS  
DATA00  
01H : Horizontal display  
02H : Vertical display  
ACK  
7FH 60H 80H 60H 01H DATA00  
CKS  
DATA00  
01H : Horizontal display  
02H : Vertical display  
74. PICTURE Size  
Function  
Screen mode selection.  
57  
 
PDP-614MX External Control Manual  
Transmission Data  
DFH 80H 60H 2AH 01H DATA00  
DATA00 01H : ON  
CKS  
CKS  
02H : OFF  
ACK  
7FH 60H 80H 2AH 01H DATA00  
DATA00 01H : ON  
02H : OFF  
75. OPTION Select  
Function  
Power-on mode, a control lock, and IR remote are set up.  
Transmission Data  
DFH 80H 60H 63H 04H DATA00 to DATA03 CKS  
DATA00 : Power ON mode  
00H : LAST  
01H : Video1  
02H : Video2  
03H : Video3  
05H : COMPNT1  
06H: COMPNT2  
07H : PC1DSUB  
08H : PC2-BNC  
0CH : PC3-DVI  
00H : OFF  
DATA01 : Control Lock  
DATA02 : IR remote  
DATA03 : Loop Out  
01H : ON  
00H : OFF  
01H : ON  
00H : OFF  
01H : ON  
ACK  
7FH 60H 80H 63H 00H CKS  
76. REPEAT Timer  
Function  
External control apparatus sets up the repeat timer of a plasma monitor.  
Transmission Data  
DFH 80H 60H 64H 07H DATA00 to DATA06 CKS  
DATA00  
00H :REPEAT Timer OFF  
01H :REPEAT Timer ON  
DATA01 PROGRAM 1  
01H :DIVIDER 1  
02H :DIVIDER 4  
03H :DIVIDER 9  
DATA02 SOURCE 01H :Video1  
02H :Video2  
03H :Video3  
05H : COMPNT1  
06H : COMPNT2  
07H : PC1DSUB  
08H : PC2-BNC  
58  
 
PDP-614MX External Control Manual  
0CH : PC3-DVI  
DATA03 WORK TIME  
01 H-FFH:1 - 255 minutes (1 minute - 4 hours and 15 minutes)  
DATA04 PROGRAM 1  
01H :DIVIDER 1  
02H :DIVIDER 4  
03H :DIVIDER 9  
DATA05 SOURCE 01H :Video1  
02H :Video2  
03H :Video3  
05H : COMPNT1  
06H : COMPNT2  
07H : PC1DSUB  
08H : PC2-BNC  
0CH : PC3-DVI  
DATA06 WORK TIME  
01 H-FFH:1 - 255 minutes (1 minute - 4 hours and 15 minutes)  
ACK  
7FH 60H 80H 64H 00H CKS  
*:Turn on the AUTO ID, before this operation  
59  
 
External Control Manual  
RS-232C Configuration  
(for PDP-614MX and PDP-424MV)  
Pioneer Electronics (USA) Inc.  
Industrial Solutions Business Group  
2265 East 220th Street  
Long Beach, CA 90810  
 

Philips DVD Player DVD743HC 021 User Manual
Philips Electric Shaver 282XL User Manual
Philips Stereo Amplifier CGY887 User Manual
Philips Stereo Amplifier TDA1562Q User Manual
Playskool Games 34676 User Manual
Poulan Snow Blower 415153 User Manual
PQI Computer Drive 20 Plus User Manual
Presto Gas Grill 07050 User Manual
Pride Mobility Mobility Aid Jazzy 100 User Manual
ProForm Home Gym PFEX97573 User Manual