Procom Indoor Fireplace V50TYLA BC User Manual

Installation Instructions and Homeowners Manual  
WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE MAY RESULT  
CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.  
FOR YOUR SAFETY  
DO NOT STORE  
OR USE GASOLINE OR OTHER  
FLAMMABLE VAPORS OR LIQUIDS  
IN THE VICINITY OF THIS OR ANY  
OTHER APPLIANCE  
INSTALLER: DO NOT DISCARD THIS MANUAL-LEAVE FOR HOME OWNER  
PC(220)-VCL100-01-0709  
 
GENERAL  
13. Do not insert or allow foreign objects to enter any  
1. Read all instructions before using this  
appliance.  
ventilation or exhaust opening as this may cause  
electric shock, fire or damage to the appliance.  
14. To prevent fire, do not block air intakes or exhaust  
in any manner. Do not use on soft surfaces, such  
as a bed, where openings may become blocked.  
15. This appliance has hot and arcing or sparking parts  
inside. Do not use it in areas where gasoline, paint,  
or flammable liquids are used or stored. This elec-  
tric fireplace should not be used as a drying rack  
for clothing, Also, do not have Christmas stock-  
ings or decorations hung on or near it.  
2. This appliance is hot when in use. To avoid  
burns, do not let bare skin touch hot surfaces.  
Keep combustible materials, such as furniture,  
pillows, bedding, papers, clothes, and curtains  
at least 3 feet(1m.) from the front of this  
appliance.  
3. CAUTION: Extreme caution is necessary when  
any heater is used by or near children or inva-  
lids and whenever the heater is left Operating  
and unattended.  
16. Use this appliance only as described in this  
manual. All other uses not recommended by the  
manufacturer may cause fire, electric shock, or  
injury.  
4. Always unplug heater when not in use.  
5. Do not operate any heater with a damaged  
cord or plug or after the heater malfunctions,  
has been dropped or damaged in any manner.  
6. Any repairs to this appliance should be carried  
out by a qualified service person.  
17. Avoid the use of an extension cord because it may  
overheat and cause a fire hazard. However if you  
must use an extension cord, the cord shall be  
7. Under no circumstances should this electric fire-  
place be modified. Parts having to be removed  
for servicing must be replaced prior to operat-  
ing this electric fireplace again.  
2
1.0 mm ,1900 Watts. The extension cord must  
be a three wire cord with grounding type plug  
and cord connector.  
18.SAVE THESE INSTRUCTIONS.  
8. Do not use outdoors.  
9. This heater is not intended for use in bathrooms,  
laundry areas or similar indoor locations. Never  
use this appliance near a bathtub or other wa-  
ter container.  
LOCATING YOUR ELECTRIC FIREPLACE  
Your new freestanding electric fireplace may be  
installed virtually anywhere in your home.  
However when choosing a location for your  
new electric fireplace, ensure that the general  
instructions are followed. For best effect results, install  
the electric fireplace out of direct sunlight.  
10. Do not run cord under carpeting. Do not cover  
cord with throw rugs, runners or the like. Arrange  
cord away from traffic areas and where it will not  
be tripped over.  
11. To disconnect this appliance, turn controls to  
the off position and remove plug from outlet.  
12. Connect to properly grounded outlets only.  
3
 
CLEARANCE TO COMBUSTIBLES  
WARNING: Electrical outlet wiring  
must comply with local building  
codes and all other applicable  
regulations to reduce the risk of  
fire, electrical shock and injury.  
Back…………………………0mm  
Sides……………..…………0mm  
Floor……………. .…………0mm  
Top………………. .…………610mm  
WARNING: Do not use this  
fireplace if any part of it has been  
under water. Immediately call a  
qualified service technician to  
inspect the fireplace and replace  
any part of the electrical system if  
necessary.  
ELECTRICAL CONNECTION  
A 10 AMP, 220 Volt,50Hz circuit with a properly  
grounded outlet is required. Preferably, the stove will  
be on a dedicated circuit. Other appliances on the  
same circuit may cause the circuit breaker to trip or  
the fuse to blow when the heater is on operation.  
The unit comes standard with a 6(1828mm) long  
three wire cord exiting from the rear of the fireplace.  
Plan the installation to avoid the use of an extension  
cord. If an extention cord must be used, it must be a  
ELECTRICAL SPECIFICATIONS  
Voltage………………220 VAC/50Hz  
Total Amps…………..6.5 Amps  
Total Watts…………..1350 Watts  
Heater Ratings………1200 Watts  
2
minumum 1.0 mm three wire with grounding type  
plug connector and rated no less than 1900 Watts.  
SERVICE INSTRUCTIONS  
WARNING: Disconnect power before  
attempting any maintenance or cleaning  
to reduce the risk of fire, electrical shock  
or personal injury  
7. Install the new light bulb(s) by holding the socket  
and screwing them.  
8. Reinstall the log set and screen. Follow the above  
procedure in reverse order.  
9. The diameter of the pilot light bulb is 5mm. If the pilot  
light bulb need to be replaced, follow steps 1,2,3,4  
above. Then use the pilot light bulb socket w/wiring  
assembly replace the primary pilot part, and connect  
wires according to primary connection . Then follow  
step 8 above.  
REPLACING LIGHT BULBS  
This fireplace uses two clear 220 Volt, 60 Watt, E-14 socket  
base light bulbs (small base, chandelier candle type).The  
60 Watt bulbs are located under the log set/ember bed. For  
convenience, if one of the bulbs burns out, it may be a good  
idea to replace both of the light bulbs.  
1. Turn off power to the unit by unplugging the power cord.  
2. Let fireplace cool if it has been operating.  
3. Remove the two fixing self-tapping screws on the screen.  
Pull the screen upward a little bit, and then out.  
4. Remove the two screws that secure the log set in position.  
5. Examine the bulbs to determine which bulbs need to be  
replaced.  
WARNING: Do not exceed 60  
Watts per bulb. Use of higher  
rated bulbs may result in a fire  
causing property damage and  
personal injury.  
6. While holding the socket, unscrew the defective bulb (s).  
4
 
MAINTENANCE OF MOTORS  
GLASS INFORMATION  
The motors used on the fan and flame genera-  
tor assembly are prelubricated for extended  
bearing life and require no further lubrication.  
However, periodic cleaning/vacuuming of the  
fan/heater unit is recommended.  
1. Under no circumstances should this product  
be operated with missing or broken glass.  
2. Do not strike or slam the glass.  
3. Do not use abrasive cleaners to clean the glass.  
4. Replacement glass is available from the manu  
facturer and replacement should be carried out  
by a qualified service person.  
WARNING: Make sure that the  
power is turned off before  
proceeding.  
ELECTRICAL WIRING DIAGRAM  
Any electrical repairs or rewiring of this unit should be carried out by a licensed electrician in accordance  
with national and local codes.  
If repairing or replacing any electrical component or wiring, the original wire  
routing, color coding and securing location must be followed.  
5
 
Operating Instructions  
This section provides easy step by step instructions for operating your fireplace.  
1. Make sure the unit is unplugged from the power source  
2. Plug the fireplace into a 10AMP/220V outlet. If the cord does not reach, you may use an  
extension cord rated for a minimum of 1900 watts.  
To access the controls, open the bottom of the fireplace at the front of the unit (see Figure A).  
A. MAIN ON/OFF SWITCH  
The on/off switch supplies power to all fireplace functions (heater/flame).  
B. HEATER THERMOSTAT CONTROL  
To adjust the temperature to your needs, turn the thermostat control completely clockwise to turn on  
the heater. When the room reaches the desired temperature, turn the thermostat knob counter  
clockwise until you hear a click. Leave it in this position to maintain the room temperature at this  
setting. For additional heat, turn clockwise until you hear the click again and the heater will turn on.  
To turn the heater off, switch the HEATER ON/OFF SWITCH to the OFF position.  
C. HEATER ON/OFF SWITCH  
The HEATER ON/OFF SWITCH supplies power to the heater fan and the heater element.  
NOTE: When switched ON, the heater fan will operate. The heater element may or may not be  
on, depending on the thermostat control setting (see HEATER THERMOSTAT CONTROL).  
When the HEATER/FAN pilot light is lighting, it indicate that the heater is on.  
Warning: During any service of this appliance, the power to the unit must be turned off. It is  
not acceptable to use the ON/OFFswitch to meet this requirement. (Refer to operating  
instruction section)  
D. INSTRUCTIONS FOR POWER  
This heater is for use on 220 volts only. The green/yellow grounding lug extending from the adapter  
must be connected to a permanent ground such as a properly grounded outlet box. The adapter  
should not be used if a three-slot grounded receptacle is available.  
6
 
SPECIFICATIONS:  
Model: V50TYLA-C  
Model: V50TYLA-O  
Voltage: 220V/50HZ Total Amps: 6.5A  
Total Watts: 1350W Heating Ratings: 1200W  
Dimensions, CM (H x W X D)  
Voltage: 220V/50HZ Total Amps: 6.5A  
Total Watts: 1350W Heating Ratings: 1200W  
Dimensions, CM (H x W X D)  
Fireplace  
Carton  
97.8x67x35.9  
Fireplace  
Carton  
97.8x67x35.9  
105.1x74.5x44.1  
105.1x74.5x44.1  
Weight, Kgs  
Fireplace  
Shipping  
Weight, Kgs  
Fireplace  
Shipping  
35.9  
43.1  
35.9  
43.1  
Model: V50TYLA-DO  
Model: V50TYLA-BC  
Voltage: 220V/50HZ Total Amps: 6.5A  
Total Watts: 1350W Heating Ratings: 1200W  
Dimensions, CM(H x W X D)  
Voltage: 220V/50HZ Total Amps: 6.5A  
Total Watts: 1350W Heating Ratings: 1200W  
Dimensions, CM (H x W X D)  
Fireplace  
Carton  
97.8x67x35.9  
Fireplace  
Carton  
97.8x67x35.9  
105.1x74.5x44.1  
105.1x74.5x44.1  
Weight, Kgs  
Fireplace  
Shipping  
Weight, Kgs  
Fireplace  
Shipping  
35.9  
43.1  
35.9  
43.1  
Model: V50TYLAR-BC  
Voltage: 220V/50HZ Total Amps: 6.5A  
Total Watts: 1350W Heating Ratings: 1200W  
Dimensions, CM (H x W X D)  
Fireplace  
Carton  
97.8x67x35.9  
105.1x74.5x44.1  
Weight, Kgs  
Fireplace  
Shipping  
35.9  
43.1  
7
 
REPLACEMENT PARTS PICTURES OF  
V50TYLA-O V50TYLA-C V50TYLA-DO V50TYLAR-BC V50TYLA-BC  
2
9
7
6
5
4
8
 
V50TYLA-O  
Item# Part Descripition  
Part Number  
VL050-01A  
1
Log Set  
2
Fan/Heater Assembly  
NFHTX186-R/VB17-000-R  
FE23A307  
3
Synchronization Motor-220Volt AC w/Terminal  
Cord Power H05VV-F3GX1.0 w/Terminal  
ON/OFF Switch  
4
NFHL008-R-A  
VL067-01  
5
6
Heater Control (Thermostat)  
Heater Control Knob  
VL053-02  
7
NFHL012  
8
Flame Generator Assembly/Firewood Glisten Paper PT/32GS370/FE33A205-01  
9
Light Bulb Socket w/W iring Assembly  
Screen  
PE28A306-R  
EB29600  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
Top Panel  
EL040-01-O  
EL015-06-O  
EL012-06  
Side Panel (Right/Left)  
Lower Panel  
Door  
EL013-01  
Brass Knob  
224A  
Back Panel  
EL019-01-B  
EL018-06RA-O  
EL016-06H-O  
EL011-01  
Base  
Upper Decorating Frame  
Upper Decorating W ire  
Upper (Mid) Louver  
Pilot Light Bulb Socket w/W iring Assembly  
Base Plate ( Not shown)  
Driverwheel 2(Not shown)  
Switch Mount Panel ( Not shown)  
VL015-01(VL014-01)  
VL080-01  
VL091-01-R  
VL005-03A  
VL004-01F  
9
 
V50TYLA-C  
Item# Part Descripition  
Part Number  
VL050-01A  
1
2
Log Set  
Fan/Heater Assembly  
NFHTX186-R/VB17-000-R  
FE23A307  
3
Synchronization Motor-220Volt AC w/Terminal  
Cord Power H05VV-F3GX1.0 w/Terminal  
ON/OFF Switch  
4
NFHL008-R-A  
VL067-01  
5
6
Heater Control (Thermostat)  
Heater Control Knob  
VL053-02  
7
NFHL012  
8
Flame Generator Assembly/Firewood Glisten Paper PT/32GS370/FE33A205-01  
9
Light Bulb Socket w/Wiring Assembly  
Screen  
PE28A306-R  
EB29600  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
Top Panel  
EL040-01-C  
EL015-06-C  
EL012-06  
Side Panel (Right/Left)  
Left Lower Panel/Right Lower Panel  
Door  
EL013-01  
Brass Knob  
224A  
Back Panel  
EL019-01-B  
EL018-06RA-C  
EL016-06B-C  
EL011-01  
Base  
Upper Decorating Frame  
Upper Decorating Wire  
Upper (Mid) Louver  
VL015-01(EL014-01)  
VL080-01  
Pilot Light Bulb Socket w/Wiring Assembly  
Base Plate ( Not shown)  
Driver Wheel 1/ Driverwheel 2(Not shown)  
Switch Mount Panel ( Not shown)  
VL091-01-R  
VL005-03A  
VL004-01F  
10  
 
V50TYLA-DO  
Item# Part Descripition  
Part Number  
VL050-01A  
1
Log Set  
2
Fan/Heater Assembly  
NFHTX186-R/VB17-000-R  
FE23A307  
3
Synchronization Motor-220Volt AC w/Terminal  
Cord Power H05VV-F3GX1.0 w/Terminal  
ON/OFF Switch  
4
NFHL008-R-A  
VL067-01  
5
6
Heater Control (Thermostat)  
Heater Control Knob  
VL053-02  
7
NFHL012  
8
Flame Generator Assembly/Firewood Glisten Paper  
Light Bulb Socket w/Wiring Assembly  
Screen  
PT/32GS370/FE33A205-01  
PE28A306-R  
EB29600  
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
Top Panel  
EL040-01-DO  
EL015-06-DO  
EL012-06  
Side Panel (Right/Left)  
Left Lower Panel/Right Lower Panel  
Door  
EL013-01  
Brass Knob  
224A  
Back Panel  
EL019-01-B  
EL018-06RA-DO  
EL016-06H-O  
EL011-01  
Base  
Upper Decorating Frame  
Upper Decorating Wire  
Upper (Mid) Louver  
VL015-01(VL014-01)  
VL080-01  
Pilot Light Bulb Socket w/Wiring Assembly  
Base Plate ( Not shown)  
Driver Wheel 1/ Driverwheel 2(Not shown)  
Switch Mount Panel ( Not shown)  
VL091-01-R  
VL005-03A  
VL004-01F  
1 1  
11  
 
V50TYLA-BC  
Item#  
1
Part Descripition  
Log Set  
Part Number  
VL050-01A  
2
Fan/Heater Assembly  
NFHTX186-R/VB17-000-R  
FE23A307  
3
Synchronization Motor-220Volt AC w/Terminal  
Cord Power H05VV-F3GX1.0 w/Terminal  
ON/OFF Switch  
4
NFHL008-R-A  
VL067-01  
5
6
Heater Control (Thermostat)  
Heater Control Knob  
VL053-02  
7
NFHL012  
8
Flame Generator Assembly/Firewood Glisten Paper PT/32GS370/FE33A205-01  
9
Light Bulb Socket w/Wiring Assembly  
Screen  
PE28A306-R  
EB29600  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
Top Panel  
EL040-01-BC  
EL015-06-BC  
EL012-06  
Side Panel (Right/Left)  
Lower Panel  
Door  
EL013-01  
Brass Knob  
224A  
Back Panel  
EL019-01-B  
EL018-06RA-BC  
EL016-06H-BC  
EL011-01  
Base  
Upper Decorating Frame  
Upper Decorating Wire  
Upper (Mid) Louver  
Pilot Light Bulb Socket w/Wiring Assembly  
Base Plate ( Not shown)  
Driverwheel 2(Not shown)  
Switch Mount Panel ( Not shown)  
VL015(VL014-01)  
VL080-01  
VL091-01-R  
VL005-03A  
VL004-01F  
12  
 
V50TYLAR-BC  
Item# Part Descripition  
Part Number  
VL050-01A  
1
2
Log Set  
Fan/Heater Assembly  
NFHTX186-R/VB17-000-R  
FE23A307  
3
Synchronization Motor-220Volt AC w/Terminal  
Cord Power H05VV-F3GX1.0 w/Terminal  
ON/OFF Switch  
4
NFHL008-R-A  
VL067-01  
5
6
Heater Control (Thermostat)  
Heater Control Knob  
VL053-02  
7
NFHL012  
8
Flame Generator Assembly/Firewood Glisten Paper PT/32GS370/FE33A205-01  
9
Light Bulb Socket w/Wiring Assembly  
Screen  
PE28A306-R  
EB29600  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
Top Panel  
EL018-06RA-C  
EL015-06A(B)H-C  
EL012-06  
Side Panel (Right/Left)  
Left Lower Panel/Right Lower Panel  
Door  
EL013-01  
Brass Knob  
224A  
Back Panel  
EL019-01-B  
EL018-06RA-C  
EL016-06B-C  
EL011-01  
Base  
Upper Decorating Frame  
Upper Decorating Wire  
Upper (Mid) Louver  
VL015-01(EL014-01)  
VL080-01  
Pilot Light Bulb Socket w/Wiring Assembly  
Base Plate ( Not shown)  
Driver Wheel 1/ Driverwheel 2(Not shown)  
Switch Mount Panel ( Not shown)  
VL091-01-R  
VL005-03A  
VL004-01F  
13  
 

Peavey Stereo Amplifier 646 049 User Manual
Philips Flat Panel Television M2239CLE1T User Manual
Philips TV Cables SWV6514 User Manual
Philips Work Light P 5611 B User Manual
Pioneer Flat Panel Television PRO 1140HD User Manual
Poulan Snow Blower 436430 User Manual
Power Acoustik Car Stereo System PA 360EQ User Manual
Prince Castle Toaster 212 GFCCE User Manual
Princeton Home Theater Server 4411 0087 User Manual
Printronix Printer SLPA8000r MP2 User Manual