Installation Instructions and Homeowner’s Manual
WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE MAY RESULT
CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY
DO NOT STORE
OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS OR LIQUIDS
IN THE VICINITY OF THIS OR ANY
OTHER APPLIANCE
INSTALLER: DO NOT DISCARD THIS MANUAL-LEAVE FOR HOME OWNER
PC(220)-VCL100-01-0709
GENERAL
13. Do not insert or allow foreign objects to enter any
1. Read all instructions before using this
appliance.
ventilation or exhaust opening as this may cause
electric shock, fire or damage to the appliance.
14. To prevent fire, do not block air intakes or exhaust
in any manner. Do not use on soft surfaces, such
as a bed, where openings may become blocked.
15. This appliance has hot and arcing or sparking parts
inside. Do not use it in areas where gasoline, paint,
or flammable liquids are used or stored. This elec-
tric fireplace should not be used as a drying rack
for clothing, Also, do not have Christmas stock-
ings or decorations hung on or near it.
2. This appliance is hot when in use. To avoid
burns, do not let bare skin touch hot surfaces.
Keep combustible materials, such as furniture,
pillows, bedding, papers, clothes, and curtains
at least 3 feet(1m.) from the front of this
appliance.
3. CAUTION: Extreme caution is necessary when
any heater is used by or near children or inva-
lids and whenever the heater is left Operating
and unattended.
16. Use this appliance only as described in this
manual. All other uses not recommended by the
manufacturer may cause fire, electric shock, or
injury.
4. Always unplug heater when not in use.
5. Do not operate any heater with a damaged
cord or plug or after the heater malfunctions,
has been dropped or damaged in any manner.
6. Any repairs to this appliance should be carried
out by a qualified service person.
17. Avoid the use of an extension cord because it may
overheat and cause a fire hazard. However if you
must use an extension cord, the cord shall be
7. Under no circumstances should this electric fire-
place be modified. Parts having to be removed
for servicing must be replaced prior to operat-
ing this electric fireplace again.
2
1.0 mm ,1900 Watts. The extension cord must
be a three wire cord with grounding type plug
and cord connector.
18.SAVE THESE INSTRUCTIONS.
8. Do not use outdoors.
9. This heater is not intended for use in bathrooms,
laundry areas or similar indoor locations. Never
use this appliance near a bathtub or other wa-
ter container.
LOCATING YOUR ELECTRIC FIREPLACE
Your new freestanding electric fireplace may be
installed virtually anywhere in your home.
However when choosing a location for your
new electric fireplace, ensure that the general
instructions are followed. For best effect results, install
the electric fireplace out of direct sunlight.
10. Do not run cord under carpeting. Do not cover
cord with throw rugs, runners or the like. Arrange
cord away from traffic areas and where it will not
be tripped over.
11. To disconnect this appliance, turn controls to
the off position and remove plug from outlet.
12. Connect to properly grounded outlets only.
3
CLEARANCE TO COMBUSTIBLES
WARNING: Electrical outlet wiring
must comply with local building
codes and all other applicable
regulations to reduce the risk of
fire, electrical shock and injury.
Back…………………………0mm
Sides……………..…………0mm
Floor……………. .…………0mm
Top………………. .…………610mm
WARNING: Do not use this
fireplace if any part of it has been
under water. Immediately call a
qualified service technician to
inspect the fireplace and replace
any part of the electrical system if
necessary.
ELECTRICAL CONNECTION
A 10 AMP, 220 Volt,50Hz circuit with a properly
grounded outlet is required. Preferably, the stove will
be on a dedicated circuit. Other appliances on the
same circuit may cause the circuit breaker to trip or
the fuse to blow when the heater is on operation.
The unit comes standard with a 6’ (1828mm) long
three wire cord exiting from the rear of the fireplace.
Plan the installation to avoid the use of an extension
cord. If an extention cord must be used, it must be a
ELECTRICAL SPECIFICATIONS
Voltage………………220 VAC/50Hz
Total Amps…………..6.5 Amps
Total Watts…………..1350 Watts
Heater Ratings………1200 Watts
2
minumum 1.0 mm three wire with grounding type
plug connector and rated no less than 1900 Watts.
SERVICE INSTRUCTIONS
WARNING: Disconnect power before
attempting any maintenance or cleaning
to reduce the risk of fire, electrical shock
or personal injury
7. Install the new light bulb(s) by holding the socket
and screwing them.
8. Reinstall the log set and screen. Follow the above
procedure in reverse order.
9. The diameter of the pilot light bulb is 5mm. If the pilot
light bulb need to be replaced, follow steps 1,2,3,4
above. Then use the pilot light bulb socket w/wiring
assembly replace the primary pilot part, and connect
wires according to primary connection . Then follow
step 8 above.
REPLACING LIGHT BULBS
This fireplace uses two clear 220 Volt, 60 Watt, E-14 socket
base light bulbs (small base, chandelier candle type).The
60 Watt bulbs are located under the log set/ember bed. For
convenience, if one of the bulbs burns out, it may be a good
idea to replace both of the light bulbs.
1. Turn off power to the unit by unplugging the power cord.
2. Let fireplace cool if it has been operating.
3. Remove the two fixing self-tapping screws on the screen.
Pull the screen upward a little bit, and then out.
4. Remove the two screws that secure the log set in position.
5. Examine the bulbs to determine which bulbs need to be
replaced.
WARNING: Do not exceed 60
Watts per bulb. Use of higher
rated bulbs may result in a fire
causing property damage and
personal injury.
6. While holding the socket, unscrew the defective bulb (s).
4
MAINTENANCE OF MOTORS
GLASS INFORMATION
The motors used on the fan and flame genera-
tor assembly are prelubricated for extended
bearing life and require no further lubrication.
However, periodic cleaning/vacuuming of the
fan/heater unit is recommended.
1. Under no circumstances should this product
be operated with missing or broken glass.
2. Do not strike or slam the glass.
3. Do not use abrasive cleaners to clean the glass.
4. Replacement glass is available from the manu
facturer and replacement should be carried out
by a qualified service person.
WARNING: Make sure that the
power is turned off before
proceeding.
ELECTRICAL WIRING DIAGRAM
Any electrical repairs or rewiring of this unit should be carried out by a licensed electrician in accordance
with national and local codes.
If repairing or replacing any electrical component or wiring, the original wire
routing, color coding and securing location must be followed.
5
Operating Instructions
This section provides easy step by step instructions for operating your fireplace.
1. Make sure the unit is unplugged from the power source。
2. Plug the fireplace into a 10AMP/220V outlet. If the cord does not reach, you may use an
extension cord rated for a minimum of 1900 watts.
To access the controls, open the bottom of the fireplace at the front of the unit (see Figure A).
A. MAIN ON/OFF SWITCH
The on/off switch supplies power to all fireplace functions (heater/flame).
B. HEATER THERMOSTAT CONTROL
To adjust the temperature to your needs, turn the thermostat control completely clockwise to turn on
the heater. When the room reaches the desired temperature, turn the thermostat knob counter
clockwise until you hear a click. Leave it in this position to maintain the room temperature at this
setting. For additional heat, turn clockwise until you hear the click again and the heater will turn on.
To turn the heater off, switch the HEATER ON/OFF SWITCH to the OFF position.
C. HEATER ON/OFF SWITCH
The HEATER ON/OFF SWITCH supplies power to the heater fan and the heater element.
NOTE: When switched ON, the heater fan will operate. The heater element may or may not be
on, depending on the thermostat control setting (see “HEATER THERMOSTAT CONTROL”).
When the HEATER/FAN pilot light is lighting, it indicate that the heater is on.
Warning: During any service of this appliance, the power to the unit must be turned off. It is
not acceptable to use the “ON/OFF” switch to meet this requirement. (Refer to operating
instruction section)
D. INSTRUCTIONS FOR POWER
This heater is for use on 220 volts only. The green/yellow grounding lug extending from the adapter
must be connected to a permanent ground such as a properly grounded outlet box. The adapter
should not be used if a three-slot grounded receptacle is available.
6
SPECIFICATIONS:
Model: V50TYLA-C
Model: V50TYLA-O
Voltage: 220V/50HZ Total Amps: 6.5A
Total Watts: 1350W Heating Ratings: 1200W
Dimensions, CM (H x W X D)
Voltage: 220V/50HZ Total Amps: 6.5A
Total Watts: 1350W Heating Ratings: 1200W
Dimensions, CM (H x W X D)
Fireplace
Carton
97.8x67x35.9
Fireplace
Carton
97.8x67x35.9
105.1x74.5x44.1
105.1x74.5x44.1
Weight, Kgs
Fireplace
Shipping
Weight, Kgs
Fireplace
Shipping
35.9
43.1
35.9
43.1
Model: V50TYLA-DO
Model: V50TYLA-BC
Voltage: 220V/50HZ Total Amps: 6.5A
Total Watts: 1350W Heating Ratings: 1200W
Dimensions, CM(H x W X D)
Voltage: 220V/50HZ Total Amps: 6.5A
Total Watts: 1350W Heating Ratings: 1200W
Dimensions, CM (H x W X D)
Fireplace
Carton
97.8x67x35.9
Fireplace
Carton
97.8x67x35.9
105.1x74.5x44.1
105.1x74.5x44.1
Weight, Kgs
Fireplace
Shipping
Weight, Kgs
Fireplace
Shipping
35.9
43.1
35.9
43.1
Model: V50TYLAR-BC
Voltage: 220V/50HZ Total Amps: 6.5A
Total Watts: 1350W Heating Ratings: 1200W
Dimensions, CM (H x W X D)
Fireplace
Carton
97.8x67x35.9
105.1x74.5x44.1
Weight, Kgs
Fireplace
Shipping
35.9
43.1
7
REPLACEMENT PARTS PICTURES OF
V50TYLA-O V50TYLA-C V50TYLA-DO V50TYLAR-BC V50TYLA-BC
2
9
7
6
5
4
8
V50TYLA-O
Item# Part Descripition
Part Number
VL050-01A
1
Log Set
2
Fan/Heater Assembly
NFHTX186-R/VB17-000-R
FE23A307
3
Synchronization Motor-220Volt AC w/Terminal
Cord Power H05VV-F3GX1.0 w/Terminal
ON/OFF Switch
4
NFHL008-R-A
VL067-01
5
6
Heater Control (Thermostat)
Heater Control Knob
VL053-02
7
NFHL012
8
Flame Generator Assembly/Firewood Glisten Paper PT/32GS370/FE33A205-01
9
Light Bulb Socket w/W iring Assembly
Screen
PE28A306-R
EB29600
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Top Panel
EL040-01-O
EL015-06-O
EL012-06
Side Panel (Right/Left)
Lower Panel
Door
EL013-01
Brass Knob
224A
Back Panel
EL019-01-B
EL018-06RA-O
EL016-06H-O
EL011-01
Base
Upper Decorating Frame
Upper Decorating W ire
Upper (Mid) Louver
Pilot Light Bulb Socket w/W iring Assembly
Base Plate ( Not shown)
Driverwheel 2(Not shown)
Switch Mount Panel ( Not shown)
VL015-01(VL014-01)
VL080-01
VL091-01-R
VL005-03A
VL004-01F
9
V50TYLA-C
Item# Part Descripition
Part Number
VL050-01A
1
2
Log Set
Fan/Heater Assembly
NFHTX186-R/VB17-000-R
FE23A307
3
Synchronization Motor-220Volt AC w/Terminal
Cord Power H05VV-F3GX1.0 w/Terminal
ON/OFF Switch
4
NFHL008-R-A
VL067-01
5
6
Heater Control (Thermostat)
Heater Control Knob
VL053-02
7
NFHL012
8
Flame Generator Assembly/Firewood Glisten Paper PT/32GS370/FE33A205-01
9
Light Bulb Socket w/Wiring Assembly
Screen
PE28A306-R
EB29600
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Top Panel
EL040-01-C
EL015-06-C
EL012-06
Side Panel (Right/Left)
Left Lower Panel/Right Lower Panel
Door
EL013-01
Brass Knob
224A
Back Panel
EL019-01-B
EL018-06RA-C
EL016-06B-C
EL011-01
Base
Upper Decorating Frame
Upper Decorating Wire
Upper (Mid) Louver
VL015-01(EL014-01)
VL080-01
Pilot Light Bulb Socket w/Wiring Assembly
Base Plate ( Not shown)
Driver Wheel 1/ Driverwheel 2(Not shown)
Switch Mount Panel ( Not shown)
VL091-01-R
VL005-03A
VL004-01F
10
V50TYLA-DO
Item# Part Descripition
Part Number
VL050-01A
1
Log Set
2
Fan/Heater Assembly
NFHTX186-R/VB17-000-R
FE23A307
3
Synchronization Motor-220Volt AC w/Terminal
Cord Power H05VV-F3GX1.0 w/Terminal
ON/OFF Switch
4
NFHL008-R-A
VL067-01
5
6
Heater Control (Thermostat)
Heater Control Knob
VL053-02
7
NFHL012
8
Flame Generator Assembly/Firewood Glisten Paper
Light Bulb Socket w/Wiring Assembly
Screen
PT/32GS370/FE33A205-01
PE28A306-R
EB29600
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Top Panel
EL040-01-DO
EL015-06-DO
EL012-06
Side Panel (Right/Left)
Left Lower Panel/Right Lower Panel
Door
EL013-01
Brass Knob
224A
Back Panel
EL019-01-B
EL018-06RA-DO
EL016-06H-O
EL011-01
Base
Upper Decorating Frame
Upper Decorating Wire
Upper (Mid) Louver
VL015-01(VL014-01)
VL080-01
Pilot Light Bulb Socket w/Wiring Assembly
Base Plate ( Not shown)
Driver Wheel 1/ Driverwheel 2(Not shown)
Switch Mount Panel ( Not shown)
VL091-01-R
VL005-03A
VL004-01F
1 1
11
V50TYLA-BC
Item#
1
Part Descripition
Log Set
Part Number
VL050-01A
2
Fan/Heater Assembly
NFHTX186-R/VB17-000-R
FE23A307
3
Synchronization Motor-220Volt AC w/Terminal
Cord Power H05VV-F3GX1.0 w/Terminal
ON/OFF Switch
4
NFHL008-R-A
VL067-01
5
6
Heater Control (Thermostat)
Heater Control Knob
VL053-02
7
NFHL012
8
Flame Generator Assembly/Firewood Glisten Paper PT/32GS370/FE33A205-01
9
Light Bulb Socket w/Wiring Assembly
Screen
PE28A306-R
EB29600
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Top Panel
EL040-01-BC
EL015-06-BC
EL012-06
Side Panel (Right/Left)
Lower Panel
Door
EL013-01
Brass Knob
224A
Back Panel
EL019-01-B
EL018-06RA-BC
EL016-06H-BC
EL011-01
Base
Upper Decorating Frame
Upper Decorating Wire
Upper (Mid) Louver
Pilot Light Bulb Socket w/Wiring Assembly
Base Plate ( Not shown)
Driverwheel 2(Not shown)
Switch Mount Panel ( Not shown)
VL015(VL014-01)
VL080-01
VL091-01-R
VL005-03A
VL004-01F
12
V50TYLAR-BC
Item# Part Descripition
Part Number
VL050-01A
1
2
Log Set
Fan/Heater Assembly
NFHTX186-R/VB17-000-R
FE23A307
3
Synchronization Motor-220Volt AC w/Terminal
Cord Power H05VV-F3GX1.0 w/Terminal
ON/OFF Switch
4
NFHL008-R-A
VL067-01
5
6
Heater Control (Thermostat)
Heater Control Knob
VL053-02
7
NFHL012
8
Flame Generator Assembly/Firewood Glisten Paper PT/32GS370/FE33A205-01
9
Light Bulb Socket w/Wiring Assembly
Screen
PE28A306-R
EB29600
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Top Panel
EL018-06RA-C
EL015-06A(B)H-C
EL012-06
Side Panel (Right/Left)
Left Lower Panel/Right Lower Panel
Door
EL013-01
Brass Knob
224A
Back Panel
EL019-01-B
EL018-06RA-C
EL016-06B-C
EL011-01
Base
Upper Decorating Frame
Upper Decorating Wire
Upper (Mid) Louver
VL015-01(EL014-01)
VL080-01
Pilot Light Bulb Socket w/Wiring Assembly
Base Plate ( Not shown)
Driver Wheel 1/ Driverwheel 2(Not shown)
Switch Mount Panel ( Not shown)
VL091-01-R
VL005-03A
VL004-01F
13
|