Renesas Computer Hardware H8 3297 Series User Guide

H8/3297 Series, H8/329 Series  
QFP-64A  
User System Interface Cable  
(HS3297ECH61H)  
for E6000 Emulator  
User’s Manual  
HS3297ECH61HE(C)  
 
Preface  
Thank you for purchasing the E6000 emulator for the Renesas’s original microprocessor H8/300  
series.  
The HS3297ECH61H is a user system interface cable that connects an H8/300 series E6000  
emulator (HS3008EPI60H; hereinafter referred to as the emulator) to the IC socket for a QFP-64A  
package (package code: FP-64A) for the H8/3297 series or H8/329 series MCU on the user  
system.  
i
 
Contents  
ii  
 
Section 1 Configuration  
CAUTION  
Use an IC149-064-008-B5 socket (manufactured by  
YAMAICHI ELECTRONICS Co., Ltd.) for the FP-64A package  
IC socket on the user system.  
Figure 1 shows the configuration of the HS3297ECH61H user system interface cable for the  
FP-64A package.  
1
 
 
Screws (M2.0 x 12 mm)  
and flat washers  
(For fastening cable  
head)  
Screws (M2.0 x 8 mm)  
and flat washers  
Socket cover  
Cable head  
IC socket  
User system  
Figure 1 HS3297ECH61H User System Interface Cable  
2
 
Table 1 lists the HS3297ECH61H components. Please make sure you have all of these  
components when unpacking.  
Table 1  
HS3297ECH61H Components  
No. Component  
Quantity  
Remarks  
1
2
3
4
5
6
Cable body  
1
1
1
1
4
4
Includes flat cable  
Cable head  
IC socket  
For the FP-64A package  
Socket cover  
For installing an FP-64A-packaged MCU  
For fastening cable head (with four flat washers)  
Screws (M2.0 x 12 mm)  
Screws (M2.0 x 8 mm)  
For installing an FP-64A-packaged MCU (with  
four flat washers)  
7
Documentation  
1
User’s manual for HS3297ECH61H (this manual)  
3
 
Section 2 Connection Procedures  
2.1  
Connecting User System Interface Cable to Emulator Station  
WARNING  
Always switch OFF the user system and the emulator  
product before the USER SYSTEM INTERFACE CABLE  
is connected to or removed from any part. Before connecting,  
make sure that pin 1 on both sides are correctly aligned. Failure to  
do so will damage the user system and the emulator product or will  
result in PERSONAL INJURY. The USER PROGRAM will be  
LOST.  
To connect the cable body to the emulator station, follow the instructions below.  
1. Make sure the user system and emulator station are turned off.  
2. After making sure the direction of the cable body connector is correct, firmly insert the cable  
body connector into the emulator station socket (figure 2).  
Figure 2 Connecting User System Interface Cable to Emulator Station  
4
 
 
2.2  
Connecting User System Interface Cable to User System  
WARNING  
Always switch OFF the user system and the emulator  
product before the USER SYSTEM INTERFACE CABLE  
is connected to or removed from any part. Before connecting,  
make sure that pin 1 on both sides are correctly aligned. Failure to  
do so will damage the user system and the emulator product or will  
result in PERSONAL INJURY. The USER PROGRAM will be  
LOST.  
To connect the cable head to the user system, follow the instructions below.  
2.2.1 Installing IC Socket  
After checking the location of pin 1 on the IC socket, apply epoxy resin adhesive to the bottom of  
the IC socket for an FP-64A package, and fasten it to the user system before soldering.  
2.2.2  
Soldering IC Socket  
After fastening, solder the IC socket for an FP-64A package to the user system. Be sure to  
completely solder the leads so that the solder slops gently over the leads and forms solder fillets.  
(Use slightly more solder than the MCU.)  
2.2.3  
Inserting Cable Head  
CAUTION  
Check the location of pin 1 before inserting.  
Align pin 1 on the IC socket for an FP-64A package on the user system with pin 1 on the user  
system interface cable head, and insert the user system interface cable head into the IC socket on  
the user system, as shown in figure 3.  
5
 
 
2.2.4  
Fastening Cable Head  
CAUTION  
1. Use a Phillips-type screwdriver whose head matches  
the screw head.  
2. The tightening torque must be 0.0784 N•m or less.  
If the applied torque cannot be accurately measured,  
stop tightening when the force required to turn the screw  
becomes significantly greater than that needed when first  
tightening. If a screw is tightened too much, the screw head  
may break or an IC socket contact error may be caused by  
a crack in the IC socket solder.  
3. If the emulator does not operate correctly, cracks might  
have occurred in the solder. Check conduction with  
a tester and re-solder the IC socket if necessary.  
Fasten the user system interface cable head to the IC socket for an FP-64A package on the user  
system with the four screws (M2.0 x 12 mm) provided. Each screw should be tightened a little at  
a time, alternating between screws on opposing corners. Take special care, such as manually  
securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by  
overtightening the screws or twisting the components.  
6
 
 
Screws (M2.0 x 12 mm)  
and flat washers  
Cable head  
Pin 1  
IC socket  
(IC149-064-008-B5  
manufactured by  
YAMAICHI ELECTRONICS  
Co., Ltd.)  
User system  
Figure 3 Connecting User System Interface Cable to User System  
7
 
2.2.5  
Connecting Cable Body to Cable Head  
Connect the cable body to the cable head.  
Cable body  
Removing  
Push the remove jig  
Remove jig  
Cable head  
User system  
Figure 4 Fastening Cable Body  
8
 
 
2.3  
Recommended Dimensions for User System Mount Pad  
Figure 5 shows the dimensions for the recommended mount pad (footprint) for the user system  
with an IC socket for an FP-64A package (IC149-064-008-B5: manufactured by YAMAICHI  
ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from  
those of the actual chip's mount pad.  
2 - 20.80 min  
2 - 14.80 max  
0.80 x 15 = 12.00 ± 0.10  
+ 0.10  
0.45  
-
0.05  
0.80 ± 0.05  
Unit: mm  
Figure 5 Recommended Dimensions for Mount Pad  
9
 
 
2.4  
Dimensions for User System Interface Cable Head  
The dimensions for the user system interface cable head are shown in figure 6.  
Figure 6 Dimensions for User System Interface Cable Head  
10  
 
 
2.5  
Resulting Dimensions after Connecting User System Interface Cable  
The resulting dimensions, after connecting the user system interface cable head to the user system,  
are shown in figure 7.  
Unit: mm  
Tolerance: ± 0.5 mm  
IC socket  
(IC149-064-008-B5  
User system  
manufactured by  
YAMAICHI ELECTRONICS Co., Ltd.)  
Figure 7 Resulting Dimensions after Connecting User System Interface Cable  
11  
 
 
Section 3 Installing the MCU to the User System  
CAUTION  
1. Check the location of pin 1 before inserting.  
2. Use a Phillips-type screwdriver whose head matches  
the screw head.  
3. The tightening torque must be 0.0784 N•m or less.  
If the applied torque cannot be accurately measured,  
stop tightening when the force required to turn the screw  
becomes significantly greater than that needed when first  
tightening. If a screw is tightened too much, the screw head  
may break or an IC socket contact error may be caused by  
a crack in the IC socket solder.  
4. If the MCU does not operate correctly, cracks might have  
occurred in the solder. Check conduction with a tester  
and re-solder the IC socket if necessary.  
Check the location of pin 1 before inserting the MCU into the IC socket on the user system, as  
shown in figure 8. After inserting the MCU, fasten the socket cover with the provided four  
screws (M2.0 x 8 mm). Take special care, such as manually securing the IC socket soldered area,  
to prevent the IC socket from being damaged by overtightening the screws or twisting the  
components.  
12  
 
 
Socket cover  
MCU  
Pin 1 mark  
IC socket  
(IC149-064-008-B5  
manufactured by  
YAMAICHI ELECTRONICS Co., Ltd.)  
User system  
Figure 8 Installing MCU to User System  
13  
 
Section 4 Verifying Operation  
1. When using the H8/300 series E6000 emulator (HS3008EPI60H), turn on the emulator  
according to the procedures described in the H8/300 Series E6000 Emulator User's Manual  
(HS3008EPI60HE).  
2. Verify the user system interface cable connections by accessing the external memory and ports  
to check the bus states of the pins. If an error is detected, recheck the soldered IC socket and  
the location of pin 1.  
3. The emulator connected to this user system interface cable supports two kinds of clock  
sources: an emulator internal clock and an external clock on the user system. For details, refer  
to the H8/300 Series E6000 Emulator User's Manual (HS3008EPI60HE).  
To use the emulator internal clock  
Select the clock in the emulator station as the system clock (φ), by using the CLOCK  
command (emulator command).  
To use the external clock on the user system as the system clock  
Select target clock t or t2 with the CLOCK command (emulator command). Supply the  
external clock from the user system to the emulator. Connect a crystal oscillator to the  
EXTAL and XTAL terminals for the system clock. In the H8/3297 series, the system  
clock (φ) has the same frequency as the external clock, and in the H8/329 series, the system  
clock has a half frequency of the external clock.  
Figure 9 shows the oscillator circuit on the user system interface cable.  
R1 1 M  
HCU04  
HCU04  
R2 270  
To E6000  
emulator  
EXTAL  
XTAL  
System clock  
Figure 9 Oscillator Circuit  
14  
 
 
Section 5 Notice  
1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable  
head before inserting the cable head into the user system IC socket.  
2. The dimensions of the recommended mount pad for the user system IC socket are different  
from those of the MCU.  
3. This user system interface cable is specifically designed for the HS3008EPI60H emulator. Do  
not use this cable with any other emulator station.  
4. To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on  
the user system interface cable.  
5. While the emulator station is connected to the user system with the user system interface  
cable, force must not be applied to the cable head. Place the emulator station, user system  
interface cable, and user system as shown in the example in figure 10.  
Figure 10 User Cable Location Example  
6. The P1 short connector is used for testing. Do not remove the short pins that are inserted in  
the sides of pin 1 and pin 2.  
1
3
P1  
Figure 11 P1 Short Connector  
15  
 
 

PYLE Audio Stereo Amplifier PTA3000 User Guide
Quatech Network Card MPA 200 300 User Guide
Ranger Radio TR 127GK DX User Guide
Rockford Fosgate Stereo Amplifier 240X4 User Guide
Rowenta Electric Shaver EP304 User Guide
Runco Flat Panel Television XP OPAL50 Plasma User Guide
Samsung CD Player SH C522C User Guide
Samsung DVD Recorder SE 208AB TSBS User Guide
Sanyo Security Camera VDC DP7584 User Guide
Senco Power Screwdriver DS200 D2 User Guide