Roper Clothes Dryer RGX5634P User Guide

®
Gas Dryer  
PRODUCT MODEL NUMBERS  
OVERALL DIMENSIONS  
RGX5634P  
22³⁄₄"  
(57.8cm)  
15¹⁄₄"  
(38.74cm)  
43³⁄₈"  
43³⁄₈"  
(110cm)  
A. Small Opening  
Side-Swing Door  
(110cm)  
Gas supply: This dryer is equipped for use with  
natural gas. It is design-certified by CSA  
B. Large Opening  
Side-Swing Door  
International for L.P. (propane or butane) gases  
with appropriate conversion. When rigid pipe is  
used it should be 1/2 inch IPS. When acceptable to  
the gas supplier and local codes, 3/8-inch  
approved tubing may be used for lengths under  
20 feet. For lengths over 20 feet, larger tubing  
should be used. Pipe-joint compounds resistant to  
the action of L.P. gas must be used. If local codes  
permit, it is recommended that new flexible metal  
tubing, design-certified by AGA or CSA, be used  
for connecting the appliance to the rigid gas  
supply line. (The gas pipe which extends through  
the lower rear of the appliance has 3/8-inch male  
pipe thread.) An individual manual shutoff valve  
must be installed within 6 feet of the dryer in  
accordance with the National Fuel Gas Code ANSI  
Z223.1.  
*27³⁄₄"  
*26"  
(66cm)  
(70.5cm)  
29"  
29"  
(73.66cm)  
(73.66cm)  
B
A
22³⁄₄"  
(57.8cm)  
43³⁄₈"  
C. Wided Opening  
Side-Swing Door  
43³⁄₈"  
(110cm)  
(110cm)  
13³⁄₄"  
(34.9cm)  
D. Wide Opening  
Hamper Door  
*27³⁄₄"  
(70.5cm)  
*27³⁄₄"  
(70.5cm)  
29"  
(73.66cm)  
29"  
(73.66cm)  
* Most installations require a minimum 5-1/2”  
(14 cm) clearance behind the dryer for the  
exhaust vent with elbow. See Installations  
Instructions, “Venting Requirements.”  
C
D
Electrical: A four-wire or three-wire, single  
phase, 120-volt, 60 Hz, AC-only, electrical supply  
is required on a separate 15 or 20 amp circuit,  
fused on both sides of the line. A time-delay fuse  
or circuit breaker is recommended.  
RECESSED AREA AND CLOSET INSTALLATION  
Exhaust venting: Exhaust your dryer to the  
outside. Four-inch diameter vent is required. Rigid  
or flexible metal exhaust vent must be used. Do  
Not use plastic or metal foil vent. Exhaust outlet  
hood must be at least 12 inches from the ground  
or any object that may be in the path of the  
exhaust.  
3"  
(7.6 cm)  
For closet installation  
with a door, minimum  
ventilation openings in  
14" max.  
(35.6cm)  
48 in. 2  
(310 cm2 )  
18"  
the top and bottom of  
(45.7 cm)  
the door are required.  
Louvered doors with  
equivalent air openings  
are acceptable.  
24 in.2  
3"  
(7.6 cm)  
(155 cm2 )  
1"  
(2.5 cm)  
29"  
(73.66 cm)  
5¹⁄₂"  
(14 cm)  
1"  
1" 27³⁄₄"  
(2.5 cm)(2.5 cm)(70.5 cm)  
B
C
A
A. Recessed area  
EXHAUST VENTING  
B. Side view - closet or confined area  
C. Closet door with vents  
4"  
(10.2 cm)  
Box hood style  
1. Select the route that will provide the straightest and most direct path outdoors. Plan  
the installation to use the fewest number of elbows and turns. When using elbows or  
making turns, allow as much room as possible. Bend vent gradually to avoid kinking.  
Avoid 90° turns.  
4"  
(10.2 cm)  
2.5"  
(6.4 cm)  
4"  
(10.2 cm)  
Angled style  
Louvered style  
Vent Length Chart  
2. Determine vent length.  
The maximum length of the exhaust system depends upon:  
• The type of vent (rigid metal or flexible metal).  
• The number of elbows used.  
• Type of hood.  
See the exhaust vent length chart that matches your hood type for the maximum vent  
lengths you can use.  
3. Determine the number of elbows you will need.  
IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.  
In the column listing the type of metal vent you are using (rigid metal or flexible metal),  
find the maximum length of metal vent on the same line as the number of elbows.  
Number of  
90° turns  
or elbows  
Type of  
vent  
Box or  
Louvered  
hoods  
Angled  
hoods  
0
1
2
3
4
Rigid metal  
64 ft (20 m)  
58 ft (17.7 m)  
28 ft (8.5 m)  
Flexible metal 36 ft (11 m)  
Rigid metal  
Flexible metal  
54 ft (16.5 m)  
31 ft (9.4 m)  
48 ft (14.6 m)  
23 ft (7 m)  
Rigid metal  
Flexible metal 27 ft (8.2 m)  
44 ft (13.4 m) 38 ft (11.6 m)  
19 ft (5.8 m)  
Rigid metal  
Flexible metal 25 ft (7.6 m)  
35 ft (10.7 m) 29 ft (8.8 m)  
17 ft (5.2 m)  
Rigid metal  
Flexible metal 23 ft (7 m)  
27 ft (8.2 m)  
21 ft (6.4 m)  
15 ft (4.6 m)  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. 8562584  
05-27-04  
 

QSC Audio Stereo Amplifier EX 800 User Guide
Reebok Fitness Home Gym RBEL99062 User Guide
Renesas Network Card PLQP0144KA A User Guide
Rinnai Water Heater 24e User Guide
Roland Musical Instrument HP 7 User Guide
Samsung CRT Television TXP1430F, TXP1634F, TXP2022 User Guide
Samsung Microwave Oven CE745GR User Guide
Samsung Satellite TV System SH 3000 User Guide
Sears Water Dispenser 62534929 User Guide
SECO LARM USA Security Camera EV 122C FVA3Q User Guide