Ruud Water Heater PH20V40F User Guide

®
Pacemaker  
Gas Water Heaters  
Available in 29, 38, 40 and 50 Gallon Tall – 30, 40 and 50 Gallon Short Gas Models  
6-Year Limited Tank and Parts Warranty*  
With ProtectionPlusthe 6-Year Limited Tank Warranty Becomes 10 Years!  
Guardian System™  
High Altitude Compliant  
One-of-a-kind air/fuel shut-off device offers double  
protection  
Maintenance free – no filter to clean  
Standard replacement parts  
All models are certified for applications up to 6,000  
feet above sea level. Some models are certified up to  
10,200 feet above sea level. Check factory for listings  
Plus…  
Get  
Environmentally Friendly Burner  
Brass drain valve and temperature and pressure relief  
valve are included  
4 MORE YEARS  
Low NOx design for low nitrous oxide emissions  
with ProtectionPlus  
Self-Cleaning  
Meets or exceeds National Appliance Energy  
Conservation Act (NAECA) requirements  
EverKleenpatented system fights sediment build-up  
Reduces fuel costs  
H
E
High Efficiency Models Feature:  
Provides more hot water  
High performance and lower operating cost  
Easy to Light  
Compliant with many gas utility incentive programs  
No matches required  
Energy Efficient  
*See Residential Warranty Information Brochure  
for complete warranty information.  
More hot water at low operating cost  
®
Longer Life  
Energy Factor and Average Annual Operating  
Costs based on D.O.E. (Department of Energy)  
test procedures. D.O.E. national average fuel rate  
Patented magnesium anode rod design incorporates a  
special resistor that protects the tank from rust  
natural gas $1.218/therm; LP $1.87/gallon  
.
DESCRIPTION  
FEATURES  
ROUGHING IN DIMENSIONS (SHOWN IN INCHES)  
ENERGY INFO.  
HT. TO  
GAS  
CONN.  
D
WATER  
CONN.  
CNTR.  
F
HT. TO  
SIDE  
T&P  
G
T
Y
GAS INPUT IN  
THOUS. BTU/HR.  
RECOVERY IN  
G.P.H. 90° RISE  
FIRST HOUR  
DEL. G.P.H.  
NAT.  
HT. TO  
VENT  
A
TANK  
HT.  
B
VENT  
SIZE  
E
WATER  
CONN.  
H
SHIP.  
WT.  
(LBS)  
ENERGY  
FACTOR  
NAT.  
AVG. ANN.  
OPER. COST  
NAT.  
GAL.  
CAP.  
DIAM.  
C
P
E
MODEL NUMBER  
NAT.  
LP  
34  
36  
30  
NAT.  
LP  
40  
50  
29  
40  
40  
38  
50  
50  
50  
30  
40  
40  
50  
PH2R40-40F  
40  
40.4 34.3  
40.4 36.4  
32.3 30.3  
68  
83  
50  
67  
73  
68  
90  
83  
83  
50  
72  
72  
84  
63-1/4  
62-1/4  
59-3/4  
61-1/2  
61-3/4  
61-1/2  
61-1/2  
61-1/2  
62  
59-3/4 21  
58-3/4 23  
14-1/2  
14-1/2  
3
3
3
3
3
3
3
3
4
3
3
3
3
8
8
8
8
8
8
8
8
8
8
8
8
8
53-1/2  
52-1/2  
50-3/4  
53  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
3/4  
135  
165  
100  
120  
120  
125  
130  
150  
150  
98  
0.62  
0.62  
0.62  
0.59  
0.59  
0.60  
0.58  
0.58  
0.58  
0.61  
0.59  
0.59  
0.59  
$294  
$294  
$294  
$309  
$309  
$304  
$315  
$315  
$315  
$299  
$309  
$309  
$309  
H
E
TALL  
PH2R50-40F  
P2-30F  
40  
32  
36  
38  
40  
38  
40  
50  
30  
36  
40  
40  
56-3/8 16-1/8 14-1/2  
58 17-3/4 14-1/2  
P40-36F1  
P2-40F1  
36.4  
32  
34  
36  
36  
38.4 32.3  
40.4 34.3  
38.4 36.4  
40.4 36.4  
58-3/8 18-1/8 14-1/2  
57-3/4 19-3/4 14-1/2  
58-1/4 20-1/8 14-1/2  
52-1/4  
52-1/4  
51-3/8  
52-1/2  
52-1/2  
40-1/4  
42-3/4  
44  
T
A
L
L
PH2-40F  
P2-50F1  
PH2-50-40F  
PH2-50-50F  
P2-30S-30F  
P2-40SF  
58  
58  
21-3/4 14-1/2  
21-3/4 14-1/2  
50.5  
30.3  
49-3/4  
52-3/4  
53-7/8  
54-1/4  
46-1/4 19-3/4 14-1/2  
49-3/8 20-1/8 14-1/2  
50-1/2 20-1/8 14-1/2  
49-3/4 22-1/4 14-1/2  
S
H
O
R
T
34  
36  
36  
36.4 34.3  
40.4 36.4  
40.4 36.4  
130  
130  
158  
PH2-40SF  
PH50SF  
44  
SPECIFY LP GAS WHEN ORDERING. Add “P” suffix to the model number. Example: PH2R40-40PF.  
• For SCAQMD rule 1121 compliance models (California only), add “SQ” suffix to the model number. Example: PH2R40-40FSQ.  
Ruud Guardian System Features…  
FLUE  
ANODE ROD  
H
H
HOT  
COLD  
WATER  
CONNECTION  
WATER  
CONNECTION  
Exclusive Combustion  
Shut-off System  
F
E
Flame Arrestor Plate  
Maintenance Free  
3/4" N.P.T.  
RELIEF  
Should a spill incident occur, the Guardian  
System shuts off the gas supply and the air  
supply preventing a sustained vapor burn in  
the combustion chamber.  
A specially-designed flame arrestor  
prevents ignition of vapors outside the  
combustion chamber.  
Superior air filtration prevents the  
flame arrestor from becoming clogged  
by lint, dust and oil.  
VALVE  
OPENING  
C
These units are designed to meet or exceed ANSI  
(American National Standards Institute) requirements and  
have been tested according to D.O.E. test procedures and  
meet or exceed the energy efficiency requirements of  
NAECA, ASHRAE standard 90, ICC Code and all state  
energy efficiency performance criteria for energy  
consuming appliances.  
A B  
1/2"  
G
Y E A R L I M I T E D  
TANK WARRANTY  
D
BECOMES  
For more details, see form 101-7.  
6
10  
Before purchasing this appliance, read important energy  
cost and efficiency information available from your supplier.  
In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice.  
Ruud Water Heating • 101 Bell Road, Montgomery, Alabama 36117-4305 • www.ruud.com  
PRINTED IN U.S.A  
07/08 WP  
FORM NO. 101R-6 Rev. 11  
 

Q See Medical Alarms QSTD5304 User Guide
Quatech Network Card DSCLP SSCLP 100 User Guide
RCA DVD Player RC5227P User Guide
Remington Power Tools Trimmer RM2510 User Guide
Ricoh Video Gaming Accessories G800SE User Guide
Rival Slow Cooker SCN10715 User Guide
Roper Range FGP305K User Guide
Ryobi Saw TS1302 User Guide
Samson Headphones DK700 User Guide
Sanyo Car Satellite TV System DP42647 User Guide