When setting sensitivity, make sure the room's environment is as close as
possible to what it will be when the ENFORCER 190/190S is in use. For
instance, if the curtains are usually closed at night when the alarm is
armed, then set sensitivity with the curtains closed. If a window in the
room is left opened, then set the sensitivity with window open. The
sensitivity should always be retested when the environment of the room
changes, such as when furniture is moved.
OPERATING THE ENFORCER 190 / 190S
MOUNTING THE DETECTOR
It therefore should be mounted in a location within which every glass
window and door to be protected is found. For greatest security, attach to
the wall or ceiling, using screws instead of double-sided foam tape. For
larger areas, two or more units can be used without fear of interfering with
each other.
Depending on the type of glass, sensitivity is different when set by tapping
the inside or outside of the window with a ruler. For best results,
tap the inside of the window.
SETTING THE SENSITIVITY
The ENFORCER 190/190S includes SECO-LARM's unique patented
Yellow turbulence LED. This LED flashes when environmental noise is high
enough to cause false alarms, thereby allowing instant sensitivity setting
without the use of a special external test meter.
NOTE: DO NOT SET SENSITIVITY ANY HIGHER THAN NECESSARY TO
PROTECT THE GLASS IN THE DETECTOR'S RANGE. SETTING
SENSITIVITY HIGHER THAN NEEDED INCREASES THE
CHANCE OF FALSE ALARMS WITHOUT INCREASING
PROTECTION. LEAVING A DOOR OR WINDOW OPEN WILL
ALSO INCREASE THE CHANCE OF FALSE ALARMS.
To set sensitivity, hold a thin flexible plastic ruler flat against a glass
window within the unit's protection range.
Pick up one end of the ruler while holding
the other end down, and then let the ruler
TAMPER-PROOFING CASE
snap against the glass window. This
For extra protection, the ENFORCER 190/190S is equipped with an
N.C. Tamper Switch to protect against opening or breaking of the
case.
should cause the Yellow LED to come ON,
but the Red LED should not light. If the
Red LED comes ON with a slight snap, the
ENFORCER 190/190S may be too
MIN
MAX
INSTALLATION
sensitive, and the sensitivity control should
be turned counterclockwise with a small
flat or phillips screwdriver. If the Yellow
LED does not come ON, sensitivity should
SCREW TERMINALS:
be increased by turning the control clockwise. Continue snapping the ruler
on the window until the Yellow LED comes ON but the Red LED does not.
Repeat this process with each window to ensure the ENFORCER 190/
190S is set for every pane of glass.
#7: N.C. TAMPER OUTPUT
#6: COMMON TAMPER OUTPUT
#5: COMMON GROUND
#4: 12VDC
When the correct sensitivity is found using the above procedure, determine
whether the sensitivity is high enough to trigger the alarm by snapping the
ruler harder to simulate a break-in. If the Red LED does not come ON, the
sensitivity must be increased.
#3: DRY RELAY N.O.*
#2: DRY RELAY COMMON*
#1: DRY RELAY N.C.*
NOTE: For applications within this temperature range the sensitivity will be
stable. If the temperature should drop below -14°F (-10°C), the
sensitivity of the ENFORCER 190/190S will increase, and the
sensitivity setting will need to be decreased. If the temperature
should rise above 122°F (50°C), the sensitivity of the
ENFORCER 190/190S will decrease, and the sensitivity setting will
need to be increased.
* For N.O. output, use Terminals 2 and 3
For N.C. output, use Terminals 2 and 1
|