ENFORCER®
SK-910 SERIES
RF RECEIVERS
Model
SK-910R ...............One-channel receiver, 315MHz
SK-910RL .............Low-voltage, one-channel receiver, 315MHz
SK-910R2 .............Two-channel receiver, 315MHz
SK-910R-4............One-channel receiver, 433.92MHz
SK-910RL-4 ..........Low-voltage, one-channel receiver, 433.92MHz
SK-910R2-4..........Two-channel receiver, 433.92MHz
SECO-LARM®
Mode Switch Operation (one per channel)
•
•
Learn mode — Press and hold the switch for three seconds.
Clear memory — Press three seconds, then when the LED starts flashing, press again for three seconds to
delete all previously learned codes.
•
•
Reset latched output — If this channel was programmed for latch output, once the relay is turned on with a
transmitter button, press the mode switch to turn the relay off.
Memory Display — Press and release the mode switch to show number of codes stored. LED will flash a number
of times to correspond to the number of codes stored.
LED Indication (one per channel)
•
•
•
•
Steady on — Senses signal from a transmitter button whose code was already learned.
Fast flash — In the code-learning mode.
One flash — A transmitter button code was learned.
Two flashes — All previously learned transmitter button codes were deleted.
Typical Applications:
Positive Output:
12VDC receiver power driving a 12VDC apliance:
COM
NC
NO
-
Positive Power Source
COM
NC
Positive Power Output
Power for SK-910R
NO
-
12VDC O/P
GND
Power for SK-910R
}
}
+
+
+12VDC
12VDC receiver power input, 24VAC output driving a motor
Negative Output:
24VAC(1) Input
Negative Power Source
COM
NC
NO
-
COM
NC
NO
-
24VAC(2)
2
Motor
1
24VAC(1) Output
GND
Negative Power Output
Power for SK-910R
+12VDC
}
General Specifications
+
+
Operating Frequency:
315 MHz (SK-910R, SK-910RL, SK-910R2)
433.92 MHz (SK-910R-4, SK-910RL-4, SK-910R2-4)
Memory Capacity:
Operating Voltage:
15 transmitter button codes per channel
11VDC ~ 24VDC or 11VAC ~ 24VAC
5VDC ~ 13VDC (SK-910RL / SK-910RL-4 only)
Operating Current:
8 mA @ 12VDC (standby)
30mA/channel @ 12VDC (activated)
70mA @ 6VDC (activated), (SK-910RL / SK-910RL-4 only)
Relay Contact Rating:
Connectors:
Form ‘C’ type; 10A @ 24VDC or 120VAC per channel
Screw Terminals, +, –,
with N/O, N/C, and COM per channel
Dimensions:
3.25” x 2.7” x 1.1” (83 x 68 x 27.5 mm)
Compatible Transmitters
315 MHz
433.92MHz
SK-919TD1S 1-button, Fixed Code
SK-919TD2A 2-button, Fixed Code
SK-939TS1S 1-button, Fixed Code
SK-939TS2A 2-button, Fixed Code
SK-937TS2A 2-button, Code Hopping
SK-937TS3A 3-button, Code Hopping
SK-917T3A
SK-917T2A
3-button, Code Hopping
2-button, Code Hopping
The SECO-LARM policy is one of continual development and improvement.
For this reason, SECO-LARM reserves the right to change specifications without further notice.
SECO-LARM® U.S.A., INC.
16842 Millikan Avenue
Irvine, CA 92606
Telephone
(800) 662-0800
(949) 261-2999
Fax
(949) 261-7326
FILE: TE-10, C:\DTP\MANUAL\MUK910R2.P65 APR2001
ORDER PART# 762-091-4 (904)
|
Radio Shack Cordless Telephone 43 3571 User Guide
Regency Indoor Fireplace P40 LP User Guide
Remington Trimmer BS1812A User Guide
Ricoh Projector PJ WX4130 User Guide
Rosewill Switch KVMRKV 4UC User Guide
Samson Headphones 350 User Guide
Samson Speaker D412 User Guide
Samsung Projection Television HL R6767W User Guide
Samsung Washer B1113J B913J User Guide
Sanyo Battery Charger HR 4 5SCU User Guide