SECO LARM USA Switch SR 2224 C5 User Guide

®
ENFORCER  
Relay Module  
SR-2224-C5  
Features:  
Two separate sets of Form-C dry contacts.  
Perfect for a variety of general switching purposes.  
Can be connected for load switching, dry contact, latching  
output, reverse polarity, line seizure, and other uses.  
6/12/24 VDC operation, programmable by on-board  
jumpers.  
Red LED indicates relay is energized.  
Large terminal blocks for easy installation.  
Small size, easily fits inside alarm panel enclosures  
or other hidden areas.  
Connection Diagram  
Foam mounting tape included.  
Two separate sets of Form-C contacts  
Input terminals to energize relay  
Specifications:  
Model Number:  
Relay type:  
SR-2224-C5  
DPDT, Form-C dry contacts  
5A @ 250VAC/30VDC  
Relay contact ratings:  
Programmable 6/12/24VDC,  
default at 12VDC  
Supply Voltage:  
Current draw:  
70mA @ 12-24VDC  
100mA @ 6VDC  
6V 12V 24V  
JP1 ON ON OFF  
JP2 ON OFF OFF  
Preset 12V  
Minimum pull voltage +/- 20% of operating voltage  
2.76" x 1.89" x .79"  
(70 x 48 x 20mm)  
Size  
Red LED - lights to show  
relay is energized  
2 Jumpers to  
program  
input voltage  
(6,12,24V)  
Weight  
1.94 oz. (55 g)  
Foam tape (included)  
Mounting method:  
®
®
ENFORCER  
Power Supplies  
Four Models to Choose From  
ENFORCER  
Timer Modules  
SA-025  
Switch selectable (see chart below) DC voltage output.  
Regulated and filtered output voltage.  
Triggered by positive voltage (+DC), closure of dry contact, or  
opening of dry contact.  
Switches to backup battery automatically in case of power loss.  
Short circuit protection.  
Built-in backup battery charger.  
Set from 1 sec. to 60 min.  
Relay programmable to activate at start or end of timing cycle.  
Relay programmable for pulse (flash) activation.  
Built-in reset function.  
Model #  
Voltage (DC)  
6,12  
Current  
1.5A  
Current (peak)  
Form-C relay, contacts rated 8A @ 120VAC/24VDC.  
LED indicator.  
12/24VDC (auto sensing).  
Low  
Power input  
Current drain  
Relay type  
ST-1206-1.5A  
ST-2406-2A  
ST-2406-3A  
ST-2406-5A  
2.0A  
2.0A  
3.0A  
5.0A  
12/24VDC (auto sensing).  
Low current drain.  
6,12,24  
6,12,24  
6,12,24  
1.5A  
Form-C relay  
2.5A  
7
1
2 /8" x 2 /2" (73 x 63 mm).  
Contact ratings 8A @ 120VAC/24VDC.  
4.0A  
SECO-LARM® U.S.A., Inc.  
16842 Millikan Avenue, Irvine, CA 92606  
Tel: 1-800-662-0800 (Domestic U.S. & Canada) Tel: 1-949-261-2999 (California &international)  
RelayModuleb.p65  
 

RCA Headphones TVP100 User Guide
Regency Indoor Fireplace P121 User Guide
Ricoh Printer SP 311DNw User Guide
RIDGID Saw AC9940 User Guide
Samsung Cell Phone 635753466201 User Guide
Samsung Home Theater System HT DS140 User Guide
Samsung Security Camera SNB 3000P User Guide
Seagate Computer Drive ST980313AS User Guide
Sears Air Conditioner 53DS900077 User Guide
SECO LARM USA Security Camera EV 1323B12DW User Guide