State Industries Water Heater Commercial Electric Water Heater User Manual

C O M M E R C I A L  
PATRIOT  
LIGHT-DUTY  
COMMERCIAL ELECTRIC WATER HEATERS  
Designed for use as recovery heaters for  
light-duty hot water supply service.  
Patriot PCE water heaters are available  
with tank capacities from 6 through 119  
gallons. They can be installed for non-  
simultaneous and single element operation  
(maximum input up to 6 KW), or for  
simultaneous dual-element operation  
(maximum input up to 12 KW).  
• Manual reset high temperature cutoff  
per element (dual-element models)  
• Factory wired for non-simultaneous  
operation; easily converted to simulta-  
neous operation  
Glass-Lined Tank with  
Anode Rod  
• Provides long-lasting protection against  
corrosion  
Zinc-Plated Copper Sheath  
Heating Elements Standard  
Maximum Hydrostatic Working  
Pressure: 150 psi  
• Medium watt density design disperses  
element temperature over larger  
surface contact area to minimize scale  
buildup, maximize efficiency and pro-  
long element life  
Meets or exceeds the thermal  
efficiency and/or standby loss  
requirements of the U.S.  
Department of Energy and current  
edition of ASHRAE/IESNA 90.1  
• Element options from 1.5 KW to 6  
KW (non-simultaneous or simultane-  
ous operation), recoveries from 6 gph  
to 49 gph at 100°F rise  
Other Patriot™ PCE  
Series Features  
Standard Voltages for  
Easy Installation  
• Simplified, color-coded circuitry for  
ease of service  
• 120V, 277V single-phase, and 208V,  
240V and 480V unbalanced 3-phase  
delta  
• Bonderized undercoat on cabinet with  
baked enamel finish  
Top inlet and outlet openings  
• Foam insulation  
• Easily converted to single-phase at ter-  
minal block (except for 208V with  
6000 watt elements  
• Drain valve  
• Single-element heater, single-phase only  
(see chart for dual-element options)  
• UL-approved field conversion program  
Factory-Installed  
Terminal Block  
Three-Year Limited Tank  
Warranty  
• Provides electrical service to heater and  
connects to block  
• Consult written warranty shipped with  
water heater, or contact State for  
complete information  
Factory-Wired Controls  
Temperature control (adjustable from  
110°F to 170°F on single-element;  
120°F to 180°F on dual-element models)  
For more information on State® contact:  
State Water Heaters  
500 Tennessee Waltz Parkway, Ashland City, TN 37015  
800-365-0024 Toll-free USA  
SCESS00106  
August 2008R  
Page 1 of 4  
©2007 State Water Heaters Company  
 
TOP VIEW  
PCE 6 10MSA, PCE 10 10MSA  
PCE 17 10MSA, PCE 20 10MSA  
ALTERNATE OUTLET  
OUTLET  
3/4" (FEMALE) NPT  
3/4"(FEMALE)  
NPT*  
3/4" NPT  
RELIEF VALVE  
OPENING  
A
B
C
ELECTRICAL  
CONNECTION  
INLET  
3/4" (FEMALE)  
NPT  
FRONT VIEW  
PCE 6 10MSA, PCE 10 10MSA  
PCE 17 10MSA, PCE 20 10MSA  
OUTLET  
3/4" (FEMALE)  
NPT  
OUTLET  
3/4" (FEMALE)  
NPT  
INLET  
3/4" (FEMALE)  
NPT  
INLET  
3/4" (FEMALE)  
NPT  
“D”  
“D”  
3/4" NPT  
RELIEF VALVE  
OPENING  
2 1/2"  
JUNCTION  
BOX  
JUNCTION  
BOX  
2 1/2"  
TOP VIEW  
PCE 30 20LSA, PCE 40 20LSA,  
PCE 50 20LSA  
TOP VIEW  
“B”  
“B”  
3/4" NPT  
RELIEF VALVE  
OPENING  
“A”  
“A”  
“C”  
DRAIN  
VALVE  
BRASS  
DRAIN  
VALVE  
3 3/4"  
3 3/4"  
FRONT VIEW  
PCE 30 20RTA – PCE 120 20RTA  
FRONT VIEW  
PCE 30 20LSA, PCE 40 20LSA,  
PCE 50 20LSA  
Page 3 of 4  
©2008 State Water Heaters Company  
SCESS00106  
August 2008R  
 
C O M M E R C I A L  
SUGGESTED SPECIFICATION  
The water heater(s) shall be State Patriot™ Model(s) ________, rated at _______ KW, _______ volts, _______ -phase, 60  
cycle AC. Water heater(s) shall be listed by Underwriters Laboratories and meet or exceed the thermal efficiency and/or standby  
loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1 shall be ________ gallon  
capacity with a recovery capacity of ______ GPH at a temperature rise of ______°F with ______/______ upper/lower element  
wattage. Heater(s) shall have 150 psi working pressure and be equipped with extruded high-density anode rod. All internal  
surfaces of the heater(s) exposed to water shall be glass-lined with an alkaline borosilicate composition that has been fused to  
steel by firing at a temperature of 1600°F. Electric heating elements shall be medium watt density with zinc-plated copper sheath  
or Incoloy sheath _______________.  
Each element shall be controlled by an individually mounted thermostat and high-temperature cutoff switch. The outer jacket  
shall be a baked enamel finish and provided with a full-size control compartment for performance of service and maintenance  
through a hinged front panel and shall enclose the tank with foam insulation.  
Electrical junction box with heavy-duty terminal block shall be provided (except on 120V and 277V [no junction box on  
PCE 6 10MSA thru PCE 20 10 MSA]). The drain valve shall be located in the front for ease of servicing. Heater tank shall  
have a 3-year limited warranty as outlined in the written warranty. Fully illustrated instruction manual will be included.  
For more information on State® contact:  
State Water Heaters  
500 Tennessee Waltz Parkway, Ashland City, TN 37015  
800-365-0024 Toll-free USA  
Page 4 of 4  
©2008 State Water Heaters Company  
SCESS00106  
August 2008R  
 

Shark Iron GI465 User Manual
Sharp Cash Register XEA 201 User Manual
Sonance Speaker A800D User Manual
Sony Camcorder 4 124 311 121 User Manual
Sony Home Theater System 4 178 247 141 User Manual
Sony Stereo Amplifier TA FB730R User Manual
Sony VCR SLV SE800G User Manual
StarTechcom Computer Drive PEXSAT34 User Manual
Sterling Home Theater Server 88200025400 User Manual
Sunrise Medical Mobility Aid nonee User Manual