Sunbeam’s Safety Precautions
Sunbeam are very safety conscious when
• Do not use an appliance for any purpose
other than its intended use.
• Do not place an appliance on or near a hot gas
flame, electric element or on a heated oven.
Do not place on top of any other appliance.
• Do not let the power cord of an appliance hang
over the edge of a table or bench top or touch
any hot surface.
designing and manufacturing consumer products,
but it is essential that the product user also
exercise care when using an electrical appliance.
Listed below are precautions which are essential
for the safe use of an electrical appliance:
• Read carefully and save all the instructions
provided with an appliance.
• Always turn the power off at the power outlet
before you insert or remove a plug. Remove
by grasping the plug - do not pull on the cord.
• Turn the power off and remove the plug
when the appliance is not in use and
before cleaning.
• For safety reasons and to avoid maintenance
by unskilled persons, some appliances are
‘sealed’ using tamperproof screws. Such
appliances should always be returned to the
nearest Sunbeam Appointed Service Centre
for adjustment or repair if required.
• Do not use your appliance with an extension
cord unless this cord has been checked
and tested by a qualified technician or
service person.
• Always use your appliance from a power
outlet of the voltage (A.C. only) marked
on the appliance.
• Close supervision is necessary when your
appliance is being used near children or
infirm persons.
• Never leave an appliance unattended while
in use.
• Do not operate any electrical appliance with a
damaged cord or after the appliance has been
dropped or damaged in any manner. If damage
is suspected, return the appliance to the
nearest Sunbeam Appointed Service Centre
for examination, repair or adjustment.
• For additional protection, Sunbeam
recommend the use of a residual current
device (RCD) with a tripping current not
exceeding 30mA in the electrical circuit
supplying power to your appliances.
• Do not immerse the appliance in water
or any other liquid unless recommended.
• Young children should be supervised to ensure
that they do not play with the appliance.
If you have any concerns regarding the performance and use of your appliance,
Ensure the above safety precautions are understood.
1
Sunbeam’s Safety Precautions
• This heater becomes hot during use. To avoid
burns, do not let bare skin touch hot surfaces.
If provided, use handles when moving this
heater. Keep combustible materials such as
furniture, pillows, bedding, papers, clothes and
curtains at least 3 feet (90cm) away from the
front of the heater and keep them away from
the sides and rear.
• Extreme caution is necessary when any heater
is used by or near children or invalids and
whenever the heater is left unattended.
• Always unplug the heater when not in use.
• Do not use outdoors.
• Do not locate the heater immediately below a
socket outlet.
• Do not use this heater in the immediate
surrounds of a bath, shower, laundry area or
swimming pool.
• Do not insert or allow foreign objects to enter
any ventilation or exhaust openings as this may
cause electric shock or fire, or damage to the
heater.
• To prevent a possible fire, do not block air
intakes or exhaust in any manner. Do not use
on soft surfaces, such as beds, where opening
may become blocked.
• Do not run the cord of the heater under
carpeting. Do not cover the cord with throw
rugs, runners or other floor coverings. Arrange
the cord away from traffic areas where it will
not be tripped over.
• A heater has hot and arcing or sparing parts
inside. Do not use it in areas where petrol,
paint or flammable liquids are used or stored.
Important instructions – retain for
future use.
If you have any concerns regarding the performance and use of your appliance,
Ensure the above safety precautions are understood.
2
Sunbeam’s Total Safety System
Safety auto shut off
Thermal back-up fuse
Your Sunbeam Micro Furnace Heater is
equipped with a safety system that detects
any abnormally high temperatures within
the heater and automatically shuts it off to
prevent overheating. This first stage of the
safety system requires the user to manually
reset the heater for it to resume operation.
In addition to this automatic cut off, your
heater contains a thermal back-up fuse to
provide additional back-up protection. If
the heater is in an overheat situation, the
back-up fuse will open, stopping the power
flow to the ceramic heating discs and fan.
This fuse cannot be reset, so in the event
that the back-up fuse is activated, the
heater will need to be replaced.
For instructions on how to reset your
heater, see page 6.
3
Features of your 2000W
Micro Furnace heater
Electronic thermostat
The electronic thermostat works with the
external temperature sensor to maintain your
selected temperature. It constantly monitors
the room’s temperature and continuously
varies the heat output to maintain your
desired comfort level.
Ceramic disc heating system
Each ceramic disc contains 1200 honeycomb
shaped holes that heat all of the air that
passes through them, generating up to 40%
more warmth than conventional coil or
ceramic chip heaters.
External temperature sensor
The temperature sensor is located at the rear
of the unit, not inside the heater itself, to
ensure accurate temperature measurement.
It detects even the slightest change in the
room’s temperature, and communicates
this to the electronic thermostat.
Tip over cut-out
Should your heater accidentally be
knocked over, the instant tip over cut will
automatically interrupt power to the heating
element and fan. The heater will not resume
operation until it is replaced in the upright
position.
Power/Mode light
The power light illuminates amber to indicate
that the heater is connected to the power
outlet and is set to AUTO mode. It
illuminates green when the heater is set to
MANUAL mode.
4
Temperature light
The temperature light illuminates red once
the selected temperature level is reached.
Removable dust filter
The filter collects dirt and dust from the air
circulating through the heater. It is
removable for easy cleaning.
Mode/Standby button
Use the standby button to select the desired
operating mode. Pressing the standby button
once selects the AUTO mode, twice selects
the MANUAL mode, and pressing a third
time selects the STANDBY mode.
AUTO mode
Select AUTO mode for thermostatically
controlled operation.
MANUAL mode
Select MANUAL mode for constant heat
output at your desired heat level, from
setting 1 to 5.
LED screen
The LED screen displays the ambient room
temperature, and the selected setting during
adjustment.
+ and - buttons
Use the + and – buttons to adjust the
selected temperature when in AUTO mode,
or to select the desired heat setting when in
MANUAL mode.
5
Features of your 1500W
Micro Furnace heater
Mode dial
Use the mode dial to select the desired operating
mode: FAN to circulate cool air; HEAT to operate the
heater, or OFF.
Thermostat dial
Use the thermostat dial to select the desired
temperature, from 10°C to 27°C. Once the selected
temperature level is reached, the thermostat will
contantly adjust the heat output to maintain it.
Tip over cut-out
Should your heater accidentally be knocked over, the
instant tip over cut will automatically interrupt power
to the heating element and fan. The heater will not
resume operation until it is replaced in the upright
position.
Electronic thermostat
The electronic thermostat constantly monitors the
room’s temperature and adjusts the heat output to
maintain your selected temperature.
6
Power light
Illuminates to indicate that the heater is
connected to the power outlet and is
switched on.
Temp limit light
Illuminates to indicate that the room has
reached the selected temperature.
Removable dust filter
The filter collects dirt and dust from the air
circulating through the heater. It is
removable for easy cleaning.
Ceramic disc heating
Each ceramic disc contains 1200
honeycomb shaped holes that heat all of the
air that passes through them, generating up
to 40% more warmth than conventional coil
or ceramic chip heaters.
7
Using your heater
MF2000 Micro Furnace Ceramic Disc Heater
1. Place the heater on a flat level surface,
approximately 1 metre from any wall or
other objects such as furniture, curtains,
plants or combustible material, and ensure
that the air intake and outlet are clear of
obstructions.
Note: For most efficient heating, place the
heater on the floor where the air is cooler,
near an outside door, the bottom of a
staircase, or where colder air is most likely
to be entering the room.
2. Insert the plug into a 230-240V power
outlet and turn the power on. The red
power light will illuminate and the screen
will display the ambient room temperature.
3. Press the Standby button to select the
desired operating mode. Press it once to
select the AUTO mode, or twice to select
MANUAL mode.
The selected temperature (in degrees
celsius) will flash several times to indicate
that it is set. The screen will then return
to displaying the current room
temperature. The thermostat will continue
to vary the heat output to maintain your
selected temperature.
5. In MANUAL mode, use the + and –
buttons to select the desired heat setting,
from H1 to H5. The selected setting will
flash several times to indicate that it is
set. The screen will then return to
displaying the room temperature. The
heater will operate constantly at the
selected heat level, without monitoring the
room temperature.
6. To switch between operating modes or turn
the heater off, press the standby button.
7. Switch the power off at the power outlet
and unplug the heater when not in use.
4. In AUTO mode, use the + and – buttons to
select the desired temperature.
8
Using your heater (continued)
MF1500 Micro Furnace Ceramic Disc Heater
1. Place the heater on a flat level surface,
approximately 1 metre from any wall or
other objects such as furniture, curtains,
plants or combustible material, and ensure
that the air intake and outlet are clear of
obstructions.
Note: For most efficient heating, place the
heater on the floor where the air is cooler,
near an outside door, the bottom of a
staircase, or where colder air is most likely
to be entering the room.
3. To operate the heater, select HEAT on
the mode dial. Rotate the thermostat dial
to select the desired temperature setting.
Once the selected temperature level has
been reached, the thermostat will
constantly vary the heat output to
maintain it.
4. To operate the fan, select FAN on the
mode dial. Rotate the thermosat dial to
minimum.
5. To switch the heater off, select OFF on the
mode dial.
6. Switch the power off at the power outlet
and unplug the heater when not in use.
2. Insert the plug into a 230-240V power
outlet and turn the power on. The power
light will illuminate.
Care and cleaning
Ensure the heater is switched off and
disconnected from the power outlet before
cleaning.
Cleaning the dust filter
The dust filter collects dirt and dust from the
air circulating through the heater.
Carefully wipe the exterior of the heater with
a soft damp cloth and dry thoroughly.
To clean the filter, remove from the unit and
rinse under warm water. Allow to dry
completely before replacing on the heater.
Storage
Store your heater in a cool dry place when
not in use. Store the heater in its carton if
possible.
9
Consumer Hotline
Australia
1800 025 059
New Zealand
(09) 912 0747
is a registered trademark of Sunbeam
Corporation Limited.
is a registered trademark of Pelko Electric
Company and is used under licence by Sunbeam
Corporation Limited.
Made in China. Due to minor changes in design or
otherwise, the product you buy may differ from the one
shown in this leaflet.
Backed by Sunbeam‘s 3 Year Replacement Guarantee and
National Service Network.
© Copyright. SUNBEAM CORPORATION LIMITED 2004.
(INCORPORATED IN N.S.W.) A.C.N. 000 006 771
Sunbeam Corporation is a division of GUD Holdings Ltd.
For more information or advice on this or any other
contact the Sunbeam Consumer Service Line.
Australia 1800 025 059
New Zealand (09) 912 0747.
|