Toastmaster Food Warmer TMHPE User Manual

ELECTRIC HOTPLATES  
MODEL  
TMHPE,TMPHF  
Installation and  
Operation  
Instructions  
2M-Zꢀ2999 Rev. - Oct. ꢀ, 2009  
TMHPE  
TMHPF  
is a registerd trademark of Toastmaster, A Middleby Company. All rights reserved.  
 
GENERAL OPERATING INSTRUCTIONS  
CAUTION  
This equipment is designed and sold for commercial use only by personnel trained and  
experienced in its operation and is not sold for consumer use in and around the home nor for  
use directly by the general public in food service locations. For equipment to be used by the  
general public, please contact the factory.  
The Toastmaster models TMHPE & TMHPF Electric Hot Plates are equipped for the voltage  
indicated on the nameplate mounted on the front panel. This unit is designed to operate on  
alternating current (A.C.), two wire single phase service only.  
DO NOT CONNECT TO DIRECT CURRENT (D.C.).  
Total Connected Load:  
TMHPF:  
at 240 Volts, Wattage is 5,200  
at 208 Volts, Wattage is 3,900  
TMHPE:  
at 240 Volts, Wattage is 4,200  
at 208 Volts, Wattage is 3,ꢀ50  
INSTALLATION  
For your protection, we recommend that a qualified electrician install this appliance. The electrician  
should be familiar with electrical installations and your local electrical requirements. The  
external wiring should be in conduit or an approved type of flexible cable and of suitable size  
to carry the load. The supply circuit should be properly fused and equipped with a means  
of disconnecting as required by local electrical code. The body of the hot plate should be  
grounded (Do not ground to a gas supply pipe). The connections are made in this unit at the  
pigtail leads located in the junction box on the back of the unit. To gain access to the pigtail  
leads remove cover on junction box.  
LOCATE THE UNIT  
Do not install the unit closer than ꢀ inch from a side wall and/or closer than ꢀ inch from a rear wall.  
LEVELING UNIT  
Level unit by adjusting the (4) feet for accurate and perfect line up with other Toastmaster series units.  
CAUTION  
DO NOT INSTALL WITHOUT FEET.  
CAUTION  
USE ONLY FLAT BOTTOM PANS AND POTS! DO NOT USE RAISED BOTTOM UTENSILS  
OR BUCKETS! GOOD HEAT TRANSFER DEPENDS UPON GOOD CONTACT BETWEEN  
THE ELEMENT AND POT.  
NOTE: Using a ꢀ2” diameter or larger pan/pot may cause damage to the element or internal wiring.  
Such damages are not covered by warranty. Two (2) heating elements are used. For the TMHPF each  
element draws 2,600 Watts on 240 Volts and ꢀ,950 Watts on 208 Volts. For the TMHPE element  
draws 2,ꢀ00 Watts on 240 Volts and ꢀ,575 Watts on 208 Volts. Each element is controlled by an  
infinite position switch. The right control knob controls the rear cooking element and the left control  
knob controls the front cooking element. On “HI” the element delivers uninterrupted full heat. Between  
“LO” and “5” any desired amount of heat can be obtained between 6% and 60% of full heat.  
Signal lights are provided above the control knobs to give a visual check if either one or both heating  
units are turned on.  
 
CLEANING  
The exterior surfaces can be kept clean and attractive by regularly wiping with a clean soft cloth. Any  
discoloration can be removed with a non-abrasive cleaner.  
For model TMPHE, the heating elements may be raised for access to the drip pans, which may be  
removed for cleaning and the bottom pan may be removed by sliding pan forward.  
REPLACEMENT OF INFINITE CONTROL  
BE SURE POWER IS DISCONNECTED BEFORE ATTEMPTING TO SERVICE UNIT.  
ꢀ. Pull control knobs on front panel forward to remove.  
2. Remove 8 screws from front panel and tilt front panel forwards.  
3. Remove the nut that mounts the inoperative control and pull the control to the side.  
4. Remove one wire at a time from the inoperative control and connect at the same terminal  
on the new control. Carefully check to see that proper wires have been connected to the  
terminals of the control. See attached wiring diagram.  
5. Assemble new control to the front panel.  
MAINTENANCE AND REPAIRS  
Contact the factory or one of its representatives or a local service company for service or maintenance  
if required.  
2
 
Warranty Statement  
This warranty is effective on all Toastmaster equipment sold on or after July 1, 2006, and supersedes all  
previous warranties.  
Toastmaster warrants equipment that it manufactures to be free from defects in material and  
workmanship. Toastmaster’s obligation is limited to repairing or replacing, at Toastmaster’s option, without  
cost to the customer, any part found to be defective, as well as any labor or material expense required to  
replace the part.  
Length of Warranty  
This warranty is effective for a period of 18 months from the date of shipment from Toastmaster,  
or 12 months from the date of purchase by the end user, whichever is earlier.  
Exceptions  
This warranty is valid only for the original end user owner/operator of the equipment.  
This warranty does not apply to normal maintenance functions, including (but not limited to)  
improper operation, installation or the use of an improper utility supply.  
This warranty is valid only if the equipment is used in a commercial setting. The equipment  
is designed and constructed for commercial use by trained professionals only. Any use of the  
equipment in private or domestic applications immediately voids this warranty.  
This warranty does not apply to any parts, labor and material expenses for service that is not  
pre-approved and performed by a Toastmaster authorized service agent. Any such service  
immediately voids this warranty.  
This warranty does not apply to any parts, labor and material expenses associated with the  
installation of parts that are not factory-approved for use in the equipment. Any use of such  
parts immediately voids this warranty.  
This warranty is not valid if terms of payment have not been met.  
For warranty service on Pop-up toasters and light countertop equipment, an exchange program  
would supersede a service call. Please find Warranty Exchange Program’ authorization to  
follow. (http://www.toastmastercorp.com/filespdfcat/warranty_exchange_2008.pdf)  
Toastmaster reserves the right to change the design and specifications of this equipment or any related  
documentation at any time. The end user is not entitled to upgrades resulting from these changes.  
This warranty is exclusive and supersedes all other warranties for the equipment, both expressed and  
implied. There are no implied warranties of merchantability or of fitness for a particular purpose.  
The foregoing is Toastmaster’s sole and exclusive obligation and the end user sole and exclusive remedy  
for any action including breach of contract or negligence. In no event shall Toastmaster be liable for a sum  
in excess of the purchase price of the equipment, or for any prospective or lost profits of the end user.  
is a registerd trademark of Toastmaster, A Middleby Company. All rights reserved.  
3
 
1
2
5
4
6
8
7
9
10  
12  
13  
14  
3
11  
15  
16  
18  
20  
21  
19  
17  
22  
23  
24  
25  
26  
MODEL: TMHPE, TMHPF  
Electric Hotplates  
SK2433  
REV -  
9/1/09  
 
PARTS LIST  
October ꢀ, 2009, Rev. -  
TMHPE, TMHPF, Electric Hotplates  
MODEL  
Fig No.  
Part No  
2N-Y3301  
Description  
Qty Application  
1
2
3
4
5
6
7
ELEMENT  
2
2
4
2
2
2
2
TMHPF  
TMHPF  
TMHPE  
TMHPE  
TMHPE  
TMHPE  
TMHPE  
TMHPF  
TMHPE  
ALL  
I3-Z6169  
I3-Y7891  
I3-Y7822  
2N-Y7779  
2D-6470  
ELEMENT CLAMP  
CHAIN STRAIN RELF  
COVER, TERMINAL BLOCK  
ELEMENT,502 RNGE SURFACE  
PAN-REFLECTOR CHROMALOX  
RING-ELE ADAPTR R9R  
TOP, TMHPF  
2P-6468  
I8-Z12997  
I8-Z12998  
G3-Z5945  
I8-Z12996  
I2-Z6064  
G3-Y7788  
2C-Y2344  
2E-Y7327  
I2-Z6170  
I8-Z12995  
2A-Z0314  
I2-Z6178  
I3-Z6174  
2K-Z6183  
I2-Z6177  
I2-Z6172  
2J-6403  
8
1
TOP, TMHPE  
9
SIDE PANEL LT/RT  
SIDE LINER, LEFT  
WIRING COVER  
2
1
1
1
1
1
1
1
4
10  
11  
12  
13  
14  
15  
16  
17  
ALL  
TMHPE  
ALL  
COVER, HANDY BOX  
TERMINAL-GRND T&B  
HANDY BOX 4X2.125X2.125  
REAR PANEL  
ALL  
ALL  
ALL  
SIDE LINER, RIGHT  
FOOT, 4 IN DIE CAST  
DRAWER SLIDE  
ALL  
ALL  
TMHPE  
TMHPF  
ALL  
18  
1
BOTTOM PANEL  
19  
20  
21  
22  
23  
24  
25  
26  
BUSHING 1.125  
4
1
1
2
1
1
2
2
DRAWER  
TMHPE  
ALL  
CENTER WALL  
CONTROL-INFINITE 240V  
FRONT PANEL  
ALL  
I2-Z6179  
2M-Z12939  
2J-Y6690  
2R-Z13016  
ALL  
GRAPHIC PANEL, 12” HTPLT  
PILOT LIGHT 240V  
KNOB, T-STAT ELEC.  
ALL  
ALL  
ALL  
IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED  
INCLUDE MODEL AND SERIAL NUMBER  
PAGE  
OF  
Some items are included for illustrative purposes only and in certain instances may not be available.  
is a registerd trademark of Toastmaster, A Middleby Company. All rights reserved.  
 
 

Teledex Telephone Diamond 3 User Manual
Toshiba DVD Player SD 2710 User Manual
Toshiba Telephone CIX CTX QRG VB VERSION B1 User Manual
Troy Bilt Lawn Mower V809h User Manual
Troy Bilt Tiller 12190 3HP User Manual
VeriFone Table Top Game 1000SE User Manual
ViewSonic Projector PJD5123 User Manual
Vivotek Home Security System FD7130 User Manual
Vizio Flat Panel Television E190VA User Manual
Volvo Automobile VHD User Manual