R
Item no. 2005
TM
User's Manual
Slim Line 1250 Watt Power Inverter by Wagan Tech
USE R ’ S MANUAL — Please read before using this equipment.
_______________________________________________________________________________________________________________________
BAT T E R Y USE
SAFE T Y PR E CAUT ION
Do not open the case of the inverter. The high voltage
inside the unit is the same type of power as your
electrical outlets at home.
•
If you choose to connect the inverter directly to your
battery terminals, it is important to connect with right
from inverter to
of battery
of
polarity (connect
terminal and connect
battery terminal)
from inverter to
Do not let the cord of the inverter or any appliance’s cord
get wet.
CAUTION:
Do not operate the inverter in or around water. The
voltage of the unit makes electrical shock hazard if
operated in wet conditions.
THE FOLLOWINGS OPERATION WILL DAMAGE AND
VOID THE WARRANTY OF THE INVERTER:
•
•
REVERSE POLARITY BY CONNECTING THE
WIRES TO THE INCORRECT TERMINALS.
CONNECTING THE BATTERY CHARGER TO
REPLENISH BATTERY WITHOUT
Do not connect the AC inverter directly to another AC
power source.
DISCONNECTING THE INVERTER FIRST.
CONNECTING THE INVERTER TO POWER
SOURCE GREATER THAN 15-VOLT DC.
OPERATING THE INVERTER AND BATTERY IN
OR AROUND WATER.
Keep it away from children, the inverter produces power
just like your AC wall outlets at home and should be
treated seriously.
•
•
Allow at least 2 inch of clearance around the inverter for
airflow.
ME ASUR ING T HE AC V OL T AGE
If you operate the inverter in a moving vehicle, you need
to secure the inverter to prevent it from shifting around
while the vehicle is moving.
The output waveform of the AC inverter is a MODIFIED
SINEWAVE. To measure the AC output voltage, you
must use a TRUE RMS VOLTMETER.
If there is anything wrong with the inverter, disconnect all
of the power.
3
© 2003 Wagan Corporation.
All Rights Reserved.
Wagan and Wagan.com are trademarks used by Wagan Corporation.
Printed in China
Tech
Slim Line 1250 Watt Power Inverter by Wagan
USER’S MANUAL — Please read before using this equipment.
_______________________________________________________________________________________________________________________
T R OUBL E SHOOT ING
Condition
3.
Make sure that the antenna feeding your television
provides an adequate (“snow free”) signal and that
you are using good quality cable between the
antenna and the television.
S olution
Poor contact
Battery voltage is
too low
Clean contact parts thoroughly
Start the engine to recharge the
battery. Replace the battery if
needed.
4. Move the television as far away from the power
inverter as possible.
5. Keep the cables between the battery and the power
inverter as short as possible and twist them together
with about 2 to 3 twists per foot. This minimizes
radiated interference from the cables.
Shutdown on
overload
Reduce the wattage of inverter’s load
Thermal shutdown Allow the inverter to cool down by
reducing the load or turn it off for a
while.
Receptacle has no Check the receptacle wiring.
power
MAINT E NANCE
Very little maintenance is required to keep the inverter
operating properly.
HINTS
Adding E xtens ion Cord
DE SCR IPT ION
If you need extension cord, we recommend the use of an
extension cord between the AC output of inverter and
AC appliances. You may use up to 100 ft. of high quality
extension cord. A long cord will result in reduced output
power.
3000W Peak Power — allow you to power appliances
that require a large amount of initial (peak) power to
work (such as many TVs and motor-power equipments).
Low B attery Alarm — the inverter sounds an audible
alarm then turns itself off if the source battery becomes
too low.
B uzz in audio s ys tem
Some stereo systems and “boom boxes” will emit a
buzzing noise from their loudspeakers when operated
from the power inverter because the power supply in the
device does not adequately filter the modified sine wave
produced by the power inverter. The only solution is to
use a sound system that incorporates a higher quality
power supply.
Auto S hutdown/R es et Protection — the inverter
temporarily shuts itself down to protect itself from
overheating.
Overload/S hort Circuit Protection — the inverter
automatically turns itself off if the connected load is too
high or if it shorts.
Operating a TV
Picture tubes have a degaussing coil that uses a high
initial surge of power to light up the screen from a “cold
start”. If the TV does not start up on the first try, switch
ON the TV every 2 - 3 seconds until the screen comes
on. Sometimes, it may take 2-5 tries before starting.
Fus e — the inverter comes with fuse/s already installed
and can be changed if it is damaged.
Dual AC Outlets — allows you to power up to two
appliances at the same time.
Televis ion interference
Operating of the power inverter can interfere with
television reception on some channels. If this situation
occurs, the following steps may help to alleviate the
problem.
1. Make sure that the chassis ground lug on the back
of the power inverter is solidly connected to the
ground system of your vehicles.
2. Do not operate high power loads with the power
inverter while watching television.
4
© 2003 Wagan Corporation.
All Rights Reserved.
Wagan and Wagan.com are trademarks used by Wagan Corporation.
Printed in China
Slim Line 1250 Watt Power Inverter by Wagan Tech
USE R ’ S MANUAL — Please read before using this equipment.
_______________________________________________________________________________________________________________________
HE AT DISPE R SAL
The inverter generates heat while it is working. This is
not a malfunction. However, if the inverter gets too hot
while working, it will turn off by itself.
Position the inverter where air flows freely around it to
allow the heat to disperse.
The inverter’s thermal protection prevents it from
°
operating when its temperature exceeds 130 ± 10 F / 55
°
± 5 C.
SPE CIFICAT ION
Name
Input
Des cription
12V (10-15V) DC
115V AC
Output
Output frequency
Output waveform
Continuous power
Surge power
60 Hz
Modified Sine Waveform
1250 Watt
3000 Watt
Efficiency
Approx. 90 %
< 0.3 A
10.5 0.5 V DC
10 0.5 V DC
130 10 °F / 55 5 °C
No load current
Battery low alarm
Battery low shutdown
Alarm and thermal
shutdown
Internal DC fuse
External DC fuse
AC output socket
Power switch
Dimensions (LxWxH)
Net Weight
30 A
None
2 outlets of 3-prong
DC input ON/OFF control
15x8x3.3 in3
10 lb
NOT E
All specifications are typical at nominal line, half load,
and 77 °F / 25 °C unless otherwise noted.
Specifications are subject to change without notice.
5
© 2003 Wagan Corporation.
All Rights Reserved.
Wagan and Wagan.com are trademarks used by Wagan Corporation.
Printed in China
WAGAN Corp. Limited Warranty Registration Form
All WAGAN Corporation products are warranted to the original purchaser of this product.
Warranty Duration: This product is warranted to the original purchaser for a period of one (1)Year
from the original purchase date, to be free of defects in material and workmanship. WAGAN
Corporation disclaims any liability for consequential damages. In no event will WAGAN
Corporation be responsible for any amount of damages beyond the amount paid for the product
at retail. In the even of a defective item, please ship the item, prepaid, with a complete
explanation of the problem, your name, address and daytime phone number. WAGAN
Corporation will, at its option, replaces or repair the defective part. This warranty is void if the
product has been damaged by accident, in shipment, unreasonable use, misuse, neglect,
improper service, commercial use, repairs by unauthorized personnel or other causes not arising
out of defects in materials or workmanship. This warranty is effective only if the product is
purchased and operated in the USA and does not extend to any units which have been used in
violation of written instructions furnished.
Warranty Disclaimers: This warranty is in-lieu of all warranties expressed or implied and no
representative or person is authorized to assume any other liability in connection with the sale of
our products. There shall be no claims for defects or failure of performance or product failure
under any theory of tort, contract or commercial law including, but not limited to negligence,
gross negligence, strict liability, breach of warranty and breach of contract.
Warranty Performance: During the above one (1)Year warranty period, a product with a defect
will be replaced with a comparable model when the product is returned to WAGAN Corporation
with an original store receipt. The replacement product will be in warranty for the balance of the
one (1)Year warranty period.
Please activate my limited warranty for WAGAN Corp.1250 Watt AC to DC Power Inverter
Enclosed copy of original sales receipt.
Name
Mail Address
City
State, Zip Code
Item Purchased 1250 Watt AC to DC Power Inverter
Stores Name
Date of Purchase
Signature
Date
All WAGAN Corporation Products must be registered within (30) days of purchased to activate this warranty.
Mail the complete registration form, along with a copy of the original receipt to:
Attn: Customer Service
WAGAN Corporation
3589Yale Way
Fremont, CA 94538
c 2003 WAGAN Corp.
6
|