Form No. 8100
(1/06 )
Bryan “Flexible Water Tube”
EB Series
Steam & Water Boilers
3,200,000 to 10,000,000 BTUH
Forced draft gas, oil or dual fuel fired
Water Boiler
EB-200-W-FDGO
Steam Boiler
EB-75-S150-FDG
®
BRYAN BOILERS
Originators of the “Flexible Water Tube” design
Efficient “Flexible Water Tube” design assures
easy maintenance and low cost operation
All Bryan EB Series boilers offer these operating and performance features
The Bryan Flexible Tube
Multi-pass flue gas travel
Bryan’s exclusive “Flexible Tube” design eliminates the
possibility of damage from so-called “thermal shock.”
Tubes are easily removable and replaceable, without
welding or rolling, eliminating long, expensive downtime
should repairs ever be required.
High velocity four-pass flue gas travel is obtained by a
unique baffling system. This contributes to maximum
fire side heat transfer and overall boiler efficiency.
Thermal blend water return
Bryan’s unique “thermal blend” return blends cold or
cooler return water with warmer boiler water blending
it to design operating temperatures. An injector tube
directsthe“mixed”waterflowthroughthedowncomerto
the lower header and heating surfaces at a temperature
abovepossiblecondensingconditions.Thisreducesthe
possibility of “cold spots” and damage from corrosive
condensation.
Water cooled furnace
The configuration of the water tubes
provides a water cooled
combustion chamber.
A high percentage of
the heating surface is
exposed to direct ra-
diant heat, increasing
water velocities and heat
transfer.
Positive internal circulation
Each pass of the Bryan
Steam
Boiler
water tube slopes up-
Large steam drum
The steam drum has gen-
erous water volume and
ward.Thisconfiguration,
Water
Boiler
along with the large
volume down-comer
steam release area. This
design, along with effective drum internal functions,
results in a stable water level and produces extremely
dry steam at all load conditions.
water legs, provides the
extremely rapid natural
thermal internal circu-
lation, promoting both
high efficiency of heat
Accessibility of furnace and tube area
transfer and uniform
One hinged inner panel provides easy and complete
access to furnace and boiler tube area, as well as to
burner head. Other tube side panels are also remov-
able, and all panels are heavily insulated and sealed to
boiler frame. All access is from only one side.
temperature throughout
the boiler. Eliminating
stress damage caused
byunequaltemperaturedis-
tribution is especially important
for heating systems, particularly where
intermittent or continuous low temperature water
returns may be encountered.
Compact design, minimum floor space
With our compact water tube design, the overall size
of the unit is less than most other types of boilers.
Needing only 32" for tube removal, and on only one
side of the boiler, the EB Series boiler occupies very
little space in the boiler room. This can result in con-
siderable savings in building costs. Pressurized firing
permits minimum sized breaching and vent.
Bryan EB Series Boilers Standard and Optional Equipment
STANDARD EQUIPMENT FURNISHED
When ordering, please specify:
1. Boiler size
Straight oil fired unit
Water Boiler
OPTIONAL EQUIPMENT,
EXTRA COST
2. Supply and return tempera-
tures required
Combination thermometer and alti-
tude gauge, ASME Code rated boiler
relief valve, water temperature control
(240°F max std.), high limit control,
probe LWCO.
Electroniccombustionsafetycontrol,
oil valve, oil ignition transformer,
two-stage fuel unit — spark ignition
(EB75 & 100)/gas pilot (EB 125-240),
oil nozzle assembly, control panel, all
controls installed and wired.
3. Boiler relief valve setting
1. Manual reset high limit control
2. Manual reset low water cutoff
3. Auxiliary low water cutoff
(standard on steam boilers)
4. Combination low water cutoff
and feeder
5. Alarm bells or horns
4. Type of fuel: natural, LP, or
other gas and/or No. 2 oil
Steam Boiler
5. If gas, type, BTU content,
specific gravity and pressure
available
Combination low water cutoff and
pump control, auxiliary low water cut-
off, high limit pressure control, ASME-
rated safety valve, water glass set.
Combination gas-oil unit
Electroniccombustionsafetycontrol,
automaticmotorizedgasvalve,safety
gas valve, pilot solenoid valve, pilot
ignition assembly, main manual gas
shut-off valve, pilot cock, pilot and
main gas pressure regulators, air
safety switch, manual fuel selector
switch, oil valve, gas pilot, two-
stage fuel unit, oil nozzle assembly,
control panel, all controls installed
and wired.
6. Electric power voltage, phase
and frequency
6. CSD-1, FM, GE-GAP or other
insurance approved control
systems
Straight gas fired unit
Electronic combustion safety control,
automatic operating gas valve, safety
gas valve, pilot solenoid valve, pilot
ignition assembly, main manual gas
shut-off valve, pilot cock, pilot and
maingaspressureregulators,airsafety
switch, control panel, all controls
installed and wired.
7. Optional extra equipment or
construction
7. Indicating lights, as desired
8. Special approvals required
(UL, CSD-1, FM, or GE-GAP)
8. Lead-lag systems for two or
more boilers with or without
outdoor reset control
9. Altitude
9. Draft control system
Bryan EB Series Steam & Hot Water Boilers
FRONT VIEW
REAR VIEW
PLAN VIEW
LEFT SIDE VIEW
DIMENSIONS in inches (cm)
A
B
C
D
E
F
G
H
I
J
K
L
Supply
Boiler
Model
Length Width Height
Gas
Clearance
Min. Tube
Floor to
Overall
Length
Return
Conn.
Flue
Size
Flue
Nozzle
of
Outside Over
Train
for Servicing Removal
Flow
Location
Number
Jacket Jacket Jacket
Connection 15 psi
150 psi
Burner
Clearance
Nozzle
75½ 55 100¼
108¼
2½
6
4
2
12
13¼
48
32
104¾
EB-75-S
EB-100-S
EB-125-S
EB-150-S
EB-175-S
EB-200-S
EB-240-S
(191.77) (139.70) (254.64) (274.96)
(6.35)
(15.25)
(10.16)
(5.08)
(30.48)
(33.68)
(121.92)
(81.28)
(266.1)
98
(248.9)
55
100¼
130½
2
8
6
2
16
(40.64)
16
(40.64)
16
(40.64)
18
(45.72)
18
(45.72)
20
(50.6)
16
(40.64)
18¾
(47.63)
18¾
(47.63)
18¾
(47.63)
18¾
(47.63)
20¾
(52.7)
48
(121.92)
48
(121.92)
48
(121.92)
48
(121.92)
48
(121.92)
48
(121.92)
32
(81.28)
32
(81.28)
32
(81.28)
32
(81.28)
32
(81.28)
32
(81.28)
104¾
(266.1)
104¾
(266.1)
104¾
(266.1)
104¾
(266.1)
104¾
(266.1)
104¾
(266.1)
(139.70) (254.64) (331.4)
(5.08)
(20.32)
(15.24)
(5.08)
111
55 100¼ 143½
2½
(6.35)
2½
(6.35)
2½
(6.35)
2½
(6.35)
8
6
2
(281.94) (139.70) (254.64) (364.49)
(20.32)
(15.24)
(5.08)
111
55
100¼
143½
8
6
2
(281.94) (139.70) (254.64) (364.49)
(20.32)
(15.24)
(5.08)
152¾ 55 100¼ 185¼
(387.99) (139.70) (254.64) (470.54)
152¾ 55 100¼ 185¼
(387.99) (139.70) (254.64) (470.54)
10
(25.40)
10
(25.40)
10
(25.40)
6
2
(15.25)
(5.08)
6
2
(15.25)
(5.08)
197¾
(502.3)
55
100¼
237¼
2½
(6.35)
6
2
(139.70) (254.64) (602.6)
(15.25)
(5.08)
FRONT VIEW
PLAN VIEW
LEFT SIDE VIEW
REAR VIEW
DIMENSIONS in inches (cm)
A
B
C
D
E
F
G
H
I
J
K
L
Boiler
Model
Length Width Height
of Outside Over
Jacket Jacket Jacket
Gas
Clearance
Min. Tube Floor to
Overall
Length
Supply
Nozzle
Return
Nozzle
Flue
Size
Flue
Train
for Servicing Removal
Flow
Location
Number
Connection
Burner
Clearance
Nozzle
75½ 50 87½
108¼
2½
4
4
12
13¼
48
32
90
EB-75-W
EB-100-W
EB-125-W
EB-150-W
EB-175-W
EB-200-W
EB-240-W
(191.77) (127.00) (222.25)
(274.96)
(6.35)
(10.16)
(10.16)
(30.48)
(33.66)
(121.92)
(81.28)
(228.60)
98
(248.9)
50
87½
130½
(331.4)
143½
(364.49)
143½
(364.49)
185¼
(470.54)
185¼
(470.54)
237¼
(602.6)
2
6
6
16
(40.64)
16
(40.64)
16
(40.64)
18
(45.72)
18
(45.72)
20
(50.8)
16
(40.64)
18¾
(47.63)
18¾
(47.63)
18¾
(47.63)
18¾
(47.63)
20¾
(52.7)
48
(121.92)
48
(121.92)
48
(121.92)
48
(121.92)
48
(121.92)
48
(121.92)
32
(81.28)
32
(81.28)
32
(81.28)
32
(81.28)
32
(81.28)
32
(81.28)
90
(228.60)
90
(228.60)
90
(228.60)
90
(228.60)
90
(228.60)
90
(228.60)
(127.00) (222.25)
(5.08)
(15.25)
(15.25)
111
50 87½
2½
(6.35)
2½
(6.35)
2½
(6.35)
2½
(6.35)
6
6
(281.94) (127.00) (222.25)
(15.25)
(15.25)
111
50
87½
6
6
(281.94) (127.00) (222.25)
(15.25)
(15.25)
152¾ 50 87½
(387.99) (127.00) (222.25)
152¾ 50 87½
(387.99) (127.00) (222.25)
6
6
(15.25)
(15.25)
6
6
(15.25)
(15.25)
197¾
(502.3)
50
87½
2½
(6.35)
6
6
(127.00) (222.25)
(15.25)
(15.25)
Specifications subject to change without notice. Consult factory to consult on other boiler options.
BryanSteamLLC—LeadersSince1916
783 N. Chili Ave., Peru, Indiana 46970 U.S.A.
Phone:765-473-6651
•
Fax: 765-473-3074
•
Form No. 8100
©2006 Bryan Steam LLC
Printed in USA
16-7447
|