2. Insert the drive
Slide the carrier or tray into the appropriate bay in your host system. This
connects the drive directly to your system’s 40-pin Fibre Channel single
connector attachment (FC-SCA). The FC-SCA connector is normally
located on a Fibre Channel backpanel.
Cheetah X15 FC Installation Guide
Model ST318451FC, Fibre Channel interface disc drive
Note. There are no jumpers or terminators on the drive, and power is sup-
Publication Number: 83329487, Rev. B, September 2000
plied through the 40-pin connector.
Handling precautions/Electrostatic discharge protection
3. Connect LEDs (optional)
• Disc drives are fragile. Do not drop or jar the drive and handle the drive
only by the edges or frame.
Note. This is an optional step. The drive will work fine without the LEDs
connected to the drive.
• Drive electronics are extremely sensitive to static electricity. Keep the
drive in its antistatic container until you are ready to install it. Wear a wrist
strap and cable connected to ground. Discharge static from all items near
or that will contact the drive. Never use an ohmmeter on any circuit
boards.
The drive supplies pins that you can use to connect fault and active LEDs.
This allows you to monitor drive fault conditions and activity. The actual LED
is external to the drive.
• Turn off the power to the host system during installation.
• Always use forced-air ventilation when operating the drive.
• Use caution when troubleshooting a unit that has voltages present.
• Do not disassemble the drive; doing so voids the warranty.
• Return the entire drive for depot service if any part is defective.
• Do not apply pressure or attach labels to the circuit board or to the top of
the drive.
Drive
Front
Pin 1
J6
Electromagnetic compliance
See the Safety and Regulatory Agency Specifications page, part number
75789512 which was shipped with this installation guide.
Reserved
Port A Bypass LED [1]
Port B Bypass LED [1]
Fault LED [1]
Reserved
Drive characteristics
Formatted capacity ....................................18.4 Gbytes
Max. data blocks .......................................35,843,670 (0222EE56h)
Cylinders and heads (user accessible) ......10,377
Disc rotation ...............................................15k rpm
Average latency..........................................2.0 msec
/
10 heads
Active LED [2]
Reserved
+5V
Operating voltages .....................................+5V
Typical operating current.........................0.77A 1.15A
+12V
Active LED [1]
Ground [3]
Data buffer size ..........................................4,095 kbytes
[1] The drive has a 2.2K ohm resistor in series with this LED driver. Con-
nect the minus side of an external high-efficiency LED (i.e., 2ma) to this
pin. Connect the plus side of the LED to +5V.
What you need
[2] An external current-limiting resistor is required when connecting an
LED to this pin. The minus side of the resistor/LED combination is con-
nected to this pin. Connect the plus side to +5V.
• Phillips screwdriver and four 6-32 UNC drive mounting screws.
• Forced-air ventilation to provide adequate drive cooling. This is normally
provided by one or more fans in the host system or enclosure.
• Host system with Fibre Channel host adapter or backplane.
[3] Jumper storage location (across pins 2 and 4).
Figure 2.
LED indicator connector
Installation instructions
Fault LED Signal
1. Mount the drive in the host system carrier or tray
Most Fibre Channel host systems (including enclosures) provide a way to
insert the drive using a carrier or tray which allows the drive to be hot-
plugged into the system’s Fibre Channel 40-pin single connector attach-
ment (FC-SCA).
The drive activates the fault LED Out signal when:
• the drive detects failure of both ports.
• the drive detects an internal failure.
• the drive receives the appropriate fault LED command from the host.
Active LED signal
Mount the drive to the carrier or tray provided by the host system using four
6-32 UNC screws. Do not over-tighten or force the screws. You can mount
the drive in any orientation. See Figure 1.
The drive activates the active LED signal as indicated below.
Normal command activity
LED status
Spun down and no activity ............. Slow blink (20% on and 80% off)
Note. FC drives are designed to be attached to the host system without I/O
or power cables.
Spun down and activity .................. On
(command executing)
Spun up and no activity.................. On
Spun up and activity....................... Off
(command executing)
Spinning up or down....................... Blinks steadily (50% on and 50% off)
Format in progress ......................... Toggles on/off
(each cylinder change)
Figure 1.
Sample drive carrier
ent than the one shown. Many are actually small enclosures rather
than brackets as shown here.
|