Siemens C35i User Manual

GSM REMOTE SUPERVISION  
GB 051 Set for cellular phone Siemens C35i, M35 or S35  
Automatic Information Transfer over the GSM Network  
USER GUIDE  
LEVEL  
TABLE OF CONTENTS – GSM Remote Supervision GB 051  
1. Product Description................................ ................................ ........................ 4  
1.2. Contents of Delivery................................ ................................ ............... 5  
2. Safety Commands ................................ ................................ ......................... 5  
3. Installation and Setting into Operation................................ ............................ 6  
3.1. Assembly of GSM Remote Supervision................................ ................... 6  
3.2. Wiring and connecting the GSM Remote Supervision unit....................... 6  
3.3. Inserting the SIM Card and Connecting to the Cell Phone....................... 7  
3.4. Indication by LED ................................ ................................ ................... 9  
4. Programming by SMS Messages................................ ................................ ... 9  
4.1. PIN in GSM Remote Supervision................................ .......................... 10  
4.2. RESET of GSM Remote Supervision................................ .................... 11  
4.3. INIT – Re-initialization of Values Set from Production............................ 12  
4.4. ICALL – Regular Calling Free of Charge................................ ............... 12  
4.5. MCALL – Monthly Calling ................................ ................................ ..... 12  
4.6. ACALL – Automatic Alarm Calling................................ ......................... 13  
4.7. INFOSMS – Sending of Information Messages about Operation........... 13  
4.8. SMSINT – Interval for Dispatch of SMS Messages about Operation...... 14  
4.9. ALARMSMS – Alarm SMS Messages................................ ................... 14  
4.10. OUT – Set-up of Level of Outputs by SMS messages ........................... 15  
4.11. LIST – Detection of Set-up................................ ................................ .... 16  
4.12. CALLBACK – Monitoring of Protected Area ................................ .......... 16  
5. Programming from PC................................ ................................ .................. 17  
6. Operation during Failure of External Power Supply................................ ....... 17  
7. List of Programming Commands – Control SMS Messages.......................... 18  
8. Basic Technical Parameters................................ ................................ ......... 19  
GUARANTEE CERTIFICATE................................ ................................ ............ 20  
GUARANTEE CONDITIONS................................ ................................ ............. 21  
STATEMENT OF CONSENSUS................................ ................................ ....... 22  
3
1. Product Description  
1.1. Description of Function  
GSM Remote Supervision GB 051 consists of plastic box, which is firmly joined to  
the battery of cell phone. Communication cable with connector gets out of this box  
into cell phone, which is used by GB 051 for realization of phone connection and  
reception and sending of SMS messages.  
On the upper side of the box there is a cut-off terminal board with terminals for  
power supply, for interface to PC, control inputs and 8 input/output cables to alarm  
switchboard, to detectors or to switching electronics.  
Cable with a connector on the lower side of the box is intended for connecting a  
mobile phone Siemens (one of those: C35i, M35, S35). There is also a connector  
for data cable for connection to a PC that enables comfortable set up of required  
configuration data. All configuration parameters can also be set using SMS  
messages sent from a mobile phone or Internet.  
Red light emitting diode (LED) on the left side signalizes basic operational states,  
e.g.: correct function, function from backup power supply, GSM connection in  
ready mode, action in progress, etc.  
It is possible to prepare separate text of SMS message and to specify two  
numbers of cell phones, to which message shall be sent for each of the 8 inputs.  
Prepared text of SMS message is sent to specified numbers by activation of one  
of the 8 inputs and phone call with warning alarm signal is carried out to a  
predefined number. In case it is not possible to send SMS message or call, the  
attempt is repeated 10 times in the intervals of 5 minutes.  
Each input can be used at the same time as output and it is possible to set up  
requested value of inputs using SMS message sent from cell phone or Internet.  
It is possible to request call with additional sound monitoring of the room by  
incoming SMS message.  
It is still possible to use cell phone connected to GB 051 to carry out outgoing and  
incoming calls.  
GB 051 is self-controlled – it sends information about failure of power supply,  
messages about reset, initialization, about configuration change but also  
information messages about operation in set intervals.  
4
1.2. Contents of Delivery  
Sets  
Label  
Component description  
GB 051 010  
GB 051 011  
SA 012 602  
GSM Remote Control only  
GSM Remote Control with the Siemens C35i mobile phone  
AC/DC Adapter 220 V / 12 V DC, 600 mA, cable 1,5 m long  
Connector  
Siemens C35i mobile phone only  
External FME antenna reduction cable for the  
Siemens C35i mobile phone  
13 004 027  
13 004 028  
ED 001 001  
ED 001 002  
External 3 dB antenna with magnet, 3 meter cable  
Flat external antenna to be glued-on glass or plastic  
Converter for connection between a PC and the GB  
051 k PC, configuration software included  
Connector reduction for the ED 050 001 converter  
NiMH battery for the Siemens C35i mobile phone  
Double power switch 230 V / 5 A  
Motion detector  
Motion detector with remote control  
Push button connectable into a panel  
ED 051 011  
ED 051 050  
01 002 008  
ED 050 300  
ED 050 400  
ED 050 401  
ED 060 601  
Note:  
() included in the predefined set  
() optional accessory for the product type  
2. Safety Commands  
GB 051 is conformable with technical standards for operation in our mains.  
Power source with voltage 10–16 V DC must be used for power supply. Dimension  
for peak current is 500mA.  
While cover is removed parts under voltage can be exposed. Device must be  
disconnected from all power sources including backup battery before maintenance  
or exchange of parts or filled boards.  
While fitting together and assembling the equipment avoid cut-off of interconnecting  
cables or their damage by edges.  
No fluids must enter the device. Danger of fire, destruction of device or injury by  
electric current impend. In case it occurs pull power source out of the plug  
immediately and consult specialist.  
Avoid forceful mechanic stress of device.  
Do not place device into rooms with high temperatures, strong vibrations or high  
humidity.  
In case you moved device from cool to warm room do not set it into operation  
immediately. Water condenses on device and operation under these circumstances  
can cause damage of device. Let device warm up to temperature of room. Wait  
until condensed water evaporates.  
5
The GB 051 unit must be stocked always with the mobile phone connector  
disconnected – when disconnected from external power supply, the GB 051 is  
supplied from the mobile phone battery and the battery can be damaged by getting  
completely flat.  
!
3. Installation and Setting into Operation  
3.1. Assembly of GSM Remote Supervision  
GSM Remote Supervision by LEVEL is designed for operation in dry places.  
During assembly avoid hot places and places where device would be exposed to  
direct solar radiation or places close to heating elements.  
Do not place GSM Remote Supervision or aerial mast close to phone exchange  
or other electronic devices or lines. Due to high-frequency electromagnetic field  
these devices could be interfered.  
Due to interference it is not advisable to operate device close to other power or  
high-frequency devices.  
Before assembly prove by cell phone if there is sufficient level of signal required  
by GSM network in selected place. Pay attention to delay in indicating of signal  
level.  
When using for protection of property, arrange protection of area against break-in  
by detector.  
3.2. Wiring and connecting the GSM Remote Supervision unit  
Top view  
Connector description  
1) input/output No. 1  
2) input/output No. 2  
3) input/output No. 3  
4) input/output No. 4  
5) input/output No. 5  
6) input/output No. 6  
7) ground  
8) input/output No. 7  
9) input/output No. 8  
10) power supply + 12 V  
Bottom view  
Connector description  
1. Init  
2. Ground  
3. Reset  
4. TxD  
5. RxD  
6. +Ucc  
6
RESET By connection clips no. 2 and 3 (ground and reset) the unit reset will  
be run, while all the set configuration value will remain in place.  
The value of days in service will be set to 0.  
INIT  
Detailed description of how to carry on the initialization can be found  
in Chapter 4.1. The GSM Remote Control device will be set into  
default manufacturer’s settings by the initialization.  
Recommended linkage of outputs:  
Recommended linkage of inputs:  
If GSM signal is insufficient external antenna can be connected to cell phone.  
Professional solution of switching electrical devices on and off is provided by the  
230 V/5 A double power switch ED 050 300 that can be purchased as optional  
accessory.  
For connection with a PC use always the ED 051 011 converter with cable that  
connects into the connector at the bottom side of the unit and into the RS 232  
interface in your PC. If you need to connect the PC using the older ED 050 001  
converter, use the new optional accessory ED 051 050 (cable with reduction,  
Control Panel software included).  
The GB 051 device is able to work fully without external power supply for  
approximately 12 hours being supplied from the mobile phone battery.  
3.3. Inserting the SIM Card and Connecting to the Cell Phone  
GSM Remote Supervision can be used only with cell phones Siemens C35, M35  
and S35. Do not attempt to connect other phones, it may cause device or phone  
damage.  
Always use only NiMH battery with the GB 051. Using a Li-Ion battery might result  
in unstable function of the GSM Remote Supervision; this type of battery can  
cause the mobile phone to turn off without the possibility of starting up  
automatically  
7
Cell phone must be in basic configuration, only parameters specified further can  
be changed.  
A SIM card inserted in the GB 051 device must be configured in one of the two  
ways described below:  
a) If SIM is not blocked by PIN code, then the PIN value in GB 051 is irrelevant –  
in this case you can skip this instruction and continue to  
assembly the GB 051 and the cell phone.  
b) If SIM is blocked by PIN, and then the PIN in GB 051 must be the same with  
the PIN at the SIM in mobile phone. The default PIN code in the GB 051 unit  
is set from production as “0000” (This will also be the PIN value after unit’s  
initialization).  
How to change PIN code in the Siemens mobile phones:  
In menu select Setup – Security – Codes – Change PIN and the phone will ask  
you to enter first the current PIN and then to enter and verify the new PIN code –  
enter PIN “0000”.  
Description of first assembly:  
1. Insert the SIM card and battery into the cell phone, put on the back cover.  
2. Stick the GB 051 unit together with the back cover of the mobile phone,  
connectors must be faced down.  
3. Interconnect the GB 051 with connector in the cell phone.  
4. Connect the 12 V external power supply connector.  
5. After the power supply is connected, the GB 051 will automatically turn on  
the phone and if the PIN code is requested by the phone, the unit will  
automatically enter the PIN predefined in configuration.  
6. Wait to see the cell phone to connect to the GSM network, the LED should  
start blinking slowly.  
7. Following this it is recommended to send a command SMS as described  
below to set a new PIN (other than 0000) in the GB 051 and the SIM card for  
security reasons. This will also verify the correct functionality of the GB 051  
device – by confirming it can receive the command SMS and set reply  
message back.  
After the inquiry on the phone display enter PIN with phone keyboard and wait  
until phone logs in. From this moment GSM Remote Supervision is able to accept  
control SMS messages.  
Therefore send control message (command) to cell phone connected to GB 051:  
XX0000PINVpppp  
Where:  
XX  
means two capital letters X  
0000  
PIN  
V
is the current PIN in GB 051 (manufacturer setting is 0000)  
is the key word of the command  
is the “space” symbol  
pppp  
is the new PIN value  
8
If the PIN code on the SIM card is the same as the PIN in GB 051 and SIM is  
blocked by PIN, then after setting new PIN to the GB 051 unit the PIN will be  
changed in both – the SIM and GB 051 unit.  
GB 051 replies to this SMS message and draws sender’s attention to necessity of  
unification of PIN in Remote Supervision and phone and to necessity of switch-off  
of cell phone.  
After reception of this SMS message verify correct PIN code change by switching  
the phone off with the red phone button. If PIN is set correctly and external power  
supply is connected GB 051 automatically switches on the phone, sets PIN and  
LED starts to flash in slow rhythm. It signalizes readiness of Remote Supervision  
for reception and sending messages. At the same time new PIN is entered into  
memory of GB 051.  
It is possible to set up volume of cell phone ringing according to your need in  
main menu. Ringing of the phone can be eventually switched off completely. It is  
possible to change or switch off the sound indicating reception of SMS message  
either. Furthermore, volume of conversation can be changed (only the volume of  
speaker is concerned).  
If SMS centre is not correctly set on SIM card it is necessary to set it up in cell  
phone menu.  
3.4. Indication by LED  
Indicating LED on the side of GB 051 indicates basic operating states:  
Slow regular flashing  
Remote Supervision is prepared for operation  
Occasional short flash Remote Supervision is prepared but runs from  
backup battery  
6 quick flashes  
3 quick flashes  
Quick flashing  
Action in progress – after an input is activated  
Incoming SMS command message  
Not ready for ALARM, no connection to the GSM  
4. Programming by SMS Messages  
Number of functions and parameters, which allow adjustment of GSM Remote  
Supervision to environment and user’s requirements can be configured by  
programming. At the same time programming allows control of functions by user.  
Programming can be carried out either remote by SMS message from cell phone or  
Internet if available - or comfortably using the Control Panel software and the ED  
051 011 communication converter with cable connected to the serial port of your PC.  
9
Send a control SMS message from cell phone or Internet, which includes in text:  
XXppppINSTRUCTIONVparameter  
XX  
Two capital letters X  
pppp  
Four digits of current PIN in GSM Remote Supervision  
INSTRUCTION Key word of the command (no difference with capital or small  
letters)  
V
Space follows  
parameter  
Set-up value*  
End of sequence by space or end of SMS message  
One SMS can include up to 4 commands. The message then can look like this:  
XXppppCOMMAND1Vparameter1VCOMMAND2Vparameter2VCOMMAND3Vparameter3V…  
A confirming message is sent to the number the command message came from, this  
message includes information about the new set parameter value.  
4.1. PIN in GSM Remote Supervision  
So as GSM Remote Supervision works correctly it is necessary that PIN on SIM  
card corresponds with PIN of GSM gate and is different from 0000. In phone menu  
SIM card must be blocked, tm. control of PIN after switch-on must be activated.  
If the SIM card is blocked by a PIN code, connect the GB 051 to the mobile phone  
only after the PIN in GB 051 was set to the same value – otherwise there is a  
great risk of the SIM card getting blocked.  
Change of PIN  
Command*  
pppp  
XXppppPINVnnnn  
Four digits of current PIN in GSM Remote Supervision  
nnnn  
Four digits of new PIN  
* Space must be between the key word of command “PIN” and value of parameter “nnnn“  
GB 051 confirms reception of Command to sender and draws his attention to  
necessity of correspondence of PIN in GSM Remote Supervision and on SIM  
card of cell phone. At the same time advises of necessity of switching off the  
phone by red key. This way new PIN is entered into GSM Remote Supervision  
memory and connected cell phone is automatically switched on.  
Information about GB 051 reset and change of PIN is sent to INFOSMS number  
after action is successfully carried out.  
In case the PIN code is the same on the SIM card and in the GB 051 unit and the  
SIM is blocked by PIN, then after entering a new PIN into GB 051 the PIN code  
on the SIM card will be changed as well.  
10  
Value of PIN of GSM gate set from production and after initialization is 0000. PIN  
0000 shall not be set into cell phone from gate so that blockage of phone is not  
caused during first contacts with gate.  
Example:  
Original PIN of GSM gate is 0000. SIM card, which you use in cell phone in GSM  
gate has PIN 1234 and is blocked by PIN.  
Insert the SIM card into the mobile phone, but do not connect the GB 051  
connector yet. Insert the required PIN in the mobile phone (e.g. 1234). Go into the  
mobile phone menu and select Settings – Security – Codes – Change PIN then  
insert the old PIN and the new PIN according to the mobile phone instructions.  
Send a command SMS message with text XX0000PINV1234 from cell phone or  
Internet on cell phone number in the unit.  
As soon as a confirmation SMS message comes back to sender’s cell phone the  
new PIN is set to value “1234”  
User can verify the PIN change by switching the phone off.  
Initialization:  
In case you forget current PIN of GSM Remote Supervision you have no choice  
than to carry out initialization of parameters to original set-up from production. It  
shall be carried out in following steps:  
1. Disconnect external power supply. (throw up power adapter)  
2. Disconnect the mobile phone connector.  
3. Interconnect inputs GROUND and INIT (terminals No. 1 and 2, see Chapter  
3.2.) on terminal board  
4. Connect external power supply. (throw in power adapter)  
5. Remove connection GROUND – INIT  
6. Disconnect external power supply. (throw up power adapter)  
7. Connect the mobile phone to the GB 051 unit – the PIN must be preset to  
value “0000”.  
8. Connect external power supply.  
9. PIN and other required parameters have to be set-up again  
4.2. RESET of GSM Remote Supervision  
If you want to carry out remote reset of counters of days and months in operation  
then send SMS message with Command RESET. Command is rejected if GB 051  
runs from backup battery.  
Command  
Pppp  
XXppppRESET  
Four digits of current PIN  
Function is equivalent to disconnection of gate from power supply (also backup  
one) and its re-connection.  
11  
4.3. INIT – Re-initialization of Values Set from Production  
In case you lost view of GB 051 set-up you can carry out remote re-initialization of  
parameter values set in production.  
Command  
Pppp  
XXppppINIT  
Four digits of current PIN  
GSM Remote Supervision will be set to initial set-up from production.  
Sender of Command receives message about correct reception of Command.  
In case you do not know pre-set PIN or you are not able to program for another  
reason then carry out hardware initialization described in chapter 4.1.  
4.4. ICALL – Regular Calling Free of Charge  
If you want to be informed free of charge about correct function of GB 051 in set  
regular intervals following parameters provide it:  
Command  
Pppp  
XXppppICALLVnumber *1)  
Four digits of current PIN  
Number  
Maximum 14 digits of number of any phone which allows  
display of caller’s number *2)  
*1) The space is between key word of command „ICALL“ and value of parameter “number”  
*2) Number can be entered in national format – e.g. 606445566 but also in international  
format – e.g. +420606445566.  
Command  
Pppp  
H
XXppppICALLINTVh *1)  
Four digits of current PIN  
Length of intervals in hours – time interval of two successive  
calls. Value from 1 to 240 hours can be set. 168 hours set from  
production.  
*1) The space is between key word of command „ICALLINT“ and value of parameter „h“  
After set-up of these parameters calling to set number will be automatically  
activated. Phone rings only 5s and does not await pick-up. This way record about  
calling from GB 051 is entered on display of cell phone without any charges  
unless called party picks it up.  
If you want to deactivate this functions set, send the command without parameter  
– for example: XXppppICALL or XXpppICALLINT without further parameters.  
4.5. MCALL – Monthly Calling  
Some GSM operators require requires to carry out at least one paid phone  
connection in 3 months from this card in order to keep the SIM card working –  
otherwise the prepaid credit might expire. In order to prevent this from happening  
it is possible to enter a number into GB 051, which the unit will automatically call  
every month of operation, the phone call will be hung up 10 seconds after pick up.  
12  
Command  
Pppp  
Number  
XXppppMCALLVnumber *1)  
Four digits of current PIN  
Maximum 14 digits of number of any phone *2)  
*1) The space is between key word of command „MCALL“ and value of parameter „h“  
*2) Number can be entered in national format – e.g. 606445566 but also in international  
format – e.g. +420606445566. No number is activated from production.  
After entering this parameter GB 051 calls set number once a month in order to  
spend at least one tariff impulse.  
If you want to use this service it is recommended to set-up number of your fax or  
number of time information. It is not recommended to set your cell phone number  
because GB 051 does not use real time and call can come during night.  
If you want to deactivate this function set command without parameter – for  
example XXppppMCALL without further parameters.  
4.6. ACALL – Automatic Alarm Calling  
By activation of any of SMS inputs set phone number is automatically chosen  
together with sending SMS message. Dispatched SMS message can be  
highlighted if you set ACALL number identical to SMSNO number or you can  
report alarm on fixed phone lines where SMS messages cannot be received. After  
answering warning tone is generated into speaking line.  
Command  
Pppp  
XXppppACALLiVnumber *1)  
Four digits of current PIN  
i
Number of input: 1 to 8  
Number  
Maximum 14 digits of number of any phone which allows  
display of caller’s number *2)  
*1) The space is between key word of command „ACALLi“ and number  
*2) Number can be entered in national format – e.g. 606445566 but also in international  
format – e.g. +420606445566. No number is activated from production.  
If you want to deactivate this function set command without parameter – tm.  
XXppppACALLi without further parameters.  
4.7. INFOSMS – Sending of Information Messages about Operation  
GB 051 allows set-up of one cell phone number where all information SMS  
messages about change of PIN, reset, initialization, power supply failure, change  
in configuration, operation time and input activation are subsequently sent.  
Command  
XXppppINFOSMSVnumber (no number activated from  
production) *1)  
Pppp  
Number  
Four digits of current PIN  
Maximum 14 digits of cell phone number *2)  
*1) The space is between key word of command „INFOSMS“ and number  
*2) Number can be entered in national format – e.g. 606445566 but also in international  
format – e.g. +420606445566.  
13  
If you want to deactivate this function set command without parameter – tm.  
XXppppINFOSMS without further parameters.  
4.8. SMSINT – Interval for Dispatch of SMS Messages about Operation  
Interval for sending regular SMS messages to INFOSMS number, which include  
time of operation, can be set:  
Command  
XXppppSMSINTVn (interval of one day is set from production)  
*1)  
pppp  
Four digits of current PIN  
Number  
Number from 1 to 30. It is interval for sending successive  
message about operation.  
*1) The space is between key word of command „SMSINT“ and value of parameter n“  
4.9. ALARMSMS – Alarm SMS Messages  
When one of 8 inputs is activated GB 051 allows in addition to phone call to  
common ACALL number also sending one of 8 prepared texts of SMS message  
to two cell phone numbers.  
Change of texts of SMS messages:  
Order on the  
terminal  
Command *1)  
Initial set-up  
Input  
board  
XXppppSMSTXT1V“text“  
XXppppSMSTXT2V“text“  
XXppppSMSTXT3V“text“  
XXppppSMSTXT4V text“  
XXppppSMSTXT5V“text“  
XXppppSMSTXT6V“text“  
XXppppSMSTXT7V“text“  
XXppppSMSTXT8V“text“  
pppp  
ALARM1  
ALARM2  
ALARM3  
ALARM4  
ALARM5  
ALARM6  
ALARM7  
ALARM8  
IO1  
IO2  
IO3  
IO4  
IO5  
IO6  
IO7  
IO8  
1
2
3
4
5
6
8
9
Four digits of current PIN  
4 - 144 digits, always put in quotes, ?=question  
text  
*1) The space is between key word of command “SMSTXT” and “text”  
Change of numbers for sending ALARM SMS messages  
Text of SMS message No. 1, 2, 3, 4, 5, 6, 7 or 8 will be sent by activation of input  
No. 1, 2, 3, 4, 5, 6, 7 or 8 (by connection with terminal No. 7 – ground) on terminal  
board of GB 051. Each prepared text of SMS message of particular input can be  
sent to two cell phone numbers.  
No number is activated from production. These numbers can be set:  
14  
Activated by input  
No.:  
Order on the  
terminal board  
Command *1)  
XXppppSMSNOA1Vnumber  
XXppppSMSNOB1Vnumber  
XXppppSMSNOA2Vnumber  
XXppppSMSNOB2Vnumber  
XXppppSMSNOA3Vnumber  
XXppppSMSNOB3Vnumber  
XXppppSMSNOA4Vnumber  
XXppppSMSNOB4Vnumber  
XXppppSMSNOA5Vnumber  
XXppppSMSNOB5Vnumber  
XXppppSMSNOA6Vnumber  
XXppppSMSNOB6Vnumber  
XXppppSMSNOB7Vnumber  
XXppppSMSNOB7Vnumber  
XXppppSMSNOB8Vnumber  
XXppppSMSNOB8Vnumber  
pppp  
IO1  
IO1  
IO2  
IO2  
IO3  
IO3  
IO4  
IO4  
IO5  
IO5  
IO6  
IO6  
IO7  
IO7  
IO8  
IO8  
1
1
2
2
3
3
4
4
5
5
6
6
8
8
9
9
Four digits of current PIN  
Maximum 14 digits of cell phone number  
Number *2)  
*1) The space is between key word of command and number  
*2) Number can be entered in national format – e.g. 606445566 but also in international  
format – e.g. +420606445566.  
If you want to deactivate the number set command without number – tm. e.g.  
XXppppSMSNOA3 without further parameters.  
4.10. OUT – Set-up of Level of Outputs by SMS messages  
Required logical level of outputs No. 1 to 8 can be set by incoming SMS  
message. If output is set to logical value 0 it is not possible to activate it as input.  
Order on the  
terminal board  
Command *1)  
Output  
XXppppOUT1Vy  
XXppppOUT2Vy  
XXppppOUT3Vy  
XXppppOUT4Vy  
XXppppOUT5Vy  
XXppppOUT6Vy  
XXppppOUT7Vy  
XXppppOUT8Vy  
pppp  
IO1  
IO2  
IO3  
IO4  
IO5  
IO6  
IO7  
IO8  
1
2
3
4
5
6
8
9
Four digits of current PIN  
y
Figure 0 or 1 determines logical level of output  
By sending value 0 output is set to 0V  
By sending value 1 output is set to 4-5V  
*1) The space is between key word of command and value of parameter “y”  
All outputs are set to logical level 1 (4–5 V) from production.  
Inputs can be therefore activated.  
15  
If you only want to change value of output regardless of previous state send  
command without parameter “y” – e.g. XXppppOUT5 changes value of output No.  
5 to reverse.  
Newly set actual values of all 8 inputs/outputs are sent back to sender and to  
INFOSMS number.  
4.11. LIST – Detection of Set-up  
If you want to find out which values of parameters are set in GB 051 it is possible  
to send control SMS message, which initiates sending messages with detailed  
description of set-up back to sender.  
Command  
XXppppLISTVi *1)  
pppp  
i
Four digits of current PIN  
IO number: 1 to 8, with no parameter will return the  
shared configuration  
*1) The space is between key word of command “LIST” and “i”  
SMS command messages intended for getting parameter configuration of each  
input/output 1–8:  
The GB 051 unit will return sender a message with the required configuration  
information related to the particular IO:  
·
·
·
·
·
Actual value of logical level of the particular input.  
Pre-set phone number for ALARM call.  
Pre-set number A for ALARM SMS for the particular input.  
Pre-set SMSNO B for the input.  
Pre-set SMSTXT – text of the message of the input.  
IO value, acall, aSMSnoA, aSMSnoB, SMStxt  
In case the command SMS message is sent with no parameter, the GB 051 unit  
will respond to the sender with message containing five basic configuration data:  
infoSMS number, infoSMS interval, icall number, icall interval, mcall number  
4.12. CALLBACK – Monitoring of Protected Area  
If you want to find out by listening – e.g. during alarm – what is happening in  
place of installation it is possible to require, by SMS message, to get further call  
from GB 051 with switched-on microphone for room monitoring.  
Command *1)  
pppp  
XXppppCALLBACKVnumber  
Four digits of current PIN  
Number  
Maximum 14 digits of any phone number *2)  
*1) The space is between key word of command „CALLBACK“ and number.  
*2) If no number is specified GB 051 calls back the number of sender of SMS command.  
Number can be entered in national format – e.g. 606445566 but also in international  
format – e.g. +420606445566.  
16  
The call will take 255 seconds unless you end it sooner by hang-up.  
Sensitivity of cell phone built-in microphone might be relatively low. Therefore it is  
necessary to select a suitable placement of the unit in order to use this feature.  
5. Programming from PC  
Comfortable way of setting of all GB 051 parameters from PC by the means of  
configuration program and serial cable with converter can be used. Program and cable  
can be bought additionally as set for configuration from PC – supply No. ED 051 011.  
Program shall be installed under MS WINDOWS by command A:\setup. Connect  
GB 051 through interconnecting cable with converter ED 051 011. Program allows  
reading of actual configuration from GB 051, changing of configuration and exporting of  
new configuration into GB 051. Configuration can also be saved and read from files.  
6. Operation during Failure of External Power Supply  
During failure of external power supply GB 051 operates, with unchanged output, for  
approx. 12 hours from battery. However, it is not able to switch on the cell phone  
without external power supply and therefore command RESET is ignored.  
Configuration, which you enter in GB 051, will be saved in memory – type EEPROM –  
for arbitrarily long time even during disconnection or total discharge of backup battery.  
17  
7. List of Programming Commands – Control SMS Messages  
Command XXpppp  
Description  
Range  
Set  
*1)  
PINVnnnn  
RESET  
INIT  
Set PIN  
nnnn 4 digits of PIN  
n= max. 14 digits  
h= 1–240 (hours)  
n= max. 14 digits  
n= max. 14 digits  
n= max. 14 digits  
n= 1–255 (days)  
0000  
168  
7
RESET of GSM Supervision  
Initialisation of parameters  
Regular information calling  
Length of interval of calling  
Monthly calling  
ICALLVn  
ICALLINTVh  
MCALLVn  
ACALLiVn  
INFOSMSVn  
SMSINTVn  
Alarm calling  
Information number  
Interval of sending information  
SMS messages  
SMSTXT1V“text”  
SMSTXT2V“text”  
SMSTXT3V“text”  
SMSTXT4V“text”  
SMSTXT5V “text”  
SMSTXT6V “text”  
SMSTXT7V“text”  
SMSTXT8V“text”  
SMSNOA1Vn  
SMSNOB1Vn  
SMSNOA2Vn  
SMSNOB2Vn  
SMSNOA3Vn  
SMSNOB3Vn  
SMSNOA4Vn  
SMSNOB4Vn  
SMSNOA5Vn  
SMSNOB5Vn  
SMSNOA6Vn  
SMSNOB6Vn  
SMSNOA7Vn  
SMSNOB7Vn  
SMSNOA8Vn  
SMSNOB8Vn  
OUT1Vy  
Alarm SMS messages  
text of 4–144 digits put in ALARM1  
“ ”  
ALARM2  
ALARM3  
ALARM4  
ALARM5  
ALARM6  
ALARM7  
ALARM8  
Numbers for  
sending  
ALARM SMS  
messages  
IO1 SMS n A  
IO1 SMS n B  
IO2 SMS n A  
IO2 SMS n B  
IO3 SMS n A  
IO3 SMS n B  
IO4 SMS n A  
IO4 SMS n B  
IO5 SMS n A  
IO5 SMS n B  
IO6 SMS n A  
IO6 SMS n B  
IO7 SMS n A  
IO7 SMS n B  
IO8 SMS n A  
IO8 SMS n B  
n= max. 14 digits  
1
1
1
1
1
1
1
1
Set output No.1 (terminal No.1)  
Set output No.2 (terminal No.2)  
Set output No.3 (terminal No.3)  
Set output No.4 (terminal No.4)  
Set output No.5 (terminal No.5)  
Set output No.6 (terminal No.6)  
Set output No.7 (terminal No.8)  
Set output No.8 (terminal No.9)  
Find out set-up  
y= 0 output in logical  
value 0  
y= 1 output in logical  
value 1  
without y – logical value  
0
OUT2Vy  
OUT3Vy  
OUT4Vy  
OUT5Vy  
OUT6Vy  
OUT7Vy  
OUT8Vy  
LISTVn  
n= input No. 1 to 8  
Without n – returns  
common set-up  
CALLBACKVn  
Call with monitoring  
n= max. 14 digits  
Without no. calls back  
*1) Always start with text XXpppp, where “pppp” is PIN of GB 051  
18  
8. Basic Technical Parameters  
GB 051  
ALARM tone  
400 Hz  
Inputs of SMS messages No. 1–8  
Logical 0  
Logical 1  
0–0,5 V  
4–6 V  
Outputs of SMS messages No. 1–8  
Logical 0  
max. 0,8 V for Iz= 5 mA  
Logical 1  
3,5–4,5 V  
for Iz= 0,03 mA  
GSM network  
GSM  
SIM card  
900/1800 MHz  
Plug-in  
Device  
Power supply voltage  
10–16 V DC  
Peak power consumption during charging 350 mA (for 12 V)  
Max. time of charging  
Power consumption with charged battery  
Time of operation from backup battery  
Size  
4 hours  
< 20 mA  
Min. 12 hours  
65 × 70 × 17 mm  
50 g  
Weight  
Operational temperatures  
from +5 to +40 °C  
19  
GUARANTEE CERTIFICATE  
Product name: ..........…....................... Type: …….....…………....................………..  
Production number: .…...................…. Date of sale: .............…………........………..  
Signature: …………….............………. Seller (stamp): ………………………………..  
Information about guarantee repairs:  
Date of  
receipt  
Date of  
return  
Signature  
Description of defect  
Producer: LEVEL ltd., Plhovská 1997, 547 01 Náchod. Czech Rep.  
Tel/Fax No.: +420 491-44 66 11. e-mail: [email protected], www.levelna.cz  
20  
GUARANTEE CONDITIONS  
Length of guarantee period is 24 months from the date of sale.  
Guarantee applies only to goods registered or identified by company LEVEL.  
Guarantee repair will be carried out at latest within 10 working days after receipt of  
defective goods by company LEVEL provided that spare part is disposable in store. If it  
is not possible alternative solution will be offered to user for time of repair.  
Guarantee repairs will be carried out in company seat.  
Technician is solely responsible for choosing the way of transport.  
Guarantee is not provided in following cases:  
Loss or replacement of Guarantee Certificate – or its additional correction.  
Damage of device caused by natural disaster or damage of device during transport.  
Damage caused by unsuitable positioning, unsuitable handling, operation of device in  
unsuitable conditions.  
Any unauthorized repair or adjustment carried out on device.  
Damage or removal of sealing labels.  
Guarantee does not apply to expendable property – dyeing ribbons, floppy discs, etc. It  
does not apply to malfunction caused by installed software or interference, either.  
Company is not responsible for possible losses, which originate from device failure  
either.  
Guarantee does not apply to malfunction caused by change of external conditions as  
change in legislation, change of phone network, change of supply network, etc.  
Guarantee is exerted by hand-over of completely filled-in Guarantee Certificate and  
hand-over of device intended for repair including equipment.  
21  
STATEMENT OF CONSENSUS  
We, LEVEL Ltd.., Plhovská 1997, 547 01 Náchod, Registration No.: 47469374, V.A.T.  
No.: 243-47469374,  
declare hereby our exclusive responsibility that hereinafter mentioned product meets  
requirements of technical regulations, that product is save when used on specified  
conditions and that we took all actions, which ensure consensus of all products of  
hereinafter mentioned type placed on the market with technical documentation and with  
requirements of relevant government regulation.  
Product:  
Type:  
Remote Supervision  
GB 051 010  
Product is designed for telecommunication purposes  
Way of consensus judging:  
§12/4/a of law No.22/1997 of Col.  
Above mentioned product is conformable with  
and government regulation  
§8 of law No.22/1997 of Col.  
No.169/1997 of Col.  
and standards for electromagnetic compatibility ČSN 342895; ČSN EN 55 022class B  
and government regulation for electrical safety  
No. 168/1997 of Col.  
Additional information:  
Power supply is carried out by safe voltage of 10–16 V (direct current) Device is  
compatible only with cell phone Siemens C35, M35 and S35.  
Released in:  
Náchod  
Name:  
Ing. Michal Falta  
Date of release:  
01.08.2003 Function:  
Managing Director  
Stamp and signature:  
22  
23  
GB [email protected] © LEVEL, 2003  
LEVEL Ltd, Plhovská 1997, Náchod 547 01  
CZECH REPUBLIC  
24  

The Singing Machine SMB 635 User Manual
Sprint Nextel J120 User Manual
Sony Ericsson T618 User Manual
Seagate ST9160827AS User Manual
Seagate Pulsar2 ST100FM0012 User Manual
Seagate MOMENTUS ST750LX003 User Manual
Seagate BARRACUDA ST330630A User Manual
Seagate BARRACUDA 9 ST19171WC User Manual
Samsung Spinpiont SP2004C User Manual
PYLE Audio PICL48 User Manual