CDA HCG 741 User Manual

HCG 731 .. - HCG 741 ..  
Cooking Hobs  
Manual for Installation, Use and Maintenance  
GB  
Customer Care Department • The  
Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HY  
T : 01949 862 012 F : 01949 862 003 E : [email protected] W : www.cda.eu  
3
Important Safeguards and Recommendations  
– Do not carry out any cleaning or maintenance without first disconnecting the appliance from the  
electrical supply.  
– During and after use of the hob, certain parts will become very hot. Do not touch hot parts.  
– After use always ensure that the control knobs are in the “” OFF position.  
Young children should be supervised to ensure that they do not play with the appliance.  
– Keep children away from the hob during use.  
– Children, or persons with a disability which limits their ability to use the appliance, should have a  
responsible person to instruct them in its use. The instructor should be satisfied that they can use the  
appliance without danger to themselves or their surroundings.  
– Do not allow young children or infirm persons to use the appliance without your supervision.  
WARNING! When correctly installed, your product meets all safety requirements laid down for this  
type of product category. However special care should be taken around the underneath of the appliance  
as this area is not designed or intended to be touched and may contain sharp or rough edges, that may  
cause injury.  
Fire Risk! Do not leave inflammable materials on the hob top.  
– Make sure that electrical cords connecting other appliances in the proximity cannot come in to contact  
with the hob top.  
– Never use a damaged appliance. Get it checked or repaired: “see appliance servicing”.  
– When the appliance is not being used, it is advisable to keep the gas tap closed.  
– Regular lubrication of the gas taps must only be carried out by qualified engineers. Contact Service in  
case of problems with the operation of the gas taps.  
– Before disposing of an unwanted appliance, it is recommended that it is made inoperative and that all  
potentially hazardous parts are made harmless.  
– If the supply cord is damaged, it must be replaced by a special cord by a qualified electrical  
technician in order to avoid a hazard.  
Before Using for the First Time  
– Read the instructions carefully before installing and using the appliance  
– After unpacking the appliance, make sure it is not damaged. In case of doubt, do not use the appliance  
and contact your supplier or a qualified engineer.  
– Remove all packaging and do not leave the packing material (plastic bags, polystyrene, bands etc ) in easy  
reach of children as they may cause serious injury. The packaging materials are recyclable.  
– The appliance should be installed and all the gas/electrical connections made by a qualified engineer in  
compliance with local regulations in force and following the manufacturer’s instructions.  
– Do not attempt to modify the technical properties of the appliance, as it may become dangerous to  
use.  
4
Features and Technical Data  
HCG 741 ..  
HCG 731 ..  
3
2
3
2
1
4
4
2
2
1
Fig. 1a  
Fig. 1b  
5
6
8
9
5
8
9
7
6
7
Cooking Points  
This appliance is  
class 3  
1. Auxiliary burner (A)  
2. Semi-rapid burner (SR) - 1,75 kW  
3. Rapid burner (R) - 3,00 kW  
- 1,00 kW  
4. Triple ring burner (TR) - 3,50 kW  
Control Panel  
5. Auxiliary burner control knob (1)  
6. Rear left semi-rapid burner control knob (2)  
7. Triple ring burner control knob (4)  
8. Rapid burner control knob (3)  
9. Front right semi-rapid burner control knob (2)  
Note:  
– The electric ignition is incorporated in the knobs.  
– The appliance has a safety valve system fitted. The flow of gas will be stopped if and when the flame  
should accidentally go out.  
Caution:  
– If the burner is accidentally extinguished, turn the gas off at the control knob and wait at least 1 minute  
before attempting to relight.  
– Gas hobs produce heat and humidity in the environment in which they are installed. Ensure that the  
cooking area is well ventilated by opening the natural ventilation grilles or by installing an extractor  
hood connected to an outlet duct.  
– If the hob is used for a prolonged time it may be necessary to provide further ventilation by opening a  
window or by increasing the suction power of the extractor hood (if fitted).  
5
How to Use the Hob  
Gas Burners  
Gas flow to the burners is adjusted by turning the knobs (illustrated in fig.2) which control the valves.  
Turning the knob so that the indicator line points to the symbols printed on the panel achieves the  
following functions:  
– Symbol  
– Symbol  
– Symbol  
: Tap closed (burner off)  
: High (maximum)  
: Low (minimum)  
– The maximum aperture position permits rapid boiling of liquids, whereas the minimum aperture position  
allows slower warming of food or maintaining boiling conditions of liquids.  
To reduce the gas flow to minimum, rotate the knob further anti-clockwise to point the indicator  
towards the small flame symbol.  
– Other intermediate operating adjustments can be achieved by positioning the indicator between the  
maximum and minimum aperture positions, and never between the maximum aperture and closed  
positions.  
Caution!  
The cooking hob becomes very hot during operation. Keep children well out of reach.  
Fig. 2  
6
Lighting Gas Burners  
In order to light the burner, you must:  
1 – Press in the corresponding knob and turn counter-clockwise (fig. 3) to the full flame position marked  
by the  
symbol and hold the knob in until the flame has been lit.  
In the case of a mains failure light the burner with a match or lighted taper.  
2 – Wait about ten seconds after the gas lighting before releasing the knob (starting time for the valve).  
3 – Adjust the gas valve to the desired power.  
Important  
If the burner flame should go out for some reason, the safety valve will automatically stop the gas flow.  
To re-light the burner, return the knob to the closed position, wait for at least 1 minute and then  
repeat the lighting procedure.  
If your local gas supply makes it difficult to light the burner with the knob set to maximum, set the knob  
to minimum and repeat the operation.  
Fig. 3  
7
Choice of Burner  
The symbols printed on the panel by the side of the knob indicate which burner you are controlling.  
Choose a suitable burner depending on the cookware diameter and capacity.  
The pan diameter should be suitable for the burner power to make the most of the burner's high efficiency  
and not waste fuel.  
A small pan does not boil more quickly on a large burner (fig. 4).  
Fig. 4  
Burner Size  
Auxiliary  
Minimum Pan Diameter (cm) Maximum Pan Diameter (cm)  
12  
16  
24  
26  
-
14  
(1)  
Semi-Rapid  
Rapid  
24  
26  
28  
36  
Triple Ring  
(2)  
Wok  
(1) front right burner, maximum diameter 22 cm.  
(2) Wok pans have to be used only with the special grille fitted (see correct use of triple-ring burner).  
8
Correct use of Triple-Ring Burner  
The flat-bottomed pans are to be placed directly onto the pan-support.  
To use the WOK you need to place the proper stand in order to avoid any faulty operation of the triple-  
ring burner (Figs. 5a - 5b - 6a - 6b).  
Important: The wok pan stand (fig. 5b - 6b) MUST BE PLACED ONLY over the pan-rest for the triple  
ring burner.  
Model:  
WRONG  
CORRECT  
HCG 731 ..  
Fig. 5a  
Fig. 5b  
Model:  
WRONG  
CORRECT  
HCG 741 ..  
Fig. 6a  
Fig. 6b  
9
Cleaning and Maintenance  
General Tips  
– Before cleaning the hob switch it off and wait for it to cool down.  
– Clean with a cloth, hot water and soap or liquid detergent.  
– Do not use products which are abrasive, corrosive or chlorine based.  
– Do not use steel pads.  
– Avoid using cleaning products with a chlorine or acidic base.  
– Do not leave acid or alkaline substances (vinegar, salt, lemon juice, etc.) on the hob.  
– Steam cleaners must not be used when cleaning this appliance.  
Warning: When correctly installed, your product meets all safety requirements laid down for this type  
of product category. However special care should be taken around the underneath of the appliance as  
this area is not designed or intended to be touched and may contain sharp or rough edges, that may  
cause injury.  
Enamelled Parts  
– All the enamelled parts must be cleaned with a sponge and soapy water only or other non-abrasive  
products.  
– Dry preferably with a soft cloth. If acid substances such as lemon juice, tomato conserve, vinegar etc. are  
left on the enamel for a long time they will etch it, making it opaque.  
Stainless Steel Surfaces  
– Stainless steel parts should be rinsed with water and dried with a soft cloth.  
– For persistent dirt, use specific non-abrasive products available commercially or a little hot vinegar.  
Note: regular use will cause discolouring around the burners, because of the high flame temperature.  
Control Knob  
– The control knobs may be removed for cleaning but care should be taken not to damage the seal.  
Gas Taps  
– Regular lubrication of the gas taps must only be performed by specialised engineers.  
– If the gas taps are not working properly call the After-Sales Service.  
10  
Burners and Grids  
– These parts can be removed and cleaned with appropriate products.  
– After cleaning, the burners and their flame spreaders must be well dried and correctly replaced.  
– It is very important to check that the burner flame spreader and the cap have been correctly positioned.  
Failure to do so can cause serious problems.  
– Check that the electrode “S” (figs. 7 - 9) is always clean to ensure trouble-free sparking.  
– Check that the sensor “T” (figs. 7 - 9) next to each burner is always clean to ensure correct operation of  
the safety valves.  
– Both the probe and ignition plug must be very carefully cleaned.  
– Note: To avoid damage to the electric ignition do not use it when the burners are not in  
place.  
Correct Positioning of the Burners (Auxiliary, Semi-rapid and Rapid burners)  
– It is very important to check that the burner flame spreader “F” and the cap “C” have been correctly  
positioned (see figs. 7 and 8). Failure to do so can cause serious problems.  
C
F
Ignitor “S”  
Sensor “T”  
Fig. 7  
Fig. 8  
11  
Correct Position of Triple Ring Burner  
The triple ring burner must be correctly positioned (see fig. 9); the burner ribs must be fitted in their  
housing as shown by the arrow.  
The burner correctly positioned must not rotate (fig. 10).  
Then position the cap A and the ring B (figs. 10 - 11)  
Sensor “T”  
Ignitor “S”  
Fig. 9  
A
B
Fig. 10  
Fig. 11  
12  
TIPS FOR INSTALLATION  
Location  
– The appliance may be installed in a kitchen, Kitchen/diner or a bed sitting room, but not in a room or  
space containing a bath or a shower.  
– The appliance must not be installed in a bed-sit room of less than 20m3.  
– The appliance is designed and approved for domestic use only and should not be installed in a commercial,  
semi commercial or communal environment.  
Your product will not be guaranteed if installed in any of the above environments and could affect any  
third party or public liability insurances you may have.  
– This hob should only be installed by a qualified installer. Failure to observe this rule leads to cancellation  
of the guarantee.  
– The appliance must be installed correctly, in compliance with the regulations in force and following the  
manufacturer's instructions.  
– Any repair or maintenance must be performed with the appliance switched off.  
– These appliances have been designed and manufactured to be fitted into heat-resistant units.  
– These hobs are designed to be fitted into 600mm deep kitchen units.  
– The unit walls must not be higher than the working surface and must withstand a temperature of 105°C  
above room temperature.  
– Avoid installation near inflammable materials (e.g. curtains).  
Ventilation Requirements  
– The appliance should be installed into a room or space with an air supply in accordance with BS 5440-2:  
2000.  
– For rooms with a volume of less than 5m3 - permanent ventilation of 100cm2 free area will be  
required.  
– For rooms with a volume of between 5m3 and 10m3 a permanent ventilation of 50cm2 free area will be  
required unless the room has a door which opens directly to the outside air in which case no permanent  
ventilation is required.  
– For rooms with a volume greater than 10m3 - no permanent ventilation is required.  
Important !  
Regardless of room size, all rooms containing the appliance must have direct access to the  
outside air via an openable window or equivalent.  
– Where there are other fuel burning appliances in the same room, BS 5440-2: 2000 should be consulted  
to determine the correct amount of free area ventilation requirements.  
– The above requirements allow also for use of a gas oven and grill but if there are other gas burning  
appliances in the same room, consult a qualified engineer.  
13  
Installation  
Technical Information for the Installer  
In order to install the hob into the kitchen fixture, a hole with the dimensions shown in fig. 12 has to be  
made, bearing in mind the following:  
– Within the unit, between the bottom of the hob and the upper surface of a shelf there must be a  
clearance of at least 30mm.  
– It is absolutely essential that you place a separator between the base of the hob and the built-in unit or  
the oven.  
– The hob must be kept no less than 200mm away from any side wall (fig. 12).  
– The hob must be installed at least 60mm from the wall.  
– There must be a distance of at least  
650mm between the hob and any  
wall cupboard or extractor hood  
positioned immediately above (see  
fig. 14).  
– If the hob is installed over a built-  
in oven, there must be a distance  
of at least 30mm between the two  
appliances. Thetwoappliancesshould  
be connected to the gas supply with  
independent connections  
Fig. 12  
Installation in Kitchen Cabinet with Door  
It is recommended that a 30mm clearance be left  
between the cooktop and the fixture surface (fig. 13).  
Clearance  
Door  
Space for  
connections  
Fig. 13  
Fig. 14  
14  
Applying the Seals  
Turn the cooktop upside down.  
– Spread the longer seal “A” around the left, rear and right sides as shown in figure 15a.  
– With a cutter or a scissors cut the excess seal “C” and retain it for next use (figure 15b).  
– Spread the seal “B” around the left, front and right edges of the cooktop as shown in figure 15c.  
– Spread the seal “C” along the rear edge of the cooktop as shown in figure 15d. Making sure that the  
beginning and the end overlap at the seal “B” (see figure 15e).  
Fig. 15a  
Fig. 15b  
Fig. 15c  
Fig. 15d  
seal C  
seal B  
seal C  
seal A  
seal C  
seal B  
seal A  
Fig. 15e  
15  
Fastening the Installation Brackets  
Each cooktop is provided with an installation kit including brackets and screws for fastening the top to  
fixture panels from 2 to 4 cm thick.  
Turn the cooktop upside down and fasten the brackets “F" and "R” to the appropriate socket holes,  
without tightening the screws “B” for the moment.  
– Make sure that the brackets are fastened as shown in figures 16a, 16b and 16c.  
Fastening the Cooktop  
– Insert the cooktop into the hole and position it correctly.  
– Adjust the position of the brackets “F" and "R” and tighten screws “B” to block the cooktop firmly in  
position.  
– With a sharp cutter or trimmer knife trim the excess sealing material around the edge of the cooktop.  
Take care not to damage the workbench.  
R
R
F
F
Fig. 16a  
Rear side  
Front side  
B
B
R
F
Fig. 16b  
Fig. 16c  
16  
Gas Supply Requirements  
Important Note  
This appliance is supplied for use on NATURAL GAS or LPG (check the gas regulation label attached on  
the appliance).  
– Appliances supplied for use on NATURAL GAS: they are adjusted for this gas only and cannot be used on  
any other gas (LPG) without modification. The appliances are manufactured for conversion to LPG.  
– Appliances supplied for use on LPG: they are adjusted for this gas only and cannot be used on any  
other gas (NATURAL GAS) without modification. The appliances are manufactured for conversion to  
NATURAL GAS.  
If the NATURAL GAS/LPG conversion kit is not supplied with the appliance this kit can be purchased by  
contacting the After-Sales Service.  
Installation and Service Regulations (United Kingdom Only)  
This appliance must be installed and serviced only by a suitably qualified and registered person, and in  
accordance with the current editions of the following standards and regulations or other locally applicable  
regulations:  
– Gas Safety (Installation and Use) Regulations  
– Building Regulations  
– British Standards  
– Regulations for Electrical Installation  
Installation and service of any gas product must be made by a suitably qualified person competent on  
the type of product being installed or serviced and holding a valid certificate of competence for the work  
being carried out. Currently the proof of competence is the Accredited Certification Scheme (ACS) or S/  
NVQ that has been aligned to the ACS.  
It is also a requirement that all businesses or self employed installers are members of a class of person  
approved by the Health and Safety Executive.  
Failure to install the appliance correctly could invalidate any manufacturers warranty and lead to  
prosecution under the above quoted regulation.  
17  
Gas Connection  
The installation of the gas appliance to Natural Gas or LP Gas must be carried out by a suitably  
qualified and registered installer. Installers shall take due account of the provisions of the relevant  
British Standards Code of Practice, the Gas Safety Regulations and the Building Standards (Scotland)  
(Consolidation) Regulations issued by the Scottish Development Department.  
Installation to Natural Gas  
Installation to Natural Gas must conform to the Code of Practice, etc.  
The supply pressure for Natural Gas is 20 mbar.  
The installation must conform to the relevant British Standards.  
Installation to LP Gas  
When operating on Butane gas a supply pressure of 28-30 mbar is required. When using Propane gas a  
supply pressure of 37 mbar is required.  
The installation must conform to the relevant British Standards.  
CDA are not legally able to provide any assistance in the installation of gas appliances except to suitably  
qualified and registered installers. Any suitably qualified and registered fitter requiring help must provide  
name, address and registration number.  
Information supplied will be validated before help is provided.  
Warning:  
Only a suitably qualified and registered installer, also with technical knowledge of electricity  
should install the appliance. He should observe the Regulations and Codes of Practice governing  
such installation of gas appliances.  
Note: It is recommended that the gas connection to the appliance is installed with a flexible  
connecting tube made to BS5386.  
Notes:  
– Flexible hoses can be used where the sited ambient temperature of the hose does not exceed  
70°C. These hoses must be manufactured in accordance with BS669 part 1 and be of the  
correct construction for the type of gas being used.  
– Gas hoses designed for natural gas MUST NOT be used for supplying LPG gas (LPG gas hoses  
can be identified by a either a red band or stripe on the rubber outer coating of the hose).  
The hose should not be crushed or trapped or be in contact with sharp or abrasive edges.  
18  
Gas connection  
Cat: II 2H3+  
The fitting (fig. 17) is made up of:  
– 1 nut A”  
– 1 elbow fitting “C”  
– gasket “F”  
Connection to the Gas Supply  
– Be careful when flexible pipes are used that they do not come into contact with moving parts.  
To maintain the thickness of 3 cm, the hob is fitted with a channel to contain the connection pipe.  
– The gas inlet union can be turned in the direction required after the elbow fitting “C” and nut A”  
connection (figure 17) has been slackened (fig. 18).  
– Never put it in the horizontal or vertical position.  
– Never attempt to turn the elbow “C” without having first slackened off the relative lock nut A.  
– The gasket “F” (fig. 17) guarantees the seal of the gas connection. It is recommended that it be replaced  
whenever it shows even the slightest deformation or imperfection.  
– Using a suitable leak detection fluid solution (e.g. Rocol) check each gas connection one at a  
time by brushing the solution over the connection.  
The presence of bubbles  
will indicate a leak. If there  
is a leak, tighten the fitting  
and then recheck for leaks.  
1/2" G cylindrical  
(ISO 228-1) male  
1/2" G cylindrical  
(ISO 228-1) female  
C
F
A
IMPORTANT! Do not use  
a naked flame to test for  
leaks.  
1/2" G conical  
(ISO 7-1) male  
Fig. 17  
Fig. 18  
If installation is to be carried out using a flexible connector (to BS669), then the following points must  
be adhered to:  
Note: The gas installation pipes and the final connection to the appliance connecting pipe shall be  
sufficient size to maintain the heat output of the appliance as specified under installation.  
1. The appliance flexible connector should not be subject to undue forces, either in normal use whilst  
being connected or disconnected.  
2. The appliance flexible connector should not be subject to excessive heat by direct exposure to flue  
products or by contact with hot surfaces.  
3. The socket into which the plug of the appliance flexible connector fits should be permanently attached  
to a firmly fixed gas installation pipe and positioned such that the hose hangs freely downwards.  
4. The appliance flexible connector should be positioned such that it will not suffer mechanical damage; eg  
abrasion from the surrounding kitchen furniture which may be moved in use, such as a door or drawer,  
or by being trapped by a stability device.  
5. The plug-in connector should be accessible for disconnection after moving the appliance.  
19  
Conversion to Natural Gas or LPG  
Replacing the Burner Injectors  
If the NATURAL GAS/LPG conversion kit is not supplied with the appliance this kit can be purchased by  
contacting the After-Sales Service.  
Choose the injectors to be replaced according to the table below.  
The injector diameter, expressed in hundredths of a millimetre, is marked on the injector body.  
To replace the injectors proceed as follows:  
– Remove the pan supports, the burner caps and flame speaders.  
– Using a wrench, substitute the nozzle injectors “J” (Figs. 19 - 20) with those most suitable for the kind  
of gas for which it is to be used.  
The burners are made in such a way so as not to require regulation of the primary air.  
Auxiliary,  
Semi-Rapid  
and Rapid  
burners  
Triple Ring  
burner  
J
J
Fig. 19  
Fig. 20  
Cat: II 2H 3+  
Table for the Choice of the Injectors  
Burners  
Nominal  
Power  
kW  
Reduced  
Power  
kW  
G30 - 28-30 mbar  
G31 - 37 mbar  
G20 - 20 mbar  
Ø Injector  
Ø Injector  
1/100 mm  
1/100 mm  
Auxiliary (A)  
Semi-Rapid (SR)  
Rapid (R)  
1,00  
1,75  
3,00  
3,50  
0,30  
0,45  
0,75  
1,50  
50  
65  
85  
95  
72 (X)  
97 (Z)  
115 (Y)  
135 (T)  
Triple Ring (TR)  
20  
Regulating the Burner Minimum Setting  
When changing from one type of gas to another, the minimum tap output must also be correct, considering  
that in this position the flame must be about 4 mm long and must remain lit even when the knob is turned  
sharply from the maximum to the minimum position.  
The adjustment is performed with the burner lit, as follows:  
Turn the knob to the minimum position.  
– Remove the tap knob.  
Turn the screw A to the correct setting with a screwdriver (fig. 21).  
For LPG, tighten the adjustment screw completely.  
A
Fig. 21  
Lubrication of the Gas Taps  
The operations must be executed by a qualified technician.  
IMPORTANT: All intervention regarding installation maintenance and conversion of the  
appliance must be fulfilled with original factory parts.  
The manufacturer declines any liability resulting from the non-compliance of this obligation.  
21  
Mains Electricity Connection  
Incorrect installation may be dangerous and the manufacturer can not be held responsible.  
Warning! This appliance must be earthed The manufacturer declines all responsibility for any  
problem caused by failure to observe this rule.  
THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING  
FIXED WIRING VIA A DOUBLE POLE SWITCHED FUSE SPUR OUTLET AND PROTECTED BY A 3A  
FUSE.  
We recommend that the appliance is connected by a qualified electrician, who is a member of the  
N.I.C.E.I.C. and who will comply with the I.E.E. and local regulations.  
The wires in the mains lead of this appliance are coloured in accordance with the following code:  
Green & Yellow = Earth, Blue = Neutral, Brown = Live.  
As the colours of the wires in the mains lead for the appliance  
may not correspond with the coloured markings identifying the  
terminals connecting to the fuse spur, proceed as follows:  
DOUBLE POLE SWITCHED  
FUSE SPUR OUTLET  
The wire which is coloured green and yellow must be  
connected to the terminal marked E (Earth) or coloured  
green.  
The wire which is coloured blue must be connected to the  
terminal marked N (Neutral), or coloured black.  
FUSE ON  
The wire which is coloured brown must be connected to the  
terminal marked L (Live), or coloured red.  
USE A 3 AMP FUSE  
Fig. 22  
Note: Use a 3A Fuse  
Assembly and electrical connection should be carried out by  
specialised personnel.  
When installing this product we recommend you seek the help of  
another individual.  
22  
Appliance Servicing  
CDA provide a quality and effective after-sales service to cover all your servicing needs.  
Please attach your receipt to this page for safekeeping.  
Please help us to help you by having the following information available when booking a service-call:  
1. Model type, make and model – see the product data plate.  
2. Evidence of installation / purchase date  
3. Retailer where appliance was purchased  
4. Clear and concise details of the fault  
5. Full address including postcode and any contact phone numbers  
Contact Telephone Numbers  
CDA Customer Care Department  
Telephone: 01949 862012  
– Fax: 01949 862003  
– Email: [email protected]  
23  
Guarantee  
CDA appliances carry a five-year parts and a one-year labour guarantee.  
CDA will repair or replace any defect or part attributable to faulty material or workmanship. Within the  
first year this will be free of both labour and parts charges. After the first year and within five years, the  
parts will be supplied free of charge provided that the repair is carried out by an agent authorised by CDA  
and the labour will be charged at the commercial rate applicable at the time of repair.  
The appliance must have been installed by a suitably qualified person and in accordance with the  
manufacturer’s instructions and current legislation. The guarantee does not cover faults caused by the  
incorrect fitting of appliances.  
Limit of Cover  
– The guarantee does not cover cosmetic damage e.g. discolouration or oxidisation.  
– Proof of purchase or installation date must be produced before a service-call will be booked.  
– The appliance must be used for domestic purposes only. Appliances used for commercial or professional  
purposes are not covered by the guarantee. Commercial warranty is available at extra cost.  
– The appliance must not be modified or tampered with or repair attempted by any unauthorised  
person.  
– The guarantee does not cover damage caused in transit or by misuse, accident, abuse or neglect.  
– The guarantee does not cover routine maintenance.  
– Use of parts not supplied or recommended by |C|D|A| will invalidate the warranty.  
– Rubber seals, filters, removable glass parts, control knobs and buttons, fuses and light bulbs will need  
replacing periodically and are not covered by the guarantee.  
– Second-hand or reconditioned appliances are not covered by the guarantee.  
The conditions under which this guarantee is offered are in addition to the statutory rights of the domestic  
purchaser and these statutory rights are not affected by this guarantee.  
CDA reserve the right to change specification without prior notice.  
Cod. 1103535 - ß2  
To contact our Customer Care Department, or for Service,  
please contact us on the details below.  
Customer Care Department • The  
Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HY  
T : 01949 862 012 F : 01949 862 003 E : [email protected] W : www.cda.eu  

Grundig M 72 100 A User Manual
GE Profile JP968BC User Manual
Fujitsu Siemens Computers C551 User Manual
Euro Pro TO31 User Manual
Electrolux ZCG5300 User Manual
Electrolux Air O Convect 269014 User Manual
Cypress CY8CTMG120 User Manual
Cisco Systems OL 6109 01 User Manual
Bosch Appliances NEM 95 User Manual
BenQ G900W User Manual