Compaq EK ASIP2 OG D01 User Manual

AlphaServer Intelligent Peripheral  
Platform  
Hardware Owner's Guide  
Part Number: EK-ASIP2-OG. D01  
May 1999  
Compaq Computer Corporation  
Houston, Texas  
FCC Notice: This equipment generates, uses, and may emit radio frequency energy. The equipment has been type  
tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC rules, which are  
designed to provide reasonable protection against such radio frequency interference.  
Operation of this equipment in a residential area may cause interference in which case the user at his own expense will  
be required to take whatever measures may be required to correct the interference.  
Any modifications to this device - unless expressly approved by the manufacturer - can void the user’s authority to  
operate this equipment under part 15 of the FCC rules.  
Note: Additional information on the need to interconnect the device with shielded (data) cables or the need for special  
devices, such as ferrite beads on cables, is required if such means of interference suppression was used in the  
qualification test for the device. This information will vary from device to device and needs to be obtained from the  
EMC group or product manager.  
EMI Notice: This product complies with the following domestic and international standards:  
Domestic: FCC Part 15, Class A  
International: CISPR22 (Europe EN55022 Class A).  
EC Notice:  
Warning! This is a Class A product. In a domestic environment this product may cause radio interference in which  
case the user may be required to take adequate measures.  
Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes  
Rundfunkstörungen auftreten, in welchen Fällen der Benutzer für entsprechende Gegenmaßnahmen verantwortlich ist.  
Attention! Ceci est un produit de Classe A. Dans un environnement domestique, ce produit risque de créer des  
interférences radioélectriques, il appartiendra alors à l'utilisateur de prendre les mesures spécifiques appropriées.  
ACOUSTICS:  
Preliminary declared values per ISO 9296 and ISO 7779:  
Sound Power Level  
LwAd, B  
Sound Pressure Level  
LpAm, dBA (Bystander Positions))  
Idle  
6.5  
6.5  
50  
50  
Operating  
Current values for specific configurations are available from Compaq representatives. 1 B = 10 dBA.  
This is some white text.  
Table of Contents  
Preface  
1 Product Overview  
1.1 Introduction.........................................................................................................................................1–1  
1.2 IP Platform Overview..........................................................................................................................1–1  
1.2.1 IP Simplex System.....................................................................................................................1–2  
1.2.2 IP Duplex System ......................................................................................................................1–2  
1.2.3 Factory Installed Software .........................................................................................................1–3  
1.3 System Features...................................................................................................................................1–4  
1.3.1 User Interfaces...........................................................................................................................1–4  
1.3.2 Alarm Subsystem.......................................................................................................................1–4  
1.3.3 Maintainability ..........................................................................................................................1–4  
1.3.4 Reliability..................................................................................................................................1–4  
1.3.5 Upgrading..................................................................................................................................1–5  
1.3.6 Compaq Computer Corporation and Industry Standards.............................................................1–5  
1.3.6.1 Telecommunications Interfaces........................................................................................15  
1.3.6.2 Safety and Electromagnetic Compatibility .......................................................................1–5  
1.3.7 System Security .........................................................................................................................1–6  
1.4 Required and Optional Hardware.........................................................................................................1–6  
1.4.1 AlphaServer 1000A System .......................................................................................................1–6  
1.4.1.1 Overview .........................................................................................................................1–6  
1.4.1.2 AlphaServer 1000A Required Hardware...........................................................................1–7  
1.4.2 Modular Storage Shelf Subsystem (BA35x-Sx)..........................................................................1–8  
1.4.2.1 Overview .........................................................................................................................1–8  
1.4.2.2 Modular Storage Shelf Optional Hardware.......................................................................1–8  
1.4.3 ISA Bus Expansion Chassis .......................................................................................................1–8  
1.4.3.1 Overview .........................................................................................................................1–8  
1.4.3.2 ISA Bus Expansion Chassis Required and Optional Hardware..........................................1–9  
1.4.4 IP Power Controller Subsystem................................................................................................1–10  
1.4.4.1 Overview .......................................................................................................................1–10  
1.4.4.2 IP Power Controller Options...........................................................................................1–10  
1.4.5 Alarm Indicator Panel..............................................................................................................1–10  
1.4.6 External Hardware Options......................................................................................................1–11  
12 Installing the AlphaServer IP Platform Hardware  
2.1 Introduction.........................................................................................................................................2–1  
2.2 Factory Installed Hardware..................................................................................................................2–1  
2.3 Site Preparation ...................................................................................................................................2–2  
v
2.3.1 Preinstallation Considerations....................................................................................................2–2  
2.4 Hardware Installation...........................................................................................................................2–3  
2.4.1 Installing the IP Platform ...........................................................................................................2–4  
2.4.1.1 Connecting the Network Hardware...................................................................................2–4  
2.4.1.1.1 Connecting Dialogic D/240SC-T1 and DTI/211 T-1 Modules ................................2–5  
2.4.1.1.2 Connecting Dialogic DTI/212 E-1 Modules (75-Ohm) ...........................................2–6  
2.4.1.1.3 Connecting Dialogic DTI/212 E-1 Modules (120-Ohm)..........................................2–6  
2.4.1.1.4 Connecting Dialogic LSI/120 Loop-Start Module...................................................2–7  
2.4.1.2 IP Power Controller..........................................................................................................2–8  
2.4.1.3 User Alarms.....................................................................................................................2–8  
2.4.2 Locking Your System ................................................................................................................2–9  
3 Basic Operation  
3.1 Introduction.........................................................................................................................................3–1  
3.2 Turning on the AlphaServer IP Platform..............................................................................................3–1  
3.2.1 Step I: Power Controller Circuit Breakers ..................................................................................3–1  
3.2.2 Step II: ISA Bus Expansion Chassis...........................................................................................3–1  
3.2.3 Step III: AlphaServer 1000A System..........................................................................................3–1  
3.3 Basic Operation of the IP Platform Subsystem Components ................................................................3–2  
3.3.1 Alarm Indicator Panel................................................................................................................3–2  
3.3.1.1 Replacing Batteries in the Alarm Indicator Panel .............................................................3–4  
3.3.1.2 Dry Contacts ....................................................................................................................3–5  
3.3.2 AlphaServer 1000A System .......................................................................................................3–6  
3.3.3 Modular Storage Shelf BA35x-Sx Subsystem ............................................................................3–7  
3.3.4 ISA Bus Expansion Chassis .......................................................................................................3–8  
4 Reconfiguring the AlphaServer IP Platform  
4.1 Introduction.........................................................................................................................................4–1  
4.2 AlphaServer 1000A System Configurations.........................................................................................4–2  
4.3 ISA Bus Expansion Chassis Configuration...........................................................................................4–3  
4.3.1 Removing and Replacing the Alarm Sensor Module ..................................................................4–3  
4.3.2 Removing and Replacing the AT Bus Expansion Kit .................................................................4–4  
4.4 Modular Storage Shelf BA35x-Sx Subsystem Configuration................................................................4–4  
4.5 Alarm Indicator Panel Configuration ...................................................................................................4–5  
4.5.1 Removing and Replacing the Alarm Indicator Module...............................................................4–5  
5 System Troubleshooting  
5.1 Introduction.........................................................................................................................................5–1  
5.2 AlphaServer 1000A Subsystem............................................................................................................5–2  
5.3 Alarm Indicator Panel..........................................................................................................................5–2  
5.4 ISA Bus Expansion Chassis .................................................................................................................5–3  
5.5 Modular Storage Shelf BA35x-Sx Subsystem ......................................................................................5–3  
5.6 AlphaServer IP Power Controllers .......................................................................................................5–3  
A AlphaServer IP Platform Specifications  
A.1 Physical Dimensions..........................................................................................................................A–1  
A.2 Electrical Specifications ....................................................................................................................A–1  
A.3 System Environmental Specifications ................................................................................................A–2  
A.4 Dry Contact Specifications ................................................................................................................A–3  
A.5 Central Office Compatibility..............................................................................................................A–4  
vi  
B Alarm Input Wiring  
B.1 Alarm Input Wiring Diagram ............................................................................................................. B–1  
B.2 Wiring User Alarm Inputs.................................................................................................................. B–2  
C Field Wiring the -48 Vdc Power Inverter  
C.1 Field Wiring the -48 Vdc Power Controllers ...................................................................................... C–1  
C.1.1 Installing Suitable Field Wiring................................................................................................ C–2  
D AlphaServer IP Platform Duplex System Diagrams  
D.1 Introduction .......................................................................................................................................D–1  
D.2 AlphaServer IP Platform Duplex AC System .....................................................................................D–2  
D.3 AlphaServer IP Platform Duplex DC System .....................................................................................D–4  
E AlphaServer IP Platform Simplex System Diagrams  
E.1 Introduction.........................................................................................................................................E-1  
E.2 AlphaServer IP Platform Simplex AC System.....................................................................................E-2  
E.3 AlphaServer IP Platform Simplex DC System.....................................................................................E-4  
Glossary  
Index  
Figures  
Figure 3-1: Alarm Indicator Panel (Front and Rear View) ........................................................................3–3  
Figure 3-2: Dry Contact Terminal Connectors..........................................................................................3–6  
Figure B-1: Alarm Input Wiring Diagram................................................................................................ B–1  
Figure B-2: Alarm Control Module 8-Pin MJ Connector ......................................................................... B–2  
Figure D–1: IP Platform Duplex AC System Front and Side View...........................................................D–2  
Figure D–2: IP Platform Duplex AC System Rear View..........................................................................D–3  
Figure D–3: IP Platform Duplex DC System Front and Side Views.........................................................D–4  
Figure D–4: IP Platform Duplex DC System Rear View..........................................................................D–5  
Figure E–1: IP Platform Simplex AC System Front and Side View ......................................................... E–2  
Figure E–2: IP Platform Simplex AC System Rear View......................................................................... E–3  
Figure E–3: IP Platform Simplex DC System Front and Side Views........................................................ E–4  
Figure E–4: IP Platform Simplex DC System Rear View......................................................................... E–5  
Tables  
Table 1-1: AlphaServer 1000A Required Hardware..................................................................................1–7  
Table 1-2: Modular Storage Shelf (BA35x-Sx) Optional Hardware ..........................................................1–8  
Table 1-3: ISA Bus Expansion Chassis Required and Optional Hardware.................................................1–9  
Table 1-4: IP Power Controller Options..................................................................................................1–10  
Table 1-5: Alarm Indicator Panel Options ..............................................................................................1–10  
Table 1-6: External Hardware Options....................................................................................................1–11  
Table 2-1: T-1 to D/240SC-T1 Pin Designations ......................................................................................2–5  
Table 2-2: T1 to DTI/211 Pin Designations ..............................................................................................2–5  
vii  
Table 2-3: E-1 to DTI/212 75-Ohm Pin Designations ...............................................................................2–6  
Table 2-4: E-1 to DTI/212 120-Ohm Pin Designations .............................................................................2–6  
Table 2-5: LSI/120 Loop-Start 25-Pin Designations .................................................................................2–7  
Table 2-6: LSI/120 Loop-Start 50-Pin Designations .................................................................................2–8  
Table 3-1: Dry Contact Relay Functional Specification............................................................................3–6  
Table 4-1: SRM Console Configuration Commands .................................................................................4–2  
Table A-1: Physical Dimensions..............................................................................................................A–1  
Table A-2: Electrical Specifications for Each Power Controller...............................................................A–1  
Table A-3: Environmental Specifications ................................................................................................A–2  
Table A-4: Dry Contact Specifications ....................................................................................................A–3  
Table B–1: Alarm Control Module 8-Pin MJ Connector Pinout............................................................... B–2  
Table C–1: Field Wire Recommendations for Each Power Feed.............................................................. C–2  
viii  
Preface  
About This Guide  
The AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide describes how to  
set up, operate, troubleshoot, and maintain an AlphaServer Intelligent Peripheral (IP)  
Platform. If information is available elsewhere, this manual provides a reference to the  
appropriate documentation.  
Intended Audience  
This manual is intended for qualified system managers and technical end users trained in the  
installation and the servicing of computer systems.  
Structure of This Document  
This guide is organized as follows:  
Chapter 1, Product Overview – Describes the basic AlphaServer IP Platform  
configurations, the required and optional hardware, and the factory-installed software.  
Chapter 2, Installing the AlphaServer IP Platform Software – Provides instructions for  
installing the AlphaServer IP Platform hardware.  
Chapter 3, Basic Operation – Describes how to turn on the AlphaServer IP Platform.  
Chapter 4, Reconfiguring the AlphaServer IP Platform – Explains how to reconfigure the  
AlphaServer IP Platform.  
Chapter 5, System Troubleshooting – Provides basic troubleshooting information.  
Appendix A, AlphaServer Platform Specifications – Provides system and environmental  
specifications.  
Appendix B, Alarm Input Wiring – Provides a wiring diagram of all of the alarm inputs and  
wiring information for user alarm inputs.  
Appendix C, Field Wiring the -48 Vdc Power Inverter – Provides field wiring details for  
the -48 Vdc power controllers.  
Appendix D, AlphaServer IP Platform Duplex System Diagrams – Contains diagrams of  
the IP duplex platforms.  
Appendix E, AlphaServer IP Platform Duplex System Diagrams – Contains diagrams of  
the IP simplex platforms.  
The Glossary defines technical terms related to the product.  
The Index locates the main topics in this guide.  
ix  
Conventions  
This document uses the following conventions:  
Convention  
Meaning  
IP  
Describes an industry-standard acronym for Intelligent Peripheral.  
Note  
A note calls the reader’s attention to any item of information that may be of  
special importance.  
Caution  
Warning  
A caution contains information essential to avoid damage to the equipment.  
A warning contains information essential to the safety of personnel.  
Circled numbers provide a link between figures or examples and text.  
Italic type  
Italic type emphasizes important information, indicates variables, and  
indicates complete titles of manuals.  
Related Documentation  
For additional information on the AlphaServer Intelligent Peripheral (IP) Platform subsystem  
components and related software, refer to the documentation in the following table. Order  
numbers may change as documents are revised or updated. Check with your Compaq sales  
representative for additional information.  
Document  
Part Number  
AlphaServer IP Platform  
Intelligent Peripheral Fault Manager for Tru64 UNIX Installation and User's  
Guide  
AA-QN0FD-TE  
AA-QU0JC-TE  
AlphaServer Intelligent Peripheral Platform System Manager's Guide  
AlphaServer 1000A Processor  
AlphaServer 1000A Rackmount Owner’s Guide  
DIGITAL UNIX Installation Guide  
EK-RMNOR-OG  
AA-QTLGB-TE  
EK-KZPSA-UG  
EK-CSEPG-MA  
StorageWorks KZPSA PCI-to-SCSI Adapter User’s Guide  
Site Environmental Preparation Guide  
BA35x-Sx Modular Storage Shelf  
BA350 Modular Storage Shelf Subsystem User’s Guide  
BA350 Modular Storage Shelf Subsystem Configuration Guide  
DWZZB SCSI Signal Converter User’s Guide  
RZ Series Disk Drive Installation Guide - Models RZ35, RZ26, RZ27, RZ28  
-48 Vdc Power Inverter  
EK-BA350-UG  
EK-BA350-CG  
EK-DWZZB-UG  
EK-DRZ01-IG  
DIGITAL 2T-48VDC-xx -48Vdc-to-120Vac Power Inverter Owner's Guide  
ISA Bus Expansion Chassis  
EK-48VDC-OG  
I-Bus 4820 User Manual  
109-40020-00  
Dialogic Voice Hardware Reference  
BX-QLTUA-TE  
BX-QLTTA-TE  
BX-QLTVA-TE  
BX-QLTSA-TE  
Dialogic Network Hardware Reference  
Dialogic VR/160 Hardware Reference  
Dialogic FAX/120 Hardware Reference  
x
1
Product Overview  
1.1 Introduction  
This chapter includes the following topics:  
IP Platform Overview  
IP Platform Features  
IP Platform Required and Optional Hardware  
1.2 IP Platform Overview  
The AlphaServer Intelligent Peripheral (IP) Platform provides a full suite of hardware and  
software components for voice processing, telephony and data communications, management,  
processing, and storage. These components are combined to make a high performance, high  
availability, rackmount-configured IP Platform, that meets certain standards and  
specifications.  
There are two basic AlphaServer IP Platform configurations upon which all platform systems  
are built:  
IP Simplex System  
IP Duplex System  
There may also be custom variations of the IP platform.  
Each rackmount platform requires a console terminal to display all system alarm messages  
and manage alarm conditions.  
Basic AlphaServer IP Platform management functions are designed to ensure the integrity of  
the platform and to allow for the management of the platform itself. The management  
functions include alarming based on critical events, for example; hardware failure, logging of  
events and activities, management of the individual resources, and system security. These  
functions are described in the Intelligent Peripheral Fault Manager for Tru64 UNIX  
Installation and User's Guide.  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 1–1  
Product Overview  
1.2.1 IP Simplex System  
The simplex system is a central office compatible rackmount system intended for Telco  
central office environments. It contains one each of the following components:  
AlphaServer 1000A system running the Compaq Tru64 UNIX (formerly DIGITAL  
UNIX) operating system  
ISA bus expansion chassis  
Alarm indicator panel  
StorageWorks BA35x-Sx mass storage disk drive subsystem (optional)  
Rackmount power controller (120 Vac, 250 Vac, or -48 Vdc models)  
Refer to Appendix E for diagrams of the IP simplex system.  
1.2.2 IP Duplex System  
The duplex rackmount configuration is a central office compatible rackmount system  
intended for Telco central office environments and is suitable for live network  
implementations. The duplex system includes two each of the following components:  
AlphaServer 1000A system running the Tru64 UNIX operating system  
ISA bus expansion chassis  
Alarm indicator panel  
StorageWorks BA35x-Sx mass storage disk drive subsystems (optional) (connected  
together with BN21W-0B and BN21K-XX SCSI bus cables) with disks that can be  
striped and/or mirrored  
Two rackmount power controllers (120 Vac, 250 Vac) or one rackmount power controller  
(-48 Vdc)  
TruCluster software can be ordered separately and is recommended for enhanced availability  
with application-defined failover services.  
Refer to Appendix D for diagrams of the IP duplex system.  
1–2 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
Product Overview  
1.2.3 Factory Installed Software  
The IP platform supplied by Compaq Computer Corporation is delivered to the customer with  
the following factory-installed software:  
Tru64 UNIX operating system  
Dialogic drivers for Tru64 UNIX that offer the following functionality:  
Voice processing (digitization, call control)  
Telephony network interfaces (loop-start, T-1, E-1)  
FAX  
Voice recognition  
ServerWORKS Agent  
Advanced File System Utilities  
Logical Storage Manager  
TruCluster Available Server for Tru64 UNIX (optional)  
Intelligent Peripheral Fault Manager (IPFM) for the Tru64 UNIX operating system  
DECevent Translation Utility  
All systems include the IP Fault Manager software that detects various system events and  
performs pre-configured actions for each event.  
Solution developers can also use the IP Fault Manager to display application alarmed events  
on the IP alarm panel and to log events. A complete description of the IP Fault Manager is  
included in the Intelligent Peripheral Fault Manager for Tru64 UNIX Installation and User's  
Guide.  
For additional information on how to use the factory-installed software, refer to the individual  
product's documentation.  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 1–3  
Product Overview  
1.3 System Features  
This section provides a brief description of the system features of the AlphaServer IP  
Platform.  
1.3.1 User Interfaces  
The AlphaServer IP Platform is designed to work in real-time public networks of  
telecommunications service providers. System and network management activities are  
performed by means of a separate data communications network rather than the telephony  
communications network (for example, voice or signaling). Both graphical user interfaces  
(GUIs) and character cell displays are supported, depending on the interfaces provided by the  
layered products on the IP Platform.  
Command line or character cell displays are used for objects that do not have a GUI, or as a  
supplement to those with a GUI. Command line interfaces can be run over a low-speed dial-  
up modem with minimal communication protocol support.  
1.3.2 Alarm Subsystem  
The alarm subsystem of the AlphaServer IP Platform provides alarming functions to the  
platform. These functions include the following:  
Visual indication of an alarmed event  
Audible indication of an alarmed event  
Programmable external event notification  
Diagnostic capability  
Battery-backup for alarm indicators  
Programmable software interface with interrupt capability  
Dry contacts for remote monitoring of alarms  
The alarm subsystem is comprised of two physical modules: an alarm control module that  
resides on the PCI bus, and an alarm indicator panel, which contains all of the visual and  
audible indicators.  
1.3.3 Maintainability  
All configurations are designed with front access for all user devices contained in the  
AlphaServer 1000A system, the ISA bus expansion chassis, and the modular storage shelf  
BA35x-Sx subsystem. All nonuser devices have rear access.  
The AlphaServer 1000A system and the ISA bus expansion chassis are slide mounted for ease  
of maintenance.  
The BA35x-Sx application storage disks are hot-swappable.  
1.3.4 Reliability  
Each Compaq Computer Corporation component of this system will function reliably over  
time as long as the hardware options used are not altered. All of the Compaq options used in  
the design of this system meet Compaq Computer Corporation standards for reliability.  
However, the reliability of the equipment supplied by other vendors is determined by the  
manufacturer of each device.  
1–4 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
Product Overview  
1.3.5 Upgrading  
Additional hardware and software options may be added to your AlphaServer IP Platform  
components. For a complete list of available options, refer to the individual component's  
documentation listed in the Related Documentation section of the Preface in this guide.  
___________________________ Important _________________________  
FCC and safety review is valid only for options listed in this guide.  
______________________________________________________________  
1.3.6 Compaq Computer Corporation and Industry Standards  
The AlphaServer IP Platform conforms to the industry standards outlined in the following  
subsections.  
1.3.6.1 Telecommunications Interfaces  
The AlphaServer IP Platform conforms to the following telecommunications interface  
standards when Telephony boards are installed:  
T-1 (24-channel, PCM encoded analog) digital network interface  
E-1 (30-channel, PCM encoded analog) digital network interface  
Loop-start signaling  
Ground-start signaling  
E&M wink-start signaling  
1.3.6.2 Safety and Electromagnetic Compatibility  
The AlphaServer IP Platform conforms to the following safety and electromagnetic  
compatibility standards:  
FCC Part 15, Subpart J  
CSA (Canadian Standards Association) C22.2 No. 950-93  
UL (Underwriters Laboratory) 1950  
TUV EN 60950  
CE Class A  
C-Tick Mark  
BSMI  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 1–5  
Product Overview  
1.3.7 System Security  
The AlphaServer IP Platform contains front and rear key locking doors to limit access to  
system components. Each AlphaServer IP Platform comes with a duplicate set of front and  
rear door keys.  
In addition, each AlphaServer 1000A system contains a key to lock the individual processor.  
Refer to the AlphaServer 1000A Rackmount Owner's Guide for instructions on locking the  
AlphaServer 1000A system.  
______________________________ Note ____________________________  
Record the key number for each cabinet door and each CPU. Store this  
information in a safe place; you will need the information if replacement is  
necessary.  
_______________________________________________________________  
1.4 Required and Optional Hardware  
This section provides a brief description of each major component of the AlphaServer IP  
Platform, and lists the required and optional hardware. Contact your Compaq sales  
representative for the current supported options and ordering information.  
1.4.1 AlphaServer 1000A System  
This section describes the AlphaServer 1000A system. It also lists the required hardware for  
this system.  
1.4.1.1 Overview  
The AlphaServer 1000A system is an Alpha uniprocessor server running the Tru64 UNIX  
operating system. A single IP cabinet can support up to two AlphaServer 1000A systems. The  
AlphaServer 1000A system drives all functions within the IP Platform, including voice  
processing, management, and communications. In addition, application, service, and other  
layered software run on an AlphaServer 1000A system. The AlphaServer 1000A offers high  
reliability features such as ECC memory and ECC cache.  
The AlphaServer 1000A system includes:  
9 expansion slots: 7 PCI slots and 2 EISA slots  
256 MB memory, expandable to 1 GB memory  
Integrated Fast-Wide Single-Ended SCSI-2 controller (supports wide and narrow drives)  
Multiple drive bays supporting a 1.44 MB floppy diskette, RRD4 x-xx CD-ROM, 1  
available removable media drive bay, and 3 3.5-inch hard disks  
2 serial ports (9-pin) and one enhanced bi-directional parallel port (25-pin)  
For additional information on the AlphaServer 1000A system features and capabilities, see  
the AlphaServer 1000A Rackmount Owner's Guide.  
1–6 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
Product Overview  
1.4.1.2 AlphaServer 1000A Required Hardware  
Table 1-1 lists the required hardware for the AlphaServer 1000A system. Refer to the  
DIGITAL Systems and Options Catalog for descriptions of optional hardware.  
Table 1-1: AlphaServer 1000A Required Hardware  
Part Number  
Description  
AlphaServer  
Simplex  
Duplex  
Tru64 UNIX  
PB79D-RA  
RM  
1000A 5/500  
1
2
System, includes RX23 floppy drive  
PB7MA-CE  
256 MB memory  
1
1
2
2
2T-VC220-IP  
AT bus expansion kit (EISA/ISA module) Access  
I/O transmitter and receiver modules and 2-meter  
cable  
2T-IPCON-AA  
RZ1CB-BS  
Alarm control module  
1
1
2
2
4.3 GB SCSI hard disk drive  
Note: Each AlphaServer 1000A system in the  
simplex and duplex configurations are  
preconfigured with one wide disk for system files  
and data  
RRD47-AA  
PBXTL-DA  
32 X CD-ROM drive  
1
1
2
2
8.0 GB SCSI 4 mm DAT drive  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 1–7  
Product Overview  
1.4.2 Modular Storage Shelf Subsystem (BA35x-Sx)  
This section provides a brief description of the modular storage shelf subsystem.  
1.4.2.1 Overview  
The StorageWorks disk drive subsystem is a rackmount storage resource provided to solution  
developers and service developers creating applications on the AlphaServer IP Platform. The  
shelves are contained in a separate chassis that provides a flexible capacity for adding and  
hot-swapping disks.  
The shelf is a self-contained unit with embedded backplane routing with two SCSI buses. It  
can be configured for maximum connectivity (1 SCSI bus) or for maximum performance (2  
SCSI buses).  
Each StorageWorks modular storage shelf houses all the application storage disks in a  
rackmount shelf. The following table lists the type of disks that can be used. For additional  
information, see the BA350 Modular Storage Shelf Subsystem Configuration Guide.  
1.4.2.2 Modular Storage Shelf Optional Hardware  
Table 1-2 lists the hardware options for the BA35x-Sx modular storage shelf.  
Table 1-2: Modular Storage Shelf (BA35x-Sx) Optional Hardware  
Part Number  
BA35x-Sx  
Description  
StorageWorks  
Rackmount  
in BA35x-Sx enclosure.  
StorageWorks  
DS-RZ1CF-VW  
DWZZB-VW  
disks for BA35x enclosure. 4.3 GB disks.  
Fast, wide, differential to single ended SCSI converter for BA35x-Sx.  
Terminates SCSI bus at storage unit.  
KZPSA-BB  
H885-AA  
H879-AA  
Fast, wide, differential SCSI controller.  
Tri-link connector block.  
SCSI terminator.  
1.4.3 ISA Bus Expansion Chassis  
This section describes the ISA bus expansion chassis.  
1.4.3.1 Overview  
The I-Bus 4820-2819 enclosure is used as a 20-slot ISA bus expansion chassis for the  
AlphaServer 1000A system. The ISA bus expansion chassis contains all Dialogic voice  
modules for its associated AlphaServer 1000A simplex and duplex systems. The I-Bus 4820-  
2819 enclosure contains an alarm sensor module which monitors temperature, dc power, and  
cooling fan rotation. If any of these reach a point of failure, an alarm signal is sent to the  
AlphaServer 1000A.  
The ISA bus expansion chassis connects to the AlphaServer 1000A system as follows:  
The ISA bus expansion chassis connects to the AlphaServer 1000A EISA bus by means  
of the AT (ISA) bus expansion kit (PN 2T-VC220-IP).  
The ISA bus expansion chassis alarm inputs connect to the AlphaServer 1000A system  
by means of a cable.  
1–8 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
Product Overview  
1.4.3.2 ISA Bus Expansion Chassis Required and Optional Hardware  
The ISA bus expansion chassis connects to the AlphaServer 1000A EISA bus by means of the  
AT (ISA) bus expansion kit. The AT (ISA) bus expansion kit includes transmitter and  
receiver modules and an interconnecting cable. The transmitter module resides in the  
AlphaServer 1000A system, the receiver module resides in the ISA bus expansion chassis,  
and the cable connects both modules.  
Table 1-3 contains the required and optional hardware for the ISA bus expansion chassis. All  
hardware listed in Table 1-3 can be ordered separately as spare parts.  
Table 1-3: ISA Bus Expansion Chassis Required and Optional Hardware  
Part Number  
2T-VC221-IB  
2T-VC220-IP2  
Description  
Simplex Duplex  
ISA bus expansion chassis  
1
2
Access I/O AT bus expansion kit with 2-meter cable  
1
2
2T-LDMOD-AA Load module  
1
2
2T-VC24T-xx1  
2T-VC211-xx1  
2T-VC212-xx1  
2T-VC320-xx1  
2T-VCLSI-xx1  
2T-VC121-xx1  
2T-VCFAX-xx1  
2T-VCF4E-xx1  
Dialogic D/240SC-T1, 24-channel, high-density voice-  
processing and network-interface module  
Opt  
Opt  
Dialogic DTI/211, 24-channel, standard-density, T-1  
network-interface module  
Opt  
Opt  
Opt  
Opt  
Opt  
Opt  
Opt  
Opt  
Opt  
Opt  
Opt  
Opt  
Opt  
Opt  
Dialogic DTI/212, 30-channel, standard-density, E-1  
network-interface module  
Dialogic D/320SC, 32-channel, high-density, voice-  
processing module  
Dialogic LSI/120, 12-channel, standard-density, analog  
loop-start network-interface module  
Dialogic D/121B, 12-channel, standard-density, analog  
loop-start call-processing module  
Dialogic FAX/120, 12-channel, standard-density, FAX  
processing module  
Dialogic VFX/40E, 4-channel, low-density, analog loop-  
start call-processing and 14,400 b/s FAX processing  
module  
2T-VCVRP-xx1  
2T-VCVR4-xx1  
2T-VCVR2-xx1  
Dialogic VRP, 4/8/12/16-channel, standard-density,  
voice-recognition module  
Opt  
Opt  
Opt  
Opt  
Opt  
Opt  
Opt  
Opt  
Dialogic VRM/40, 4-channel, discrete voice-recognition  
daughterboard  
Dialogic VRM/2C, 2-channel, continuous voice-  
recognition daughterboard  
2T-VCDMX-xx1 Dialogic DMX: Digital Matrix Switch connecting up to  
four PCM expansion buses (PEBs)  
1 xx represents a two-letter country code. Contact your Compaq sales representative for additional  
information.  
2 Confirm that there are no cards in the ISA bus expansion chassis that use the Compressed Write  
Timing (“zero-wait-state”) signal. The 2T-VC220-IP option does not service this signal.  
_____________________________ Note____________________________  
The list of supported options is updated on a regular basis. Please contact your  
Compaq sales representative for a current list of supported options.  
______________________________________________________________  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 1–9  
Product Overview  
1.4.4 IP Power Controller Subsystem  
This section briefly describes the IP power controller subsystem.  
1.4.4.1 Overview  
Each rackmount simplex and duplex IP Platform contains one or two power controllers  
located in the bottom rack of the cabinet. Each controller provides power to one ISA bus  
expansion chassis, one BA35x-Sx modular storage shelf, and one AlphaServer 1000A  
processor.  
The AlphaServer IP Platform supports the following power controller models: 120 Vac, 250  
Vac, or -48 Vdc. In addition, each processor and associated voice, storage, and  
communication resource has its own individual power supply.  
Refer to Appendix C for instructions on field wiring the -48 Vdc power controllers for power.  
1.4.4.2 IP Power Controller Options  
Table 1-4 lists the IP power controller options.  
Table 1-4: IP Power Controller Options  
Part Number  
Description  
Simplex Duplex  
H7600-AA  
120 Vac power distribution unit that provides ten (10) ac  
outlets, an attached power cord with an L5-30P plug, an  
on/off circuit breaker, and a power-on light.  
1
2
H7600-DB  
250 Vac power distribution unit that provides twelve (12)  
IEC 320 ac outlets, an attached power cord with an IEC  
309 plug, an on/off circuit breaker, and a power-on light.  
1
2
2T-48VDC-AA  
2T-48VDC-AB  
3 kW (N+1) -48 Vdc power inverter (-48 Vdc to 120 Vac  
dual converter).  
0
1
1
0
2 kW (N+1) -48 Vdc power inverter (-48 Vdc to 120 Vac  
dual converter).  
1.4.5 Alarm Indicator Panel  
The alarm indicator panel provides programmable visual and audible alarm indicators for the  
IP Platform.  
Table 1-5 lists the alarm indicator panel options.  
Table 1-5: Alarm Indicator Panel Options  
Part Number  
2T-IPAIP-CA  
2T-IPAIP-CB  
Description  
Simplex Duplex  
Alarm indicator panel for the simplex IP Platforms.  
Alarm indicator panel for the duplex IP Platforms.  
1
NA  
1
NA  
1–10 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
Product Overview  
1.4.6 External Hardware Options  
Table 1-6 contains external hardware options.  
Table 1-6: External Hardware Options  
Part Number  
Description  
LA75S-AA  
LA75 Plus Companion printer for hardcopy system output  
Personal computer for ServerWORKS  
FR-B16AP-EG  
(or equivalent)  
VT520, VT525  
(or equivalent)  
Console terminal  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 1–11  
is some white text.  
2
Installing the AlphaServer IP Platform Hardware  
2.1 Introduction  
This chapter includes the following topics:  
Factory installed hardware  
Site preparation  
Hardware installation  
2.2 Factory Installed Hardware  
The AlphaServer Intelligent Peripheral (IP) Platform is configured and delivered according  
to customer specification, with all hardware and software factory-installed. It is shipped ready  
for connection to a customer's power source and network hardware.  
_____________________________ Note____________________________  
Value-added Implementation Services (VIS) is available for the AlphaServer IP  
Platform products. VIS provides high-quality integration, test verification, and  
site installation; each process is performed by experienced service personnel. See  
your Compaq sales representative for additional information.  
______________________________________________________________  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 2–1  
Installing the AlphaServer IP Platform Hardware  
2.3 Site Preparation  
This section describes the site-specific installation requirements for the IP Platform.  
_____________________________Caution___________________________  
Review your system warranty. It may require that a Compaq service  
representative install your system to prevent damage to equipment or software.  
_______________________________________________________________  
____________________________ Achtung __________________________  
Überprüfen Sie die Garantie Ihres Systems. Eventuell muß Ihr System, gemäß der  
Garantie, vom Compaq-Kundendienst installiert werden, um Beschädigungen am  
Gerät oder an der Software zu verhindern.  
_______________________________________________________________  
2.3.1 Preinstallation Considerations  
Before you install the AlphaServer IP Platform, ensure that:  
The installation site meets the specifications and environmental conditions listed in  
Appendix A. For more information about planning and preparing the installation site for  
a computer network for a free-standing system, refer to the Site Environmental  
Preparation Guide. (PN EK-CSEPG-MA. Available by calling 1-800-344-4825.)  
The power source is correct for your system, and is one of the following models: 120  
Vac, 250 Vac, or -48 Vdc.  
You have the correct number of T-1, E-1, or loop-start network connections and adequate  
cabling.  
______________________________ Note ____________________________  
The T-1 cable length from the network to the AlphaServer IP Platform cannot  
exceed 199.6 m (655 ft) without a repeater. Do not use a repeater for cable  
lengths less than 199.6 m (655 ft).  
_______________________________________________________________  
The system is located in an area that provides 61 cm (24 in.) clearance from the rear of  
the cabinet, and 76.2 cm (30 in.) from the front of the cabinet for ventilation and  
servicing.  
Personnel are appropriately trained in the installation and operation of this system.  
2–2 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
Installing the AlphaServer IP Platform Hardware  
2.4 Hardware Installation  
This section describes the installation and setup of the IP Platform.  
___________________________ WARNING _________________________  
Only a qualified service person should install the system. A qualified service  
person is an individual who has the technical training and experience to be  
aware of the:  
Hazards to which they are exposed in performing a task  
Measures to minimize the danger to themselves or other persons  
A qualified service person need not be a Compaq service representative.  
______________________________________________________________  
___________________________VORSICHT _________________________  
Das System darf nur von qualifizierten Fachleuten installiert werden.  
Qualifizierte Fachleute sind Personen, die entsprechend technisch geschult  
sind und über die nötige Erfahrung verfügen, um:  
die Gefahren zu erkennen, denen sie bei der Ausführung der Arbeit  
ausgesetzt sein könnten  
die notwendigen Maßnahmen zur Minimierung der Gefahr für sie selbst  
und für andere Personen zu ergreifen.  
Qualifizierte Fachleute sind nicht notwendigerweise Fachleute des Compaq-  
Kundendienstes.  
______________________________________________________________  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 2–3  
Installing the AlphaServer IP Platform Hardware  
2.4.1 Installing the IP Platform  
After you have verified the installation site, install the AlphaServer IP Platform by  
performing the following steps:  
1. Position the cabinet, allowing a 60.96 cm (24 in) minimum rear aisle clearance and a  
76.2 cm (30 in) minimum front aisle clearance.  
2. Level the cabinet using the four-point leveling hardware.  
3. If a -48 Vdc power inverter is installed in the platform, bolt the AlphaServer IP Platform  
to the floor at the cabinet base using the front and rear shipping brackets (and optionally  
at the top, using the appropriate central office conforming hardware). Local codes may  
prohibit bolting the cabinet to the floor if H7600 power distribution units are installed.  
4. Connect to the network hardware (see Section 2.4.1.1).  
5. Connect the IP Platform to the appropriate power supply. See Appendix C for  
instructions on wiring the -48 Vdc controllers if your system has them installed. Refer to  
the power ratings listed on the cabinet part number label located at the rear of the cabinet  
above the door.  
6. Verify the hardware setup. Before you turn on the system, check to ensure that the IP  
Platform is properly secured, and the power controller and network hardware connections  
are correct.  
7. Power up the system. See Section 3.2.  
2.4.1.1 Connecting the Network Hardware  
This section describes how to install Dialogic's voice-processing, voice-recognition, and  
network-interface T-1, E-1, and loop-start modules to the building's network hardware.  
Refer to the Dialogic Network Hardware Reference and the Dialogic Voice Hardware  
Reference for diagrams of the Dialogic modules and for additional information on the  
Dialogic modules. All Dialogic modules are installed in the ISA bus expansion chassis.  
2–4 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
Installing the AlphaServer IP Platform Hardware  
2.4.1.1.1 Connecting Dialogic D/240SC-T1 and DTI/211 T-1 Modules  
On the rear bracket of the D/240SC-T1 and DTI/211 network modules is an RJ-48C jack for  
connecting to the T-1 network. The cabling between this jack and the CSU or other DSX-1  
equipment should be 4-pair telephone line or equivalent. The network interface module of the  
cable should consist of an RJ-48C plug. The user is responsible for supplying an appropriate  
cable for these connections. The pin designations for the network interface module cable end  
for D/240SC-T1 modules are specified in Table 2-1.  
Table 2-1: T-1 to D/240SC-T1 Pin Designations  
Signal  
Pin(s)  
Receive ring: input to network interface module  
Receive tip: input to network interface module  
No connection  
1
2
3, 6  
5
Transmit ring: output from network interface module  
Transmit tip: output from network interface module  
Optional shield  
4
7, 8  
The pin designations for the network interface module cable end for DTI/211 T-1 modules  
are specified in Table 2-2.  
Table 2-2: T1 to DTI/211 Pin Designations  
Signal  
Pin(s)  
Receive ring: input to network interface module  
Receive tip: input to network interface module  
No connection  
1
2
3, 6  
4
Transmit ring: output from network interface module  
Transmit tip: output from network interface module  
Optional shield  
5
7, 8  
Refer to the Dialogic Network Hardware Reference for additional information on DTI/211 T-  
1 modules. Refer to the Dialogic Voice Hardware Reference for additional information on  
D/240SC-T1 modules.  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 2–5  
Installing the AlphaServer IP Platform Hardware  
2.4.1.1.2 Connecting Dialogic DTI/212 E-1 Modules (75-Ohm)  
The Dialogic DTI/212 E-1 modules come in 75-ohm and 120-ohm versions. If you have a  
DTI/212 120-ohm module, see Section 2.4.1.1.3. Refer to the Dialogic Network Hardware  
Reference for additional information on DTI/212 E-1 modules.  
On the rear bracket of the DTI/212 75-ohm module are two BNC-type jacks for connecting to  
the external E-1 network. The cabling between these jacks and the external E-1 network  
should be 75-ohm coaxial. The DTI/212 end of the cable should consist of a BNC-type male  
connector. The user is responsible for supplying an appropriate cable for these connections.  
The pin designations for the DTI/212 75-ohm cable ends are given in Table 2-3.  
Table 2-3: E-1 to DTI/212 75-Ohm Pin Designations  
Signal  
Jack/Pin  
Transmit data: output from DTI/212 (tip)  
Transmit data: output from DTI/212 (ring)  
Receive data: input to DTI/212 (tip)  
Receive data: input to DTI/212 (ring)  
J201A center  
J201A shield  
J201B center  
J201B shield  
To cable the DTI/212 75-ohm module to the E-1 network, follow these steps:  
1. Attach the appropriate end of the E-1 to DTI/212 (receive) cable to jack J201B on the  
rear bracket of the DTI/212 module. Carefully push the BNC connector onto the jack and  
lock by turning a quarter-turn clockwise.  
2. Attach the appropriate end of the DTI/212 to E-1 (transmit) cable to jack J201A on the  
rear bracket of the DTI/212 module. Carefully push the BNC connector onto the jack and  
lock by turning a quarter-turn clockwise.  
2.4.1.1.3 Connecting Dialogic DTI/212 E-1 Modules (120-Ohm)  
On the rear bracket of the DTI/212 120-ohm module is an RJ-48C jack for connecting to the  
external E-1 network. The cabling between this jack and the CSU should be 120-ohm twisted  
pair or equivalent. The DTI/212 120-ohm end of the cable should consist of an RJ-48C plug.  
The user is responsible for supplying an appropriate cable for these connections. The pin  
designations for the DTI/212 120-ohm cable ends are given in Table 2-4.  
Table 2-4: E-1 to DTI/212 120-Ohm Pin Designations  
Signal  
Pin(s)  
Receive ring: input to the DTI/212 120-ohm module  
Receive tip: input to the DTI/212 120-ohm module  
No connection  
1
2
3, 6  
5
Transmit ring: output from the DTI/212 120-ohm module  
Transmit tip: output from the DTI/212 120-ohm module  
Optional shield  
4
7, 8  
2–6 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
Installing the AlphaServer IP Platform Hardware  
To cable the DTI/212 120-ohm module to the E-1 network, follow these steps:  
1. Align the RJ-48C connector at the DTI/212 120-ohm module end of the E-1 to DTI/212  
120-ohm cable with jack J201 on the rear bracket of the DTI/212 module.  
2. Gently push the cable connector into the RJ-48C jack until it snaps into place.  
2.4.1.1.4 Connecting Dialogic LSI/120 Loop-Start Module  
The customer is responsible for supplying additional cabling to connect the LSI/120 network  
interface module to the telephone company lines.  
Refer to the Dialogic Network Hardware Reference for additional information on LSI/120  
modules.  
You can choose from the following connection options:  
Use Compaq's BC22F cable. This cable has a DB-25 connector on one end (to connect to  
the LSI/120), and a 50-pin connector on the other end that provides 12 tip and ring pin  
pairs that are compatible with a standard RJ-21X USOC jack.  
Use Dialogic's SA/120 RJ-11 assembly. This assembly accepts the 50-pin male connector  
from the SA/120 RJ-21 cable and terminates with 12 RJ-11 connectors. This cable allows  
you to connect individual subscriber lines to the LSI/120.  
The pin-out specifications in Table 2-5 and Table 2-6 are for connector P3 on the LSI/120.  
This cable uses a 25-pin female DB-25 connector (Amphenol part number 745495-2 or  
equivalent) on the LSI/120 end, and a 50-pin jack (Amphenol part number 157-72500-3 or  
equivalent) that is compatible with an RJ-21X USOC jack.  
Table 2-5: LSI/120 Loop-Start 25-Pin Designations  
TIP 8  
1
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
RING 12  
TIP 12  
RING 11  
TIP 11  
RING 10  
TIP 10  
TIP 3  
RING 8  
TIP 9  
2
3
RING 9  
TIP 4  
4
5
RING 4  
TIP 7  
6
7
RING 7  
TIP 6  
8
RING 3  
RING 1  
TIP 1  
9
RING 6  
TIP 5  
10  
11  
12  
13  
RING 2  
TIP 2  
RING 5  
RESERVED  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 2–7  
Installing the AlphaServer IP Platform Hardware  
Table 2-6: LSI/120 Loop-Start 50-Pin Designations  
RING 1  
1
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
TIP 1  
RING 2  
2
TIP 2  
RING 3  
3
TIP 3  
RING 4  
4
TIP 4  
RING 5  
5
TIP 5  
RING 6  
6
TIP 6  
RING 7  
7
TIP 7  
RING 8  
8
TIP 8  
RING 9  
9
TIP 9  
RING 10  
RING 11  
RING 12  
RING NC  
RING NC  
RING NC  
RING NC  
RING NC  
RING NC  
RING NC  
RING NC  
RING NC  
RING NC  
RING NC  
RING NC  
RING NC  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
TIP 10  
TIP 11  
TIP 12  
TIP NC  
TIP NC  
TIP NC  
TIP NC  
TIP NC  
TIP NC  
TIP NC  
TIP NC  
TIP NC  
TIP NC  
TIP NC  
TIP NC  
TIP NC  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
2.4.1.2 IP Power Controller  
The AlphaServer IP Platform supports the following power controller models: 120 Vac, 250  
Vac, or -48 Vdc. Each simplex and duplex rackmount system has one or two power  
controllers located in the bottom of the cabinet. Each controller supports one BA35x-Sx, ISA  
bus expansion chassis, and an AlphaServer 1000A system.  
Instructions for wiring the -48 Vdc power controllers to the building's power source are  
included in Appendix C.  
2.4.1.3 User Alarms  
If the AlphaServer IP Platform does not use the -48 Vdc power controller, the user can  
connect up to three external TTL signal alarms to the 8-pin MJ connector on the alarm  
control module. Refer to Appendix B for a pinout of this connector and the Intelligent  
Peripheral Fault Manager for Tru64 UNIX Installation and User's Guide for information on  
configuring these alarms.  
2–8 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
Installing the AlphaServer IP Platform Hardware  
2.4.2 Locking Your System  
The AlphaServer IP Platform is protected by a key lock in the front and rear door panels.  
Duplicate interchangeable sets of keys are provided for both front and rear locks.  
The AlphaServer 1000A system also comes with a set of keys for each CPU.  
_____________________________ Note____________________________  
Store the keys in a safe place. Record the key number for each cabinet door and  
each CPU. Store this information in a safe place; you will need the information if  
replacement is necessary.  
______________________________________________________________  
The AlphaServer 1000A Rackmount Owner's Guide contains additional information about the  
AlphaServer 1000A locking procedure.  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 2–9  
This is some white text.  
3
Basic Operation  
3.1 Introduction  
This chapter describes:  
Turning on the AlphaServer IP Platform  
Basic operation of the IP Platform subsystem components  
3.2 Turning on the AlphaServer IP Platform  
After the AlphaServer IP Platform is properly secured, plugged in, and connected to the  
building's network hardware, you are ready to power up the system. Refer to Appendix D and  
Appendix E for the IP Platform diagrams to assist you in locating the system components.  
3.2.1 Step I: Power Controller Circuit Breakers  
Prior to turning on the circuit breakers for the 120 Vac or 250 Vac controllers, ensure that the  
neon indicator is on, indicating that an ac voltage is present. The -48 Vdc controller does not  
have an indicator for voltage; it should be connected to the -48 Vdc battery/power source  
prior to turning on the circuit breakers.  
To start powering up the AlphaServer IP Platform, switch the circuit breakers at each power  
controller (located in the rear of the cabinet) to the on position. The modular storage shelf  
BA35x-Sx automatically powers up.  
3.2.2 Step II: ISA Bus Expansion Chassis  
To power up the ISA bus expansion chassis, press the On/Off switch on the front of the ISA  
bus expansion chassis. The green ON/Off indicator on the front of the ISA bus expansion  
chassis will illuminate.  
3.2.3 Step III: AlphaServer 1000A System  
Turn the AlphaServer 1000A system on by pressing the On/Off switch on the front of the  
AlphaServer 1000A unit. The green On/Off indicator on the front of the system will  
illuminate.  
At this point in the IP Platform power on sequence, the alarm indicator panel should have the  
green OK LED lit and the status display will contain either a “b” indicating discharged or  
partially charged batteries, or it will be blank.  
As described in the following sections, each subsystem within the IP Platform initiates its  
own self-test at power-up. The following sections describe what a successful power-up of the  
subsystem components looks like.  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 3–1  
Basic Operation  
3.3 Basic Operation of the IP Platform Subsystem Components  
The following sections describe the basic operation of the IP Platform subsystem components.  
3.3.1 Alarm Indicator Panel  
The alarm indicator panel (see Figure 3-1) contains the following:  
Visual indicators  
Audible indicator  
Battery backup logic  
Keep-alive function  
Dry contacts  
Visual Indicators  
The alarm indicator panel has three alarm LED indicators. These LED indicators are defined  
as follows:  
Critical (red LED)  
Major (red LED)  
Minor (amber LED)  
The LED for a particular level of severity will be lit as long as at least one event of that level  
is active. Multiple LEDs may be simultaneously lit.  
The alarm indicator panel has two other indicators used for status information. These are the  
following:  
Status display  
Alarm indicator panel OK LED (green)  
The status display is used to output status as a result of the diagnostic testing and to display  
other status information as shown in the following tables.  
The OK LED is lit after a successful reset and will remain lit until either an unsuccessful reset  
or a loss of battery power occurs.  
Refer to the Intelligent Peripheral Fault Manager For Tru64 UNIX Installation and User's  
Guide for additional information on the alarm indicator panel and fault management.  
______________________________ Note ___________________________  
The alarm indicator panel should not be permanently removed without de-  
configuring it in the Intelligent peripheral Fault Manager (IPFM) config file.  
Refer to the Intelligent Peripheral Fault Manager for Tru64 UNIX Installation  
and User's Guide.  
______________________________________________________________  
3–2 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
Basic Operation  
The following table describes the normal conditions of the alarm indicator panel when the  
AlphaServer 1000A is powered on and the Intelligent Peripheral Fault Manager (IPFM)  
software is running.  
Condition  
OK LED  
Minor Alarm LED Status Display  
Audible Alarm  
Fully discharged batteries On  
Off  
Off  
Off  
“b”  
Off  
Off  
Off  
Fully charged batteries  
On  
On  
“Rotating bar”  
“b”  
Partially charged  
batteries  
Software Diagnostics  
Software Test  
On  
On  
Off  
Off  
“d”  
“t”  
Off  
Off  
If the AlphaServer 1000A system looses power while the IPFM software is running, the  
following table describes the possible conditions of the alarm indicator panel.  
Condition  
OK LED  
Minor Alarm LED Status Display  
Audible Alarm  
Fully discharged batteries Off  
Off  
On  
On  
blank  
“p”  
Off  
On  
On  
Fully charged batteries  
On  
On  
Partially charged  
batteries  
“b”  
Figure 3-1 shows a front and rear view of the alarm indicator panel.  
Figure 3-1: Alarm Indicator Panel (Front and Rear View)  
Front View  
CRITICAL  
A
L P H A  
S
E R V E R I P  
F
A U L T  
M
A N A G E R  
STATUS  
MAJOR  
AUDIBLE  
DISABLE  
MINOR  
OK  
_
_
_
Battery  
_
+
+
Battery  
_
+
+
Battery  
+
Battery  
Battery  
_
J8  
Battery  
Battery  
+
+
J3  
J5  
J4  
J2  
J6  
_
J14  
J15  
J1  
Rear View  
ML014057  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 3–3  
Basic Operation  
Audible Indicator  
The audible indicator has three distinct sounds associated with the three levels of alarming.  
This indicator is controlled by software through the alarm control module or by a disable  
switch on the alarm indicator panel itself. The audible indicator will sound at the level of the  
most severe alarmed event that is currently active. No more than one level of audible alarm  
can be enabled at any one time. The disable switch turns off the current audible alarm until a  
new event occurs that is of equal or greater severity level than the highest level alarm  
currently active, or until the event causing the audible alarm is cleared and another alarmed  
event is pending.  
The three audible alarm levels are defined as follows:  
Critical is two beeps, the first separated from the second by 0.5 seconds or less. This  
double beep pattern is repeated every 1.5 seconds.  
Major is one beep every 1.5 seconds.  
Minor is one beep every 5 seconds.  
Battery Backup Logic  
The battery backup logic is designed to keep the current indicator status functioning for the  
life of the batteries (approximately 60 to 120 minutes) in the event of a power failure. It  
provides an indication if the batteries are low by displaying a “b” in the status display.  
Keep-Alive Function  
The alarm indicator panel houses a timer that is used to ensure that the CPU controlling it is  
still running. The function is enabled by software, which starts a timer. As long as software  
resets the timer before expiration, a “rotating bar” is displayed in the status display, otherwise  
a minor alarm is generated. A minor alarm will also be generated if power to the alarm  
indicator panel is lost and a “p” will be displayed in the status display.  
3.3.1.1 Replacing Batteries in the Alarm Indicator Panel  
The alarm indicator panel contains seven 1.2 V, 600 mA, NICD type AA rechargeable  
batteries that provide battery backup for providing alarm information when the system loses  
power or is turned off. When an alarm indicator panel continuously indicates a low battery  
condition in the absence of a power loss, the batteries should be replaced. These batteries  
should be replaced only with the same type batteries (PN 12-41230-04) or the equivalent  
batteries.  
______________________________ Note ___________________________  
Compaq recommends that batteries be replaced every two to two and a half years  
as preventative maintenance.  
______________________________________________________________  
Perform the following procedure to replace the batteries in an alarm indicator panel:  
1. Power down the AlphaServer 1000A system.  
2. At the front of the cabinet, remove the four screws that secure the alarm indicator panel  
frame to the front rails.  
3. Disconnect the miniature 26-pin cable(s) from the connector(s) on the rear of the alarm  
indicator panel(s).  
4. On the rear of the alarm indicator panel that indicates a low battery condition, remove  
the two screws that secure the miniature 26-pin connector to the rear cover.  
3–4 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
Basic Operation  
5. Remove the three screws from the top edge and the three screws from the bottom edge of  
the alarm indicator panel frame that secure the alarm indicator panel rear cover.  
6. Remove the alarm indicator panel rear cover.  
7. Remove the seven batteries from the battery holders.  
___________________________ WARNING _________________________  
Replace the batteries with the same type (PN 12-41230-04) or an equivalent  
type recommended by the battery manufacturer. Danger of explosion exists if  
batteries are incorrectly replaced. Discard used batteries according to  
battery manufacturer instructions. Be certain to follow any applicable  
country, state, or local statutes for proper battery disposal.  
______________________________________________________________  
___________________________VORSICHT _________________________  
Ersetzen Sie die Batterien nur durch Batterien des gleichen (PN 12-41230-04)  
oder ähnlichen Typs, so wie es vom Hersteller empfohlen wird. Wenn Sie die  
Batterien falsch auswechseln, besteht Explosionsgefahr. Folgen Sie bei der  
Beseitigung der alten Batterien sowohl den Anweisungen des  
Batterieherstellers als auch den jeweiligen länderspezifischen bzw. lokalen  
Vorschriften zur richtigen Batteriebeseitigung.  
______________________________________________________________  
8. Observing proper polarity, install the seven new batteries in the battery holders.  
After installing the new batteries, reverse steps 1 through 6.  
3.3.1.2 Dry Contacts  
The dry contacts terminal connectors (see Figure 3-2) are located on the rear panel of the  
alarm display unit. The four contacts on the input terminal block correspond to Critical,  
Major, Minor, and Audio Shut-off alarm inputs. The output terminal block contacts  
correspond to Critical, Major, Minor, and Audio Shut-off alarm outputs. These terminal  
blocks can be used to connect remote alarm indicators. When an alarm condition occurs, the  
corresponding relay is closed to connect a voltage on the input terminal to a remote alarming  
device on the output terminal. See Table 3-1 for the dry contact relay functional specification.  
Additionally, an audible alarm can be remotely disabled by connecting to the Shut-off Alarm  
contacts. Refer to Appendix A for the dry contact electrical specifications.  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 3–5  
Basic Operation  
Figure 3-2: Dry Contact Terminal Connectors  
A
B
1
2
3
4
5
6
7
8
9
10  
LJ-06572.AI7  
A
Input Terminal Block  
Ext. Critical Alarm  
Ext. Major Alarm  
Ext. Minor Alarm  
Ext. Shut-off Alarm  
Ground  
B
Output Terminal Block  
Critical Alarm  
Major Alarm  
Minor Alarm  
Shut-off Alarm  
Ground  
Table 3-1: Dry Contact Relay Functional Specification  
Relay State  
Power  
Condition  
No alarm  
Critical  
Critical  
Open  
Major  
Open  
Minor  
Open  
On  
Closed  
Open  
Open  
Open  
Minor  
Open  
Closed  
Open  
Major  
Open  
Closed  
Open  
Off  
Battery OK  
Battery NOK  
Open  
Closed  
Closed  
Closed  
Closed  
3.3.2 AlphaServer 1000A System  
Once the AlphaServer 1000A system power is turned on, the screen on the IP Platform  
console displays test codes and initialization messages. When the startup procedure is  
complete, the following occurs:  
The IP Platform console terminal emulation window displays the SRM console prompt  
(>>>).  
The operator control panel on the front of the AlphaServer 1000A system displays the  
message "Model 5/500."  
Boot the Tru64 UNIX system by typing boot at the console prompt. For duplex systems, type  
boot at each processor window. The AlphaServer 1000A system has booted successfully when  
the Tru64 UNIX prompt (#) appears.  
Refer to the DIGITAL UNIX Installation Guide for installation instructions on booting a  
Tru64 UNIX system.  
Refer to the AlphaServer 1000A Rackmount Owner's Guide, for additional information on the  
operation of the AlphaServer 1000A system.  
3–6 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
Basic Operation  
3.3.3 Modular Storage Shelf BA35x-Sx Subsystem  
There may be up to eight StorageWorks building blocks (SBBs) on each modular storage  
shelf BA35x-Sx subsystem. The StorageWorks Building Block (SBB) slots are numbered 0  
through 7 from right to left with the power supply SBB in slot 7. On the IP simplex system,  
the storage SBBs are in slots 0-6. On the duplex system, the available storage SBBs are in  
slots 0-5.  
_____________________________ Note____________________________  
The SCSI address for the SSB device is defined automatically by the SSB slot  
location.  
______________________________________________________________  
After power is supplied to the IP Platform, observe the status LEDs for the following  
successful indications:  
On a power supply SBB, both green status LEDs should be on.  
On a storage SBB, the green device activity LED is either on, flashing, or off. The amber  
device fault LED is off.  
Additional information on the following modular storage shelf BA35x-Sx components can be  
found in the BA350 Modular Storage Shelf Subsystem User’s Guide.  
Component functions  
Shelf status  
Power unit status  
Storage device status  
StorageWorks building block SSB replacement procedures  
Shelf replacement procedures  
Power supplies  
SCSI buses  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 3–7  
Basic Operation  
3.3.4 ISA Bus Expansion Chassis  
The AlphaServer IP Platform supports a variety of voice/telephony options through the  
addition of an ISA bus expansion chassis. The ISA bus expansion chassis is configured with a  
20-slot ISA backplane. The EISA to ISA bridge uses one slot and the remaining 19 slots are  
available for telephony options. The ISA bus expansion chassis has the following  
characteristics:  
Conforms to ISA bus specifications  
Contains an ON/Off power switch for removing power for servicing  
Contains an alarm sensor module for monitoring  
Chassis temperature  
Chassis voltage  
Cooling fan rotation  
Connector for communication with the alarm control module installed in the AlphaServer  
1000A system  
Slide mounted to allow front access to all modules  
430 W power supply to support maximum output voltages (to voice boards) and  
capacities as shown in the following table.  
Voltage  
Amps*  
70  
5
-5  
12  
-12  
1.0  
5.0  
1.0  
* Provided that the maximum  
output power does not exceed the  
power supply rating.  
Contains a load module to provide minimum power supply pre-load (4.2 A @ +5 V).  
This module may be removed from the ISA bus expansion chassis when the minimum  
power supply pre-load can be attained with the installed telephony options.  
Each simplex system contains one ISA bus expansion chassis. Each duplex system contains  
two ISA bus expansion chassis. A connector on the alarm control module is dedicated to  
bringing in physical alarm signals from the ISA bus expansion chassis. Any of the alarm  
events listed above cause the alarm subsystem to generate an interrupt to the system software  
in order to update the alarm database and also send alarm signals to the alarm indicator panel  
for display.  
3–8 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
4
Reconfiguring the AlphaServer IP Platform  
4.1 Introduction  
In order to upgrade the AlphaServer IP Platform or replace defective parts, you need to  
remove and install components within the IP Platform. These components are within the  
individual AlphaServer 1000A system, ISA bus expansion chassis, and modular storage shelf  
BA35x-Sx subsystems. After you change any IP Platform component, you may want to verify  
or modify the system configuration.  
This chapter lists the components of the IP Platform subsystem that may need to be removed  
or installed, and the procedure for viewing and modifying the subsystem configurations using  
the IP Platform console terminal SRM commands.  
Before you attempt to install third-party devices inside your system unit, check with the third-  
party vendor to ensure that your system hardware and operating system software support the  
device.  
____________________________ Caution __________________________  
Static electricity can damage electronic components. Use the antistatic wriststrap  
located in the inside rear cabinet door pocket. Additionally, use an antistatic mat  
when you handle internal components.  
______________________________________________________________  
____________________________Achtung __________________________  
Elektrostatische Entladungen könnten elektronische Komponenten beschädigen.  
Tragen Sie deshalb das Antistatikarmband, das sich in der Tasche an der  
Innenseite der hinteren Gehäuseklappe befindet. Außerdem sollten Sie bei der  
Berührung von internen Komponenten eine Antistatikmatte benutzen.  
______________________________________________________________  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 4–1  
Reconfiguring the AlphaServer IP Platform  
4.2 AlphaServer 1000A System Configurations  
The components of the AlphaServer 1000A system that may need to be replaced or upgraded  
include:  
Storage devices (DAT tape drive, hard disk drive, floppy drive, CD-ROM drive)  
Memory modules  
CPU motherboard  
EISA modules  
DExxx Ethernet controller *  
Access I/O transmitter module (AT bus expansion kit) *  
PCI modules  
* KZPSA-BB SCSI controller (qty=2) (optional)  
* Alarm control module  
Power supply  
The KZPSA-BB PCI-to-SCSI adapter comes with its own utilities diskette that can be used to  
modify the adapter parameters. See the StorageWorks KZPSA PCI-to-SCSI Storage Adapter  
User's Guide for a complete description of the adapter.  
After modifying the above components, and before you boot the Tru64 UNIX operating  
system, you can use the SRM console commands from the IP Platform console terminal to  
examine the system configurations of these components, and make modifications if  
necessary.  
The EISA Configuration Utility (ECU) must be run whenever you add, remove, or move an  
EISA or ISA card within the AlphaServer 1000A system. The ECU is a menu-based utility  
run from the SRM console that provides online help to guide you through the configuration  
process.  
______________________________ Note ___________________________  
Do not move the slot location of the Access I/O transmitter module. Changing the  
location of this module may result in configuration problems.  
______________________________________________________________  
Table 4-1 describes some of the basic SRM console commands used to verify system  
configurations on systems running the Tru64 UNIX operating system.  
Table 4-1: SRM Console Configuration Commands  
Command  
Description  
show config  
show device  
show memory  
setand show  
Displays the buses on the system and the devices found on those buses.  
Displays the devices and controllers on the system.  
Displays the main memory configuration.  
Sets and displays the environment variables.  
Refer to the AlphaServer 1000A Rackmount Owner's Guide for complete instructions on  
using the ECU and SRM console commands, or type helpat the SRM prompt (>>>).  
4–2 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
Reconfiguring the AlphaServer IP Platform  
4.3 ISA Bus Expansion Chassis Configuration  
The ISA bus expansion chassis provides a flexible capacity for adding voice modules of  
varying types based on products from Dialogic. See Section 1.4 for a complete list of  
available ISA bus expansion options.  
Once the Dialogic voice modules are physically installed, you need to configure them by  
running the ECU from the IP Platform console terminal. Use the ECU to register the modules  
with the system hardware, and to reserve the addresses and interrupt request levels (IRQs)  
that are to be used by the modules. The ECU attempts to identify and resolve resource  
conflicts. The ECU may also be used to determine unused I/O ports, shared memory address,  
and IRQs.  
In addition to the Dialogic voice modules, other components within the ISA bus expansion  
chassis include the:  
Fan  
Power supply  
Alarm sensor module  
Access I/O transceiver (AT bus expansion kit)  
For a complete description of installing and configuring the voice-option modules, refer to the  
Dialogic documentation shipped with the option.  
For a complete description of removing and replacing the fan or power supply, refer to the I-  
Bus 4820 User Manual that is shipped with your system.  
Refer to Section 4.3.1 and Section 4.3.2 for complete descriptions of removing and replacing  
the alarm sensor module and the AT bus expansion kit.  
4.3.1 Removing and Replacing the Alarm Sensor Module  
The alarm sensor module is mounted in the drive bay area of the ISA bus expansion chassis.  
The 2T-IPSEN-AA alarm sensor module kit consists of an alarm sensor module, a cable to  
connect the alarm sensor module to the rear bulkhead, and a cable to connect the rear  
bulkhead to the alarm control module in the AlphaServer 1000A.  
Perform the following procedure to remove the alarm sensor module:  
1. Remove power from the ISA bus expansion chassis by pressing the On/Off switch on the  
front of the ISA bus expansion chassis.  
2. Remove the screws that secure the ISA bus expansion chassis to the front rails and extend  
the ISA bus expansion chassis on the slides.  
3. Remove the screws that secure the top cover and remove the top cover from the ISA bus  
expansion chassis.  
4. Disconnect the 6-pin bulkhead cable, the 4-pin power supply cable, and the 2-pin  
temperature sensor cable from the alarm sensor module.  
5. Remove the four screws that secure the alarm sensor module to the standoffs and remove  
the alarm sensor module.  
To replace the alarm sensor module, reverse steps 1 through 5 of the removal procedure.  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 4–3  
Reconfiguring the AlphaServer IP Platform  
4.3.2 Removing and Replacing the AT Bus Expansion Kit  
The 2T-VC220-IP AT bus expansion kit consists of the transmit module installed in the  
AlphaServer 1000A, the receive module installed in the ISA bus expansion chassis, and a 2-  
meter cable that connects the two modules.  
Perform the following procedure to remove the receive module from the ISA bus expansion  
chassis:  
1. Remove power from the ISA bus expansion chassis by pressing the On/Off switch on the  
front of the ISA bus expansion chassis.  
2. Remove the screws that secure the ISA bus expansion chassis to the front rails and extend  
the ISA bus expansion chassis on the slides.  
3. Remove the screws that secure the top cover and remove the top cover from the ISA bus  
expansion chassis.  
4. Disconnect the cable from the receive module.  
5. Remove the hold-down bar from across the top of the modules in the ISA bus expansion  
chassis.  
6. Remove the screw that secures the receive module to the rear bulkhead of the ISA bus  
expansion chassis.  
7. Remove the receive module from the ISA bus expansion chassis.  
To replace the receive module in the ISA bus expansion chassis, reverse steps 1 through 7 of  
the removal procedure. Ensure that the jumpers on the new receive module are set to match  
the jumpers on the receive module being replaced.  
4.4 Modular Storage Shelf BA35x-Sx Subsystem Configuration  
The modular storage shelf BA35x-Sx contains the following components that may need to be  
removed and replaced:  
StorageWorks building blocks (SBBs)  
DWZZB-VW SCSI bus converter  
H885-AA tri-link connector block  
H879-AA SCSI terminator  
Disk drives  
Power supply  
____________________________Important_________________________  
Once a device has been initialized on a SCSI bus with a specific device address,  
moving the device to another bus or changing the device address can cause  
problems.  
______________________________________________________________  
Refer to the BA350 Modular Storage Shelf Subsystem User’s Guide for specific instructions  
on adding and removing StorageWorks components, and setting the correct device addresses.  
4–4 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
Reconfiguring the AlphaServer IP Platform  
4.5 Alarm Indicator Panel Configuration  
The alarm indicator panel provides programmable visual and audible alarm indicators for the  
AlphaServer IP Platform. The alarm indicator panel consists of a metal frame, graphics  
panel(s), and alarm indicator module(s). A cable connects the alarm indicator module to the  
alarm control module that is installed on the AlphaServer 1000A PCI bus.  
4.5.1 Removing and Replacing the Alarm Indicator Module  
The alarm indicator module is mounted inside the alarm indicator panel.  
Perform the following procedure to replace an alarm indicator module:  
1. Power down the AlphaServer 1000A system.  
2. At the front of the cabinet, remove the four screws that secure the alarm indicator panel  
frame to the front rails.  
3. Disconnect the miniature 26-pin cable(s) from the connector(s) on the rear of the alarm  
indicator panel(s).  
4. If attached, disconnect any cables connected to the dry contact terminal blocks.  
5. On the rear of the alarm indicator panel that contains the alarm indicator module to be  
replaced, remove the two screws that secure the miniature 26-pin connector to the rear  
cover.  
6. Remove the three screws from the top edge and the three screws from the bottom edge of  
the alarm indicator panel frame that secure the alarm indicator panel rear cover.  
7. Remove the alarm indicator panel rear cover.  
8. Remove the four screws that secure the alarm indicator module to the alarm indicator  
panel frame.  
To replace the alarm indicator module, reverse steps 1 through 8 of the removal procedure.  
_____________________________ Note____________________________  
The alarm indicator panel should not be permanently removed without de-  
configuring it in the Intelligent Peripheral Fault Manager (IPFM) config file.  
Refer to the Intelligent Peripheral Fault Manager for Tru64 UNIX Installation  
and User's Guide.  
______________________________________________________________  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 4–5  
is some white text.  
5
System Troubleshooting  
5.1 Introduction  
This chapter describes procedures for resolving problems with the components of the  
AlphaServer Intelligent Peripheral (IP) Platform. If the subsystem troubleshooting is  
discussed in another manual, a reference is provided to that documentation.  
Before servicing the system, be aware of any service agreement that exists for your system.  
The agreement helps determine the level of maintenance for self-maintenance customers.  
To correct a problem, locate the troubleshooting section for that component and refer to the  
appropriate documentation. If you cannot correct the problem, report it to your service  
representative.  
___________________________ WARNING _________________________  
Only a qualified service person should install the system. A qualified service  
person is an individual who has the technical training and experience to be  
aware of the:  
Hazards to which they are exposed in performing a task  
Measures to minimize the danger to themselves or other persons  
A qualified service person need not be a Compaq service representative.  
______________________________________________________________  
___________________________VORSICHT _________________________  
Das System darf nur von qualifizierten Fachleuten installiert werden.  
Qualifizierte Fachleute sind Personen, die entsprechend technisch geschult  
sind und über die nötige Erfahrung verfügen, um:  
die Gefahren zu erkennen, denen sie bei der Ausführung der Arbeit  
ausgesetzt sein könnten  
die notwendigen Maßnahmen zur Minimierung der Gefahr für sie selbst  
und für andere Personen zu ergreifen.  
Qualifizierte Fachleute sind nicht notwendigerweise Fachleute des Compaq-  
Kundendienstes.  
______________________________________________________________  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 5–1  
System Troubleshooting  
5.2 AlphaServer 1000A Subsystem  
The AlphaServer 1000A Rackmount Owner's Guide provides the instructions on completing  
the following tasks or resolving these particular problems:  
Confirming that EISA modules or memory modules are properly configured  
Running a diagnostic test of the entire system, showing its status, or terminating the  
testing  
Checking the startup display when you turn on the system  
What to do if:  
The power supply has shut down  
Startup tests do not complete  
The system cannot boot the operating system  
The operating system reports errors, is hung, or crashes  
The system cannot access a mass storage device  
Storage devices are missing from the show device display  
The system indicates network problems, an EISA module is not configured,  
or a PCI module is unseen by the system  
The monitor or the terminal is not working  
The keyboard and mouse are not working  
The system repeatedly shuts down after 10 seconds  
The system does not see or cannot access RAID drives  
The Flash ROM is corrupted and the system cannot access console mode  
5.3 Alarm Indicator Panel  
The alarm indicator panel (see Figure 3-1) uses visual and audio alarm indicators to display  
the status of the IP Platform, including the ISA bus expansion chassis and the -48 Vdc power  
inverter or user alarm inputs. The alarm indicator panel displays alarms as long as it can  
communicate with the alarm control module in the AlphaServer 1000A, or until its backup  
batteries become fully discharged.  
Refer to Section 3.3.1 for a description of the alarm indicator panel alarms and status  
displays. Refer to Section 3.3.1.1 for the procedure for replacing the batteries in the alarm  
indicator panel.  
5–2 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
System Troubleshooting  
5.4 ISA Bus Expansion Chassis  
The ISA bus expansion chassis contains alarm sensors that detect fault conditions and send  
the information to the alarm control module in the AlphaServer 1000A system chassis.  
For a complete description of alarm sensor interaction with the IP Fault Manager software,  
see the Intelligent Peripheral Fault Manager for Tru64 UNIX Installation and User's Guide.  
The status of the Dialogic voice modules is handled at the application level and not by the IP  
Fault Manager software.  
5.5 Modular Storage Shelf BA35x-Sx Subsystem  
The modular storage shelf BA35x-Sx uses the LEDs of its StorageWorks building blocks  
(SBBs) to indicate problems within the power unit, storage devices, and StorageWorks shelf.  
Depending upon the problem, these displays can be flashing, on, or off. The BA350 Modular  
Storage Shelf Subsystem User’s Guide provides instructions on how to interpret these  
displays.  
5.6 AlphaServer IP Power Controllers  
If the power controllers do not function properly, perform the following steps:  
1. Prior to turning on the circuit breakers for the 120 Vac or 250 Vac controllers, ensure  
that the neon indicator is on, indicating that an ac voltage is present. The -48 Vdc  
controller does not have an indicator for voltage. It should be connected to the -48 Vdc  
battery/power source prior to turning on the circuit breakers.  
2. Check that the circuit breakers are on for each of the power controllers installed.  
3. Refer to the DIGITAL 2T-48VDC-xx -48Vdc-to-120Vac Power Inverter Owner’s Guide  
for more troubleshooting information on the -48 Vdc controller.  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 5–3  
is some white text.  
A
AlphaServer IP Platform Specifications  
A.1 Physical Dimensions  
Table A-1 contains the physical dimensions for the AlphaServer Intelligent Peripheral (IP)  
Platform.  
Table A-1: Physical Dimensions  
Dimension  
Depth  
Specification  
96.52 cm (38.0 in.) including doors  
55.88 cm (22.0 in.)  
Width  
Height  
220.01 cm (86.62 in.) including cable trough  
204.77 cm (80.62 in.) without cable trough  
385.56 kg (850 lbs) for fully loaded duplex system  
76.2 cm (30.0 in.) minimum clearance  
60.96 cm (24.0 in.) minimum clearance  
Height  
Weight  
Front aisle  
Rear aisle  
A.2 Electrical Specifications  
Table A-2 contains the electrical specifications for each IP Platform power controller.  
Table A-2: Electrical Specifications for Each Power Controller  
Specification  
Range  
Input voltage  
120 Vac or  
250 Vac or  
-48 Vdc  
Frequency (ac only)  
50-60 Hz  
Input current maximum  
8.0 A at 120 Vac or  
4.0 A at 250 Vac or  
50 A at -48 Vdc  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide A–1  
AlphaServer IP Platform Specifications  
A.3 System Environmental Specifications  
Table A-3 contains the environmental specifications for the AlphaServer IP Platform.  
Table A-3: Environmental Specifications  
Operating/Storage Conditions  
Temperature range  
10°C to 40°C (50°F to 104°F)  
760 mm (29.92 in. Hg)  
20% to 80% (noncondensing)  
2°C (36°F)  
Barometric pressure  
Relative humidity  
Minimum dew point  
Maximum altitude  
2,438 m (8,000 ft)1  
Maximum wet bulb temperature  
28°C (82°F)  
Nonoperating Conditions  
Temperature range  
Relative humidity  
Maximum altitude  
-40°C to 66°C (-40°F to 151°F)  
20% to 85% (noncondensing)  
4,877 m (16,000 ft)1  
1 The maximum allowable operating temperature above 2,438 m (8,000 ft) is reduced  
1.8°C/1,000 m (1.0°F/1,000 ft).  
A–2 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
AlphaServer IP Platform Specifications  
A.4 Dry Contact Specifications  
Table A-4 contains the rating, input, and output specifications for the dry contact terminals.  
Table A-4: Dry Contact Specifications  
Material and Ratings  
Contact material  
Gold-clad silver  
Rating (resistive)  
Maximum switching power  
Maximum switching voltage  
Maximum switching current  
Maximum carrying current  
60 W, 125 VA  
220 Vdc, 250 Vac  
2 A DC, 2 A AC  
3 A DC, 3 A AC  
Input Specifications  
Type  
Relay coil  
Rated input voltage  
Maximum input  
Pick-up voltage  
Drop-out voltage  
Coil resistance  
5 Vdc nominal  
10 Vdc at 50 C  
3.5 Vdc maximum  
0.5 Vdc minimum  
125 ohms, +/- 10%  
Output Specifications  
Contact rating (switching)  
Voltage  
220 Vdc, 250 Vac (maximum)  
2 A DC, 2 A AC (maximum)  
0.6 A, 125 Vac  
Current  
UL/CSA  
0.6 A, 110 Vdc  
2.0 A, 30 Vdc  
Coil rating  
200 mW typically  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide A–3  
AlphaServer IP Platform Specifications  
A.5 Central Office Compatibility  
The AlphaServer IP Platform is intended for deployment in telecommunications central  
office (CO) environments, and is compatible with some of Bellcore's Network Equipment-  
Building Systems (NEBS) specifications TR-NWT-000063.  
Some of the central office compatible (conforming) hardware requirements supported by the  
AlphaServer IP Platform are:  
Simplex or duplex system housed within a single electronic equipment cabinet.  
Cabinet of welded steel construction has locking front and rear doors, bolt-down  
provisions at the cabinet base and top (for use only when a -48 Vdc power inverter is  
installed in the cabinet), four-wheel rugged castor base, four-point leveling, and cable  
egress from top or bottom of the cabinet.  
Integral cable trough attached to the top-rear half of the cabinet, and for larger systems,  
forms a continuous cable trough along the cabinet top-rear.  
120 Vac, 250 Vac, and -48 Vdc dual-feed power models are available for the duplex  
system.  
Weight is 385.56 kg (850 lbs).  
______________________________ Note ____________________________  
Floor loading is approximately 38.56 kg (85 lbs) per square foot according to  
NEBS weight calculation rules. Maximum allowed is 52.16 kg (115 lbs) per  
square foot.  
_______________________________________________________________  
Operating relative humidity of 20% to 80%.  
Acoustic noise is less than 65 dBA.  
Designed to meet earthquake Zone 2.  
Meets FCC Class A specifications.  
Meets UL and other international safety specifications.  
NEBS nonconforming features are:  
Cabinet depth is 96.52 cm (38 in.)  
Printer and terminal are table-top mounted.  
Fire testing not performed.  
Convenience outlets not provided.  
Earthquake testing for Zones 2, 3, and 4 not performed.  
The AlphaServer IP Platform simplex and duplex systems are contained within one single  
bay 177.8 cm (70 in.) panel space cabinet (except for console terminal).  
A–4 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
B
Alarm Input Wiring  
B.1 Alarm Input Wiring Diagram  
The following diagram of the Intelligent Peripheral (IP) duplex platform displays the alarm  
input wiring connections between the ISA bus expansion chassis, the AlphaServer 1000A  
processors, and the alarm indicator panel.  
Figure B-1: Alarm Input Wiring Diagram  
3
4
2
AlphaServer 1000A  
6
5
1
9
8
ISA  
7
ML014035  
Alarm control module installed in  
AlphaServer  
Alarm indicator panel cable  
the  
1000A system  
-48 Vdc power inverter  
Alarm sensor module in the ISA bus  
expansion chassis  
D-sub 25-pin connector  
Inverter alarm cable  
Alarm indicator panel  
D-sub 9-pin connector  
ISA bus expansion chassis alarm cable  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide B–1  
Alarm Input Wiring  
B.2 Wiring User Alarm Inputs  
This section provides information for wiring user TTL signal alarm inputs to the 8-pin MJ  
connector on the alarm control module installed in the AlphaServer 1000A system.  
Figure B-2 shows the 8-pin MJ connector on the alarm control module that is used for  
connecting user alarm inputs.  
Figure B-2: Alarm Control Module 8-Pin MJ Connector  
1
8
ML014036  
Table B–1 provides a pinout listing of the pins on the alarm control module 8-pin MJ  
connector. This table should be used to determine the correct wiring required for user alarm  
inputs.  
Table B–1: Alarm Control Module 8-Pin MJ Connector Pinout  
Pin No.  
Signal  
1
2
3
4
5
6
7
8
Inverter Fail or user input 1 Return  
Inverter Fail or user input 1  
Inverter Minor or user input 2 Return  
Inverter Minor or user input 2  
Inverter Major or user input 3 Return  
Inverter Major or user input 3  
Not used  
Not used  
B–2 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
C
Field Wiring the -48 Vdc Power Inverter  
C.1 Field Wiring the -48 Vdc Power Controllers  
The following sections describe how to field wire the -48 Vdc power controllers.  
___________________________ WARNING _________________________  
The person(s) installing the system should be aware of the 1993 NEC  
(National Electrical Code) requirements for data processing equipment  
installation, Article 645, 645-2. Failure to follow these requirements could  
result in personal injury and damage to the equipment.  
Only a qualified service person should install the system. A qualified service  
person is an individual who has the technical training and experience to be  
aware of the:  
Hazards to which they are exposed in performing a task  
Measures to minimize the danger to themselves or other persons  
A qualified service person need not be a Compaq service representative.  
______________________________________________________________  
___________________________VORSICHT _________________________  
Die Personen, die das System installieren, sollten die Voraussetzungen des  
1993 NEC (National Electrical Code) zur Installation von  
Datenverarbeitungsgeräten, Artikel 645, 645-2, kennen. Mißachtung dieser  
Voraussetzungen könnte zu Personen- und Geräteschaden führen.  
Das System darf nur von qualifizierten Fachleuten installiert werden.  
Qualifizierte Fachleute sind Personen, die entsprechend technisch geschult  
sind und über die nötige Erfahrung verfügen, um:  
die Gefahren zu erkennen, denen sie bei der Ausführung der Arbeit  
ausgesetzt sein könnten  
die notwendigen Maßnahmen zur Minimierung der Gefahr für sie selbst  
und für andere Personen zu ergreifen.  
Qualifizierte Fachleute sind nicht notwendigerweise Fachleute des Compaq-  
Kundendienstes.  
______________________________________________________________  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide C–1  
Field Wiring the -48 Vdc Power Inverter  
C.1.1 Installing Suitable Field Wiring  
The following subsections describe how to install suitable field wiring.  
C.1.1.1 Field Wiring Recommendations  
Table C–1 lists the field wiring recommendations for each side of the -48 Vdc power  
controller. The -48 Vdc power controller has dual power feeds.  
Table C–1: Field Wiring Recommendations for Each Power Feed  
Input Power Requirement  
Input voltage  
-48 Vdc Power Controller  
-48 Vdc  
Input current  
50 A max  
Inrush peak  
6 A max soft start limited  
Recommended wire: Wire should be U/L recognized and CSA certified for 105°C (221°F),  
with insulation rated for 600 Vac. Each of the 3-wire conductors should be a minimum of 6  
AWG stranded.  
____________________________WARNING_________________________  
High energy hazard. Proper precautions required.  
______________________________________________________________  
___________________________ VORSICHT ________________________  
Hochspannungsgefahr. Geeignete Vorsichtsmaßnahmen sind notwendig.  
______________________________________________________________  
C.1.1.2 Installing the Wiring  
1. Strip the wire insulation to approximately 1.27 cm (.50 in.).  
2. Insert the wire into the terminal block as follows:  
a. Observe the wire color/polarity  
Black: -48 Vdc  
White: +48 Vdc  
Green/yellow: Ground  
b. Torque the #10-32 compression screws to 40 to 45 inch-pounds.  
______________________________ Note ___________________________  
Refer to the DIGITAL 2T-48VDC-xx -48Vdc-to-120Vac Power Inverter Owner’s  
Guide for information on powering up and testing the -48 Vdc inverter.  
______________________________________________________________  
C–2 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
D
AlphaServer IP Platform Duplex System  
Diagrams  
D.1 Introduction  
This appendix contains diagrams of the AlphaServer Intelligent Peripheral (IP) Platform  
duplex, ac and dc, systems.  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide D–1  
AlphaServer IP Platform Duplex System Diagrams  
D.2 AlphaServer IP Platform Duplex AC System  
This section contains the front, side, and rear views of the duplex ac system.  
Figure D–1: IP Platform Duplex AC System Front and Side View  
1
2
3
4
5
Front View  
Side View  
ML014018  
Alarm indicator panels  
AlphaServer 1000A  
BA35x-Sx modular storage shelf (optional)  
ISA bus expansion chassis  
H7600 power controller  
D–2 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
AlphaServer IP Platform Duplex System Diagrams  
Figure D–2: IP Platform Duplex AC System Rear View  
1
2
3
4
5
Back View  
ML014028  
Alarm indicator panels  
AlphaServer 1000A  
BA35x-Sx modular storage shelf (optional)  
ISA bus expansion chassis  
H7600 power controller  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide D–3  
AlphaServer IP Platform Duplex System Diagrams  
D.3 AlphaServer IP Platform Duplex DC System  
This section contains the front, side, and rear views of the duplex dc system.  
Figure D–3: IP Platform Duplex DC System Front and Side View  
1
2
3
4
MX ALARM CARD  
AC POWER  
5
Front View  
Side View  
ML014017  
Alarm indicator panels  
AlphaServer 1000A  
BA35x-Sx modular storage shelf (optional)  
ISA bus expansion chassis  
-48 Vdc power controller  
D–4 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
AlphaServer IP Platform Duplex System Diagrams  
Figure D–4: IP Platform Duplex DC System Rear View  
1
2
3
4
_
_
5
_
_
+
+
+
+
Back View  
ML014027  
Alarm indicator panels  
AlphaServer 1000A  
BA35x-Sx modular storage shelf (optional)  
ISA bus expansion chassis  
-48 Vdc power controller  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide D–5  
is some white text.  
E
AlphaServer IP Platform Simplex System  
Diagrams  
E.1 Introduction  
This appendix contains diagrams of the AlphaServer Intelligent Peripheral (IP) Platform  
simplex, ac and dc, systems.  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide E-1  
AlphaServer IP Platform Simplex System Diagrams  
E.2 AlphaServer IP Platform Simplex AC System  
This section contains the front, side, and rear views of the simplex ac system.  
Figure E–1: IP Platform Simplex AC System Front and Side View  
1
2
3
4
5
Front View  
Side View  
ML014022  
Alarm indicator panel  
AlphaServer 1000A  
BA35x-Sx modular storage shelf (optional)  
ISA bus expansion chassis  
H7600 power controller  
E-2 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
AlphaServer IP Platform Simplex System Diagrams  
Figure E–2: IP Platform Simplex AC System Rear View  
1
2
3
4
5
Back View  
ML014032  
Alarm indicator panel  
AlphaServer 1000A  
BA35x-Sx modular storage shelf (optional)  
ISA bus expansion chassis  
H7600 power controller  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide E-3  
AlphaServer IP Platform Simplex System Diagrams  
E.3 AlphaServer IP Platform Simplex DC System  
This section contains the front, side, and rear views of the simplex dc system.  
Figure E–3: IP Platform Simplex DC System Front and Side View  
1
2
3
4
MX ALARM CARD  
AC POWER  
5
Front View  
Side View  
ML014021  
Alarm indicator panel  
AlphaServer 1000A  
BA35x-Sx modular storage shelf (optional)  
ISA bus expansion chassis  
-48 Vdc power controller  
E-4 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
AlphaServer IP Platform Simplex System Diagrams  
Figure E–4: IP Platform Simplex DC System Rear View  
1
2
3
4
5
_
_
_
_
+
+
+
+
Back View  
ML014031  
Alarm indicator panel  
AlphaServer 1000A  
BA35x-Sx modular storage shelf (optional)  
ISA bus expansion chassis  
-48 Vdc power controller  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide E-5  
is some white text.  
Glossary  
10Base-T Ethernet network  
The IEEE standard 802.3-compliant Ethernet products used for local distribution of data.  
These networking products characteristically use twisted-pair cable.  
agent  
A background task running on the object being managed. The agent responds to requests for  
information by the network management station (NMS). The agent is responsible for  
performing get and set operations, for generating the appropriate traps, and for controlling  
access.  
AlphaServer system  
Compaq’s new generation of server systems based on the Alpha 64-bit computing  
architecture.  
ARC  
Advanced RISC Computing (ARC) is the user interface to the console firmware for operating  
systems that expect firmware compliance with the Windows NT Portable Boot Loader  
Specification.  
availability  
The amount of scheduled time that a computing system provides application service during  
the year. Availability is typically measured as a percentage of up time per year.  
backbone  
A core network (usually high speed) to which multiple local area networks (LANs) are  
connected using bridges or routers and over which internetwork traffic can pass.  
backplane  
The main module (board or panel) that connects all of the modules in a computer system.  
boot  
Short for bootstrap. To load an operating system into memory.  
boot device  
The device from which the system bootstrap software is acquired.  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide Glossary-1  
Glossary  
bus  
A collection of many transmission lines or wires. The bus interconnects computer system  
components, providing a communications path for addresses, data, and control information or  
external terminals and systems in a communications network.  
cache  
A small, high-speed memory placed between slower main memory and the processor. A  
cache increases effective memory transfer rates and processor speed. It contains copies of  
data recently used by the processor and fetches several bytes of data from memory in  
anticipation that the processor will access the next sequential series of bytes.  
CD-ROM  
Compact disc read-only memory. The optical removable media used in a compact disc  
reader.  
central processing unit (CPU)  
The unit of the computer that is responsible for interpreting and executing instructions.  
command line interface  
One of two interfaces in the AlphaServer operator interface. The command line interface  
supports OpenVMS and Tru64 UNIX operating systems. It allows you to configure and boot  
the operating system.  
console mode  
The state in which the system and the console terminal operate under the control of the  
console program.  
console subsystem  
The subsystem that provides the user interface for a computer system when the operating  
system is not running.  
console terminal  
The terminal connected to the console subsystem. It is used to start the system and to direct  
activities between the user and the computer system.  
CSU  
Channel service unit. A device that terminates a digital channel on a customer's premises. It  
contains certain line conditioning and equalization functions, and responds to loopback  
commands sent from the central office.  
daughterboard  
A PC module that attaches to the component side of the host module.  
diagnostic program  
A program that finds and corrects problems with a computer system.  
Glossary-2 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
Glossary  
dry contacts  
An electromagnetic device for remote or automatic control that is activated by variation in  
conditions of an electric circuit and that in turn operates other devices (such as switches) in  
the same or a different circuit.  
DSX-1  
Digital Signal Cross-connect Level 1. Any equipment that supports a set of parameters for  
cross-connecting DS-1 (either T-1 or E-1) lines.  
E-1  
Another name given to the CEPT (Conference of European Postal and Telecommunications  
Administrations) digital telephony format. E-1 is a digital transmission channel that carries  
data at the rate of 2.048 Mb/s (DS-1 level).  
ECC  
Error correction code. The code and algorithms used by logic to facilitate error detection and  
correction.  
EISA bus  
Extended Industry Standard Architecture bus. A 32-bit industry-standard I/O bus used  
primarily in high-end PCs and servers.  
EISA Configuration Utility (ECU)  
A feature of the EISA bus that helps you select a conflict- free system configuration and  
perform other system services. The ECU must be run whenever you change, add, or remove  
an EISA or ISA controller.  
environment variables  
The global data structures that can be accessed from console mode. The setting of these data  
structures determines how a system powers up, boots the operating system, and operates.  
Ethernet  
The IEEE 802.3 standard local area network.  
firmware  
The software code stored in hardware.  
initialization  
The sequence of steps that prepare the computer system to start. Initialization occurs after a  
system has been powered up.  
Interrupt request lines (IRQs)  
The bus signals that connect an EISA or ISA module (for example, a disk controller) to the  
system so that the module can get the system's attention by means of an interrupt.  
ISA  
Industry Standard Architecture. An 8-bit or 16-bit industry-standard I/O bus, widely used in  
personal computer products. The EISA bus is a superset of the ISA bus.  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide Glossary-3  
Glossary  
LAN  
Local area network. A high-speed network that supports computers connected over limited  
distances.  
light-emitting diode (LED)  
An indicator of status on an IP subsystem.  
MAC (media access control) address  
A unique 48-bit binary number (usually represented as a 12-digit hexadecimal number)  
encoded in a device's circuitry to identify it on a local area network.  
Maintenance Operations Protocol (MOP) session  
A logical connection using the Maintenance Operations Protocol (MOP).  
mass storage device  
An input/output device on which data is stored. Typical mass storage devices include disks,  
magnetic tapes, and CD-ROM.  
module  
A hardware or software component that is a self-contained system interacting with a larger  
system. Hardware modules are often made to plug into a main system.  
network  
A collection of computers, terminals, and other devices together with the hardware and  
software that enables them to exchange data and share resources over either short or long  
distances.  
network management station (NMS)  
A PC or workstation equipped with an Ethernet, FDDI, or Token Ring network module and  
HUBwatch software that enables it to communicate with and manage network modules.  
network modules  
Modular devices that provide network connectivity or services that can be installed in a  
DEChub backplane or used as standalone devices. Network modules include repeaters,  
concentrators, bridges, brouters, access servers, switches, and SNMP agents.  
PCI  
Peripheral component interconnect. An industry-standard expansion I/O bus that is the  
preferred bus for high-performance I/O options. PCI is available in a 32-bit version and a 64-  
bit version.  
PCI-to-EISA bridge  
The capability to transfer commonly available EISA and ISA options to the PCI bus.  
protocol  
A formal set of rules governing the format, timing, sequencing, and error control of  
exchanged messages on a data network.  
Glossary-4 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
Glossary  
RAID  
Redundant arrays of independent disks. A technique that organizes disk data to improve  
performance and reliability. RAID has three attributes: it is a set of physical disks viewed by  
the user as a single logical device; the user's data is distributed across the physical set of  
drives in a defined manner; and redundant disk capacity is added so that the user's data can be  
recovered even if a drive fails.  
redundant  
Pertaining to duplicate or extra computing components that protect a computing system from  
failure.  
reliability  
The probability that a device or system will not fail to perform its intended functions during a specified  
time.  
repeater  
A level 1 hardware device that restores signal amplitude, waveform, and timing of signals  
before transmission to another network segment.  
SBB  
StorageWorks building block. The basic building block of the StorageWorks product line.  
Any device conforming to shelf mechanical and electrical standards installed in either a 3½-  
inch or 5¼-inch carrier is considered to be an SBB, whether it be a storage device, a power  
supply, or other device.  
SCSI  
Small Computer Systems Interface. An ANSI-standard interface for connecting disks and  
other peripheral devices to computer systems. Some devices are supported under the SCSI-1  
specification; others are supported under the SCSI-2 specification.  
server  
A network node or specialized device that provides and manages access to shared network  
resources, such as hard disks, printers, and software.  
SIMM  
Single in-line memory module. A plug-in module that has RAM chips on one side, and an  
edge connector that matches a socket on the system module.  
Simple Network Management Protocol (SNMP)  
A high-level, standards-based protocol for network management, usually used in TCP/IP  
(Transmission Control Protocol/Internet Protocol) networks.  
SNMP agent  
An entity in a hardware device that executes SNMP requests.  
SRM  
The user interface to console firmware for operating systems that expect firmware  
compliance with the Alpha System Reference Manual (SRM).  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide Glossary-5  
Glossary  
StorageWorks  
Compaq's modular storage subsystem (MSS), which is the core technology of the Alpha  
SCSI-2 mass storage solution. StorageWorks consists of a family of low-cost mass storage  
products that can be configured to meet current and future storage needs.  
system disk  
The device on which the operating system resides.  
T-1  
The digital telephony format used in North America. T-1 is a digital transmission link  
handling 24 voice conversations on two pairs of twisted wires.  
Telnet  
The TCP/IP standard protocol for remote terminal connections. Using Telnet, a user at one  
site can connect to a timesharing system at another site as if the user's terminal is connected  
directly to the remote machine.  
terminal server  
A module that allows a terminal to connect to a network node.  
ThinWire  
Ethernet cabling and technology used for local distribution of data communications.  
ThinWire cabling is thinner than thick wire cabling.  
Transmission Control Protocol (TCP)  
The transport protocol offering a connection-oriented transport service in the Internet suite of  
protocols.  
workgroup  
A configuration that consists of a relatively small number of devices attached to a LAN that  
is isolated from the extended LAN backbone by a bridge or router.  
Glossary-6 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide  
Index  
75-ohm network connections,  
2–6  
75-ohm pin designations, 2–6  
EISA Configuration Utility (ECU),  
4–2  
Electrical specifications, A–1  
Environmental specifications, A–2  
External hardware options, 1–11  
A
Alarm indicator module  
replacing, 4–5  
Alarm indicator panel  
diagram, 3–3  
replacing batteries, 3–4  
troubleshooting, 5–2  
Alarm input wiring diagram, B–1  
Alarm sensor module  
replacing, 4–3  
Alarm subsystem, 1–4  
AlphaServer 1000A system  
components, 4–2  
F
Factory installed  
hardware, 2–1  
software, 1–3  
Fault management, 1–3  
Features  
optional hardware, 1–7  
overview, 1–6  
power-up, 3–1  
alarm subsystem, 1–4  
corporation and industry  
standards, 1–5  
maintainability, 1–4  
reliability, 1–4  
reconfiguring, 4–2  
required hardware, 1–7  
troubleshooting, 5–2  
AT bus expansion kit  
replacing, 4–4  
system security, 1–6  
upgrading, 1–5  
user interfaces, 1–4  
B
H
Hardware  
BA35x-Sx. See Modular storage  
shelf  
factory installed, 2–1  
Hardware setup, 2–3  
connecting network hardware,  
2–4  
D
Dialogic modules, 1–9  
Dry contact specifications, A–3  
Dry contacts, 3–5  
installing the platform, 2–4  
Duplex system. See IP Platform  
ac system diagrams, D–2  
dc system diagrams, D–4  
duplex system, 1–2  
I
Installation  
hardware installation, 2–3  
preinstallation considerations,  
2–2  
E
E-1  
site preparation, 2–2  
Intelligent Peripheral Platform. See  
IP Platform  
120-ohm network connections,  
2–6  
120-ohm pin designations, 2–6  
Interfaces  
telecomminications, 1–5  
user, 1–4  
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide Index-1  
Index  
IP Platform  
Power controller subsystem  
dc field wiring, C–1  
hardware, 1–10  
duplex ac system diagrams, D–  
2
duplex dc system diagrams, D–  
4
overview, 1–10  
troubleshooting, 5–3  
duplex system, 1–2  
electrical specifications, A–1  
environmental specifications,  
A–2  
installing, 2–4  
overview, 1–1  
physical dimensions, A–1  
power controller, 2–8  
power-up, 3–1  
R
Replacing alarm indicator module,  
4–5  
Replacing alarm indicator panel  
batteries, 3–4  
Replacing alarm sensor module, 4–3  
Replacing AT bus expansion kit, 4–4  
reconfiguration, 4–1  
simplex ac system diagrams, E-  
2
simplex dc system diagrams, E-  
4
S
Simplex system. See IP Platform  
ac system diagrams, E-2  
dc system diagrams, E-4  
simplex system, 1–2  
Site preparation, 2–2  
Software  
simplex system, 1–2  
troubleshooting, 5–1  
ISA bus expansion chassis  
components, 4–3  
hardware, 1–9  
factory installed, 1–3  
SRM console commands, 4–2  
Standards  
overview, 1–8  
electromagnetic, 1–5  
safety, 1–5  
reconfiguring, 4–3  
troubleshooting, 5–3  
telecommunications, 1–5  
StorageWorks. See Modular storage  
shelf  
L
Loop-start network  
System security, 1–6  
25-pin designations, 2–7  
50-pin designations, 2–8  
hardware connections, 2–7  
T
T-1  
cable length, 2–2  
M
network connections, 2–5  
pin designations, 2–5  
Telecommunications interfaces, 1–5  
Troubleshooting  
Modular storage shelf  
components, 4–4  
hardware, 1–8  
operation, 3–7  
overview, 1–8  
reconfiguring, 4–4  
status LEDs, 3–7  
troubleshooting, 5–3  
alarm indicator panel, 5–2  
AlphaServer 1000A, 5–2  
IP platform, 5–1  
ISA bus expansion chassis, 5–3  
modular storage shelf, 5–3  
power controller  
N
subsystem, 5–3  
NEBS compatibility, A–4  
U
P
User alarm input wiring, B–2  
User interfaces, 1–4  
Physical dimensions, A–1  
Index-2 DIGITAL AlphaServer Intelligent Peripheral Platform Hardware Owner’s Guide  

Hotpoint GE75DX User Manual
Fisher Paykel CG244 User Manual
FCI Home Appliances COGB33062 User Manual
Euro Pro EUROPRO JO287 User Manual
Electrolux 260702 User Manual
Diamond Multimedia Radeon X1650AGP512 User Manual
Dell POWERVAULT MD3600F User Manual
Dell 1908FP BLK User Manual
AMD Geode SC3200 User Manual
AEG 2490 D User Manual