AlphaServer Intelligent Peripheral
Platform
Hardware Owner's Guide
Part Number: EK-ASIP2-OG. D01
May 1999
Compaq Computer Corporation
Houston, Texas
FCC Notice: This equipment generates, uses, and may emit radio frequency energy. The equipment has been type
tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC rules, which are
designed to provide reasonable protection against such radio frequency interference.
Operation of this equipment in a residential area may cause interference in which case the user at his own expense will
be required to take whatever measures may be required to correct the interference.
Any modifications to this device - unless expressly approved by the manufacturer - can void the user’s authority to
operate this equipment under part 15 of the FCC rules.
Note: Additional information on the need to interconnect the device with shielded (data) cables or the need for special
devices, such as ferrite beads on cables, is required if such means of interference suppression was used in the
qualification test for the device. This information will vary from device to device and needs to be obtained from the
EMC group or product manager.
EMI Notice: This product complies with the following domestic and international standards:
•
•
Domestic: FCC Part 15, Class A
International: CISPR22 (Europe EN55022 Class A).
EC Notice:
Warning! This is a Class A product. In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures.
Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes
Rundfunkstörungen auftreten, in welchen Fällen der Benutzer für entsprechende Gegenmaßnahmen verantwortlich ist.
Attention! Ceci est un produit de Classe A. Dans un environnement domestique, ce produit risque de créer des
interférences radioélectriques, il appartiendra alors à l'utilisateur de prendre les mesures spécifiques appropriées.
ACOUSTICS:
Preliminary declared values per ISO 9296 and ISO 7779:
Sound Power Level
LwAd, B
Sound Pressure Level
LpAm, dBA (Bystander Positions))
Idle
6.5
6.5
50
50
Operating
Current values for specific configurations are available from Compaq representatives. 1 B = 10 dBA.
This is some white text.
Table of Contents
Preface
1 Product Overview
1.1 Introduction.........................................................................................................................................1–1
1.2 IP Platform Overview..........................................................................................................................1–1
1.2.1 IP Simplex System.....................................................................................................................1–2
1.2.2 IP Duplex System ......................................................................................................................1–2
1.2.3 Factory Installed Software .........................................................................................................1–3
1.3 System Features...................................................................................................................................1–4
1.3.1 User Interfaces...........................................................................................................................1–4
1.3.2 Alarm Subsystem.......................................................................................................................1–4
1.3.3 Maintainability ..........................................................................................................................1–4
1.3.4 Reliability..................................................................................................................................1–4
1.3.5 Upgrading..................................................................................................................................1–5
1.3.6 Compaq Computer Corporation and Industry Standards.............................................................1–5
1.3.6.1 Telecommunications Interfaces........................................................................................1–5
1.3.6.2 Safety and Electromagnetic Compatibility .......................................................................1–5
1.3.7 System Security .........................................................................................................................1–6
1.4 Required and Optional Hardware.........................................................................................................1–6
1.4.1 AlphaServer 1000A System .......................................................................................................1–6
1.4.1.1 Overview .........................................................................................................................1–6
1.4.1.2 AlphaServer 1000A Required Hardware...........................................................................1–7
1.4.2 Modular Storage Shelf Subsystem (BA35x-Sx)..........................................................................1–8
1.4.2.1 Overview .........................................................................................................................1–8
1.4.2.2 Modular Storage Shelf Optional Hardware.......................................................................1–8
1.4.3 ISA Bus Expansion Chassis .......................................................................................................1–8
1.4.3.1 Overview .........................................................................................................................1–8
1.4.3.2 ISA Bus Expansion Chassis Required and Optional Hardware..........................................1–9
1.4.4 IP Power Controller Subsystem................................................................................................1–10
1.4.4.1 Overview .......................................................................................................................1–10
1.4.4.2 IP Power Controller Options...........................................................................................1–10
1.4.5 Alarm Indicator Panel..............................................................................................................1–10
1.4.6 External Hardware Options......................................................................................................1–11
12 Installing the AlphaServer IP Platform Hardware
2.1 Introduction.........................................................................................................................................2–1
2.2 Factory Installed Hardware..................................................................................................................2–1
2.3 Site Preparation ...................................................................................................................................2–2
v
2.3.1 Preinstallation Considerations....................................................................................................2–2
2.4 Hardware Installation...........................................................................................................................2–3
2.4.1 Installing the IP Platform ...........................................................................................................2–4
2.4.1.1 Connecting the Network Hardware...................................................................................2–4
2.4.1.1.1 Connecting Dialogic D/240SC-T1 and DTI/211 T-1 Modules ................................2–5
2.4.1.1.2 Connecting Dialogic DTI/212 E-1 Modules (75-Ohm) ...........................................2–6
2.4.1.1.3 Connecting Dialogic DTI/212 E-1 Modules (120-Ohm)..........................................2–6
2.4.1.1.4 Connecting Dialogic LSI/120 Loop-Start Module...................................................2–7
2.4.1.2 IP Power Controller..........................................................................................................2–8
2.4.1.3 User Alarms.....................................................................................................................2–8
2.4.2 Locking Your System ................................................................................................................2–9
3 Basic Operation
3.1 Introduction.........................................................................................................................................3–1
3.2 Turning on the AlphaServer IP Platform..............................................................................................3–1
3.2.1 Step I: Power Controller Circuit Breakers ..................................................................................3–1
3.2.2 Step II: ISA Bus Expansion Chassis...........................................................................................3–1
3.2.3 Step III: AlphaServer 1000A System..........................................................................................3–1
3.3 Basic Operation of the IP Platform Subsystem Components ................................................................3–2
3.3.1 Alarm Indicator Panel................................................................................................................3–2
3.3.1.1 Replacing Batteries in the Alarm Indicator Panel .............................................................3–4
3.3.1.2 Dry Contacts ....................................................................................................................3–5
3.3.2 AlphaServer 1000A System .......................................................................................................3–6
3.3.3 Modular Storage Shelf BA35x-Sx Subsystem ............................................................................3–7
3.3.4 ISA Bus Expansion Chassis .......................................................................................................3–8
4 Reconfiguring the AlphaServer IP Platform
4.1 Introduction.........................................................................................................................................4–1
4.2 AlphaServer 1000A System Configurations.........................................................................................4–2
4.3 ISA Bus Expansion Chassis Configuration...........................................................................................4–3
4.3.1 Removing and Replacing the Alarm Sensor Module ..................................................................4–3
4.3.2 Removing and Replacing the AT Bus Expansion Kit .................................................................4–4
4.4 Modular Storage Shelf BA35x-Sx Subsystem Configuration................................................................4–4
4.5 Alarm Indicator Panel Configuration ...................................................................................................4–5
4.5.1 Removing and Replacing the Alarm Indicator Module...............................................................4–5
5 System Troubleshooting
5.1 Introduction.........................................................................................................................................5–1
5.2 AlphaServer 1000A Subsystem............................................................................................................5–2
5.3 Alarm Indicator Panel..........................................................................................................................5–2
5.4 ISA Bus Expansion Chassis .................................................................................................................5–3
5.5 Modular Storage Shelf BA35x-Sx Subsystem ......................................................................................5–3
5.6 AlphaServer IP Power Controllers .......................................................................................................5–3
A AlphaServer IP Platform Specifications
A.1 Physical Dimensions..........................................................................................................................A–1
A.2 Electrical Specifications ....................................................................................................................A–1
A.3 System Environmental Specifications ................................................................................................A–2
A.4 Dry Contact Specifications ................................................................................................................A–3
A.5 Central Office Compatibility..............................................................................................................A–4
vi
B Alarm Input Wiring
B.1 Alarm Input Wiring Diagram ............................................................................................................. B–1
B.2 Wiring User Alarm Inputs.................................................................................................................. B–2
C Field Wiring the -48 Vdc Power Inverter
C.1 Field Wiring the -48 Vdc Power Controllers ...................................................................................... C–1
C.1.1 Installing Suitable Field Wiring................................................................................................ C–2
D AlphaServer IP Platform Duplex System Diagrams
D.1 Introduction .......................................................................................................................................D–1
D.2 AlphaServer IP Platform Duplex AC System .....................................................................................D–2
D.3 AlphaServer IP Platform Duplex DC System .....................................................................................D–4
E AlphaServer IP Platform Simplex System Diagrams
E.1 Introduction.........................................................................................................................................E-1
E.2 AlphaServer IP Platform Simplex AC System.....................................................................................E-2
E.3 AlphaServer IP Platform Simplex DC System.....................................................................................E-4
Glossary
Index
Figures
Figure 3-1: Alarm Indicator Panel (Front and Rear View) ........................................................................3–3
Figure 3-2: Dry Contact Terminal Connectors..........................................................................................3–6
Figure B-1: Alarm Input Wiring Diagram................................................................................................ B–1
Figure B-2: Alarm Control Module 8-Pin MJ Connector ......................................................................... B–2
Figure D–1: IP Platform Duplex AC System Front and Side View...........................................................D–2
Figure D–2: IP Platform Duplex AC System Rear View..........................................................................D–3
Figure D–3: IP Platform Duplex DC System Front and Side Views.........................................................D–4
Figure D–4: IP Platform Duplex DC System Rear View..........................................................................D–5
Figure E–1: IP Platform Simplex AC System Front and Side View ......................................................... E–2
Figure E–2: IP Platform Simplex AC System Rear View......................................................................... E–3
Figure E–3: IP Platform Simplex DC System Front and Side Views........................................................ E–4
Figure E–4: IP Platform Simplex DC System Rear View......................................................................... E–5
Tables
Table 1-1: AlphaServer 1000A Required Hardware..................................................................................1–7
Table 1-2: Modular Storage Shelf (BA35x-Sx) Optional Hardware ..........................................................1–8
Table 1-3: ISA Bus Expansion Chassis Required and Optional Hardware.................................................1–9
Table 1-4: IP Power Controller Options..................................................................................................1–10
Table 1-5: Alarm Indicator Panel Options ..............................................................................................1–10
Table 1-6: External Hardware Options....................................................................................................1–11
Table 2-1: T-1 to D/240SC-T1 Pin Designations ......................................................................................2–5
Table 2-2: T1 to DTI/211 Pin Designations ..............................................................................................2–5
vii
Table 2-3: E-1 to DTI/212 75-Ohm Pin Designations ...............................................................................2–6
Table 2-4: E-1 to DTI/212 120-Ohm Pin Designations .............................................................................2–6
Table 2-5: LSI/120 Loop-Start 25-Pin Designations .................................................................................2–7
Table 2-6: LSI/120 Loop-Start 50-Pin Designations .................................................................................2–8
Table 3-1: Dry Contact Relay Functional Specification............................................................................3–6
Table 4-1: SRM Console Configuration Commands .................................................................................4–2
Table A-1: Physical Dimensions..............................................................................................................A–1
Table A-2: Electrical Specifications for Each Power Controller...............................................................A–1
Table A-3: Environmental Specifications ................................................................................................A–2
Table A-4: Dry Contact Specifications ....................................................................................................A–3
Table B–1: Alarm Control Module 8-Pin MJ Connector Pinout............................................................... B–2
Table C–1: Field Wire Recommendations for Each Power Feed.............................................................. C–2
viii
Preface
About This Guide
The AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide describes how to
set up, operate, troubleshoot, and maintain an AlphaServer Intelligent Peripheral (IP)
Platform. If information is available elsewhere, this manual provides a reference to the
appropriate documentation.
Intended Audience
This manual is intended for qualified system managers and technical end users trained in the
installation and the servicing of computer systems.
Structure of This Document
This guide is organized as follows:
Chapter 1, Product Overview – Describes the basic AlphaServer IP Platform
configurations, the required and optional hardware, and the factory-installed software.
Chapter 2, Installing the AlphaServer IP Platform Software – Provides instructions for
installing the AlphaServer IP Platform hardware.
Chapter 3, Basic Operation – Describes how to turn on the AlphaServer IP Platform.
Chapter 4, Reconfiguring the AlphaServer IP Platform – Explains how to reconfigure the
AlphaServer IP Platform.
Chapter 5, System Troubleshooting – Provides basic troubleshooting information.
Appendix A, AlphaServer Platform Specifications – Provides system and environmental
specifications.
Appendix B, Alarm Input Wiring – Provides a wiring diagram of all of the alarm inputs and
wiring information for user alarm inputs.
Appendix C, Field Wiring the -48 Vdc Power Inverter – Provides field wiring details for
the -48 Vdc power controllers.
Appendix D, AlphaServer IP Platform Duplex System Diagrams – Contains diagrams of
the IP duplex platforms.
Appendix E, AlphaServer IP Platform Duplex System Diagrams – Contains diagrams of
the IP simplex platforms.
The Glossary defines technical terms related to the product.
The Index locates the main topics in this guide.
ix
Conventions
This document uses the following conventions:
Convention
Meaning
IP
Describes an industry-standard acronym for Intelligent Peripheral.
Note
A note calls the reader’s attention to any item of information that may be of
special importance.
Caution
Warning
➊
A caution contains information essential to avoid damage to the equipment.
A warning contains information essential to the safety of personnel.
Circled numbers provide a link between figures or examples and text.
Italic type
Italic type emphasizes important information, indicates variables, and
indicates complete titles of manuals.
Related Documentation
For additional information on the AlphaServer Intelligent Peripheral (IP) Platform subsystem
components and related software, refer to the documentation in the following table. Order
numbers may change as documents are revised or updated. Check with your Compaq sales
representative for additional information.
Document
Part Number
AlphaServer IP Platform
Intelligent Peripheral Fault Manager for Tru64 UNIX Installation and User's
Guide
AA-QN0FD-TE
AA-QU0JC-TE
AlphaServer Intelligent Peripheral Platform System Manager's Guide
AlphaServer 1000A Processor
AlphaServer 1000A Rackmount Owner’s Guide
DIGITAL UNIX Installation Guide
EK-RMNOR-OG
AA-QTLGB-TE
EK-KZPSA-UG
EK-CSEPG-MA
StorageWorks KZPSA PCI-to-SCSI Adapter User’s Guide
Site Environmental Preparation Guide
BA35x-Sx Modular Storage Shelf
BA350 Modular Storage Shelf Subsystem User’s Guide
BA350 Modular Storage Shelf Subsystem Configuration Guide
DWZZB SCSI Signal Converter User’s Guide
RZ Series Disk Drive Installation Guide - Models RZ35, RZ26, RZ27, RZ28
-48 Vdc Power Inverter
EK-BA350-UG
EK-BA350-CG
EK-DWZZB-UG
EK-DRZ01-IG
DIGITAL 2T-48VDC-xx -48Vdc-to-120Vac Power Inverter Owner's Guide
ISA Bus Expansion Chassis
EK-48VDC-OG
I-Bus 4820 User Manual
109-40020-00
Dialogic Voice Hardware Reference
BX-QLTUA-TE
BX-QLTTA-TE
BX-QLTVA-TE
BX-QLTSA-TE
Dialogic Network Hardware Reference
Dialogic VR/160 Hardware Reference
Dialogic FAX/120 Hardware Reference
x
1
Product Overview
1.1 Introduction
This chapter includes the following topics:
•
•
•
IP Platform Overview
IP Platform Features
IP Platform Required and Optional Hardware
1.2 IP Platform Overview
The AlphaServer Intelligent Peripheral (IP) Platform provides a full suite of hardware and
software components for voice processing, telephony and data communications, management,
processing, and storage. These components are combined to make a high performance, high
availability, rackmount-configured IP Platform, that meets certain standards and
specifications.
There are two basic AlphaServer IP Platform configurations upon which all platform systems
are built:
•
•
IP Simplex System
IP Duplex System
There may also be custom variations of the IP platform.
Each rackmount platform requires a console terminal to display all system alarm messages
and manage alarm conditions.
Basic AlphaServer IP Platform management functions are designed to ensure the integrity of
the platform and to allow for the management of the platform itself. The management
functions include alarming based on critical events, for example; hardware failure, logging of
events and activities, management of the individual resources, and system security. These
functions are described in the Intelligent Peripheral Fault Manager for Tru64 UNIX
Installation and User's Guide.
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 1–1
Product Overview
1.2.1 IP Simplex System
The simplex system is a central office compatible rackmount system intended for Telco
central office environments. It contains one each of the following components:
•
AlphaServer 1000A system running the Compaq Tru64 UNIX (formerly DIGITAL
UNIX) operating system
•
•
•
•
ISA bus expansion chassis
Alarm indicator panel
StorageWorks BA35x-Sx mass storage disk drive subsystem (optional)
Rackmount power controller (120 Vac, 250 Vac, or -48 Vdc models)
Refer to Appendix E for diagrams of the IP simplex system.
1.2.2 IP Duplex System
The duplex rackmount configuration is a central office compatible rackmount system
intended for Telco central office environments and is suitable for live network
implementations. The duplex system includes two each of the following components:
•
•
•
•
AlphaServer 1000A system running the Tru64 UNIX operating system
ISA bus expansion chassis
Alarm indicator panel
StorageWorks BA35x-Sx mass storage disk drive subsystems (optional) (connected
together with BN21W-0B and BN21K-XX SCSI bus cables) with disks that can be
striped and/or mirrored
•
Two rackmount power controllers (120 Vac, 250 Vac) or one rackmount power controller
(-48 Vdc)
TruCluster software can be ordered separately and is recommended for enhanced availability
with application-defined failover services.
Refer to Appendix D for diagrams of the IP duplex system.
1–2 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
Product Overview
1.2.3 Factory Installed Software
The IP platform supplied by Compaq Computer Corporation is delivered to the customer with
the following factory-installed software:
•
•
Tru64 UNIX operating system
Dialogic drivers for Tru64 UNIX that offer the following functionality:
−
−
−
−
Voice processing (digitization, call control)
Telephony network interfaces (loop-start, T-1, E-1)
FAX
Voice recognition
•
•
•
•
•
•
ServerWORKS Agent
Advanced File System Utilities
Logical Storage Manager
TruCluster Available Server for Tru64 UNIX (optional)
Intelligent Peripheral Fault Manager (IPFM) for the Tru64 UNIX operating system
DECevent Translation Utility
All systems include the IP Fault Manager software that detects various system events and
performs pre-configured actions for each event.
Solution developers can also use the IP Fault Manager to display application alarmed events
on the IP alarm panel and to log events. A complete description of the IP Fault Manager is
included in the Intelligent Peripheral Fault Manager for Tru64 UNIX Installation and User's
Guide.
For additional information on how to use the factory-installed software, refer to the individual
product's documentation.
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 1–3
Product Overview
1.3 System Features
This section provides a brief description of the system features of the AlphaServer IP
Platform.
1.3.1 User Interfaces
The AlphaServer IP Platform is designed to work in real-time public networks of
telecommunications service providers. System and network management activities are
performed by means of a separate data communications network rather than the telephony
communications network (for example, voice or signaling). Both graphical user interfaces
(GUIs) and character cell displays are supported, depending on the interfaces provided by the
layered products on the IP Platform.
Command line or character cell displays are used for objects that do not have a GUI, or as a
supplement to those with a GUI. Command line interfaces can be run over a low-speed dial-
up modem with minimal communication protocol support.
1.3.2 Alarm Subsystem
The alarm subsystem of the AlphaServer IP Platform provides alarming functions to the
platform. These functions include the following:
•
•
•
•
•
•
•
Visual indication of an alarmed event
Audible indication of an alarmed event
Programmable external event notification
Diagnostic capability
Battery-backup for alarm indicators
Programmable software interface with interrupt capability
Dry contacts for remote monitoring of alarms
The alarm subsystem is comprised of two physical modules: an alarm control module that
resides on the PCI bus, and an alarm indicator panel, which contains all of the visual and
audible indicators.
1.3.3 Maintainability
All configurations are designed with front access for all user devices contained in the
AlphaServer 1000A system, the ISA bus expansion chassis, and the modular storage shelf
BA35x-Sx subsystem. All nonuser devices have rear access.
The AlphaServer 1000A system and the ISA bus expansion chassis are slide mounted for ease
of maintenance.
The BA35x-Sx application storage disks are hot-swappable.
1.3.4 Reliability
Each Compaq Computer Corporation component of this system will function reliably over
time as long as the hardware options used are not altered. All of the Compaq options used in
the design of this system meet Compaq Computer Corporation standards for reliability.
However, the reliability of the equipment supplied by other vendors is determined by the
manufacturer of each device.
1–4 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
Product Overview
1.3.5 Upgrading
Additional hardware and software options may be added to your AlphaServer IP Platform
components. For a complete list of available options, refer to the individual component's
documentation listed in the Related Documentation section of the Preface in this guide.
___________________________ Important _________________________
FCC and safety review is valid only for options listed in this guide.
______________________________________________________________
1.3.6 Compaq Computer Corporation and Industry Standards
The AlphaServer IP Platform conforms to the industry standards outlined in the following
subsections.
1.3.6.1 Telecommunications Interfaces
The AlphaServer IP Platform conforms to the following telecommunications interface
standards when Telephony boards are installed:
•
•
•
•
•
T-1 (24-channel, PCM encoded analog) digital network interface
E-1 (30-channel, PCM encoded analog) digital network interface
Loop-start signaling
Ground-start signaling
E&M wink-start signaling
1.3.6.2 Safety and Electromagnetic Compatibility
The AlphaServer IP Platform conforms to the following safety and electromagnetic
compatibility standards:
•
•
•
•
•
•
•
FCC Part 15, Subpart J
CSA (Canadian Standards Association) C22.2 No. 950-93
UL (Underwriters Laboratory) 1950
TUV EN 60950
CE Class A
C-Tick Mark
BSMI
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 1–5
Product Overview
1.3.7 System Security
The AlphaServer IP Platform contains front and rear key locking doors to limit access to
system components. Each AlphaServer IP Platform comes with a duplicate set of front and
rear door keys.
In addition, each AlphaServer 1000A system contains a key to lock the individual processor.
Refer to the AlphaServer 1000A Rackmount Owner's Guide for instructions on locking the
AlphaServer 1000A system.
______________________________ Note ____________________________
Record the key number for each cabinet door and each CPU. Store this
information in a safe place; you will need the information if replacement is
necessary.
_______________________________________________________________
1.4 Required and Optional Hardware
This section provides a brief description of each major component of the AlphaServer IP
Platform, and lists the required and optional hardware. Contact your Compaq sales
representative for the current supported options and ordering information.
1.4.1 AlphaServer 1000A System
This section describes the AlphaServer 1000A system. It also lists the required hardware for
this system.
1.4.1.1 Overview
The AlphaServer 1000A system is an Alpha uniprocessor server running the Tru64 UNIX
operating system. A single IP cabinet can support up to two AlphaServer 1000A systems. The
AlphaServer 1000A system drives all functions within the IP Platform, including voice
processing, management, and communications. In addition, application, service, and other
layered software run on an AlphaServer 1000A system. The AlphaServer 1000A offers high
reliability features such as ECC memory and ECC cache.
The AlphaServer 1000A system includes:
•
•
•
•
9 expansion slots: 7 PCI slots and 2 EISA slots
256 MB memory, expandable to 1 GB memory
Integrated Fast-Wide Single-Ended SCSI-2 controller (supports wide and narrow drives)
Multiple drive bays supporting a 1.44 MB floppy diskette, RRD4 x-xx CD-ROM, 1
available removable media drive bay, and 3 3.5-inch hard disks
•
2 serial ports (9-pin) and one enhanced bi-directional parallel port (25-pin)
For additional information on the AlphaServer 1000A system features and capabilities, see
the AlphaServer 1000A Rackmount Owner's Guide.
1–6 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
Product Overview
1.4.1.2 AlphaServer 1000A Required Hardware
Table 1-1 lists the required hardware for the AlphaServer 1000A system. Refer to the
DIGITAL Systems and Options Catalog for descriptions of optional hardware.
Table 1-1: AlphaServer 1000A Required Hardware
Part Number
Description
AlphaServer
Simplex
Duplex
Tru64 UNIX
PB79D-RA
RM
1000A 5/500
1
2
System, includes RX23 floppy drive
PB7MA-CE
256 MB memory
1
1
2
2
2T-VC220-IP
AT bus expansion kit (EISA/ISA module) Access
I/O transmitter and receiver modules and 2-meter
cable
2T-IPCON-AA
RZ1CB-BS
Alarm control module
1
1
2
2
4.3 GB SCSI hard disk drive
Note: Each AlphaServer 1000A system in the
simplex and duplex configurations are
preconfigured with one wide disk for system files
and data
RRD47-AA
PBXTL-DA
32 X CD-ROM drive
1
1
2
2
8.0 GB SCSI 4 mm DAT drive
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 1–7
Product Overview
1.4.2 Modular Storage Shelf Subsystem (BA35x-Sx)
This section provides a brief description of the modular storage shelf subsystem.
1.4.2.1 Overview
The StorageWorks disk drive subsystem is a rackmount storage resource provided to solution
developers and service developers creating applications on the AlphaServer IP Platform. The
shelves are contained in a separate chassis that provides a flexible capacity for adding and
hot-swapping disks.
The shelf is a self-contained unit with embedded backplane routing with two SCSI buses. It
can be configured for maximum connectivity (1 SCSI bus) or for maximum performance (2
SCSI buses).
Each StorageWorks modular storage shelf houses all the application storage disks in a
rackmount shelf. The following table lists the type of disks that can be used. For additional
information, see the BA350 Modular Storage Shelf Subsystem Configuration Guide.
1.4.2.2 Modular Storage Shelf Optional Hardware
Table 1-2 lists the hardware options for the BA35x-Sx modular storage shelf.
Table 1-2: Modular Storage Shelf (BA35x-Sx) Optional Hardware
Part Number
BA35x-Sx
Description
StorageWorks
Rackmount
in BA35x-Sx enclosure.
StorageWorks
DS-RZ1CF-VW
DWZZB-VW
disks for BA35x enclosure. 4.3 GB disks.
Fast, wide, differential to single ended SCSI converter for BA35x-Sx.
Terminates SCSI bus at storage unit.
KZPSA-BB
H885-AA
H879-AA
Fast, wide, differential SCSI controller.
Tri-link connector block.
SCSI terminator.
1.4.3 ISA Bus Expansion Chassis
This section describes the ISA bus expansion chassis.
1.4.3.1 Overview
The I-Bus 4820-2819 enclosure is used as a 20-slot ISA bus expansion chassis for the
AlphaServer 1000A system. The ISA bus expansion chassis contains all Dialogic voice
modules for its associated AlphaServer 1000A simplex and duplex systems. The I-Bus 4820-
2819 enclosure contains an alarm sensor module which monitors temperature, dc power, and
cooling fan rotation. If any of these reach a point of failure, an alarm signal is sent to the
AlphaServer 1000A.
The ISA bus expansion chassis connects to the AlphaServer 1000A system as follows:
•
The ISA bus expansion chassis connects to the AlphaServer 1000A EISA bus by means
of the AT (ISA) bus expansion kit (PN 2T-VC220-IP).
•
The ISA bus expansion chassis alarm inputs connect to the AlphaServer 1000A system
by means of a cable.
1–8 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
Product Overview
1.4.3.2 ISA Bus Expansion Chassis Required and Optional Hardware
The ISA bus expansion chassis connects to the AlphaServer 1000A EISA bus by means of the
AT (ISA) bus expansion kit. The AT (ISA) bus expansion kit includes transmitter and
receiver modules and an interconnecting cable. The transmitter module resides in the
AlphaServer 1000A system, the receiver module resides in the ISA bus expansion chassis,
and the cable connects both modules.
Table 1-3 contains the required and optional hardware for the ISA bus expansion chassis. All
hardware listed in Table 1-3 can be ordered separately as spare parts.
Table 1-3: ISA Bus Expansion Chassis Required and Optional Hardware
Part Number
2T-VC221-IB
2T-VC220-IP2
Description
Simplex Duplex
ISA bus expansion chassis
1
2
Access I/O AT bus expansion kit with 2-meter cable
1
2
2T-LDMOD-AA Load module
1
2
2T-VC24T-xx1
2T-VC211-xx1
2T-VC212-xx1
2T-VC320-xx1
2T-VCLSI-xx1
2T-VC121-xx1
2T-VCFAX-xx1
2T-VCF4E-xx1
Dialogic D/240SC-T1, 24-channel, high-density voice-
processing and network-interface module
Opt
Opt
Dialogic DTI/211, 24-channel, standard-density, T-1
network-interface module
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Dialogic DTI/212, 30-channel, standard-density, E-1
network-interface module
Dialogic D/320SC, 32-channel, high-density, voice-
processing module
Dialogic LSI/120, 12-channel, standard-density, analog
loop-start network-interface module
Dialogic D/121B, 12-channel, standard-density, analog
loop-start call-processing module
Dialogic FAX/120, 12-channel, standard-density, FAX
processing module
Dialogic VFX/40E, 4-channel, low-density, analog loop-
start call-processing and 14,400 b/s FAX processing
module
2T-VCVRP-xx1
2T-VCVR4-xx1
2T-VCVR2-xx1
Dialogic VRP, 4/8/12/16-channel, standard-density,
voice-recognition module
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Dialogic VRM/40, 4-channel, discrete voice-recognition
daughterboard
Dialogic VRM/2C, 2-channel, continuous voice-
recognition daughterboard
2T-VCDMX-xx1 Dialogic DMX: Digital Matrix Switch connecting up to
four PCM expansion buses (PEBs)
1 xx represents a two-letter country code. Contact your Compaq sales representative for additional
information.
2 Confirm that there are no cards in the ISA bus expansion chassis that use the Compressed Write
Timing (“zero-wait-state”) signal. The 2T-VC220-IP option does not service this signal.
_____________________________ Note____________________________
The list of supported options is updated on a regular basis. Please contact your
Compaq sales representative for a current list of supported options.
______________________________________________________________
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 1–9
Product Overview
1.4.4 IP Power Controller Subsystem
This section briefly describes the IP power controller subsystem.
1.4.4.1 Overview
Each rackmount simplex and duplex IP Platform contains one or two power controllers
located in the bottom rack of the cabinet. Each controller provides power to one ISA bus
expansion chassis, one BA35x-Sx modular storage shelf, and one AlphaServer 1000A
processor.
The AlphaServer IP Platform supports the following power controller models: 120 Vac, 250
Vac, or -48 Vdc. In addition, each processor and associated voice, storage, and
communication resource has its own individual power supply.
Refer to Appendix C for instructions on field wiring the -48 Vdc power controllers for power.
1.4.4.2 IP Power Controller Options
Table 1-4 lists the IP power controller options.
Table 1-4: IP Power Controller Options
Part Number
Description
Simplex Duplex
H7600-AA
120 Vac power distribution unit that provides ten (10) ac
outlets, an attached power cord with an L5-30P plug, an
on/off circuit breaker, and a power-on light.
1
2
H7600-DB
250 Vac power distribution unit that provides twelve (12)
IEC 320 ac outlets, an attached power cord with an IEC
309 plug, an on/off circuit breaker, and a power-on light.
1
2
2T-48VDC-AA
2T-48VDC-AB
3 kW (N+1) -48 Vdc power inverter (-48 Vdc to 120 Vac
dual converter).
0
1
1
0
2 kW (N+1) -48 Vdc power inverter (-48 Vdc to 120 Vac
dual converter).
1.4.5 Alarm Indicator Panel
The alarm indicator panel provides programmable visual and audible alarm indicators for the
IP Platform.
Table 1-5 lists the alarm indicator panel options.
Table 1-5: Alarm Indicator Panel Options
Part Number
2T-IPAIP-CA
2T-IPAIP-CB
Description
Simplex Duplex
Alarm indicator panel for the simplex IP Platforms.
Alarm indicator panel for the duplex IP Platforms.
1
NA
1
NA
1–10 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
Product Overview
1.4.6 External Hardware Options
Table 1-6 contains external hardware options.
Table 1-6: External Hardware Options
Part Number
Description
LA75S-AA
LA75 Plus Companion printer for hardcopy system output
Personal computer for ServerWORKS
FR-B16AP-EG
(or equivalent)
VT520, VT525
(or equivalent)
Console terminal
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 1–11
is some white text.
2
Installing the AlphaServer IP Platform Hardware
2.1 Introduction
This chapter includes the following topics:
•
•
•
Factory installed hardware
Site preparation
Hardware installation
2.2 Factory Installed Hardware
The AlphaServer Intelligent Peripheral (IP) Platform is configured and delivered according
to customer specification, with all hardware and software factory-installed. It is shipped ready
for connection to a customer's power source and network hardware.
_____________________________ Note____________________________
Value-added Implementation Services (VIS) is available for the AlphaServer IP
Platform products. VIS provides high-quality integration, test verification, and
site installation; each process is performed by experienced service personnel. See
your Compaq sales representative for additional information.
______________________________________________________________
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 2–1
Installing the AlphaServer IP Platform Hardware
2.3 Site Preparation
This section describes the site-specific installation requirements for the IP Platform.
_____________________________Caution___________________________
Review your system warranty. It may require that a Compaq service
representative install your system to prevent damage to equipment or software.
_______________________________________________________________
____________________________ Achtung __________________________
Überprüfen Sie die Garantie Ihres Systems. Eventuell muß Ihr System, gemäß der
Garantie, vom Compaq-Kundendienst installiert werden, um Beschädigungen am
Gerät oder an der Software zu verhindern.
_______________________________________________________________
2.3.1 Preinstallation Considerations
Before you install the AlphaServer IP Platform, ensure that:
•
The installation site meets the specifications and environmental conditions listed in
Appendix A. For more information about planning and preparing the installation site for
a computer network for a free-standing system, refer to the Site Environmental
Preparation Guide. (PN EK-CSEPG-MA. Available by calling 1-800-344-4825.)
•
•
The power source is correct for your system, and is one of the following models: 120
Vac, 250 Vac, or -48 Vdc.
You have the correct number of T-1, E-1, or loop-start network connections and adequate
cabling.
______________________________ Note ____________________________
The T-1 cable length from the network to the AlphaServer IP Platform cannot
exceed 199.6 m (655 ft) without a repeater. Do not use a repeater for cable
lengths less than 199.6 m (655 ft).
_______________________________________________________________
•
•
The system is located in an area that provides 61 cm (24 in.) clearance from the rear of
the cabinet, and 76.2 cm (30 in.) from the front of the cabinet for ventilation and
servicing.
Personnel are appropriately trained in the installation and operation of this system.
2–2 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
Installing the AlphaServer IP Platform Hardware
2.4 Hardware Installation
This section describes the installation and setup of the IP Platform.
___________________________ WARNING _________________________
Only a qualified service person should install the system. A qualified service
person is an individual who has the technical training and experience to be
aware of the:
•
•
Hazards to which they are exposed in performing a task
Measures to minimize the danger to themselves or other persons
A qualified service person need not be a Compaq service representative.
______________________________________________________________
___________________________VORSICHT _________________________
Das System darf nur von qualifizierten Fachleuten installiert werden.
Qualifizierte Fachleute sind Personen, die entsprechend technisch geschult
sind und über die nötige Erfahrung verfügen, um:
•
die Gefahren zu erkennen, denen sie bei der Ausführung der Arbeit
ausgesetzt sein könnten
•
die notwendigen Maßnahmen zur Minimierung der Gefahr für sie selbst
und für andere Personen zu ergreifen.
Qualifizierte Fachleute sind nicht notwendigerweise Fachleute des Compaq-
Kundendienstes.
______________________________________________________________
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 2–3
Installing the AlphaServer IP Platform Hardware
2.4.1 Installing the IP Platform
After you have verified the installation site, install the AlphaServer IP Platform by
performing the following steps:
1. Position the cabinet, allowing a 60.96 cm (24 in) minimum rear aisle clearance and a
76.2 cm (30 in) minimum front aisle clearance.
2. Level the cabinet using the four-point leveling hardware.
3. If a -48 Vdc power inverter is installed in the platform, bolt the AlphaServer IP Platform
to the floor at the cabinet base using the front and rear shipping brackets (and optionally
at the top, using the appropriate central office conforming hardware). Local codes may
prohibit bolting the cabinet to the floor if H7600 power distribution units are installed.
4. Connect to the network hardware (see Section 2.4.1.1).
5. Connect the IP Platform to the appropriate power supply. See Appendix C for
instructions on wiring the -48 Vdc controllers if your system has them installed. Refer to
the power ratings listed on the cabinet part number label located at the rear of the cabinet
above the door.
6. Verify the hardware setup. Before you turn on the system, check to ensure that the IP
Platform is properly secured, and the power controller and network hardware connections
are correct.
7. Power up the system. See Section 3.2.
2.4.1.1 Connecting the Network Hardware
This section describes how to install Dialogic's voice-processing, voice-recognition, and
network-interface T-1, E-1, and loop-start modules to the building's network hardware.
Refer to the Dialogic Network Hardware Reference and the Dialogic Voice Hardware
Reference for diagrams of the Dialogic modules and for additional information on the
Dialogic modules. All Dialogic modules are installed in the ISA bus expansion chassis.
2–4 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
Installing the AlphaServer IP Platform Hardware
2.4.1.1.1 Connecting Dialogic D/240SC-T1 and DTI/211 T-1 Modules
On the rear bracket of the D/240SC-T1 and DTI/211 network modules is an RJ-48C jack for
connecting to the T-1 network. The cabling between this jack and the CSU or other DSX-1
equipment should be 4-pair telephone line or equivalent. The network interface module of the
cable should consist of an RJ-48C plug. The user is responsible for supplying an appropriate
cable for these connections. The pin designations for the network interface module cable end
for D/240SC-T1 modules are specified in Table 2-1.
Table 2-1: T-1 to D/240SC-T1 Pin Designations
Signal
Pin(s)
Receive ring: input to network interface module
Receive tip: input to network interface module
No connection
1
2
3, 6
5
Transmit ring: output from network interface module
Transmit tip: output from network interface module
Optional shield
4
7, 8
The pin designations for the network interface module cable end for DTI/211 T-1 modules
are specified in Table 2-2.
Table 2-2: T1 to DTI/211 Pin Designations
Signal
Pin(s)
Receive ring: input to network interface module
Receive tip: input to network interface module
No connection
1
2
3, 6
4
Transmit ring: output from network interface module
Transmit tip: output from network interface module
Optional shield
5
7, 8
Refer to the Dialogic Network Hardware Reference for additional information on DTI/211 T-
1 modules. Refer to the Dialogic Voice Hardware Reference for additional information on
D/240SC-T1 modules.
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 2–5
Installing the AlphaServer IP Platform Hardware
2.4.1.1.2 Connecting Dialogic DTI/212 E-1 Modules (75-Ohm)
The Dialogic DTI/212 E-1 modules come in 75-ohm and 120-ohm versions. If you have a
DTI/212 120-ohm module, see Section 2.4.1.1.3. Refer to the Dialogic Network Hardware
Reference for additional information on DTI/212 E-1 modules.
On the rear bracket of the DTI/212 75-ohm module are two BNC-type jacks for connecting to
the external E-1 network. The cabling between these jacks and the external E-1 network
should be 75-ohm coaxial. The DTI/212 end of the cable should consist of a BNC-type male
connector. The user is responsible for supplying an appropriate cable for these connections.
The pin designations for the DTI/212 75-ohm cable ends are given in Table 2-3.
Table 2-3: E-1 to DTI/212 75-Ohm Pin Designations
Signal
Jack/Pin
Transmit data: output from DTI/212 (tip)
Transmit data: output from DTI/212 (ring)
Receive data: input to DTI/212 (tip)
Receive data: input to DTI/212 (ring)
J201A center
J201A shield
J201B center
J201B shield
To cable the DTI/212 75-ohm module to the E-1 network, follow these steps:
1. Attach the appropriate end of the E-1 to DTI/212 (receive) cable to jack J201B on the
rear bracket of the DTI/212 module. Carefully push the BNC connector onto the jack and
lock by turning a quarter-turn clockwise.
2. Attach the appropriate end of the DTI/212 to E-1 (transmit) cable to jack J201A on the
rear bracket of the DTI/212 module. Carefully push the BNC connector onto the jack and
lock by turning a quarter-turn clockwise.
2.4.1.1.3 Connecting Dialogic DTI/212 E-1 Modules (120-Ohm)
On the rear bracket of the DTI/212 120-ohm module is an RJ-48C jack for connecting to the
external E-1 network. The cabling between this jack and the CSU should be 120-ohm twisted
pair or equivalent. The DTI/212 120-ohm end of the cable should consist of an RJ-48C plug.
The user is responsible for supplying an appropriate cable for these connections. The pin
designations for the DTI/212 120-ohm cable ends are given in Table 2-4.
Table 2-4: E-1 to DTI/212 120-Ohm Pin Designations
Signal
Pin(s)
Receive ring: input to the DTI/212 120-ohm module
Receive tip: input to the DTI/212 120-ohm module
No connection
1
2
3, 6
5
Transmit ring: output from the DTI/212 120-ohm module
Transmit tip: output from the DTI/212 120-ohm module
Optional shield
4
7, 8
2–6 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
Installing the AlphaServer IP Platform Hardware
To cable the DTI/212 120-ohm module to the E-1 network, follow these steps:
1. Align the RJ-48C connector at the DTI/212 120-ohm module end of the E-1 to DTI/212
120-ohm cable with jack J201 on the rear bracket of the DTI/212 module.
2. Gently push the cable connector into the RJ-48C jack until it snaps into place.
2.4.1.1.4 Connecting Dialogic LSI/120 Loop-Start Module
The customer is responsible for supplying additional cabling to connect the LSI/120 network
interface module to the telephone company lines.
Refer to the Dialogic Network Hardware Reference for additional information on LSI/120
modules.
You can choose from the following connection options:
•
•
Use Compaq's BC22F cable. This cable has a DB-25 connector on one end (to connect to
the LSI/120), and a 50-pin connector on the other end that provides 12 tip and ring pin
pairs that are compatible with a standard RJ-21X USOC jack.
Use Dialogic's SA/120 RJ-11 assembly. This assembly accepts the 50-pin male connector
from the SA/120 RJ-21 cable and terminates with 12 RJ-11 connectors. This cable allows
you to connect individual subscriber lines to the LSI/120.
The pin-out specifications in Table 2-5 and Table 2-6 are for connector P3 on the LSI/120.
This cable uses a 25-pin female DB-25 connector (Amphenol part number 745495-2 or
equivalent) on the LSI/120 end, and a 50-pin jack (Amphenol part number 157-72500-3 or
equivalent) that is compatible with an RJ-21X USOC jack.
Table 2-5: LSI/120 Loop-Start 25-Pin Designations
TIP 8
1
14
15
16
17
18
19
20
21
22
23
24
25
RING 12
TIP 12
RING 11
TIP 11
RING 10
TIP 10
TIP 3
RING 8
TIP 9
2
3
RING 9
TIP 4
4
5
RING 4
TIP 7
6
7
RING 7
TIP 6
8
RING 3
RING 1
TIP 1
9
RING 6
TIP 5
10
11
12
13
RING 2
TIP 2
RING 5
RESERVED
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 2–7
Installing the AlphaServer IP Platform Hardware
Table 2-6: LSI/120 Loop-Start 50-Pin Designations
RING 1
1
26
27
28
29
30
31
32
33
34
35
TIP 1
RING 2
2
TIP 2
RING 3
3
TIP 3
RING 4
4
TIP 4
RING 5
5
TIP 5
RING 6
6
TIP 6
RING 7
7
TIP 7
RING 8
8
TIP 8
RING 9
9
TIP 9
RING 10
RING 11
RING 12
RING NC
RING NC
RING NC
RING NC
RING NC
RING NC
RING NC
RING NC
RING NC
RING NC
RING NC
RING NC
RING NC
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
TIP 10
TIP 11
TIP 12
TIP NC
TIP NC
TIP NC
TIP NC
TIP NC
TIP NC
TIP NC
TIP NC
TIP NC
TIP NC
TIP NC
TIP NC
TIP NC
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
2.4.1.2 IP Power Controller
The AlphaServer IP Platform supports the following power controller models: 120 Vac, 250
Vac, or -48 Vdc. Each simplex and duplex rackmount system has one or two power
controllers located in the bottom of the cabinet. Each controller supports one BA35x-Sx, ISA
bus expansion chassis, and an AlphaServer 1000A system.
Instructions for wiring the -48 Vdc power controllers to the building's power source are
included in Appendix C.
2.4.1.3 User Alarms
If the AlphaServer IP Platform does not use the -48 Vdc power controller, the user can
connect up to three external TTL signal alarms to the 8-pin MJ connector on the alarm
control module. Refer to Appendix B for a pinout of this connector and the Intelligent
Peripheral Fault Manager for Tru64 UNIX Installation and User's Guide for information on
configuring these alarms.
2–8 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
Installing the AlphaServer IP Platform Hardware
2.4.2 Locking Your System
The AlphaServer IP Platform is protected by a key lock in the front and rear door panels.
Duplicate interchangeable sets of keys are provided for both front and rear locks.
The AlphaServer 1000A system also comes with a set of keys for each CPU.
_____________________________ Note____________________________
Store the keys in a safe place. Record the key number for each cabinet door and
each CPU. Store this information in a safe place; you will need the information if
replacement is necessary.
______________________________________________________________
The AlphaServer 1000A Rackmount Owner's Guide contains additional information about the
AlphaServer 1000A locking procedure.
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 2–9
This is some white text.
3
Basic Operation
3.1 Introduction
This chapter describes:
•
•
Turning on the AlphaServer IP Platform
Basic operation of the IP Platform subsystem components
3.2 Turning on the AlphaServer IP Platform
After the AlphaServer IP Platform is properly secured, plugged in, and connected to the
building's network hardware, you are ready to power up the system. Refer to Appendix D and
Appendix E for the IP Platform diagrams to assist you in locating the system components.
3.2.1 Step I: Power Controller Circuit Breakers
Prior to turning on the circuit breakers for the 120 Vac or 250 Vac controllers, ensure that the
neon indicator is on, indicating that an ac voltage is present. The -48 Vdc controller does not
have an indicator for voltage; it should be connected to the -48 Vdc battery/power source
prior to turning on the circuit breakers.
To start powering up the AlphaServer IP Platform, switch the circuit breakers at each power
controller (located in the rear of the cabinet) to the on position. The modular storage shelf
BA35x-Sx automatically powers up.
3.2.2 Step II: ISA Bus Expansion Chassis
To power up the ISA bus expansion chassis, press the On/Off switch on the front of the ISA
bus expansion chassis. The green ON/Off indicator on the front of the ISA bus expansion
chassis will illuminate.
3.2.3 Step III: AlphaServer 1000A System
Turn the AlphaServer 1000A system on by pressing the On/Off switch on the front of the
AlphaServer 1000A unit. The green On/Off indicator on the front of the system will
illuminate.
At this point in the IP Platform power on sequence, the alarm indicator panel should have the
green OK LED lit and the status display will contain either a “b” indicating discharged or
partially charged batteries, or it will be blank.
As described in the following sections, each subsystem within the IP Platform initiates its
own self-test at power-up. The following sections describe what a successful power-up of the
subsystem components looks like.
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 3–1
Basic Operation
3.3 Basic Operation of the IP Platform Subsystem Components
The following sections describe the basic operation of the IP Platform subsystem components.
3.3.1 Alarm Indicator Panel
The alarm indicator panel (see Figure 3-1) contains the following:
•
•
•
•
•
Visual indicators
Audible indicator
Battery backup logic
Keep-alive function
Dry contacts
Visual Indicators
The alarm indicator panel has three alarm LED indicators. These LED indicators are defined
as follows:
•
•
•
Critical (red LED)
Major (red LED)
Minor (amber LED)
The LED for a particular level of severity will be lit as long as at least one event of that level
is active. Multiple LEDs may be simultaneously lit.
The alarm indicator panel has two other indicators used for status information. These are the
following:
•
•
Status display
Alarm indicator panel OK LED (green)
The status display is used to output status as a result of the diagnostic testing and to display
other status information as shown in the following tables.
The OK LED is lit after a successful reset and will remain lit until either an unsuccessful reset
or a loss of battery power occurs.
Refer to the Intelligent Peripheral Fault Manager For Tru64 UNIX Installation and User's
Guide for additional information on the alarm indicator panel and fault management.
______________________________ Note ___________________________
The alarm indicator panel should not be permanently removed without de-
configuring it in the Intelligent peripheral Fault Manager (IPFM) config file.
Refer to the Intelligent Peripheral Fault Manager for Tru64 UNIX Installation
and User's Guide.
______________________________________________________________
3–2 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
Basic Operation
The following table describes the normal conditions of the alarm indicator panel when the
AlphaServer 1000A is powered on and the Intelligent Peripheral Fault Manager (IPFM)
software is running.
Condition
OK LED
Minor Alarm LED Status Display
Audible Alarm
Fully discharged batteries On
Off
Off
Off
“b”
Off
Off
Off
Fully charged batteries
On
On
“Rotating bar”
“b”
Partially charged
batteries
Software Diagnostics
Software Test
On
On
Off
Off
“d”
“t”
Off
Off
If the AlphaServer 1000A system looses power while the IPFM software is running, the
following table describes the possible conditions of the alarm indicator panel.
Condition
OK LED
Minor Alarm LED Status Display
Audible Alarm
Fully discharged batteries Off
Off
On
On
blank
“p”
Off
On
On
Fully charged batteries
On
On
Partially charged
batteries
“b”
Figure 3-1 shows a front and rear view of the alarm indicator panel.
Figure 3-1: Alarm Indicator Panel (Front and Rear View)
Front View
CRITICAL
A
L P H A
S
E R V E R I P
F
A U L T
M
A N A G E R
STATUS
MAJOR
AUDIBLE
DISABLE
MINOR
OK
_
_
_
Battery
_
+
+
Battery
_
+
+
Battery
+
Battery
Battery
_
J8
Battery
Battery
+
+
J3
J5
J4
J2
J6
_
J14
J15
J1
Rear View
ML014057
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 3–3
Basic Operation
Audible Indicator
The audible indicator has three distinct sounds associated with the three levels of alarming.
This indicator is controlled by software through the alarm control module or by a disable
switch on the alarm indicator panel itself. The audible indicator will sound at the level of the
most severe alarmed event that is currently active. No more than one level of audible alarm
can be enabled at any one time. The disable switch turns off the current audible alarm until a
new event occurs that is of equal or greater severity level than the highest level alarm
currently active, or until the event causing the audible alarm is cleared and another alarmed
event is pending.
The three audible alarm levels are defined as follows:
•
Critical is two beeps, the first separated from the second by 0.5 seconds or less. This
double beep pattern is repeated every 1.5 seconds.
•
•
Major is one beep every 1.5 seconds.
Minor is one beep every 5 seconds.
Battery Backup Logic
The battery backup logic is designed to keep the current indicator status functioning for the
life of the batteries (approximately 60 to 120 minutes) in the event of a power failure. It
provides an indication if the batteries are low by displaying a “b” in the status display.
Keep-Alive Function
The alarm indicator panel houses a timer that is used to ensure that the CPU controlling it is
still running. The function is enabled by software, which starts a timer. As long as software
resets the timer before expiration, a “rotating bar” is displayed in the status display, otherwise
a minor alarm is generated. A minor alarm will also be generated if power to the alarm
indicator panel is lost and a “p” will be displayed in the status display.
3.3.1.1 Replacing Batteries in the Alarm Indicator Panel
The alarm indicator panel contains seven 1.2 V, 600 mA, NICD type AA rechargeable
batteries that provide battery backup for providing alarm information when the system loses
power or is turned off. When an alarm indicator panel continuously indicates a low battery
condition in the absence of a power loss, the batteries should be replaced. These batteries
should be replaced only with the same type batteries (PN 12-41230-04) or the equivalent
batteries.
______________________________ Note ___________________________
Compaq recommends that batteries be replaced every two to two and a half years
as preventative maintenance.
______________________________________________________________
Perform the following procedure to replace the batteries in an alarm indicator panel:
1. Power down the AlphaServer 1000A system.
2. At the front of the cabinet, remove the four screws that secure the alarm indicator panel
frame to the front rails.
3. Disconnect the miniature 26-pin cable(s) from the connector(s) on the rear of the alarm
indicator panel(s).
4. On the rear of the alarm indicator panel that indicates a low battery condition, remove
the two screws that secure the miniature 26-pin connector to the rear cover.
3–4 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
Basic Operation
5. Remove the three screws from the top edge and the three screws from the bottom edge of
the alarm indicator panel frame that secure the alarm indicator panel rear cover.
6. Remove the alarm indicator panel rear cover.
7. Remove the seven batteries from the battery holders.
___________________________ WARNING _________________________
Replace the batteries with the same type (PN 12-41230-04) or an equivalent
type recommended by the battery manufacturer. Danger of explosion exists if
batteries are incorrectly replaced. Discard used batteries according to
battery manufacturer instructions. Be certain to follow any applicable
country, state, or local statutes for proper battery disposal.
______________________________________________________________
___________________________VORSICHT _________________________
Ersetzen Sie die Batterien nur durch Batterien des gleichen (PN 12-41230-04)
oder ähnlichen Typs, so wie es vom Hersteller empfohlen wird. Wenn Sie die
Batterien falsch auswechseln, besteht Explosionsgefahr. Folgen Sie bei der
Beseitigung der alten Batterien sowohl den Anweisungen des
Batterieherstellers als auch den jeweiligen länderspezifischen bzw. lokalen
Vorschriften zur richtigen Batteriebeseitigung.
______________________________________________________________
8. Observing proper polarity, install the seven new batteries in the battery holders.
After installing the new batteries, reverse steps 1 through 6.
3.3.1.2 Dry Contacts
The dry contacts terminal connectors (see Figure 3-2) are located on the rear panel of the
alarm display unit. The four contacts on the input terminal block correspond to Critical,
Major, Minor, and Audio Shut-off alarm inputs. The output terminal block contacts
correspond to Critical, Major, Minor, and Audio Shut-off alarm outputs. These terminal
blocks can be used to connect remote alarm indicators. When an alarm condition occurs, the
corresponding relay is closed to connect a voltage on the input terminal to a remote alarming
device on the output terminal. See Table 3-1 for the dry contact relay functional specification.
Additionally, an audible alarm can be remotely disabled by connecting to the Shut-off Alarm
contacts. Refer to Appendix A for the dry contact electrical specifications.
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 3–5
Basic Operation
Figure 3-2: Dry Contact Terminal Connectors
A
B
1
2
3
4
5
6
7
8
9
10
LJ-06572.AI7
A
Input Terminal Block
Ext. Critical Alarm
Ext. Major Alarm
Ext. Minor Alarm
Ext. Shut-off Alarm
Ground
B
Output Terminal Block
Critical Alarm
Major Alarm
➊
➋
➌
➍
➎
➏
➐
➑
➒
➓
Minor Alarm
Shut-off Alarm
Ground
Table 3-1: Dry Contact Relay Functional Specification
Relay State
Power
Condition
No alarm
Critical
Critical
Open
Major
Open
Minor
Open
On
Closed
Open
Open
Open
Minor
Open
Closed
Open
Major
Open
Closed
Open
Off
Battery OK
Battery NOK
Open
Closed
Closed
Closed
Closed
3.3.2 AlphaServer 1000A System
Once the AlphaServer 1000A system power is turned on, the screen on the IP Platform
console displays test codes and initialization messages. When the startup procedure is
complete, the following occurs:
•
The IP Platform console terminal emulation window displays the SRM console prompt
(>>>).
•
The operator control panel on the front of the AlphaServer 1000A system displays the
message "Model 5/500."
Boot the Tru64 UNIX system by typing boot at the console prompt. For duplex systems, type
boot at each processor window. The AlphaServer 1000A system has booted successfully when
the Tru64 UNIX prompt (#) appears.
Refer to the DIGITAL UNIX Installation Guide for installation instructions on booting a
Tru64 UNIX system.
Refer to the AlphaServer 1000A Rackmount Owner's Guide, for additional information on the
operation of the AlphaServer 1000A system.
3–6 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
Basic Operation
3.3.3 Modular Storage Shelf BA35x-Sx Subsystem
There may be up to eight StorageWorks building blocks (SBBs) on each modular storage
shelf BA35x-Sx subsystem. The StorageWorks Building Block (SBB) slots are numbered 0
through 7 from right to left with the power supply SBB in slot 7. On the IP simplex system,
the storage SBBs are in slots 0-6. On the duplex system, the available storage SBBs are in
slots 0-5.
_____________________________ Note____________________________
The SCSI address for the SSB device is defined automatically by the SSB slot
location.
______________________________________________________________
After power is supplied to the IP Platform, observe the status LEDs for the following
successful indications:
•
•
On a power supply SBB, both green status LEDs should be on.
On a storage SBB, the green device activity LED is either on, flashing, or off. The amber
device fault LED is off.
Additional information on the following modular storage shelf BA35x-Sx components can be
found in the BA350 Modular Storage Shelf Subsystem User’s Guide.
•
•
•
•
•
•
•
•
Component functions
Shelf status
Power unit status
Storage device status
StorageWorks building block SSB replacement procedures
Shelf replacement procedures
Power supplies
SCSI buses
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 3–7
Basic Operation
3.3.4 ISA Bus Expansion Chassis
The AlphaServer IP Platform supports a variety of voice/telephony options through the
addition of an ISA bus expansion chassis. The ISA bus expansion chassis is configured with a
20-slot ISA backplane. The EISA to ISA bridge uses one slot and the remaining 19 slots are
available for telephony options. The ISA bus expansion chassis has the following
characteristics:
•
•
•
Conforms to ISA bus specifications
Contains an ON/Off power switch for removing power for servicing
Contains an alarm sensor module for monitoring
Chassis temperature
Chassis voltage
–
–
–
Cooling fan rotation
•
Connector for communication with the alarm control module installed in the AlphaServer
1000A system
•
•
Slide mounted to allow front access to all modules
430 W power supply to support maximum output voltages (to voice boards) and
capacities as shown in the following table.
Voltage
Amps*
70
5
-5
12
-12
1.0
5.0
1.0
* Provided that the maximum
output power does not exceed the
power supply rating.
•
Contains a load module to provide minimum power supply pre-load (4.2 A @ +5 V).
This module may be removed from the ISA bus expansion chassis when the minimum
power supply pre-load can be attained with the installed telephony options.
Each simplex system contains one ISA bus expansion chassis. Each duplex system contains
two ISA bus expansion chassis. A connector on the alarm control module is dedicated to
bringing in physical alarm signals from the ISA bus expansion chassis. Any of the alarm
events listed above cause the alarm subsystem to generate an interrupt to the system software
in order to update the alarm database and also send alarm signals to the alarm indicator panel
for display.
3–8 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
4
Reconfiguring the AlphaServer IP Platform
4.1 Introduction
In order to upgrade the AlphaServer IP Platform or replace defective parts, you need to
remove and install components within the IP Platform. These components are within the
individual AlphaServer 1000A system, ISA bus expansion chassis, and modular storage shelf
BA35x-Sx subsystems. After you change any IP Platform component, you may want to verify
or modify the system configuration.
This chapter lists the components of the IP Platform subsystem that may need to be removed
or installed, and the procedure for viewing and modifying the subsystem configurations using
the IP Platform console terminal SRM commands.
Before you attempt to install third-party devices inside your system unit, check with the third-
party vendor to ensure that your system hardware and operating system software support the
device.
____________________________ Caution __________________________
Static electricity can damage electronic components. Use the antistatic wriststrap
located in the inside rear cabinet door pocket. Additionally, use an antistatic mat
when you handle internal components.
______________________________________________________________
____________________________Achtung __________________________
Elektrostatische Entladungen könnten elektronische Komponenten beschädigen.
Tragen Sie deshalb das Antistatikarmband, das sich in der Tasche an der
Innenseite der hinteren Gehäuseklappe befindet. Außerdem sollten Sie bei der
Berührung von internen Komponenten eine Antistatikmatte benutzen.
______________________________________________________________
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 4–1
Reconfiguring the AlphaServer IP Platform
4.2 AlphaServer 1000A System Configurations
The components of the AlphaServer 1000A system that may need to be replaced or upgraded
include:
•
•
•
Storage devices (DAT tape drive, hard disk drive, floppy drive, CD-ROM drive)
Memory modules
CPU motherboard
EISA modules
–
–
–
–
DExxx Ethernet controller *
Access I/O transmitter module (AT bus expansion kit) *
PCI modules
* KZPSA-BB SCSI controller (qty=2) (optional)
* Alarm control module
•
Power supply
The KZPSA-BB PCI-to-SCSI adapter comes with its own utilities diskette that can be used to
modify the adapter parameters. See the StorageWorks KZPSA PCI-to-SCSI Storage Adapter
User's Guide for a complete description of the adapter.
After modifying the above components, and before you boot the Tru64 UNIX operating
system, you can use the SRM console commands from the IP Platform console terminal to
examine the system configurations of these components, and make modifications if
necessary.
The EISA Configuration Utility (ECU) must be run whenever you add, remove, or move an
EISA or ISA card within the AlphaServer 1000A system. The ECU is a menu-based utility
run from the SRM console that provides online help to guide you through the configuration
process.
______________________________ Note ___________________________
Do not move the slot location of the Access I/O transmitter module. Changing the
location of this module may result in configuration problems.
______________________________________________________________
Table 4-1 describes some of the basic SRM console commands used to verify system
configurations on systems running the Tru64 UNIX operating system.
Table 4-1: SRM Console Configuration Commands
Command
Description
show config
show device
show memory
setand show
Displays the buses on the system and the devices found on those buses.
Displays the devices and controllers on the system.
Displays the main memory configuration.
Sets and displays the environment variables.
Refer to the AlphaServer 1000A Rackmount Owner's Guide for complete instructions on
using the ECU and SRM console commands, or type helpat the SRM prompt (>>>).
4–2 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
Reconfiguring the AlphaServer IP Platform
4.3 ISA Bus Expansion Chassis Configuration
The ISA bus expansion chassis provides a flexible capacity for adding voice modules of
varying types based on products from Dialogic. See Section 1.4 for a complete list of
available ISA bus expansion options.
Once the Dialogic voice modules are physically installed, you need to configure them by
running the ECU from the IP Platform console terminal. Use the ECU to register the modules
with the system hardware, and to reserve the addresses and interrupt request levels (IRQs)
that are to be used by the modules. The ECU attempts to identify and resolve resource
conflicts. The ECU may also be used to determine unused I/O ports, shared memory address,
and IRQs.
In addition to the Dialogic voice modules, other components within the ISA bus expansion
chassis include the:
•
•
•
•
Fan
Power supply
Alarm sensor module
Access I/O transceiver (AT bus expansion kit)
For a complete description of installing and configuring the voice-option modules, refer to the
Dialogic documentation shipped with the option.
For a complete description of removing and replacing the fan or power supply, refer to the I-
Bus 4820 User Manual that is shipped with your system.
Refer to Section 4.3.1 and Section 4.3.2 for complete descriptions of removing and replacing
the alarm sensor module and the AT bus expansion kit.
4.3.1 Removing and Replacing the Alarm Sensor Module
The alarm sensor module is mounted in the drive bay area of the ISA bus expansion chassis.
The 2T-IPSEN-AA alarm sensor module kit consists of an alarm sensor module, a cable to
connect the alarm sensor module to the rear bulkhead, and a cable to connect the rear
bulkhead to the alarm control module in the AlphaServer 1000A.
Perform the following procedure to remove the alarm sensor module:
1. Remove power from the ISA bus expansion chassis by pressing the On/Off switch on the
front of the ISA bus expansion chassis.
2. Remove the screws that secure the ISA bus expansion chassis to the front rails and extend
the ISA bus expansion chassis on the slides.
3. Remove the screws that secure the top cover and remove the top cover from the ISA bus
expansion chassis.
4. Disconnect the 6-pin bulkhead cable, the 4-pin power supply cable, and the 2-pin
temperature sensor cable from the alarm sensor module.
5. Remove the four screws that secure the alarm sensor module to the standoffs and remove
the alarm sensor module.
To replace the alarm sensor module, reverse steps 1 through 5 of the removal procedure.
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 4–3
Reconfiguring the AlphaServer IP Platform
4.3.2 Removing and Replacing the AT Bus Expansion Kit
The 2T-VC220-IP AT bus expansion kit consists of the transmit module installed in the
AlphaServer 1000A, the receive module installed in the ISA bus expansion chassis, and a 2-
meter cable that connects the two modules.
Perform the following procedure to remove the receive module from the ISA bus expansion
chassis:
1. Remove power from the ISA bus expansion chassis by pressing the On/Off switch on the
front of the ISA bus expansion chassis.
2. Remove the screws that secure the ISA bus expansion chassis to the front rails and extend
the ISA bus expansion chassis on the slides.
3. Remove the screws that secure the top cover and remove the top cover from the ISA bus
expansion chassis.
4. Disconnect the cable from the receive module.
5. Remove the hold-down bar from across the top of the modules in the ISA bus expansion
chassis.
6. Remove the screw that secures the receive module to the rear bulkhead of the ISA bus
expansion chassis.
7. Remove the receive module from the ISA bus expansion chassis.
To replace the receive module in the ISA bus expansion chassis, reverse steps 1 through 7 of
the removal procedure. Ensure that the jumpers on the new receive module are set to match
the jumpers on the receive module being replaced.
4.4 Modular Storage Shelf BA35x-Sx Subsystem Configuration
The modular storage shelf BA35x-Sx contains the following components that may need to be
removed and replaced:
•
•
•
•
•
•
StorageWorks building blocks (SBBs)
DWZZB-VW SCSI bus converter
H885-AA tri-link connector block
H879-AA SCSI terminator
Disk drives
Power supply
____________________________Important_________________________
Once a device has been initialized on a SCSI bus with a specific device address,
moving the device to another bus or changing the device address can cause
problems.
______________________________________________________________
Refer to the BA350 Modular Storage Shelf Subsystem User’s Guide for specific instructions
on adding and removing StorageWorks components, and setting the correct device addresses.
4–4 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
Reconfiguring the AlphaServer IP Platform
4.5 Alarm Indicator Panel Configuration
The alarm indicator panel provides programmable visual and audible alarm indicators for the
AlphaServer IP Platform. The alarm indicator panel consists of a metal frame, graphics
panel(s), and alarm indicator module(s). A cable connects the alarm indicator module to the
alarm control module that is installed on the AlphaServer 1000A PCI bus.
4.5.1 Removing and Replacing the Alarm Indicator Module
The alarm indicator module is mounted inside the alarm indicator panel.
Perform the following procedure to replace an alarm indicator module:
1. Power down the AlphaServer 1000A system.
2. At the front of the cabinet, remove the four screws that secure the alarm indicator panel
frame to the front rails.
3. Disconnect the miniature 26-pin cable(s) from the connector(s) on the rear of the alarm
indicator panel(s).
4. If attached, disconnect any cables connected to the dry contact terminal blocks.
5. On the rear of the alarm indicator panel that contains the alarm indicator module to be
replaced, remove the two screws that secure the miniature 26-pin connector to the rear
cover.
6. Remove the three screws from the top edge and the three screws from the bottom edge of
the alarm indicator panel frame that secure the alarm indicator panel rear cover.
7. Remove the alarm indicator panel rear cover.
8. Remove the four screws that secure the alarm indicator module to the alarm indicator
panel frame.
To replace the alarm indicator module, reverse steps 1 through 8 of the removal procedure.
_____________________________ Note____________________________
The alarm indicator panel should not be permanently removed without de-
configuring it in the Intelligent Peripheral Fault Manager (IPFM) config file.
Refer to the Intelligent Peripheral Fault Manager for Tru64 UNIX Installation
and User's Guide.
______________________________________________________________
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 4–5
is some white text.
5
System Troubleshooting
5.1 Introduction
This chapter describes procedures for resolving problems with the components of the
AlphaServer Intelligent Peripheral (IP) Platform. If the subsystem troubleshooting is
discussed in another manual, a reference is provided to that documentation.
Before servicing the system, be aware of any service agreement that exists for your system.
The agreement helps determine the level of maintenance for self-maintenance customers.
To correct a problem, locate the troubleshooting section for that component and refer to the
appropriate documentation. If you cannot correct the problem, report it to your service
representative.
___________________________ WARNING _________________________
Only a qualified service person should install the system. A qualified service
person is an individual who has the technical training and experience to be
aware of the:
•
•
Hazards to which they are exposed in performing a task
Measures to minimize the danger to themselves or other persons
A qualified service person need not be a Compaq service representative.
______________________________________________________________
___________________________VORSICHT _________________________
Das System darf nur von qualifizierten Fachleuten installiert werden.
Qualifizierte Fachleute sind Personen, die entsprechend technisch geschult
sind und über die nötige Erfahrung verfügen, um:
•
die Gefahren zu erkennen, denen sie bei der Ausführung der Arbeit
ausgesetzt sein könnten
•
die notwendigen Maßnahmen zur Minimierung der Gefahr für sie selbst
und für andere Personen zu ergreifen.
Qualifizierte Fachleute sind nicht notwendigerweise Fachleute des Compaq-
Kundendienstes.
______________________________________________________________
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 5–1
System Troubleshooting
5.2 AlphaServer 1000A Subsystem
The AlphaServer 1000A Rackmount Owner's Guide provides the instructions on completing
the following tasks or resolving these particular problems:
•
•
Confirming that EISA modules or memory modules are properly configured
Running a diagnostic test of the entire system, showing its status, or terminating the
testing
•
•
Checking the startup display when you turn on the system
What to do if:
−
−
−
−
−
−
−
The power supply has shut down
Startup tests do not complete
The system cannot boot the operating system
The operating system reports errors, is hung, or crashes
The system cannot access a mass storage device
Storage devices are missing from the show device display
The system indicates network problems, an EISA module is not configured,
or a PCI module is unseen by the system
−
−
−
−
−
The monitor or the terminal is not working
The keyboard and mouse are not working
The system repeatedly shuts down after 10 seconds
The system does not see or cannot access RAID drives
The Flash ROM is corrupted and the system cannot access console mode
5.3 Alarm Indicator Panel
The alarm indicator panel (see Figure 3-1) uses visual and audio alarm indicators to display
the status of the IP Platform, including the ISA bus expansion chassis and the -48 Vdc power
inverter or user alarm inputs. The alarm indicator panel displays alarms as long as it can
communicate with the alarm control module in the AlphaServer 1000A, or until its backup
batteries become fully discharged.
Refer to Section 3.3.1 for a description of the alarm indicator panel alarms and status
displays. Refer to Section 3.3.1.1 for the procedure for replacing the batteries in the alarm
indicator panel.
5–2 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
System Troubleshooting
5.4 ISA Bus Expansion Chassis
The ISA bus expansion chassis contains alarm sensors that detect fault conditions and send
the information to the alarm control module in the AlphaServer 1000A system chassis.
For a complete description of alarm sensor interaction with the IP Fault Manager software,
see the Intelligent Peripheral Fault Manager for Tru64 UNIX Installation and User's Guide.
The status of the Dialogic voice modules is handled at the application level and not by the IP
Fault Manager software.
5.5 Modular Storage Shelf BA35x-Sx Subsystem
The modular storage shelf BA35x-Sx uses the LEDs of its StorageWorks building blocks
(SBBs) to indicate problems within the power unit, storage devices, and StorageWorks shelf.
Depending upon the problem, these displays can be flashing, on, or off. The BA350 Modular
Storage Shelf Subsystem User’s Guide provides instructions on how to interpret these
displays.
5.6 AlphaServer IP Power Controllers
If the power controllers do not function properly, perform the following steps:
1. Prior to turning on the circuit breakers for the 120 Vac or 250 Vac controllers, ensure
that the neon indicator is on, indicating that an ac voltage is present. The -48 Vdc
controller does not have an indicator for voltage. It should be connected to the -48 Vdc
battery/power source prior to turning on the circuit breakers.
2. Check that the circuit breakers are on for each of the power controllers installed.
3. Refer to the DIGITAL 2T-48VDC-xx -48Vdc-to-120Vac Power Inverter Owner’s Guide
for more troubleshooting information on the -48 Vdc controller.
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide 5–3
is some white text.
A
AlphaServer IP Platform Specifications
A.1 Physical Dimensions
Table A-1 contains the physical dimensions for the AlphaServer Intelligent Peripheral (IP)
Platform.
Table A-1: Physical Dimensions
Dimension
Depth
Specification
96.52 cm (38.0 in.) including doors
55.88 cm (22.0 in.)
Width
Height
220.01 cm (86.62 in.) including cable trough
204.77 cm (80.62 in.) without cable trough
385.56 kg (850 lbs) for fully loaded duplex system
76.2 cm (30.0 in.) minimum clearance
60.96 cm (24.0 in.) minimum clearance
Height
Weight
Front aisle
Rear aisle
A.2 Electrical Specifications
Table A-2 contains the electrical specifications for each IP Platform power controller.
Table A-2: Electrical Specifications for Each Power Controller
Specification
Range
Input voltage
120 Vac or
250 Vac or
-48 Vdc
Frequency (ac only)
50-60 Hz
Input current maximum
8.0 A at 120 Vac or
4.0 A at 250 Vac or
50 A at -48 Vdc
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide A–1
AlphaServer IP Platform Specifications
A.3 System Environmental Specifications
Table A-3 contains the environmental specifications for the AlphaServer IP Platform.
Table A-3: Environmental Specifications
Operating/Storage Conditions
Temperature range
10°C to 40°C (50°F to 104°F)
760 mm (29.92 in. Hg)
20% to 80% (noncondensing)
2°C (36°F)
Barometric pressure
Relative humidity
Minimum dew point
Maximum altitude
2,438 m (8,000 ft)1
Maximum wet bulb temperature
28°C (82°F)
Nonoperating Conditions
Temperature range
Relative humidity
Maximum altitude
-40°C to 66°C (-40°F to 151°F)
20% to 85% (noncondensing)
4,877 m (16,000 ft)1
1 The maximum allowable operating temperature above 2,438 m (8,000 ft) is reduced
1.8°C/1,000 m (1.0°F/1,000 ft).
A–2 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
AlphaServer IP Platform Specifications
A.4 Dry Contact Specifications
Table A-4 contains the rating, input, and output specifications for the dry contact terminals.
Table A-4: Dry Contact Specifications
Material and Ratings
Contact material
Gold-clad silver
Rating (resistive)
Maximum switching power
Maximum switching voltage
Maximum switching current
Maximum carrying current
60 W, 125 VA
220 Vdc, 250 Vac
2 A DC, 2 A AC
3 A DC, 3 A AC
Input Specifications
Type
Relay coil
Rated input voltage
Maximum input
Pick-up voltage
Drop-out voltage
Coil resistance
5 Vdc nominal
10 Vdc at 50 C
3.5 Vdc maximum
0.5 Vdc minimum
125 ohms, +/- 10%
Output Specifications
Contact rating (switching)
Voltage
220 Vdc, 250 Vac (maximum)
2 A DC, 2 A AC (maximum)
0.6 A, 125 Vac
Current
UL/CSA
0.6 A, 110 Vdc
2.0 A, 30 Vdc
Coil rating
200 mW typically
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide A–3
AlphaServer IP Platform Specifications
A.5 Central Office Compatibility
The AlphaServer IP Platform is intended for deployment in telecommunications central
office (CO) environments, and is compatible with some of Bellcore's Network Equipment-
Building Systems (NEBS) specifications TR-NWT-000063.
Some of the central office compatible (conforming) hardware requirements supported by the
AlphaServer IP Platform are:
•
•
Simplex or duplex system housed within a single electronic equipment cabinet.
Cabinet of welded steel construction has locking front and rear doors, bolt-down
provisions at the cabinet base and top (for use only when a -48 Vdc power inverter is
installed in the cabinet), four-wheel rugged castor base, four-point leveling, and cable
egress from top or bottom of the cabinet.
•
•
•
Integral cable trough attached to the top-rear half of the cabinet, and for larger systems,
forms a continuous cable trough along the cabinet top-rear.
120 Vac, 250 Vac, and -48 Vdc dual-feed power models are available for the duplex
system.
Weight is 385.56 kg (850 lbs).
______________________________ Note ____________________________
Floor loading is approximately 38.56 kg (85 lbs) per square foot according to
NEBS weight calculation rules. Maximum allowed is 52.16 kg (115 lbs) per
square foot.
_______________________________________________________________
•
•
•
•
•
Operating relative humidity of 20% to 80%.
Acoustic noise is less than 65 dBA.
Designed to meet earthquake Zone 2.
Meets FCC Class A specifications.
Meets UL and other international safety specifications.
NEBS nonconforming features are:
•
•
•
•
•
Cabinet depth is 96.52 cm (38 in.)
Printer and terminal are table-top mounted.
Fire testing not performed.
Convenience outlets not provided.
Earthquake testing for Zones 2, 3, and 4 not performed.
The AlphaServer IP Platform simplex and duplex systems are contained within one single
bay 177.8 cm (70 in.) panel space cabinet (except for console terminal).
A–4 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
B
Alarm Input Wiring
B.1 Alarm Input Wiring Diagram
The following diagram of the Intelligent Peripheral (IP) duplex platform displays the alarm
input wiring connections between the ISA bus expansion chassis, the AlphaServer 1000A
processors, and the alarm indicator panel.
Figure B-1: Alarm Input Wiring Diagram
3
4
2
AlphaServer 1000A
6
5
1
9
8
ISA
7
ML014035
➊
➋
➏
➐
Alarm control module installed in
AlphaServer
Alarm indicator panel cable
the
1000A system
-48 Vdc power inverter
Alarm sensor module in the ISA bus
expansion chassis
➌
➍
➎
➑
➒
D-sub 25-pin connector
Inverter alarm cable
Alarm indicator panel
D-sub 9-pin connector
ISA bus expansion chassis alarm cable
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide B–1
Alarm Input Wiring
B.2 Wiring User Alarm Inputs
This section provides information for wiring user TTL signal alarm inputs to the 8-pin MJ
connector on the alarm control module installed in the AlphaServer 1000A system.
Figure B-2 shows the 8-pin MJ connector on the alarm control module that is used for
connecting user alarm inputs.
Figure B-2: Alarm Control Module 8-Pin MJ Connector
1
8
ML014036
Table B–1 provides a pinout listing of the pins on the alarm control module 8-pin MJ
connector. This table should be used to determine the correct wiring required for user alarm
inputs.
Table B–1: Alarm Control Module 8-Pin MJ Connector Pinout
Pin No.
Signal
1
2
3
4
5
6
7
8
Inverter Fail or user input 1 Return
Inverter Fail or user input 1
Inverter Minor or user input 2 Return
Inverter Minor or user input 2
Inverter Major or user input 3 Return
Inverter Major or user input 3
Not used
Not used
B–2 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
C
Field Wiring the -48 Vdc Power Inverter
C.1 Field Wiring the -48 Vdc Power Controllers
The following sections describe how to field wire the -48 Vdc power controllers.
___________________________ WARNING _________________________
The person(s) installing the system should be aware of the 1993 NEC
(National Electrical Code) requirements for data processing equipment
installation, Article 645, 645-2. Failure to follow these requirements could
result in personal injury and damage to the equipment.
Only a qualified service person should install the system. A qualified service
person is an individual who has the technical training and experience to be
aware of the:
•
•
Hazards to which they are exposed in performing a task
Measures to minimize the danger to themselves or other persons
A qualified service person need not be a Compaq service representative.
______________________________________________________________
___________________________VORSICHT _________________________
Die Personen, die das System installieren, sollten die Voraussetzungen des
1993 NEC (National Electrical Code) zur Installation von
Datenverarbeitungsgeräten, Artikel 645, 645-2, kennen. Mißachtung dieser
Voraussetzungen könnte zu Personen- und Geräteschaden führen.
Das System darf nur von qualifizierten Fachleuten installiert werden.
Qualifizierte Fachleute sind Personen, die entsprechend technisch geschult
sind und über die nötige Erfahrung verfügen, um:
•
die Gefahren zu erkennen, denen sie bei der Ausführung der Arbeit
ausgesetzt sein könnten
•
die notwendigen Maßnahmen zur Minimierung der Gefahr für sie selbst
und für andere Personen zu ergreifen.
Qualifizierte Fachleute sind nicht notwendigerweise Fachleute des Compaq-
Kundendienstes.
______________________________________________________________
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide C–1
Field Wiring the -48 Vdc Power Inverter
C.1.1 Installing Suitable Field Wiring
The following subsections describe how to install suitable field wiring.
C.1.1.1 Field Wiring Recommendations
Table C–1 lists the field wiring recommendations for each side of the -48 Vdc power
controller. The -48 Vdc power controller has dual power feeds.
Table C–1: Field Wiring Recommendations for Each Power Feed
Input Power Requirement
Input voltage
-48 Vdc Power Controller
-48 Vdc
Input current
50 A max
Inrush peak
6 A max soft start limited
Recommended wire: Wire should be U/L recognized and CSA certified for 105°C (221°F),
with insulation rated for 600 Vac. Each of the 3-wire conductors should be a minimum of 6
AWG stranded.
____________________________WARNING_________________________
High energy hazard. Proper precautions required.
______________________________________________________________
___________________________ VORSICHT ________________________
Hochspannungsgefahr. Geeignete Vorsichtsmaßnahmen sind notwendig.
______________________________________________________________
C.1.1.2 Installing the Wiring
1. Strip the wire insulation to approximately 1.27 cm (.50 in.).
2. Insert the wire into the terminal block as follows:
a. Observe the wire color/polarity
Black: -48 Vdc
–
–
–
White: +48 Vdc
Green/yellow: Ground
b. Torque the #10-32 compression screws to 40 to 45 inch-pounds.
______________________________ Note ___________________________
Refer to the DIGITAL 2T-48VDC-xx -48Vdc-to-120Vac Power Inverter Owner’s
Guide for information on powering up and testing the -48 Vdc inverter.
______________________________________________________________
C–2 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
D
AlphaServer IP Platform Duplex System
Diagrams
D.1 Introduction
This appendix contains diagrams of the AlphaServer Intelligent Peripheral (IP) Platform
duplex, ac and dc, systems.
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide D–1
AlphaServer IP Platform Duplex System Diagrams
D.2 AlphaServer IP Platform Duplex AC System
This section contains the front, side, and rear views of the duplex ac system.
Figure D–1: IP Platform Duplex AC System Front and Side View
1
2
3
4
5
Front View
Side View
ML014018
➊
➋
➌
Alarm indicator panels
➍ AlphaServer 1000A
BA35x-Sx modular storage shelf (optional)
ISA bus expansion chassis
➎ H7600 power controller
D–2 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
AlphaServer IP Platform Duplex System Diagrams
Figure D–2: IP Platform Duplex AC System Rear View
1
2
3
4
5
Back View
ML014028
➊
➋
➌
Alarm indicator panels
➍ AlphaServer 1000A
BA35x-Sx modular storage shelf (optional)
ISA bus expansion chassis
➎ H7600 power controller
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide D–3
AlphaServer IP Platform Duplex System Diagrams
D.3 AlphaServer IP Platform Duplex DC System
This section contains the front, side, and rear views of the duplex dc system.
Figure D–3: IP Platform Duplex DC System Front and Side View
1
2
3
4
MX ALARM CARD
AC POWER
5
Front View
Side View
ML014017
➊
➋
➌
Alarm indicator panels
➍ AlphaServer 1000A
BA35x-Sx modular storage shelf (optional)
ISA bus expansion chassis
➎ -48 Vdc power controller
D–4 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
AlphaServer IP Platform Duplex System Diagrams
Figure D–4: IP Platform Duplex DC System Rear View
1
2
3
4
_
_
5
_
_
+
+
+
+
Back View
ML014027
➊
➋
➌
Alarm indicator panels
➍ AlphaServer 1000A
BA35x-Sx modular storage shelf (optional)
ISA bus expansion chassis
➎ -48 Vdc power controller
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide D–5
is some white text.
E
AlphaServer IP Platform Simplex System
Diagrams
E.1 Introduction
This appendix contains diagrams of the AlphaServer Intelligent Peripheral (IP) Platform
simplex, ac and dc, systems.
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide E-1
AlphaServer IP Platform Simplex System Diagrams
E.2 AlphaServer IP Platform Simplex AC System
This section contains the front, side, and rear views of the simplex ac system.
Figure E–1: IP Platform Simplex AC System Front and Side View
1
2
3
4
5
Front View
Side View
ML014022
➊
➋
➌
Alarm indicator panel
➍ AlphaServer 1000A
BA35x-Sx modular storage shelf (optional)
ISA bus expansion chassis
➎ H7600 power controller
E-2 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
AlphaServer IP Platform Simplex System Diagrams
Figure E–2: IP Platform Simplex AC System Rear View
1
2
3
4
5
Back View
ML014032
➊
➋
➌
Alarm indicator panel
➍ AlphaServer 1000A
BA35x-Sx modular storage shelf (optional)
ISA bus expansion chassis
➎ H7600 power controller
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide E-3
AlphaServer IP Platform Simplex System Diagrams
E.3 AlphaServer IP Platform Simplex DC System
This section contains the front, side, and rear views of the simplex dc system.
Figure E–3: IP Platform Simplex DC System Front and Side View
1
2
3
4
MX ALARM CARD
AC POWER
5
Front View
Side View
ML014021
➊
➋
➌
Alarm indicator panel
➍ AlphaServer 1000A
BA35x-Sx modular storage shelf (optional)
ISA bus expansion chassis
➎ -48 Vdc power controller
E-4 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
AlphaServer IP Platform Simplex System Diagrams
Figure E–4: IP Platform Simplex DC System Rear View
1
2
3
4
5
_
_
_
_
+
+
+
+
Back View
ML014031
➊
➋
➌
Alarm indicator panel
➍ AlphaServer 1000A
BA35x-Sx modular storage shelf (optional)
ISA bus expansion chassis
➎ -48 Vdc power controller
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide E-5
is some white text.
Glossary
10Base-T Ethernet network
The IEEE standard 802.3-compliant Ethernet products used for local distribution of data.
These networking products characteristically use twisted-pair cable.
agent
A background task running on the object being managed. The agent responds to requests for
information by the network management station (NMS). The agent is responsible for
performing get and set operations, for generating the appropriate traps, and for controlling
access.
AlphaServer system
Compaq’s new generation of server systems based on the Alpha 64-bit computing
architecture.
ARC
Advanced RISC Computing (ARC) is the user interface to the console firmware for operating
systems that expect firmware compliance with the Windows NT Portable Boot Loader
Specification.
availability
The amount of scheduled time that a computing system provides application service during
the year. Availability is typically measured as a percentage of up time per year.
backbone
A core network (usually high speed) to which multiple local area networks (LANs) are
connected using bridges or routers and over which internetwork traffic can pass.
backplane
The main module (board or panel) that connects all of the modules in a computer system.
boot
Short for bootstrap. To load an operating system into memory.
boot device
The device from which the system bootstrap software is acquired.
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide Glossary-1
Glossary
bus
A collection of many transmission lines or wires. The bus interconnects computer system
components, providing a communications path for addresses, data, and control information or
external terminals and systems in a communications network.
cache
A small, high-speed memory placed between slower main memory and the processor. A
cache increases effective memory transfer rates and processor speed. It contains copies of
data recently used by the processor and fetches several bytes of data from memory in
anticipation that the processor will access the next sequential series of bytes.
CD-ROM
Compact disc read-only memory. The optical removable media used in a compact disc
reader.
central processing unit (CPU)
The unit of the computer that is responsible for interpreting and executing instructions.
command line interface
One of two interfaces in the AlphaServer operator interface. The command line interface
supports OpenVMS and Tru64 UNIX operating systems. It allows you to configure and boot
the operating system.
console mode
The state in which the system and the console terminal operate under the control of the
console program.
console subsystem
The subsystem that provides the user interface for a computer system when the operating
system is not running.
console terminal
The terminal connected to the console subsystem. It is used to start the system and to direct
activities between the user and the computer system.
CSU
Channel service unit. A device that terminates a digital channel on a customer's premises. It
contains certain line conditioning and equalization functions, and responds to loopback
commands sent from the central office.
daughterboard
A PC module that attaches to the component side of the host module.
diagnostic program
A program that finds and corrects problems with a computer system.
Glossary-2 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
Glossary
dry contacts
An electromagnetic device for remote or automatic control that is activated by variation in
conditions of an electric circuit and that in turn operates other devices (such as switches) in
the same or a different circuit.
DSX-1
Digital Signal Cross-connect Level 1. Any equipment that supports a set of parameters for
cross-connecting DS-1 (either T-1 or E-1) lines.
E-1
Another name given to the CEPT (Conference of European Postal and Telecommunications
Administrations) digital telephony format. E-1 is a digital transmission channel that carries
data at the rate of 2.048 Mb/s (DS-1 level).
ECC
Error correction code. The code and algorithms used by logic to facilitate error detection and
correction.
EISA bus
Extended Industry Standard Architecture bus. A 32-bit industry-standard I/O bus used
primarily in high-end PCs and servers.
EISA Configuration Utility (ECU)
A feature of the EISA bus that helps you select a conflict- free system configuration and
perform other system services. The ECU must be run whenever you change, add, or remove
an EISA or ISA controller.
environment variables
The global data structures that can be accessed from console mode. The setting of these data
structures determines how a system powers up, boots the operating system, and operates.
Ethernet
The IEEE 802.3 standard local area network.
firmware
The software code stored in hardware.
initialization
The sequence of steps that prepare the computer system to start. Initialization occurs after a
system has been powered up.
Interrupt request lines (IRQs)
The bus signals that connect an EISA or ISA module (for example, a disk controller) to the
system so that the module can get the system's attention by means of an interrupt.
ISA
Industry Standard Architecture. An 8-bit or 16-bit industry-standard I/O bus, widely used in
personal computer products. The EISA bus is a superset of the ISA bus.
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide Glossary-3
Glossary
LAN
Local area network. A high-speed network that supports computers connected over limited
distances.
light-emitting diode (LED)
An indicator of status on an IP subsystem.
MAC (media access control) address
A unique 48-bit binary number (usually represented as a 12-digit hexadecimal number)
encoded in a device's circuitry to identify it on a local area network.
Maintenance Operations Protocol (MOP) session
A logical connection using the Maintenance Operations Protocol (MOP).
mass storage device
An input/output device on which data is stored. Typical mass storage devices include disks,
magnetic tapes, and CD-ROM.
module
A hardware or software component that is a self-contained system interacting with a larger
system. Hardware modules are often made to plug into a main system.
network
A collection of computers, terminals, and other devices together with the hardware and
software that enables them to exchange data and share resources over either short or long
distances.
network management station (NMS)
A PC or workstation equipped with an Ethernet, FDDI, or Token Ring network module and
HUBwatch software that enables it to communicate with and manage network modules.
network modules
Modular devices that provide network connectivity or services that can be installed in a
DEChub backplane or used as standalone devices. Network modules include repeaters,
concentrators, bridges, brouters, access servers, switches, and SNMP agents.
PCI
Peripheral component interconnect. An industry-standard expansion I/O bus that is the
preferred bus for high-performance I/O options. PCI is available in a 32-bit version and a 64-
bit version.
PCI-to-EISA bridge
The capability to transfer commonly available EISA and ISA options to the PCI bus.
protocol
A formal set of rules governing the format, timing, sequencing, and error control of
exchanged messages on a data network.
Glossary-4 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
Glossary
RAID
Redundant arrays of independent disks. A technique that organizes disk data to improve
performance and reliability. RAID has three attributes: it is a set of physical disks viewed by
the user as a single logical device; the user's data is distributed across the physical set of
drives in a defined manner; and redundant disk capacity is added so that the user's data can be
recovered even if a drive fails.
redundant
Pertaining to duplicate or extra computing components that protect a computing system from
failure.
reliability
The probability that a device or system will not fail to perform its intended functions during a specified
time.
repeater
A level 1 hardware device that restores signal amplitude, waveform, and timing of signals
before transmission to another network segment.
SBB
StorageWorks building block. The basic building block of the StorageWorks product line.
Any device conforming to shelf mechanical and electrical standards installed in either a 3½-
inch or 5¼-inch carrier is considered to be an SBB, whether it be a storage device, a power
supply, or other device.
SCSI
Small Computer Systems Interface. An ANSI-standard interface for connecting disks and
other peripheral devices to computer systems. Some devices are supported under the SCSI-1
specification; others are supported under the SCSI-2 specification.
server
A network node or specialized device that provides and manages access to shared network
resources, such as hard disks, printers, and software.
SIMM
Single in-line memory module. A plug-in module that has RAM chips on one side, and an
edge connector that matches a socket on the system module.
Simple Network Management Protocol (SNMP)
A high-level, standards-based protocol for network management, usually used in TCP/IP
(Transmission Control Protocol/Internet Protocol) networks.
SNMP agent
An entity in a hardware device that executes SNMP requests.
SRM
The user interface to console firmware for operating systems that expect firmware
compliance with the Alpha System Reference Manual (SRM).
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide Glossary-5
Glossary
StorageWorks
Compaq's modular storage subsystem (MSS), which is the core technology of the Alpha
SCSI-2 mass storage solution. StorageWorks consists of a family of low-cost mass storage
products that can be configured to meet current and future storage needs.
system disk
The device on which the operating system resides.
T-1
The digital telephony format used in North America. T-1 is a digital transmission link
handling 24 voice conversations on two pairs of twisted wires.
Telnet
The TCP/IP standard protocol for remote terminal connections. Using Telnet, a user at one
site can connect to a timesharing system at another site as if the user's terminal is connected
directly to the remote machine.
terminal server
A module that allows a terminal to connect to a network node.
ThinWire
Ethernet cabling and technology used for local distribution of data communications.
ThinWire cabling is thinner than thick wire cabling.
Transmission Control Protocol (TCP)
The transport protocol offering a connection-oriented transport service in the Internet suite of
protocols.
workgroup
A configuration that consists of a relatively small number of devices attached to a LAN that
is isolated from the extended LAN backbone by a bridge or router.
Glossary-6 AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide
Index
75-ohm network connections,
2–6
75-ohm pin designations, 2–6
EISA Configuration Utility (ECU),
4–2
Electrical specifications, A–1
Environmental specifications, A–2
External hardware options, 1–11
A
Alarm indicator module
replacing, 4–5
Alarm indicator panel
diagram, 3–3
replacing batteries, 3–4
troubleshooting, 5–2
Alarm input wiring diagram, B–1
Alarm sensor module
replacing, 4–3
Alarm subsystem, 1–4
AlphaServer 1000A system
components, 4–2
F
Factory installed
hardware, 2–1
software, 1–3
Fault management, 1–3
Features
optional hardware, 1–7
overview, 1–6
power-up, 3–1
alarm subsystem, 1–4
corporation and industry
standards, 1–5
maintainability, 1–4
reliability, 1–4
reconfiguring, 4–2
required hardware, 1–7
troubleshooting, 5–2
AT bus expansion kit
replacing, 4–4
system security, 1–6
upgrading, 1–5
user interfaces, 1–4
B
H
Hardware
BA35x-Sx. See Modular storage
shelf
factory installed, 2–1
Hardware setup, 2–3
connecting network hardware,
2–4
D
Dialogic modules, 1–9
Dry contact specifications, A–3
Dry contacts, 3–5
installing the platform, 2–4
Duplex system. See IP Platform
ac system diagrams, D–2
dc system diagrams, D–4
duplex system, 1–2
I
Installation
hardware installation, 2–3
preinstallation considerations,
2–2
E
E-1
site preparation, 2–2
Intelligent Peripheral Platform. See
IP Platform
120-ohm network connections,
2–6
120-ohm pin designations, 2–6
Interfaces
telecomminications, 1–5
user, 1–4
AlphaServer Intelligent Peripheral Platform Hardware Owner's Guide Index-1
Index
IP Platform
Power controller subsystem
dc field wiring, C–1
hardware, 1–10
duplex ac system diagrams, D–
2
duplex dc system diagrams, D–
4
overview, 1–10
troubleshooting, 5–3
duplex system, 1–2
electrical specifications, A–1
environmental specifications,
A–2
installing, 2–4
overview, 1–1
physical dimensions, A–1
power controller, 2–8
power-up, 3–1
R
Replacing alarm indicator module,
4–5
Replacing alarm indicator panel
batteries, 3–4
Replacing alarm sensor module, 4–3
Replacing AT bus expansion kit, 4–4
reconfiguration, 4–1
simplex ac system diagrams, E-
2
simplex dc system diagrams, E-
4
S
Simplex system. See IP Platform
ac system diagrams, E-2
dc system diagrams, E-4
simplex system, 1–2
Site preparation, 2–2
Software
simplex system, 1–2
troubleshooting, 5–1
ISA bus expansion chassis
components, 4–3
hardware, 1–9
factory installed, 1–3
SRM console commands, 4–2
Standards
overview, 1–8
electromagnetic, 1–5
safety, 1–5
reconfiguring, 4–3
troubleshooting, 5–3
telecommunications, 1–5
StorageWorks. See Modular storage
shelf
L
Loop-start network
System security, 1–6
25-pin designations, 2–7
50-pin designations, 2–8
hardware connections, 2–7
T
T-1
cable length, 2–2
M
network connections, 2–5
pin designations, 2–5
Telecommunications interfaces, 1–5
Troubleshooting
Modular storage shelf
components, 4–4
hardware, 1–8
operation, 3–7
overview, 1–8
reconfiguring, 4–4
status LEDs, 3–7
troubleshooting, 5–3
alarm indicator panel, 5–2
AlphaServer 1000A, 5–2
IP platform, 5–1
ISA bus expansion chassis, 5–3
modular storage shelf, 5–3
power controller
N
subsystem, 5–3
NEBS compatibility, A–4
U
P
User alarm input wiring, B–2
User interfaces, 1–4
Physical dimensions, A–1
Index-2 DIGITAL AlphaServer Intelligent Peripheral Platform Hardware Owner’s Guide
|