BAP422IUK04EM1 Visual.qxd 3/12/04 3:12 AM Page 1
Air Purifier
BAP422
Holmes Products (Europe) Ltd
1 Francis Grove
London SW19 4DT
England
Fax: +44 (0)20 8947 8272
Email: [email protected]
UK - Filter Sales Order Line - 0870 759 9000
UK - Free phone Customer Service Helpline – 0800 052 3615
Holmes Products France
1015, Rue du Maréchal Juin
Z.I Vaux - Le - Pénil
77000 Melun – France
Phone: +33 1 64 10 45 80
Fax: +33 1 64 10 02 32
FRANCE - SERVICE CONSOMMATEURS
0 825 85 85 82
Belgium
Czech Republic
Denmark
Finland
+32 38 70 86 86
+420 48 513 03 03
+45 45 93 43 73
+358 98 70 870
+30 2 10 61 56 400
+36 72 482 017
+31 793 41 77 71
+47 51 66 99 00
+48 22 847 8968
+7 095 334 82 21
+34 91 64 27 020
+46 31 29 09 80
Greece
Hungary
Netherlands
Norway
Poland
Russia
Spain
Sweden
BAP422IUK04EM1
INSTRUCTION MANUAL
BAP422IUK04EM1 Visual.qxd 3/12/04 3:12 AM Page 7
• If the supply cord or plug is damaged, it must
particles exiting the air purifier and being attracted
to walls, carpets, furniture and other household
objects. These dirty particles may prove very difficult
to remove.
FILTER REPLACEMENT
U.K. and IRELAND
be replaced by the manufacturer or its service
agent or a similarly qualified person in order to
avoid hazard.
• The air purifier contains no user serviceable
parts and should the product suffer damage or
breakdown it must be returned to the manufacturer
or its service agent.
• Should the air purifier stop working, first check
the fuse in the plug (UK only) or fuse/circuit breaker
at the distribution board is operating, before
contacting the manufacturer or service agent.
IMPORTANT: IN ORDER TO RETAIN THE
EFFICIENCY OF YOUR AIR PURIFIER, THE
HEPA FILTER NEEDS TO BE CHANGED EVERY
6 MONTHS.
PLEASE READ AND SAVE THESE
IMPORTANT INSTRUCTIONS.
PRE-OPERATING INSTRUCTIONS
1. After removing the unit from the box, remove
the plastic covering from the unit.
2. Select a firm level place where there are no
obstructions to the air inlet (front grill) or filtered
air outlet.
3. Remove the inlet grill by pulling the grill towards
you.
1. Every few weeks check the condition of the
pre-filter.
With proper care and use, this Bionaire™
air purifier will give you fresh, clean air
for many years.
2. Remove the inlet grill. If the foam pre-filter has
collected a noticeable amount of dust, remove
it from the inlet of the grill and wash it in warm
soapy water. Rinse and dry the pre-filter thoroughly
before replacing it in the inlet of the grill.
3. With the inlet grill removed, remove the HEPA
cartridge and dispose in the dustbin. DO NOT
try to wash and re-use the HEPA filter. Replace
with a new HEPA filter-BAPF30 removing the
protective plastic bag before inserting into the
air purifier.
4. Align the clips on the side of your HEPA filter with
the rails on the inside of the unit. Gently slide
the filter onto the rails.
5. The filter clip should easily slide onto the filter
hang tabs. Do not use force while attaching the
filter clip to the filter. Align the clip on the side of
your HEPA filter with the rails on the inside of
the unit.
NOTE: Before reading these instructions, please
view the corresponding illustrations.
DESCRIPTIONS (SEE FIG 1/4)
A.Inlet Grill
HOW THE AIR PURIFIER WORKS
Dirty, dust laden air is drawn through the back of
the air purifier and through the multi-stage filtration
system.
1. The carbon filter will help clear odours making
the air cleaner and fresher.
2. The HEPA filter entraps 99% of all smaller visible
and non-visible particles down to 2 microns in
size.
4. Remove both HEPA filters by gripping on both
sides and pulling forward.
B.Washable Foam Pre-Filter
C.HEPA/Carbon Filter
D.Filtered Air Outlet
E.Filter Indicator Light
F. Reset Button
G.Ionizer Light
H.Ionizer Control
I. Speed Control
J. Power Light
5. Remove protective plastic bag from each filter
cartridge. The filter clip can only be attached
to the hang tabs on the filter one way (see fig 3).
The filter clip should easily slide onto the filter
hang tabs. Do not use force whilst attaching
the filter clip to the filter. Align the clip on the
HEPA filter with the rails on the inside of the unit.
NOTE: The pleated material and rubber gasket
should be facing towards the unit when applied.
6. Replace the inlet grill by sliding back on to the
unit. Make sure that it snaps securely into position
(the grill only goes on one way).
PRODUCT FEATURES
Filter Life Indicator
Your air purifier has an indicator light that illuminates
when its time to change the filters.
SAFETY PRECAUTION
Carefully read and retain all instructions before
using the air purifier.
• To avoid fire or shock hazard, check that the
voltage on the product corresponds to your
electricity supply and plug directly into an
electrical outlet.
• To avoid fire hazard, never put the cord under
rugs, or near any heat source.
• Carefully discard any plastic wrapping that was
used for the packaging.
• Do not use the air purifier outside.
• Do not place the unit near any heat source or
in direct sunlight.
• Always unplug the air purifier before removing
the grill, changing the filters, cleaning the air
purifier or whenever it is not in use.
• Do not use in or around water or any other liquids.
Do not attempt to wash the unit under running
water.
• Use appliance only for intended household use
as described in this manual.
• Ensure that all air openings are not restricted
or covered in any way.
• Do not place anything on top of the unit.
• Never insert any object into any openings.
• Do not use the air purifier if any part is missing
or damaged in any way.
• Do not attempt to repair or adjust any mechanical
functions of this unit. If the unit becomes damaged
return to the place of purchase or phone the
helpline number on the back of this leaflet.
NOTE: The pleated material and rubber gasket
should be facing towards the unit when applied.
6. Replace the inlet grill by sliding back on to the
unit. Make sure that it snaps securely into position
(the grill only goes on one way)
NOTE: Do not point outlet towards wall.
Ioniser
Your Bionaire™ Air Purifier has an independently
controlled ioniser, which when turned on, releases
negative ions into the outgoing filtered air. Ions
are tiny particles that carry either a positive or
negative charge. These ions exist naturally all
around us in the air, water and ground. Both positive
and negative ions are colourless, odourless and
completely harmless.
OPERATING INSTRUCTIONS
1. Plug into a suitable 220 – 240V electrical outlet.
2. Select the required operating Speed: Hi (
),
NOTE: Do not point outlet towards wall.
Medium ( ), Low ( ) by sliding the switch
to the appropriate setting.
3. To release negative ions into the filtered air
7. After replacing the HEPA filters, RESET the
Filter Life Indicator by inserting a small object
(such as a pin or paper clip) into the hole marked
slide the Ioniser button (
light will illuminate.
) to ON. The amber
RESET (
).
Negative ions help the air purification process by
attaching themselves to very small airborne particles
in the room. These particles take on a negative
charge and may join with positively charged particles,
such as dust, pollen, smoke and pet dander to form
larger particles that are then more readily captured
by the filter system, or they may be attracted to
positively charged surfaces like walls or floors.
4. The ioniser will not work unless the unit is running.
REPLACEMENT FILTERS
5. For optimum air filtration, it is recommended to
operate the air purifier continuously. Its rugged
motor is designed to give many years of service.
6. For continuous use it is recommended to operate
the air purifier at the Medium ( ) setting. For
quieter operation or use in a bedroom, select
BAPF30 HEPA Filter (usage 2 pcs)
The Holmes Group reserves the right to change
or modify any specifications without notice.
the Low (
) setting. When high levels of air
You may also note, after extended use, that dust
may have collected around the grills or front panel.
pollution are present, select the HI ( ) setting
to quickly circulate clean filtered air.
This is from the ionisation effect caused by the
negative ions exiting from the air outlet.This dust
does not come from the air output, but is drawn
out of the uncleaned air going past the air outlet.
This is additional evidence of the air cleaning
effectiveness of negative ions. The dust can be
easily removed with a clean, dampened cloth or
soft brush.
CLEANING AND MAINTENANCE
1. Turn the air purifier off and unplug it before cleaning.
2. The outside of the air purifier can be cleaned
with a soft, clean dampened cloth.
3. The filtered air outlet can be cleaned of dust
with a small, soft brush.
4. If you wish to clean the inside of the air purifier,
please only use a dry, soft cloth to wipe it down.
NOTE: it is important to change the HEPA filter
at recommended intervals. Using the ioniser in
conjunction with dirty filters may result in dirty
3
2
BAP422IUK04EM1 Visual.qxd 3/12/04 3:12 AM Page 9
For U.K. and Ireland only:
TROUBLESHOOTING
Problem Solution
If the plug is not suitable for the socket outlets in
your home, it can be removed and replaced by
a plug of the correct type. Please refer to
"Installation of a plug" below.
Unit will not operate. Check to make sure the unit
is plugged in.
Installation of a plug Applicable to U.K.
and Ireland.
This product is fitted with a 13A plug complying
to BS1363. If this plug is unsuitable or needs to
be replaced, please note the following:
Check to make sure the unit
is on by turning the knob.
Make sure the filters are
properly installed and firmly
close the door.
The wires in the mains lead are coloured as such:
BROWN
BLUE
-
-
LIVE
NEUTRAL
Decreased air flow. If the filters have not been
changed for 6 month or more,
change the HEPA filters.
Please note that the colour of these mains wires
may not correspond with the colour markings that
identify the terminals in your plug. Please proceed
as follows:
Check to ensure nothing is
blocking the air inlet and
filtered air outlet.
The BROWN coloured wire must be connected
to the terminal, which is marked with the letter
"L" or is coloured RED.
The BLUE coloured wire must be connected to
the terminal, which is marked with the letter "N"
or is coloured BLACK.
GUARANTEE
PLEASE KEEP YOUR RECEIPT AS THIS WILL
DO NOT CONNECT either of these wires to the
earth terminal in the plug. The earth terminal plug
is marked with the letter "E", or with the earth
BE REQUIRED FOR ANY CLAIMS UNDER THIS
GUARANTEE.
• This appliance is guaranteed for 2 years.
• In the unlikely event of breakdown from a
manufacturing related fault, please return it to
symbol,
or coloured GREEN, or GREEN and
YELLOW.
the place of purchase, with your till receipt and
a copy of this guarantee.
• The rights and benefits under this guarantee
are additional to your statutory rights which are
not affected by this guarantee.
• The Holmes Group undertakes within the
specifiied period, to repair or replace free of
charge, any part of the appliance found to be
defective from a manufacturing fault provided
that:
• We are promptly informed of the defect.
• The appliance has not been altered in any
way or subjected to misuse or repair by a
person other than a person authorised by
The Holmes Group.
• Faults that occur through normal wear and tear
are not covered by this guarantee.
• No rights are given under this guarantee to a
person acquiring the appliance second hand
or for commercial or communal uses.
NOTE: If the terminals in the plug are not marked
or if you are unsure or in doubt about the
installation of the plug please contact a qualified
electrician.
If a 13A 3-pin plug is fitted, it must be an ASTA
approved plug, conforming to BS1363 standard.
Replacement 3A fuses must be BSI or ASTA
BS1362 approved.
• Any repaired or replaced appliance will be
guaranteed on these terms for the remaining
portion of the guarantee.
THIS PRODUCT IS MANUFACTURED TO
COMPLY WITH THE E.E.C. DIRECTIVES
73/23/EEC, 89/336/EEC and 98/37/EEC.
5
4
|