&RQIHUHQꢀHꢁ6HULHVꢁ3KRQH
8VHU¶Vꢀ*XLGH
CONTENTS
Introduction. . . . . . . . . . . . . . . . . . . . . . . . 1
Overview. . . . . . . . . . . . . . . . . . . . . . . . 1
Input Jacks . . . . . . . . . . . . . . . . . . . . . . 2
Parts Included with
Your Conference Phone . . . . . . . . . . . . 2
Getting Started . . . . . . . . . . . . . . . . . . . . . 3
Installing the Bizfon
Conference Series Phone . . . . . . . . . . . 3
Setting up the Extension to Which the
Conference Phone is Connected . . . . . . 4
Using Your Bizfon
Conference Series Phone . . . . . . . . . . . . . 7
Making an Outgoing Telephone Call . . 7
Answering Incoming Calls . . . . . . . . . . 8
Using Your Conference
Phone Features . . . . . . . . . . . . . . . . . . . 8
Getting Better Performance from Your
Conference Phone. . . . . . . . . . . . . . . . . 9
Bizfon Conference Series Phone User’s Guide
iii
Regulatory and Safety
Information
and Specifications . . . . . . . . . . . . . . . . . . 11
FCC Statement: Part 68 . . . . . . . . . . . 11
FCC Statement: Part 15, Class A . . . . 13
Canadian DOC Statement. . . . . . . . . . 14
Industry Canada Notice . . . . . . . . . . . 14
Important Safety Instructions . . . . . . . 15
Specifications . . . . . . . . . . . . . . . . . . . 17
iv
Bizfon Conference Series Phone User’s Guide
Section 1
Introduction
Overview
The Bizfon Conference Series Phone is a
high-performance, full duplex conference
room phone with exceptional sound quality.
It is easy to use and will ensure that you
always receive high fidelity sound during
your conference calls.
System Features
•
Digital Signal Processing (DSP) pro-
vides intelligent microphone mixing for
precision voice pick up.
•
•
Full duplex operation.
Three noise canceling microphones pro-
vide 360 degree pick-up and filter out
background noise.
•
•
Hi-fidelity speaker provides distortion-
free audio.
Auto Gain Control based on room area
means you do not have to adjust input
volume.
•
Convenient integrated keypad so no sep-
arate telephone is needed.
•
•
•
Standard analog line compatible.
Power switch with LED indicator.
Mute button with LED indicator mutes
microphones.
•
Digital volume control for receiver and
ringer.
Bizfon Conference Series Phone User’s Guide
1
Introduction
•
•
•
•
Flash button to access call waiting.
Tone/Pulse switchable.
Ringer on/off switch.
Jack to connect recording device to
record conference call.
Input Jacks
The input jacks are on the bottom of the
speakerphone.
•
The phone jack acts as a power source
from the power adapter to the speaker-
phone.
•
•
The record output jack allows you to
connect a recording device.
The data jack allows you to connect a fax
machine or a modem. Do NOT connect a
fax or modem if your Bizfon Conference
Series Phone is connected to a Bizfon
680.
Parts Included
with Your Con-
ference Phone
The following are included with your confer-
ence phone:
•
•
AC power adapter 120VAC
One 25-foot telephone cord to connect
the conference phone to the power
adapter.
•
•
One 7-foot line cord to connect the line
jack of the power adapter and wall jack.
This User’s Guide.
2
Bizfon Conference Series Phone User’s Guide
Section 2
Getting Started
Installing the
Bizfon Confer-
ence Series
Phone
To install your conference phone, follow
these steps:
1. Find a suitable location for the confer-
ence phone such as in the middle of a
conference room table. The ideal room
size is no larger than 10 by 20 feet.
2. Insert one end of the LONG telephone
cord into the PHONE jack on the power
adapter.
3. Insert the other end of the LONG tele-
phone cord into the PHONE jack on the
conference phone and be sure to run the
cord under the cord clip.
4. Insert one end of the SHORT telephone
cord into the LINE jack of the power
adapter.
5. Insert the other end of the SHORT cord
into any available extension port on your
Bizfon 680.
If you are not using a Bizfon 680, con-
nect the line cord to standard telephone
wall jack
6. Plug in the power adapter to a standard
AC outlet.
NOTE: If the conference phone does not work after
you plug it in, verify that you have connected
the LONG and SHORT cords correctly.
Bizfon Conference Series Phone User’s Guide
3
Getting Started
Data Jack
Phone Jack
Connect fax machine
or modem if phone is
NOT connected to a Bizfon 680.
Connect LONG cord from here to PHONE
jack on power adapter and
slide under cord clip.
Recorder Jack
Tone/Pulse Switch
Ringer On/Off Switch
Ensure that the switch is set to T.
Set to P only if you do not have touchtone
service and the conference phone is not
connected to a Bizfon 680.
Figure 1. Bottom View of Bizfon Conference Series Phone
4
Bizfon Conference Series Phone User’s Guide
Getting Started
Connect SHORT cord from
LINE jack of power adapter
to an extension port on your
Bizfon 680 or a standard
telephone jack.
Connect LONG cord
from PHONE jack of
power adapter to
PHONE jack on con-
ference phone.
Figure 2. Power Adapter
After you plug in the conference phone, it
plays a static sound and five short tones as it
scans the room. This automatically deter-
mines the room size and the conference
phone adjusts itself for optimum sound qual-
ity. The conference phone is now ready to
receive or make calls.
Setting up the
Extension to
If your conference phone is not connected to
a Bizfon 680, you may skip this section.
Which the Con-
ference Phone
is Connected
When you first use the conference phone,
you are prompted to set up the extension if
you have not previously done this. Refer to
the Bizfon 680 Owner’s Guide for details
about resetting and setting up extensions.
The first time you press POWER, the system
prompts you with the following:
Bizfon Conference Series Phone User’s Guide
5
Getting Started
“Welcome to extension 201 <the number
of the extension to which the conference
phone is connected>. To set up this
extension now, press 1; otherwise, press
*.”
If you press ꢀ to set up the extension, you
are prompted through a series of options to
configure the extension. Simply follow the
prompts to configure the extension.
NOTE: If you have a Bizfon 680 version 2.0, you
hear an option specifically for the conference
telephone. If you have an older Bizfon 680,
press ꢀ again.
TIP: If you use your conference phone in a public
place, such as a conference room, you might
want to configure it to not use voice mail.
When prompted, select the option for “If this
extension is in a public place ...”
•
You can press ꢁ to defer setting up your
extension.
You then receive a dial tone and can
place calls.
6
Bizfon Conference Series Phone User’s Guide
Section 3
Using Your Bizfon
Conference Series Phone
This section tells you how to make and
receive telephone calls and how to use the
features of your conference phone.
Press to turn off/on microphones
Press to answer call-waiting
Press – or + to adjust
Press to make or answer a call
speaker or ringer volume
Making a Call
To make a call:
1. Press POWER.
2. When you hear the dial tone, dial the
number that you wish to call.
To make an outside call, press ꢂ.
To end the call, press POWER.
Bizfon Conference Series Phone User’s Guide
7
Using Your Bizfon Conference Series Phone
Answering
Incoming Calls
To answer incoming calls, press POWER.
To end the call, press POWER again.
Using Your Con- Flash
Use FLASH if you have call waiting acti-
vated and a call comes in when you are
already on the conference phone.
ference Phone
Features
You hear two beeps if another call comes in
while you are on the conference phone.
Press FLASH to connect to the other call
while putting the current call on hold. Press
FLASH again to return to the previous call.
Mute
To turn off the microphones, press MUTE.
This is useful if you need to have a private
conversation with those in the room, but do
not want anyone on the other end of the call
to listen.
Press MUTE again to activate the micro-
phones.
You can still hear incoming audio when mute
is active.
The LEDs for each microphone light when
you press MUTE. Mute works during a call
only.
8
Bizfon Conference Series Phone User’s Guide
Using Your Bizfon Conference Series Phone
Volume Control
During a call, to increase the speaker vol-
ume, press the + side of VOLUME. To
decrease the volume, press the – side of
VOLUME. When you start a new call, the
volume is set to its middle setting regardless
of where it was when you ended the previous
call.
When not on a call, VOLUME controls the
ringer volume. To increase the ringer vol-
ume, press +. To decrease the volume,
press –. Each time you increase or decrease
the ringer volume, the conference phone
rings at that volume setting.
Ringer On/Off
If you do not want the conference phone’s
ringer to sound, move the switch to OFF.
The ringer switch is on the bottom of the
conference phone.
Getting Better
Performance
To ensure optimal performance from your
conference phone, follow these guidelines:
from Your Con-
ference Phone
•
•
•
•
Conference participants should be within
six feet of the conference phone.
Place the conference phone in the center
of the conference table.
Avoid placing any objects near the
microphones.
Speak at a normal volume during a con-
ference call.
Bizfon Conference Series Phone User’s Guide
9
Using Your Bizfon Conference Series Phone
•
•
•
Do not move the conference phone dur-
ing the conference call.
Set the volume at a level that everyone
can hear.
Avoid placing the conference phone in
noisy environments. If you cannot avoid
noisy environments, participants should
be closer to the conference phone.
•
Run any cords connected to the confer-
ence phone under the cord clips to ensure
that the conference phone sits flat on the
table.
10
Bizfon Conference Series Phone User’s Guide
Regulatory and Safety Information and Specifications
Section 4
Regulatory and Safety
Information
and Specifications
FCC Statement: Part 68
This equipment complies with FCC rules, Part 68. On the BOTTOM of
this equipment is a label that contains, among other information, the
FCC Registration Number and Ringer Equivalence Number (REN) for
this equipment. If requested, provide this information to your telephone
company.
The (REN) is useful to determine the quantity of devices you may con-
nect to your telephone line and still have all of those devices ring when
your number is called. In most, but not all areas, the sum of the RENs
of all devices should not exceed 5.0. To be certain of the number of
devices you may connect to your line, as determined by the REN, you
should call your local telephone company to determine the maximum
REN for your calling area.
If this equipment causes harm to the telephone network, the Telephone
Company may discontinue your service temporarily. If possible, they
will notify you in advance. But if advance notice isn’t practical, you
will be notified as soon as possible. You will be advised of your right to
file a complaint with the FCC.
Your telephone company may make changes in its facilities, equip-
ment, operations, or procedures that could affect the proper operation
of your equipment. If they do, you will be given advance notice to give
you an opportunity to maintain uninterrupted service.
If you experience trouble with this equipment, please contact the manu-
facturer for warranty/repair information. The Telephone Company may
Bizfon Conference Series Phone User’s Guide
11
Regulatory and Safety Information and Specifications
ask that you disconnect this equipment from the network until the prob-
lem has been corrected or until you are sure that the equipment is not
malfunctioning.
This equipment may not be used on coin service provided by the Tele-
phone Company. Connection to party lines is subject to state tariffs.
FCC rules prohibit the use of non-hearing aid compatible telephones in
the following locations or applications:
(1) All public or semipublic coin-operated or credit card telephones.
(2) Elevators, highways, tunnels (automobile, subway, railroad or
pedestrian) where a person with impaired hearing might be isolated in
an emergency.
(3) Places where telephones are specifically installed to alert emer-
gency authorities such as fire, police, or medical assistance personnel.
(4) Hospital rooms, residential health care facilities, convalescent
homes, and prisons.
(5) Workstations for the hearing impaired.
(6) Hotel, motel, apartment lobbies; in stores where telephones are used
by patrons to order merchandise; in public transportation terminals
where telephones are used to call taxis, or to reserve lodging or rental
cars.
(7) Hotel and motel rooms. At least ten percent of the rooms must con-
tain hearing aid compatible telephones; or jacks or plug-in hearing-aid
compatible telephones which will be provided to hearing impaired cus-
tomers upon request.
12
Bizfon Conference Series Phone User’s Guide
Regulatory and Safety Information and Specifications
FCC Statement: Part 15, Class A
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits for
a Class A digital device, pursuant to Part 15 of the FCC rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following mea-
sures:
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
You may also find helpful the following booklet, prepared by the FCC,
“How to Identify and Resolve Radio-TV Interference Problems.” This
booklet is available from the U.S. Government Printing Office, Wash-
ington D.C. 20402.
Changes and Modifications not expressly approved by the manufac-
turer or registrant of this equipment can void your authority to operate
this equipment under Federal Communications Commission rules.
Bizfon Conference Series Phone User’s Guide
13
Regulatory and Safety Information and Specifications
Canadian DOC Statement
“This digital apparatus does not exceed the Class A limits for radio
noise emissions from digital apparatus set out in the Radio Interference
Regulations of the Canadian Department of Communications.”
“Le present appareil numerique n’emet pas de bruits radioelectriques
depassant les limites applicables aux appareils numeriques de la class
A prescrites dans le Reglement sur le brouillage radioelectrique edicte
par le ministere des Communications du Canada.”
Industry Canada Notice
The Industry Canada label identifies certified equipment. This certifi-
cation means that the equipment meets telecommunications network
protective, operation and safety requirements as prescribed in the
appropriate Terminal Equipment Technical Requirements document(s).
The Department does not guarantee the equipment will operate to the
user's satisfaction. Before installing this equipment, users should
ensure that it is permissible to be connected to the facilities of the local
telecommunications company. The equipment must also be installed
using an acceptable method of connection. The customer should be
aware that compliance with the above conditions may not prevent deg-
radation of service in some situations.
Repairs to certified equipment should be coordinated by a representa-
tive designated by the supplier. Any repairs or alterations made by the
user to this equipment, or equipment malfunctions, may give the tele-
communications company cause to request the user to disconnect the
equipment.
Users should ensure for their own protection that the electrical ground
connections of the power utility, telephone lines and internal metallic
water pipe system, if present, are connected together. This precaution
may be particularly important in rural areas.
14
Bizfon Conference Series Phone User’s Guide
Regulatory and Safety Information and Specifications
: Users should not attempt to make such connections them-
CAUTION
selves, but should contact the appropriate electric inspection authority,
or electrician, as appropriate.
: The Ringer Equivalence Number (REN) assigned to each
NOTICE
terminal device provides an indication of the maximum number of ter-
minals allowed to be connected to a telephone interface. The termina-
tion on an interface may consist of any combination of devices subject
only to the requirement that the sum of the Ringer Equivalence Num-
bers of all the devices does not exceed 5.
Important Safety Instructions
Some of the following information may not apply to your particular
product; however, when using telephone equipment, basic safety pre-
cautions should always be followed to reduce the risk of fire, electric
shock and injury to persons, including the following:
1. Read and understand all instructions.
2. Follow all warnings and instructions marked on the product.
3. Unplug this product from the wall outlet before cleaning. Do not
use liquid cleaners or aerosol cleaners. Use a damp cloth for clean-
ing.
4. This product should not be used while you are in a bathtub, shower
or pool. Immersion of the product in water could cause an electrical
shock.
5. Slots and openings in the cabinet back or bottom are provided for
ventilation, to protect it from overheating. These openings must not
be blocked or covered. The openings should never be blocked by
placing the product on the bed, sofa, rug, or other similar surface.
This product should not be placed in a built-in installation unless
proper ventilation is provided.
6. This product should be operated only from the type of power source
indicated on the marking label. If you are not sure of the type of
power supply to your home, consult your local power company.
7. Do not allow anything to rest on the power cord. Do not locate this
product where the cord will be abused by persons walking on it.
8. Do not overload wall outlets and extension cords as this can result
in the risk of fire or electric shock.
Bizfon Conference Series Phone User’s Guide
15
Regulatory and Safety Information and Specifications
9. Never push objects of any kind into this product through cabinet
slots as they may touch dangerous voltage points or short out parts
that could result in a risk of fire or electric shock. Never spill liquid
of any kind on the product.
10. To reduce the risk of electric shock, do not disassemble this prod-
uct. Opening or removing covers may expose you to dangerous
voltages or other risks. Incorrect reassembly can cause electric
shock when the appliance is subsequently used.
11. Do not expose this product to extreme temperatures such as found
near a hot radiator or stove, or in a car parked in the summer sun.
12. Do not place lighted candles, cigarettes, cigars, etc., on this prod-
uct.
13. Never touch uninsulated telephone wires or terminals unless the
telephone line has been disconnected at the network interface.
14. Never install or modify telephone wiring during a lightning storm.
15. Never install telephone jacks in wet locations unless the jack is spe-
cifically designed for wet locations.
16. Use caution when installing or modifying telephone lines.
17. Unplug this product from the wall outlet and refer servicing to qual-
ified service personnel under the following conditions:
A. When the power supply cord or plug is damaged or frayed.
B. If the product has been exposed to rain or water.
C. If the product does not operate normally by following the oper-
ating instructions.
D. If the product has been dropped or the cabinet has been dam-
aged.
E. If the product exhibits a distinct change in performance.
18. Avoid using a telephone (other than a cordless type) during an elec-
trical storm. There may be a remote risk of electric shock from
lightning.
19. Do not use this product to report a gas leak in the vicinity of the
leak.
20. Do not place this product on an unstable cart, stand or table. The
product may fall, causing serious damage to the product.
16
Bizfon Conference Series Phone User’s Guide
Regulatory and Safety Information and Specifications
Specifications
Size: 106 in. x 9.8 in. x 3.5 in.
Weight: 2.4 pounds (net weight with acces-
sories)
Environmental Operating Temperature:
41 to 95 degrees F.
Power Adapter: AC Adapter, 18V 100mA
Phone Line Cord: 25 feet
Line Cord: 7 feet
Phone Line Jack: (USOC) RJ14C
Data Port Jack: 623P (RJ11)
Recording Jack: 2.5mm
Keypad: Alphanumeric
Bizfon Conference Series Phone User’s Guide
17
|