Product Manual
ICC2-IRC / ICW-IRC
IR TV Controller
Ver. 2.5 October 30, 2002
17630 Davenport Rd, Suite113
Dallas, TX 75252 USA
Tel:
972.931.2728
888.972.2728
Fax: 972.931-2765
Overview
Contemporary Research offers two solutions for intelligent, interactive distributed media management, the
ICC2-IRC and ICW-IRC IR TV Controllers. The ICC2-IRC communicates bi-directionally over the same RF coax
that carries the broadband TV channels, dramatically simplifying system wiring. The ICW-IRC connects over a
twisted-pair network using Category 5 or Category 3 wiring and connectors.
Both IRC TV Controllers feature an internal TV tuner for absolute channel access management and a character
generator that outputs on-screen text for channel names, control functions, and interactive menus. Intelligent
tuning, volume and power control is provided by IR control port and included scan sensor. Front-panel control
and LEDs keep users in touch with their system. Enjoy a full range of control choices with the included
IC-RC IR Wireless Remote, designed for simplified control of distributed media channels and sources.
Compatible with the Contemporary Research ABC Media Retrieval System and iC Commander software, the IRC
TV Controllers can be networked with up to 4000 TV and Video Display controllers. For custom systems
applications, all IRC units and other iC-Net devices can be accessed from a single RS-232 port on ICC-HE and
ICW-HE Head-End Network Controllers.
•
Controls most brands of TVs from IR control port
o
Creates on-screen channel labels, messages, text menus, and feedback using onboard
character generator
o
Receives wireless commands from included IC-RC IR remote from internal IR sensors, external
sensor optional
o
o
o
Delivers absolute volume control for level and mute
Manages channel access using programmable available channel list
Delivers absolute power control with included power sensor
•
•
Networks with up to 4,000 TVs through an ICC-HE or ICW-HE Head-End Network Controller
o
o
o
ICC2-IRC units provide 2-way operation over the same RF cable as CATV channels
ICW-IRC connect over Category 3 or 5 wiring
Units instantly respond to individual, zone, and all-call commands
Provides front-panel control for power, volume, and channel, and LED feedback for power, IR control,
and network
•
•
•
•
Includes A/V inputs to display video from PCs, overheads, cameras and other local video sources
Restores all operation status after loss of power from data stored in non-volatile memory
Enables and disables front-panel control via iC-Net protocol
Mounts above, below, or near TV, mounting brackets included over the same RF coax as the distributed
media channels, simplifying system wiring and retrofit
Contemporary Research Corporation
3
IR TV Controller
Specifications
Physical
Size:
8.5" [216mm] wide x 1.75" [38mm] height (1RU) x 6.0" [153mm] deep
Weight:
Enclosure:
Mounting:
1.5 lbs [0.68kg]
All aluminum with durable black powder coat paint
Mounts above or below TV, optional RK2 brackets available
Front Panel
Push Buttons:
Power LED:
Net LED:
Channel up and down, Volume up and down, and Power
Red LED lights when TV is on
Green LED for iC-Net bus, flashes once per second if active
Red LED lights when receiving IR commands from remote
Red LED lights when sending IR commands
IR In LED:
IR Out LED:
Volume Up/Down:
Buttons adjust volume of IRC audio output
Channel Up/Down: Buttons select list of channels stored in IRC Tune Ring
Rear Panel
Power In:
2.1mm coaxial jack (inside center conductor positive), 350 Ma maximum
11.5 to 16.5 VDC, 12 VDC typical (may be unregulated)
North American version includes UL/CSA listed wall power supply
3.5mm jack for optional CC-HSD scan sensor or 5V logic-level input
3.5mm jack for CC-IRE IR Emitter cable or compatible CC-IRS serial cable
Supports carrier frequencies up to 62 KHz
Power Sensor:
IR Out:
Shipped with CC-IRE cable, 10 foot with stick-on IR emitter
‘F’, female, 75 ohm impedance
Video - RCA female, NTSC composite
Antenna/Cable:
A/V Inputs:
Audio – 2 RCA female, mono 20K ohms unbalanced
Video - RCA female, NTSC composite
A/V Outputs:
Audio – 2 RCA female, mono 1K ohms, 20Hz to 20KHz
0.5% maximum, 0.1% typical THD, 500mV RMS typical at max volume
Volume control 0 to -62 dB and mute in 64 steps
Mounting hole for optional external IR sensor input jack
IR In
Internal Closures
Type:
2 Solid-State output switch closures, max 50 mA, 24 VDC
Closure 1 normally used for optional buzzer
Closure 2 normally used for an external camera power relay (by others)
Available as factory-installed option only
Contemporary Research Corporation
4
IR TV Controller
RF Tuner
Frequency Range:
NTSC television 55.25 to 801.25 MHz, 62.5KHZ fine tune resolution
+20dBmV
±5% maximum, 2% typical
Maximum Input:
Video Gain:
Video Phase:
±3 degrees maximum, 2 degrees typical
iCC-Net (ICC2-IRC)
Operation:
Carried over the same RF coax connection as TV channels
Mid-band VHF, 74.7MHz, sent from IC Head-End Network Controller
-25 to +35 dBmV signal level
Data Receive:
Data Transmit:
Sub-band, 5.6MHz sent to Head-End Network Controller
± 80 KHz max carrier deviation
+49dBmV nominal
iCW-Net (ICW-IRC)
Connector
RJ-45 female 8 pin Telco jack
RS-485 type data requiring at least 2 twisted wire pairs with shield or fifth conductor
Recommended Wire: CAT3/CAT5 compatible unshielded, max 3300 feet [914m] from iC Head End
CC-HSD Scan Sensor
Range:
Includes:
Senses presence of TV scanning, from 15-35 KHz, magnetic pick-up
3.5mm plug, 4ft. cable, stick-on TV sensor
Status Indication
The Net and Power LEDs have special modes that help system setup and troubleshooting.
Power LED
Uses a blink mode when the IRC logic and Sensor feedback do not agree
Logic Sensor LED Response
ON
ON
OFF
OFF
ON
OFF
OFF
ON
Solid On
Blinks – states do not agree
Solid Off
Blinks – states do not agree
For example, if the TV Controller knows the TV should be on, but the sensor
input does not see scanning activity, the Power LED blinks rapidly.
Net LED
Blinks when it is receiving network data
LED Response
Off – DC power to IRC missing or other internal power problem
Solid On – no network communication
Blinks once per second - communicating over network
The Head-End Network Controller sends out a “heartbeat” command once every
second that will flash the Net LED.
Contemporary Research Corporation
5
IR TV Controller
Installation
AC Power
1. Insert DC power supply plug into 12 VDC jack on the IRC.
2. Plug power adaptor into AC wall outlet.
3. The Net LED should turn on and stay lit.
RF Coax and iCC-Net Operation
1. Connect the RF Coax cable into the Antenna/Cable input on the IRC.
2. If the iCC-Net signal is operating, the Net LED will blink once per second (ICC2-IRC only).
iCW-Net Connection (ICW-IRC)
1. Plug the iCW-Net RJ-45 connector into the iCW-Net input on the ICW-IRC.
2. If the iCW-Net signal is operating, the Net LED will blink once per second.
TV Power Sensing
1. Press the Power button on the IRC.
2. The Power LED should blink, indicating that the IRC knows the TV should be on, but is not sensing the
presence of TV scanning operation.
3. Insert the CC-HSD Scan Sensor plug into the IRC Power Sensor jack.
4. Turn on the TV using the TV’s power button.
5. Move the CC-HSD sensor block around the rear of the TV to pick up scanning signal from the TV’s
horizontal transformer
6. Watch the IRC Power LED as you move the sensor, stop moving when the LED stops blinking.
7. Turn the TV on and off from its own power button, testing if the IRC is reliably sensing power.
8. Mount the sensor to the TV, using the enclosed Velcro tape.
Tip:
The best location for the sensor is usually on the lower left rear corner side corner (looking
from the front), and it may help to rotate the sensor to search for best performance.
Contemporary Research Corporation
6
IR TV Controller
A/V Setup
1. Connect audio and video outputs of the IRC into the audio and video inputs of the TV.
2. You may use the left or right IRC audio output for a TV with mono audio, both for a TV with stereo audio
(IRC sound is mono).
3. Select the External Video/Aux inputs on the TV to view on-screen setup commands and A/V from the IRC
(Most TVs don’t have a discrete Video input command).
IR Control Wiring
1. Connect the CC-IRE IR Emitter plug into the IRC IR Out jack.
2. Mount the emitter cube to the TV case where the TV receives IR commands.
3. Place the IRC near the TV within line-of-sight control from the IC-RC wireless IR remote. At this point,
you could fix the IRC into the final mounting position above or below the TV, or simply place the IRC so
you can complete the IR setup procedure.
Tip: At this point, you’ve set up the control wiring, the manufacturer’s codes sent will be
programmed or changed with the On-Screen Setup Menu 45700. Press the Power button on
the IRC. If the TV turns on and off, the settings are already correct.
IR Mode and Power Sensing
Newer IRC models set the IR and Sensing options via the On-Screen Setup Menu 45702. Some ICW-IRC units
include a DIP switch (S6), located inside the IRC, to set IR options and TV Power sensing. Note this affects the
front-panel sensing, not an external IR sensor. Turning off both sensors would limit sensing to the external IR
sensor only. If you have two adjacent TVs (or one on each side of a wall), you may want to lower TV power
sensing. Some TVs prefer a lower IR output, most work fine with the standard level.
Switch # Function
Options
1
2
3
4
38 KHz IR Receive
ON= 38 KHz IR
OFF= 38 KHz IR off (default)
ON= 57 KHz IR (default)
OFF= 57 KHz IR off
ON= High sensitivity (default)
OFF= Low sensitivity
ON= High IR output (default)
OFF= Low IR output
57 KHz IR Receive
TV Power Sensing
IR Control Output
Programming the IC-RC Remote
In order to complete the setup of the IRC, you’ll need the IC-RC IR Remote to use the On-Screen Menus.
Typically, the remote is shipped ready to communicate to the IRC (Code 9). Just in case, here’s how to set the
format of IR codes in the remote:
1. Press and hold the Select button and a numeric key for the code # below.
2. Release the two keys at the same time.
3. The remote will now send the selected codes.
4. Remote will keep the codes, even if battery power is lost.
IR Code Format
Code
Zenith Smart TV
Philips Smart TV
RCA Smart TV
Contemporary Research 38 KHz
Contemporary Research 57 KHz (default)
1
2
3
4
9
Tip:
Normally, the 57 KHz frequency works the best, avoiding most sources of IR interference.
The IRC has 38 KHz and 57 KHz sensors, so it can receive either frequency.
Contemporary Research Corporation
7
IR TV Controller
On-Screen Setup Menus
The remaining installation steps use the IR remote and the built-in character generator of the IRC.
1. Touch Menu, then 999, then Enter.
2. The text CR MENU> should appear on the screen.
3. Key in one of the commands shown below, then press Enter to activate.
4. Note that, in Menu mode, the Channel Down key acts as a backspace/delete key.
Command
All
Function
The following commands are used for all IRCs
Display IRC firmware version
Display the unit’s Device #. At this point, you can use the Channel Down key as a
Delete key, enter a new device # with the remote’s numeric keypad, then hit Enter
to save the new number.
45678
45679
45700
Display or edit IR device type. Sets the IR control format to match your TV. In many
cases, CR can pre-set this command to the format specified by the dealer.
0=None
1=Zenith [added V2.0]
2=Panasonic [added V1.7]
3=Toshiba [added V2.0]
4=Hitachi [added V2.0]
5=Sony [added V2.0]
6=Grundig [added V2.0]
7=Magnavox/Philips [added V1.7]
8=RCA [added V2.0]
9=Sony_2 [added V2.0]
10=Panasonic_2 [added V1.9]
11=Mitsubishi [added V2.0]
12=Monivision (old) [added V1.6]
13=Monivision (new) [added V1.8]
14=Panasonic_3 [added V1.9]
15=Sharp [added V2.1]
16=Pioneer (plasma) [added V2.3]
17=NEC (plasma) [added V2.3]
18 = Samsung [added 2.5]
45702
Set IR receive, IR output and power sensing levels.
1 = Enable 38KHz IR receive in, 0=disable
2 = Enable 57KHz IR receive in, 0=disable
4 = Enable IR output carrier, 0=no carrier
8 = Set power sensor for high sensitivity, 0=low sensitivity
16 = Set IR output for high current, 0=low current
Add up the values and enter the result. For example, the default setting is 30 (57
KHz on, IR carrier, high power sensitivity, and high IR output).
Reset IRC, similar to disconnecting power then restarting.
Initialize IRC to factory default settings: Power on, unlocked, display channel 11,
channel ring set to 4, 5, and 11, Group 0. Note that this command works even if TV
power is off or control is locked out.
65478
65487
65482
Shows Net RX if receiving the iC-HE’s “heartbeat” pulse once per second, !NET RX
if not. Also displays receive signal strength in the ICC2-IRC.
ICC2-IRC
The following commands are used for the ICC2-IRC only
65480
Enable constant Net transmit to the Head-End. This is used for measuring the signal
strength of the ICC2-IRC’s RF output. Press Enter to stop transmitting, or the unit
will automatically stop after 50 seconds.
65481
65483
Display ICC2 transmitter frequency control voltage – should be 2000 - 3150.
Display DF transmitter frequency deviation – should be 245 - 300.
Contemporary Research Corporation
8
IR TV Controller
RS-232 Control Protocol
Overview
RS-232 control for up to 4000 ICC2-IRC and ICW-IRC TV Controllers is provided through an iC-series Head-End
Network Controller. The ICC-HE Head-End manages iC-Net communication over RF Coax to ICC2-IRC TV
Controllers as well as ICW-IRC TV Controllers over twisted-pair Cat3/5 wiring. The ICW-HE Head-End operates
on the twisted-pair network only.
Each TV Controller is assigned a unique device number from 1 to 4000 to which control commands are
addressed. The devices are organized into 16 zones of 255 devices. All the devices in each zone will respond to
a single “virtual device number” — one device number that represents all devices in each zone. There is also a
global device number, 4095, that will command all devices in the system. This feature dramatically speeds up
system operation and programming, because one command can affect an entire group of devices—or all. To
take advantages of this feature, review the section iC-Net Zones in this manual.
In ABC Media Retrieval Systems, we reserve the first group of devices, 1-255, for components operating on a
connected control system. Zones 1-16 are used for CR TV Controllers, Video Display Controllers and Tuners. As
it’s unlikely any system will use all 4000 devices, this may be a good device standard for your system as well.
The Remote RS-232 port on the Head-End Network Controller can communicate from 1200 to 38.4K baud. The
factory default setting is 19.2K baud, 8 data bits, No parity, and 1 stop bit.
Command String Structure
Characters in command strings are expressed in a combination of hex and ASCII characters. For clarity, the
following protocol examples use the following conventions:
•
•
•
•
•
•
•
Single-byte hex numbers are preceded by the ‘$’ symbol
ASCII characters or strings are enclosed in single quotes
Numbers not marked as hex or ASCII are a single decimal byte
Parameters shown in < > brackets are single byte
A series of multiple commands or parameters are set apart by [ ] brackets
Commas separate the bytes, but are not part of the protocol
Double quotes enclose the command string, but are not part of the protocol
Command format:
“$A5,<dh>,<dl>,<ncb>,<cmd1>,<parameter> [<cmdN>]"
$A5
<dh>
<dl>
<ncb>
<cmd1>
Starts the command
The zone or high order byte of the device
The unit or low order byte of the device (0 for global zone)
The number of command bytes to follow
The first command byte
<parameter> Command parameters (not used by all commands)
[<cmdN>] Multiple commands can be concatenated, with byte count added to <ncb>
Contemporary Research Corporation
9
IR TV Controller
RS-232 Commands
Command
Power Off
Description
PO “$A5,<dh>,<dl>,2,’P0’ ” (6 bytes) – checks sensor for true power control
Power On
P1 “$A5,<dh>,<dl>,2,’P1’ ” (6 bytes) – checks sensor for true power control
PT “$A5,<dh>,<dl>,2,’PT’ ” (6 bytes) – checks sensor for true power control
TM “$A5,<dh>,<dl>,3,’TM’,<setting>” (7 bytes)
Power Toggle
Operating
Parameters
Sets up key functions in the IRC
bit 7 – 3 = 0
bit 2 – Channel up/down operation, 0=Tune Ring, 1=Send IR Keypad response
bit 1 – Numeric channel labels, 0=num labels off, 1=num labels on)
bit 0 – Alpha channel labels, 0=alpha labels off, 1=alpha labels on
VL “$A5,<dh>,<dl>,3,’VL’,<vol level>” (7 bytes)
Volume
Sets IRC volume level
0 = Mute
1 – 63 = Minimum level (1) to maximum volume (63)
Power-up
Volume
S5 "$A5,<dh>,<dl>,3,'S5',<volume>" (7 bytes)
Sets volume level when IRC powers up
0 = restore to previous level
1 – 63 = Set from minimum (1) to maximum level (63)
T-series channel commands select a channel and display the channel label on the TV,
while Q-series commands don’t show the on-screen text.
TU “$A5,<dh>,<dl>,2,’TU’ ” (6 bytes) – Tunes to next channel up in Tune Ring
Ts & Qs
T Channel Up
T Channel Dwn TD “$A5,<dh>,<dl>,2,’TD’ ” (6 bytes) – Tunes to next channel down in Tune Ring
Force T Channel TC “$A5,<dh>,<dl>,3,’TC’, <channel>” (7 bytes) – Tunes to a specific channel
124 = RGB 2 input on TV
125 = RGB input on TV
126 = Select IRC external A/V input (also selects TV video input)
127 = Select S-Video Input
0 = Blank video output to TV
255 = Unblank TV video (restore to previous channel)
Tip: Not all inputs are available on every TV make and model.
Select T Channel
TT “$A5,<dh>,<dl>,2,’TT’ ” (6 bytes) – Tunes channel if included in Tune Ring
Channel Query T? “$A5,<dh>,<dl>,2,’T?’ ” (6 bytes) – Request response for current channel
Q Channel Up QU “$A5,<dh>,<dl>,2,’QU’ ” (6 bytes) – Tunes to next channel up in Tune Ring
Q Channel Dwn QD “$A5,<dh>,<dl>,2,’QD’ ” (6 bytes) – Tunes to next channel down in Tune Ring
Force Q Chan
QC “$A5,<dh>,<dl>,3,’QC’, <channel>” (7 bytes) – Tunes to a specific channel
Same special-function channels as in the T Channel Select section above
QT “$A5,<dh>,<dl>,2,’TT’ ” (6 bytes) – Tunes channel if included in Tune Ring
Select Q Chan
Contemporary Research Corporation
10
IR TV Controller
Command
Description
Tuner Mode
SO "$A5,<dh>,<dl>,3,'S0',<tune mode>" (7 bytes)
Sets tuner mode to CATV or Broadcast/Antenna
0 = CATV
1 = Broadcast/Antenna
2 = HRC
Tune Ring
TR “$A5,<dh>,<dl>,<ncb>,’TR’, [<chan 1>, <chan N>]” (variable bytes)
This command stores a Tune Ring, a series of preset channels accessed by channel
up/down commands.
Ex1: “$A5,<dh>,<dl>,6,’TR’, 5,4,8,11” sets ring to channels 5, 4, 8 and 11
Tip: The ring follows the stored order, channels do not have to be in ascending
order
x Ex2: “$A5,<dh>,<dl>,2,’TR’ ” clears the Tune Ring, locks unit to current channel
Tip: In the above mode, the IR Keypad channel up/down response to the Head-
End, so the system will know the user is trying to change channels. In
response, the system could change channels on a media sources, like a VCR or
satellite.
Ex3: “$A5,<dh>,<dl>,8,’TR’, $82,5,$87,11” sets channels 2-5 and 7-11. You can
specify a range using MSB bit for the first channel; the next byte is the last.
Channel Labels TN “$A5,<dh>,<dl>,<ncb>,‘TN’,<channel>,<label>” (variable bytes)
Stores an ASCII string as the channel label. The text will appear briefly when the
channel is selected, if the feature has been activated by IRC Setup command (TM).
Ex1: “$A5,<dh>,<dl>,3,‘TN’, ‘7’, ‘PBS’ ” IRC displays PBS when 7 is selected
Ex2: “$A5,<dh>,<dl>,3,‘TN’, ‘7’ ” Clears alpha label for channel 7
Ex3: “$A5,<dh>,<dl>,3,‘TN’,0,0” Clears all alpha labels
Display Label
Closures
TC “$A5,<dh>,<dl>,2,’TC’ ” (6 bytes) – Display current channel label for about 15
seconds
Y-
“$A5,<dh>,<dl>,3, ‘Y’ <I/0 Port>’ ” (7 bytes)
Turns the two internal closures on and off. Closure 1 is typically used to control the
optional buzzer, Closure 2 typically used to control an external camera power relay.
“$A5,<dh>,<dl>,3, ‘Y10’” turns Closure 1 off
“$A5,<dh>,<dl>,3, ‘Y11’” turns Closure 1 on
“$A5,<dh>,<dl>,3, ‘Y20’” turns Closure 2 off
“$A5,<dh>,<dl>,3, ‘Y21’” turns Closure 2 on
Control Lock
Device Status
LM “$A5,<dh>,<dl>,3,'LM',<control>” (7 bytes)
Locks out front panel and IR remote control functions.
Bit 7
Bit 6
Selects IR remote control operation (0=enabled, 1=disabled)
Selects volume control operation (0=enabled, 1=disabled)
Bit 5 - 1 Always 0
Bit 0
Selects IRC front panel buttons operation (0=enabled, 1=disabled)
SP "$A5,0,0,3,'SP'" (6 bytes)
Queries the Head-End for the number of devices present on the network and the
number of devices expected.
Contemporary Research Corporation
11
IR TV Controller
Command
Write Text
Description
DM “$A5,<dh>,<dl>,<ncb>,‘DM’, <start line>,<text color>,<background color>,
<background>,<size and shadow>,<timeout>,<message bytes>” (variable bytes)
Clears current text, displays text message over video (default) or blank background.
The built-in character generator can accept up to 40 characters of text (including
carriage returns), 28 characters per line. Use a hex $0D or decimal 13 in the text as
a carriage return, which will advance CG to the next line, first space on the right.
Start Line - 1-11
Text Color - 1-7= White
Text Background Color – 0-7=Transparent (no background)
Full screen background – 0=normal insert over video, 1=blank screen (blue)
Size and Shadow – 0-3=small text with drop shadow
Time-Out – 0=15-second display, 1=persistent
Persistent text stays on screen until the next DM, or new Menu or channel.
Ex1: “$A5,<dh>,<dl>,10,‘DM’, 2,7,0,0,1,0,’TEST’ ” displays the word TEST on the
second line, white text, inserted over video, small size with drop shadow, and timing
out after 15 seconds.
Ex2: “$A5,<dh>,<dl>,2,‘DM’ ” clears on-screen display, also clears persistent text
The VDC uses white text and clear backgrounds when it receives a Text or
Background Color parameter between 1 and 7, and accepts values 0-3 for text size
and shadow. This allows compatibility with Smart TVs mixed in the same system that
can display other colors and fonts.
Fast Write
DN “$A5,<dh>,<dl>,<ncb>,’DN’, <text> ” (variable bytes)
Clears display, writes specified text starting at column 1, row 1. $0D and hex $EA,
$EB, $DC, and $DB can be included, operate same as matching commands below.
DW “$A5,<dh>,<dl>,<ncb>,’DW’, <text> ” (variable bytes)
Write Here
Writes specified text starting at present cursor position. Accepts same Hex as DN.
Row, Column
DG “$A5,<dh>,<dl>,4,’DG’, <row>, <column>” (8 bytes)
Moves the cursor to the specified row and column position. If row is 0, then row will
not be changed, and if column is 0, then column will not be changed.
Cursor Column E7 “$A5,<dh>,<dl>,3,’E7’, <column>” (7 bytes) – sends cursor to specified column.
Cursor Row
Return
E8 “$A5,<dh>,<dl>,3,’E8’, <row>” (7 bytes) – sends cursor to specified row.
EB “$A5,<dh>,<dl>,2,’EB’ ” (6 bytes)
Moves cursor down to the first column of the next row.
Clear All
EA “$A5,<dh>,<dl>,2,’EA’ ” (6 bytes)
Clears display, sends cursor to column 1, row 1.
Clear to End
Clear Line
DC “$A5,<dh>,<dl>,2,’DC’ ” (6 bytes)
Clear on-screen display from cursor to end of screen, position stays the same.
DB “$A5,<dh>,<dl>,2,’DB’ ” (6 bytes)
Clear on-screen display from cursor to end of line, cursor position stays the same.
Clear Spaces
Text Timeout
E9 “$A5,<dh>,<dl>,3,’E9’, <num spaces>” (7 bytes)
Clears specified number of spaces, starting from cursor to the right.
DQ “$A5,<dh>,<dl>,3,’DQ’, <time>” (7 bytes)
Sets screen timeout to specified time in seconds (1-254). If time is 0 or 255, any text
on the screen will persist indefinitely, or until cleared.
Contemporary Research Corporation
12
IR TV Controller
RS-232 Responses
iC-Net devices will send a response over the network whenever there is there is a change in status or command
from an IR remote or front panel.
Response String Structure
Characters in response strings are expressed in a combination of hex and ASCII characters. For clarity, the
following protocol examples use the following conventions:
•
•
•
•
•
•
ASCII characters or strings are shown enclosed in single quotes
Numbers shown that are not in single quotes are a single decimal byte
Parameters shown in < > brackets are single byte
A series of multiple commands or parameters are set apart by [ ] brackets
Commas separate the bytes, but are not part of the protocol
Double quotes enclose the command string, but are not part of the protocol
Command format:
“ ‘<’,<dh>,<dl>,<nrb>,<rb1>, <para1> [<rbN>]"
‘>’
<dh>
<dl>
<nrb>
<rb1>
<para1>
[<rbN>]
Starts the response
The zone or high order byte of the device
The unit or low order byte of the device (0 for global zone)
The number of response bytes to follow
The first response byte
Associated parameters, if any
Multiple responses may be included
Response
Description
New Channel T
“ ‘<’,<dh>,<dl>,2,'T',<new channel>" (6 bytes)
Sent in response to T? command.
IR Function
F
“ ‘<’,<dh>,<dl>,2,'F',<IR Function>" (6 bytes)
Sent when unit receives a new function command is pressed (1-8) or released (0) from
the IR remote.
0 = Release
1 = Play
2 = Stop
3 = Pause
4 = Fast Forward
5 = Rewind
8 = Record
Contemporary Research Corporation
13
IR TV Controller
Response
IR Key
Description
“ ‘<’,<dh>,<dl>,2,'K',<IR Key>" (6 bytes)
K
Sent when unit receives a new key command is pressed (10-116) or released (0) from
the IR remote.
0 = Release
10 - 19 = Numeric keypad entry 0 – 9
21 = Enter
22 = Channel Up
23 = Channel Down
29 = Menu
105 = Media Menu
106 = Cursor Right
107 = Cursor Left
108 = Cursor Up
109 = Cursor Down
110 = Media Select
116 = Timer
101 = Previous Channel
The 0 – 9, Channel Up/Down functions are sent only if enabled in the TM command
(Bit 2 = 1). The Channel Up/Down responses will be sent if the Tune Ring contains no
channels – see Ex2 in the Tune Ring command section.
IR Menu
M
“ ‘<’,<dh>,<dl>,5,'M',<msh>, <msl>, <mph>, <mpl>" (9 bytes)
Sent when IRC receives a new Menu command is pressed or released (0) from the IR
remote. Menu Selection high and low bytes are in <msh> and <msl>. Menu Parameter
high and low bytes are in <mph> and <mpl>.
A Menu command is initiated by pressing the Menu key, followed by a numeric entry,
then the Enter or Channel Up key. During the Menu process, the Channel Down key
acts as a backspace or delete key.
Some selections that need only a single numeric entry and will have a parameter value
of zero (0). Those keys are 0, 8, 9, 18, 20, 30, 900, 911, and 912.
Menu selections that will prompt the user to enter a second parameter entry are:
1 = Select Media
2 = Password
3 = Chapter Search
4 = Frame Search
11 = Channel
21 = Page Zone
22 = Page Room
25 = Go
21 = Attach Zone
32 = Attach Room
Tip: The Menu entries are active even if the TV power is off.
Device
SP " '<',0,0,4,'SP',<number devices present>,<number devices expected> (8 bytes)
Response
Sent in response to HE status query.
Tip: If the number of present and expected devices match, the green Net LED on the
HE will blink once per second. If the two numbers do not agree, the LED blinks
twice per second.
Contemporary Research Corporation
14
IR TV Controller
iC-Net Zones
To simplify controlling groups of devices, iC-Net is divided into 16 zones of 255 devices. All the
devices within each zone can be controlled simultaneously by sending a command to a single “virtual
device number”.
For example, noting the zone chart below, if we send a Power On command to device #256, any TV
controller numbered between 257 and 511 will instantly turn on. If we send a Power Off command to
device #4095, all devices in the system will turn off.
This is an immensely powerful feature, because most systems can only address one device at time. So
if you need to turn off all 50 TV in a zone, you would need to send 50 commands. In addition to the
hassles of creating multiple commands, there would be a long delay between the first and last
command. One command, instant response is easier.
As we noted before, ABC Media Retrieval Systems reserve Zone 0 for devices used in the central
control system, 1 -15 for iC-Net devices. This structure may be useful for your application, or you
could use Zone 0 just like any other iC-Net zone.
Zone
First Device Last Device Virtual Device
0
1
1
257
255
511
0
256
2
513
767
512
3
4
5
6
7
8
9
10
11
12
13
14
15
769
1023
1279
1535
1791
2047
2303
2559
2815
3071
3327
3583
3839
4000
768
1025
1281
1537
1793
2049
2305
2561
2817
3073
3329
3585
3841
1024
1280
1536
1792
2048
2304
2560
2816
3072
3328
3584
3840
4095
All Zones
Tip: You've probably figured out that you never want to assign a virtual device number to an
actual device in the system. If you assigned #1536 to a device, all the TV controllers in Zone
6 would respond every time you sent a command to that one device.
Contemporary Research Corporation
15
IR TV Controller
System Map
One of the key tasks for iC-Net integrators is to create a logical System Map, assigning device
numbers to TV controllers so they fall into logical zones. The device mapping could be sorted by type
or location; whichever suits the application.
iC-Net Zone
Zone
Room
Device
256
257
258
259
260
512
513
514
515
516
768
769
770
771
1
W 1st Floor
W151
W152
W153
W154
2
3
4
5
W 2nd Floor
E 1st Floor
W251
W252
W253
W254
E151
E152
E153
E154
772
E 2nd Floor
Coffee Areas
1024
1025
1024
1025
1026
1280
1281
1282
1283
1536
1537
1538
1792
1793
1794
1795
1796
2048
2049
2050
4095
E251
E252
E253
E254
G100
G150
G151
6
7
Day Care
Hallways
TV 1
TV 2
W1
W2
E1
E2
8
Office
All
Admin
A/V Center
All Zones
Contemporary Research Corporation
16
IR TV Controller
Typical RF and ICC-Net Signal Flow
The diagram below shows the structure of a typical Contemporary Research media retrieval system.
One of the key aspects for iCC-Net communication is to provide a forward and return (sub-channel)
path for data.
Contemporary Research Corporation
17
IR TV Controller
iCW-Net Wiring
Use Category 3 or Category 5 wire, 4 pair, unshielded, 24 AWG.
The iCC-HE and iCW-HE Head-End Network Controllers include three iCW-Net ports for
twisted-pair wired networking. Control wiring can be home-run to ports or run in a star format, using
punch-down blocks or RJ-45 “harmonicas” to distribute signals to multiple iCW-Net devices. Open
wiring runs do not need termination.
Head-End
iCW-Net #1
Screw Terminals
Punch-down Blocks
RJ-45 Harmonicas
Wall Plates
iCW-IRC
iCW-Net
RJ-45
6
5
4
3
2
1
PWR+
RXD+
RXD-
TXD+
TXD-
GND
BRN/WHT
WHT/BRN
GRN/WHT
WHT/BLU
BLU/WHT
WHT/GRN
ORG/WHT
WHT/ORG
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
8 TXD+
7 TXD-
6 GND
5 RXD+
4 RXD-
3 NC
2 NC
1 NC
iCW-Net #2, #3
RJ-45
BRN/WHT
WHT/BRN
GRN/WHT
WHT/BLU
BLU/WHT
WHT/GRN
ORG/WHT
WHT/ORG
RXD+
RXD-
GND
TXD+
TXD-
NC
TXD+
8
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
TXD-
7
GND
6
RXD+
5
RXD-
4
NC
3
NC
NC
NC
2
NC
1
Contemporary Research Corporation
18
IR TV Controller
Mounting the IRC
In most cases, you’ll mount the IRC directly to the TV, either below or above. Mounting below the TV
is preferred, as it’s usually the best location for IR reception from remotes, and helps to screen the
internal IR sensors from stray ceiling-fixture IR.
Installers commonly use Velcro to secure the IRC to the TV. Others will use brackets, such as our
optional RK2 Brackets to mount the IRC to the TV, as shown below. Some combine the two
approaches, using Velcro during the initial phase of installation, then securing with brackets when
testing and troubleshooting is completed.
In all cases, it’s best to mount the IRC near to the TV, monitor or video projector, simplifying wiring
for A/V and control cables. If, for some reason, the IRC must be mounted in an equipment rack, you’ll
need an optional RK1 Rack Mount Kit. In addition, order the IRC with the external IR In input (a
factory-installed option) and an optional IR-RX External IR Receiver.
Contemporary Research Corporation
19
IR TV Controller
Safety Instructions
Read before operating equipment.
1. Cleaning - Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol
cleaners. Use a damp cloth for cleaning.
2. Power Sources - Use supplied or equivalent UL/CSA approved low voltage DC plug-in transformer.
3. Outdoor Antenna Grounding - If you connect an outside antenna or cable system to the product, be
sure the antenna or cable system is grounded so as to provide some protection against voltage surges
and built-up static charges. Section 810 of the National Electrical Code, ANSI/NFPA No. 70, provides
information with respect to proper grounding of the mast and supporting structure, grounding of the
lead-in wire to an antenna discharge unit, size of grounding conductors, location of antenna discharge
unit, connection to grounding electrodes, and requirements for the grounding electrode.
4. Lightning - Avoid installation or reconfiguration of wiring during lightning activity.
5. Power Lines - Do not locate an outside antenna system near overhead power lines or other electric light
or power circuits or where it can fall into such power lines or circuits. When installing an outside antenna
system, refrain from touching such power lines or circuits, as contact with them might be fatal.
6. Overloading - Do not overload wall outlets and extension cords as this can result in a risk of fire or
electric shock.
7. Object and Liquid Entry - Never push objects of any kind into this product through openings as they
may touch dangerous voltage points or short out parts, resulting in a fire or electric shock. Never spill
liquid of any kind on the product.
8. Servicing - Do not attempt to service this product yourself as opening or removing covers may expose
you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel.
9. Damage Requiring Service - Unplug this product from the wall outlet and refer servicing to qualified
service personnel under the following conditions:
•
•
•
•
When the power supply cord or plug is damaged.
If liquid spills or objects fall into the product.
If the product is exposed to rain or water.
If the product does not operate normally by following the operating instructions. Adjust only those
controls that are covered by the operating instructions. An improper adjustment of other controls may
result in damage and will often require extensive work by a qualified technician to restore the product
to its normal operation.
•
•
If the video product is dropped or the cabinet is damaged.
When the video product exhibits a distinct change in performance, this indicates a need for service.
* Note to CATV system installer: This reminder is provided to call CATV system installer's attention to
Article 820-40 of the National Electrical Code (Section 54 of Canadian Electrical Code, Part I), that provides
guidelines for proper grounding and, in particular, specifies that the cable ground shall be connected to the
grounding system of the building as close to the point of cable entry as possible.
Contemporary Research Corporation
20
IR TV Controller
Limited Warranty and Disclaimer
Contemporary Research Corporation (CR) warrants this product to be free from defects in
material and workmanship under normal use for a period of two years from the date of
purchase from CR. Should such a defect occur CR will repair or replace, at their option, the
defective product at no cost for parts or labor.
This warranty extends to product purchased directly from CR or an Authorized CR Dealer.
Consumers should inquire from selling dealer as to the nature and extent of the dealer's
warranty, if any.
All warranty claims must be shipped pre-paid to the factory. Call or fax to obtain a Return
Material Authorization (RMA) number.
CR is not liable for any damages caused by any of its products or for the failure of any
products to perform, including any lost profits, lost savings, incidental damages, or
consequential damages. CR is not responsible for any claim made by a third party or made
for you by a third party. This limitation of liability applies whether damages are sought, or a
claim is made, under this warranty or as a tort claim (including negligence and strict product
liability), a contract claim, or any other claim. This limitation of liability cannot be waived or
amended by any person. This limitation of liability will be effective even if CR or an
authorized representative of CR has been advised of the possibility of any such damages.
Some states do not allow a limitation of how long an implied warranty lasts. Some states do
not allow the limitation or exclusion of incidental or consequential damages for consumer
products. In such states, the limitation or exclusion of the Limited Warranty may not apply to
you. This Limited Warranty gives you specific legal rights. You may also have other rights
that may vary from state to state. You are advised to consult applicable state laws for a full
determination of your rights.
Except as expressly set forth in this Limited Warranty, CR makes no other warranties,
expressed or implied, including any implied warranties of merchantability or fitness for a
particular purpose. CR expressly disclaims all warranties not stated in this Limited Warranty.
Any implied warranties that may be imposed by law are limited to the terms of this Limited
Warranty.
Contemporary Research Corporation
21
IR TV Controller
Contemporary Research Corporation
22
IR TV Controller
|