Installation Instructions
Sheet 1 of 5
Small, INDOOR
CPP/CPS
(Continuous Pendant)
Visor and Non-Visor
Warning: Before starting any work ensure
that all sources of power are turned off. All
work must meet local/national codes and be
performed by a certified electrician. Do not
mount fixtures vertically.
Vault w/ visor
C-Scroll w/ visor
Roundel w/ visor
These installation instructions are valid with the above Ametrix styles
Exploded view and part call-out
J-box
(by others)
Swivel pendant shown
Pendant tube
End pendant
assembly
Pendant tube
Center pendant
assembly
Pendant nut
(x2)
Power wire
from J-box
Yoke arm
10-32 x5/8"
End screw
#10-32 x 5/8"
End screw
(2x)
Fixture wire
#10-32 x 3/8"
Pan head screws
(2x)
Center cover plate
ADY071477 REV A (ECN080352)
Installation Instructions
Sheet 3 of 5
Small, INDOOR
CPP/CPS
(Continuous Pendant)
Visor and Non-Visor
Warning: Before starting any work ensure
that all sources of power are turned off. All
work must meet local/national codes and be
performed by a certified electrician. Do not
mount fixtures vertically.
Vault w/ visor
C-Scroll w/ visor
Roundel w/ visor
These installation instructions are valid with the above Ametrix styles
Center dimensions for PP and PS mounting assemblies
2ft fixture
7
28
"
8
733.40
3ft fixture
25
32
1036.22
40
"
4ft fixture
7
52
"
8
1343
PS (Pendant Swivel) mounting plate dimensions
3
"
4
19.05
15
32
36.95
15
16
49.43
31
32
49.92
1
"
1
"
1
"
3
16
4.86
"
1
5
"
19
32
14.99
7
32
127.84
R
"
2
"
16
62.08
PP (Pendant) mounting plate dimensions
1"
25.40
1
"
5
16
8.25
"
8
3.30
1
1
"
32
25.91
5
4
"
1
"
3
32
2
"
2
12.70
32
52.84
105.71
ADY071477 REV A (ECN080352)
Installation Instructions
Sheet 4 of 5
Small, INDOOR
CPP/CPS
(Continuous Pendant)
Visor and Non-Visor
Warning: Before starting any work ensure
that all sources of power are turned off. All
work must meet local/national codes and be
performed by a certified electrician. Do not
mount fixtures vertically.
Vault w/ visor
These installation instructions are valid with the above Ametrix styles.
C-Scroll w/ visor
Roundel w/ visor
Securing first fixture to wired center yoke
bracket
Securing first fixture to first pendant
3
4
Power wire
from J-box
Fixture wire
Fixture wire
Canopy
First fixture
head
#10-32 x 5/8
End screw
#6-32 x 3/8"
Pan head screws
#10-32 x5/8
End screw
Center cover
plate
1.
2.
3.
Remove both #6-32 x3/8" Pan head screws and slide center
cover plate down.
Run power wire from fixture through hub and into center
yoke bracket.
Secure first fixture to center yoke bracket using #10-32 x5/8"
end screw.
1.
2.
5
Choose first fixture in run. First fixture depends on length of
run, refer to page four(4) for fixture identification. The final
fixture will have to have the extra wire capped off.
Secure fixture head to pendant assembly using
#10-32x 5/8" end screw.
Securing additional fixtures in run
Wiring fixtures to J-box
6
Power wire
from J-box
Fixture wire
#10-32 x 5/8"
End screw
Fixture wire
Fixture wire
Center cover
plate
Center cover plate
1.
Mount next center or end pendant depending on length of
run.
Run new fixture wire into center yoke bracket.
Using #10-32 x5/8" end screws, secure new fixture head to
both pendants.
1.
2.
Attach wires and ensure connections are properly matched.
(wire nuts by others)
Replace center cover plate and secure using both #6-32 x
3/8" Pan head screws.
2.
3.
ADY071477 REV A (ECN080352)
Installation Instructions
Sheet 5 of 5
Small, INDOOR
CPP/CPS
(Continuous Pendant)
Visor and Non-Visor
Warning: Before starting any work ensure
that all sources of power are turned off. All
work must meet local/national codes and be
performed by a certified electrician. Do not
mount fixtures vertically.
Vault w/ visor
C-Scroll w/ visor
Roundel w/ visor
These installation instructions are valid with the above Ametrix styles
Continuous Pendant Row Layouts
Actual
Actual
Overall
Overall
Nominal Row
Nominal Row
Row
Length
(ft)
Length:
Row
Length
(ft)
Length:
Pendant Row Breakdown/ Installation
Pendant Row Breakdown/
(ft)
Installation Sequence
2C
(ft)
Sequence
2.6
3.6
25.4
27.4
28.9
29.9
30.9
31.9
31.9
32.5
34.5
35.5
36.5
38.0
39.0
39.0
40.0
41.0
42.6
43.6
44.6
45.6
46.1
47.1
48.1
49.1
3C,4C,4C,4C,4C,3C
3
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
3C
4C,4C,4C,4C,4C,4C
4
4.6
4C
4C,4C,3C,3C,3C,4C,4C
5
5.1
2C,2C
3C,4C,4C,4C,4C,4C,3C
6
6.1
2C,3C
4C,4C,4C,3C,4C,4C,4C
7
7.1
3C,3C
4C,4C,4C,4C,4C,4C,4C
8
8.1
3C,4C
4C,4C,4C,4C,4C,4C,4C
9
9.1
4C,4C
2C,4C,4C,4C,4C,4C,4C,2C
3C,4C,4C,4C,4C,4C,4C,3C
4C,4C,4C,4C,3C,4C,4C,4C
4C,4C,4C,4C,4C,4C,4C,4C
4C,4C,4C,3C,3C,3C,4C,4C,4C
3C,4C,4C,4C,4C,4C,4C,4C,3C
3C,4C,4C,4C,4C,4C,4C,4C,3C
4C,4C,4C,4C,3C,4C,4C,4C,4C
4C,4C,4C,4C,4C,4C,4C,4C,4C
4C,4C,4C,4C,3C,3C,3C,4C,4C,4C
3C,4C,4C,4C,4C,4C,4C,4C,4C,3C
4C,4C,4C,4C,4C,3C,4C,4C,4C
4C,4C,4C,4C,4C,4C,4C,4C,4C,4C
3C,3C,4C,4C,4C,4C,4C,4C,4C,3C,3C
4C,4C,4C,4C,3C,3C,3C,4C,4C,4C,4C
3C,4C,4C,4C,4C,4C,4C,4C,4C,4C,3C
4C,4C,4C,4C,4C,3C,4C,4C,4C,4C,4C
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
10.7
11.7
12.7
13.7
14.2
15.2
16.2
17.2
18.2
19.8
20.8
21.8
21.8
23.4
23.4
25.4
3C,3C,3C
4C,2C,4C
4C,3C,4C
4C,4C,4C
3C,3C,3C,3C
3C,3C,3C,4C
3C,4C,4C,3C
4C,4C,4C,3C
4C,4C,4C,4C
4C,3C,3C,3C,4C
3C,4C,4C,4C,3C
4C,4C,3C,4C,4C
4C,4C,3C,4C,4C
2C,4C,4C,4C,4C,2C
2C,4C,4C,4C,4C,2C
3C,4C,4C,4C,4C,3C
(Custom row configurations are available however pricing may be affected)