DYO, DYOV
Document # PG01-011
Revised 09/23/13 Page 1/2
PLANNING
GUIDE
™
Discovery iQ 30” Wide
Single Wall Ovens
Product tolerances: ±1/16” (±1.6 mm), unless otherwise stated.
wARninG
Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
1 1/8”
(2.9 cm)
1 1/8”
(2.9 cm)
•
•
3 1/2”
(8.9 cm)
3 3/16”
(8.1 cm)
This appliance must be installed in accordance with the
accompanying installation instructions.
Dedicated Circuit
Required
Total
Connected Load**
240 Vac, 4-wire*,
60Hz, 30 Amp.
240 Vac 60 Hz,
22.5 Amp. 5.4 kW
* Two 120 Vac hot (L1 and L2), one neutral,
one ground.
** This specification is for reference only. See
the product data label for exact specifications.
NSIONS - SIDE VIEW
Top of
chassis
B
Utility
F
cutout
G
H
C
D
A
Conduit:
60” (152 cm)
long
Control panel
front
Top of
E
chassis
Control panel
side view
A
B
C
D
E
F
G
H
J
K
29 7/8”
28 1/4”
28 3/4”
27 7/16”
1 5/16”
6 1/2”
5”
7 7/8”
1 3/8”
23 1/2”
(75.9 cm)
(71.8 cm)
(73.0 cm) (69.7 cm)
(3.3 cm)
(16.5 cm)
(12.7 cm)
(20.0 cm)
(3.5 cm) (59.7 cm)
PRODUCT DIMENSIONS
All specifications subject to change without notice.
Phone: (800) 793-0093
|