Installation & Operating Instructions
Base Unit Fan Heater
Model: BFH24T, BFH24TB & BFH24TS
IMPORTANT: These instructions should be read and carefully retained by the user.
Safety Warnings
08/17171/7 Issue 7 APR ‘05
•
•
•
•
•
•
•
DO NOT COVER OR OBSTRUCT the air inlet or outlet grille.
ENSURE THE APPLIANCE IS EARTHED.
Do Not place heater immediately below a socket outlet.
If the appliance is covered, there is a risk of fire.
Do not use this heater with young children unattended.
Do not use this heater in areas where excessive dust exists.
Do not touch or obstruct the grille areas when the heater is in operation.
Introduction
This heater has been designed for fitting in the space behind the plinth of floor standing kitchen units or other fitted furniture
units. It is recommended that the heater is not installed under cupboards used for storing perishable goods. It can be
accommodated in plinths with a minimum height of 12Omm, and is suitable for cupboards of 500mm width and above.
Installation
The installation of this appliance should be carried out by a competent electrician and be in accordance with the current IEE
wiring regulations.
Before undertaking installation work, ensure the electricity supply is disconnected from any relevant fixed wiring.
The heater is more easily fitted during the installation of new furniture units, or on existing furniture units if they can be
temporarily moved from their position against the wall. If an existing furniture unit cannot be moved, then it may be
necessary to remove the back of the unit in order to gain access to carry out the wiring installation.
Before installing the unit consider the location with respect to the following;
•
•
The electrical supply and cable length.
Position heater to deliver heat effectively without causing personal discomfort from overheating while standing at
work surfaces etc.
•
Minimum plinth height of 120mm and minimum furniture unit width of 500mm.
Procedure
1. Cutting the aperture in the Plinth
Cut aperture in furniture unit plinth to dimensions
shown.
This must be positioned so that the
minimum distance from the bottom of the aperture
to the TOP surface of any floor covering is not
less than 12mm and not more than 25mm.
If an overhang above the heater is greater than
75mm, then a distance of at least 100mm must
be maintained between the overhang and the
uppermost part of the heater.
Note: If fitted in corner with adjacent cupboards
to left hand side of heater then a distance of at
least 150mm must be maintained between the left
hand end of the heater and the front of the
adjacent cupboard door.
* This dimension must be maintained above the
top surface of any floor covering material. All
dimensions in millimetres.
Cleaning & User Maintenance
WARNING: DISCONNECT SUPPLY before carrying out maintenance.
General Cleaning
External appearance can be maintained by
wiping occasionally with a damp cloth; for stain
removal, a weak soap solution can be applied,
then wipe dry.
Internal Cleaning & Maintenance
To help prevent the build up of dust and fluff in the
heater it is advisable to apply the soft brush
attachment of a vacuum cleaner to the grille
occasionally (fig. 1).
From time to time it may be necessary to remove the
heater from the furniture unit so that the interior of
the heater and the heater compartment can be
cleared of any accumulated dust or fluff by means of
a vacuum cleaner (fig. 2).
To remove, unscrew the six fixing screws and
withdraw the appliance from the plinth.
To gain access to the inside of the appliance remove
the screws securing the top cover.
Clean the interior of the heater using the soft brush
attachment of a vacuum cleaner, taking care not to
damage the fan.
Refit the top cover. The interior compartment of the
furniture unit should also be cleared of dust and fluff
using the vacuum cleaner nozzle (fig. 3).
Remount the heater in the plinth ensuring the rear
support bracket is still adjusted correctly.
The electricity supply to the heater can now be
switched back on.
Safety – overheat protection
For your safety, this appliance is fitted with a thermal cut-out. In the event that the product overheats, the cut-out switches
the heater off automatically. To bring the heater back into operation, remove the cause of overheating, then turn off the
electrical supply to the heater for a few minutes. When the heater has cooled sufficiently reconnect and switch on the
heater.
If the cut-out operates repeatedly, contact your supplier
Procedure for resetting the cut-out;
A.
B.
Disconnect the electricity supply to the appliance either by switching off at the isolating switch panel.
Determine what has caused the cut-out to operate and rectify.
(Note : This should only be undertaken by competent persons with experience of repairing electrical appliances
and in full knowledge of the possible hazards involved ).
C.
After a short time delay to allow the appliance to cool down, all that is required to return the heater to normal
operation is to switch the electricity supply back on.
Circuit Diagram
After Sales Service
Your Dimplex base unit fan heater is guaranteed for two years from date of purchase. We undertake to exchange or
repair free of charge within this period any part found to be defective due to a manufacturing fault. This guarantee in no
way prejudices your rights under common law.
Should you require after sales service, please get in touch with the supplier through whom you purchased the appliance,
or your nearest service agent.
Please do not initially return a faulty appliance or part of an appliance to us as this may result in transit damage and / or
delay in providing service. Let us know your difficulty, quoting the model number and series letter of the appliance. We
will then take the appropriate action.
This product complies with the European Safety Standard EN60335-2-30 and the European Standard for Electromagnetic Compatibility
(EMC) EN55014, EN60555-2 and EN60555-3 which cover the essential requirements of EEC Directives 89/336.
Glen Dimplex UK Limited
Millbrook House
Grange Drive
UK customer help line (8.00AM – 6.00PM Mon-Fri; 8.30AM-1.00PM Sat)
Customer Services: Tel.
Fax.
0870 7270101
0870 7270102
Hedge End
Southampton
Hampshire SO30 2DF
Republic of Ireland
01 8424833
[c] Glen Dimplex UK Limited
All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex UK Limited.
|