Dimplex Fan CFP120 User Manual

CFP60, CFP90 & CFP120  
Industrial Fan Heater  
08/19588/0 (UK)  
Issue 0  
The product complies with the European Safety Standards EN60335-2-30 and the European Standard Electromagnetic Compatibility (EMC)  
EN55014, EN60555-2 and EN60555-3 which cover the essential requirements of EEC Directives 73/23 and 89/336  
 
Dimplex Industrial Fan Heater  
Models : CFP60, CFP90 & CFP120  
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE  
Electrical  
IMPORTANT SAFETYADVICE  
Model  
Heat  
Electrical  
Supply  
Electrical  
Load  
Required Supply Weight  
DO NOT COVER OR OBSTRUCT the air inlet or outlet grille.  
Output  
Plug  
Cable  
IMPORTANT – Disconnect from the mains supply before  
carrying out maintenance work.  
(per phase)  
Amps  
kW  
Amps  
16  
5G x  
kg  
THIS HEATER MUST BE EARTHED  
CFP60  
CFP90  
3 / 6  
380-415V ~3PN  
220-240V ~3P *  
380-415V ~3PN  
220-240V ~3P *  
9.0  
15.6  
13.3  
23.0  
17.5  
30.4  
1.5mm² 15.0  
2.5mm² 16.0  
4.0mm² 16.0  
Keep combustible materials such as drapes and other  
furnishings clear from the front, sides and rear of the heater.  
16  
6 / 9  
16  
The heater should always be used upright on a flat, stable  
surface.  
32  
CFP120 6 / 12 380-415V ~3PN  
220-240V ~3P *  
32  
DO NOT use this heater in the immediate surrounding of a  
bath, a shower or a swimming pool.  
32  
DO NOT use this heater in areas where excessive dust exists.  
The 5 Pin Plug supplied with this heater suits 380-415V ~3PN Star  
electrical supply. If 220-240V ~3P Delta supply is to be used a 4 Pin Plug  
is required (as denoted by * above).  
DO NOT store or use any flammable materials or sprays in  
the vicinity of the heater – FIRE HAZARD.  
The Supply Cable is specifically chosen for each CFP heater and should  
only be replaced by a similar cable supplied by the manufacturer.  
DO NOT insert any foreign objects into the heaters openings.  
Risk of injury, electric shock or damage to the heater may  
occur.  
See Fig. 4 for CFP Wiring Diagram. (References are listed below)  
DO NOT use the heater on deep pile carpets or the long hair  
type of rugs.  
A
B
C
D
E
F
G
H
I
- Heat 1 Contactor  
- Heat 2 Contactor  
- Thermal Safety Cut-out Circuit  
- Star / Delta Connector Blocks  
- Heating Elements  
- Mains Lead & Plug  
- Earth  
- Heat / Fan Selection Switch  
- Thermostat  
- Tilt Switch  
DO NOT operate the heater with wet hands.  
DO NOT use heater to dry your laundry.  
DO NOT operate the heater with the mains lead overhanging  
the front outlet grille.  
This heater is not intended for use by children or other  
persons without assistance or supervision if their physical,  
sensory or mental capabilities prevent them from using it  
safely. Children should be supervised to ensure that they do  
not play with the heater.  
T
TB - Main In Terminal Block  
- Motor  
M
The heater carries the Warning symbol  
must not be covered.  
indicating that it  
Electrical connection  
This heater must only be connected to a three phase supply. The supply  
voltage must correspond to the voltage shown on the heaters rating  
label.  
IMPORTANT : The wires in this mains lead are coloured in accordance  
with the following code :  
The socket-outlet must be accessible at all times to enable  
the mains plug to be disconnected as quickly as possible.  
The instruction leaflet belongs to the heater and must be  
kept in a safe place. If changing owners, the leaflet must be  
surrendered to the new owner.  
BROWN  
-
-
-
-
-
LIVE (L1)  
LIVE (L2)  
LIVE (L3)  
NEUTRAL  
EARTH  
IMPORTANT – If the mains lead of this heater is damaged, it  
must be replaced by the manufacturer or its service agent  
or a similarly qualified person in order to avoid a hazard.  
BLACK  
GREY  
Ensure proper manual handling procedures are observed at  
all times.  
BLUE  
GREEN & YELLOW  
CAUTION – In order to avoid a hazard due to inadvertent  
resetting of the thermal cut-out, this heater MUST NOT be  
supplied through an external switching device, such as a  
timer, or connected to a circuit that is regularly switched on  
and off by the utility.  
Note : L’ or ‘N’ must not be connected to the EARTH terminal marked ‘E’  
or or coloured GREEN or GREEN AND YELLOW.  
If in doubt, consult your electrician.  
Star / Delta Voltage Systems  
The heater is wired to accept 380-415V ~3PN (see Fig. 5b).  
To change to a 220-240V ~3P system (see Fig. 5a) the following steps  
should be carried out :  
General  
The industrial fan heater is a robust, durable portable heater designed to  
coordinate with the Dimplex range ofAir Curtains, providing environmental  
heating in commercial and light industrial environments.  
1. Swap the plug on the end of the Mains In lead to a 4 Pin plug (refer  
to * in table above for plug loading).  
BROWN  
BLACK  
GREY  
: LIVE (L1)  
: LIVE (L2)  
: LIVE (L3)  
A heat selector switch and thermostat gives a wide range of control.  
Some of the heater’s features are highlighted in Fig. 2.  
(a) Thermostat / Heat control housing.  
(b) Robust tubular frame for carrying the heater.  
(c) Metal air outlet grille.  
BLUE  
: Insulate exposed core and place  
inside plug housing.  
: EARTH  
GREEN & YELLOW  
2. Remove the control moulding and top panel.  
3. Change over the links on the Star / Delta Terminal Block to resemble  
Fig. 5a.  
(d) 2m long supply cable.  
(e) Impact resistant end mouldings.  
4. Remove the blue neutral wire from ‘N’ and connect into ‘L3’ in the  
Mains In Terminal block.  
5. Replace the control moulding and top panel.  
Attention: If using an extension cable, ensure that it complies with local  
electrical regulations and is suitable for the loads shown above.  
 
To reset the cut-out follow the procedures below :  
Operation  
1. Disconnect power supply.  
The heat output from this heater is regulated using the rotating wheels  
shown in Fig. 3. By rotating these wheels, with the unit plugged in,  
various fan and heat settings may be obtained.  
2. Determine what has caused the cut-out to operate and rectify.  
( Note : This should only be undertaken by competent persons  
with experience of repairing electrical appliances and in full  
knowledge of the possible hazards involved ).  
Function control wheel  
With the function control wheel, (f) in Fig. 3, the settings shown below  
may be obtained;  
3. After a short period of time, with the heater placed in a cool area,  
the cut-out will reactivate allowing electrical supply to be  
returned to the heater thus permitting normal operation.  
0
Off  
Fan only  
Maintenance  
1
2
Half Heat + Fan  
Full Heat + Fan  
Warning  
-
Disconnect the heater from the mains supply before  
carrying out maintenance.  
This product is designed to require no maintenance. If operated in an  
extremely dusty environment it may however be necessary to carefully  
brush clean the rear air-inlet grille from time to time.  
If the heater is to be placed in storage for long time intervals, Dampness  
may penetrate the heating elements and with reactivation, EARTH FAULT  
BREAKERS may trip. This is not a fault and can be rectified by feeding  
the heater using a source without an earth fault breaker until the elements  
have fully dried.  
Thermostat control wheel  
The thermostat control wheel, (g) in Fig. 3, will adjust the temperature  
cut off point of the heater.  
Low Temperature  
High Temperature  
Recycling  
Both heat and fan operation can be regulated by the thermostat.  
The thermostat, (g) in Fig. 3 enables a constant local ambient temperature  
to be maintained.  
Turn the thermostat towards the back of the heater to the maximum  
setting and allow the heater to operate until the room temperature has  
reached the desired level.  
For electrical products sold within the European  
Community.  
At the end of the electrical products useful life it should  
not be disposed of with household waste. Please  
recycle where facilities exist. Check with your Local  
Authority or retailer for recycling advice in your country.  
Then turn back the thermostat until it ‘just’ operates. Cycling of the  
thermostat will then occur to maintain this ambient temperature.  
Cleaning  
With the function switch in the  
1
or  
2
position, the heat is regulated by  
WARNING : ALWAYS DISCONNECT FROM THE POWER SUPPLY  
BEFORE CLEANING THE HEATER  
the thermostat, whilst the fan continues to operate.  
Do not use detergents, abrasive cleaning powders or polish of any kind  
on the heater.  
Installation  
The CFP range of heaters are designed for free-standing use.  
Wipe with a dry cloth to remove dust and a damp cloth (not wet) to clean  
off stains. Be careful not to allow moisture into the heater.  
Ensure that dust or fluff does not accumulate inside the heater as this  
could lead to overheating of the element. Use a vacuum cleaner to remove  
any fluff which does accumulate.  
CAUTION: DO NOT direct the air outlet grille, (c) in Fig. 2, towards the  
ground or wall (min 1m) when in the free-standing position.  
Safety in Use  
This appliance incorporates a number of safety devices. In addition to  
the safety precautions in the ‘Important Safety Advice’ section, your  
attention is drawn to the following;  
After Sales Service  
Your product is guaranteed for one year from the date of purchase.  
Within this period, we undertake to repair or exchange this product free  
of charge (excluding element & subject to availability) provided it has  
been installed and operated in accordance with these instructions.  
Tilt Switch  
The tilt switch will prevent the heater from working if it is accidentally  
tipped over or not standing upright. If this occurs, disconnect the power  
and stand the heater back upright on a flat, stable surface and allow it to  
cool. Reconnect the power and normal operation should be resumed.  
Your rights under this guarantee are additional to your statutory rights,  
which in turn are not affected by this guarantee.  
Should you require after sales service you should contact our customer  
services help desk on 0870 727 0101. It would assist us if you can  
quote the model number, series, date of purchase, and nature of the fault  
at the time of your call. The customer services help desk will also be able  
to advise you should you need to purchase any spares.  
If the heater does not operate, it is possible the thermal safety cut-out  
has activated – refer to reset procedure in ‘Thermal Safety Cut-outs’  
section.  
Thermal Safety Cut-outs  
Please do not return a faulty product to us in the first instance as this  
may result in loss or damage and delay in providing you with a satisfactory  
service.  
The power supply to the heater may also be interrupted if one or a  
combination of the following abnormal events occurs:  
1. Air inlet or outlet grilles are obstructed.  
Please retain your receipt as proof of purchase.  
2. Internal ventilation is impaired due to build up of dust and fluff.  
3. Fan failure.  
Glen Dimplex UK Limited  
Millbrook House  
Grange Drive  
UK customer help line (8.00AM – 6.00PM Mon-Fri; 8.30AM-1.00PM Sat)  
Customer Services:  
Tel.  
0870 7270101  
Fax.  
e-mail  
Tel.  
0870 7270102  
01 8424833  
Hedge End  
Southampton  
Hampshire. SO30 2DF  
Republic of Ireland  
[c] Glen Dimplex UK Limited  
All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex UK Limited.  
 

Coleman Tent 200001391 User Manual
Compaq Network Router OSI APLMGR D43 User Manual
Craftsman Battery Charger 24074290 User Manual
Crown Stereo Amplifier K0862 1 User Manual
Cuisinart Kitchen Utensil CTG 00 MAN User Manual
Cypress Computer Hardware CY14B104K User Manual
Dymo Sander 31 250 User Manual
Dynex Camcorder Accessories DX DA100501 User Manual
Faber Ventilation Hood Inca Pro 38 User Manual
Frigidaire Dishwasher 154889301 User Manual