MAINS POWERED 230V~  
Rechargeable Battery Back-Up  
Model Ei 164R Heat  
Remote control capability  
Easi-Fit base  
Tamper proof rechargeable lithium battery back up  
Fixed temperature fast response thermistor type  
sensor, range 54C to 62C  
Test/Hush button  
Advanced suppression and calibration technology  
Interconnectable to other Ei mains powered alarms  
Low power cell warning  
Kitemarked to BS5446-2:2003  
5 year guarantee  
Product Description  
Operation  
The Ei164R is a Heat Alarm that runs on 230V AC mains  
power, and has built in tamper proof rechargeable lithium  
cells that act as a battery back up in the event of mains  
failure. These rechargeable lithium cells are designed to  
have a ten year life and outlast the life of the heat alarm  
itself, whilst providing up to six months of heat alarm  
operation without mains power.  
The green indicator will illuminate to show mains  
power is present  
The red indicator will flash every 40 seconds to  
show that the detector has performed an automatic  
self test  
The red indicator will flash rapidly to show an alarm  
condition for the heat detector  
The Ei164R is supplied with the Easi-Fit base that allows  
very quick and simple installation of the heat alarm,  
combined with simple detector head removal and  
replacement. The Easi-Fit base automatically connects  
both mains power and battery as the detector head  
slides on to the Easi-Fit base.  
The “Test/Hush” button will either silence false  
alarms or perform a unit self test  
In “Test” mode the alarm will perform a self test and  
sound the horn  
The Ei164R allows the detector to be controlled remotely  
by either a “Test/Hush” Switch (Ei152) or a Manual Call  
Point (MCP400). If the Ei164R is also interconnected to  
other Ei mains powered alarms then the whole system  
will be controllable remotely.  
In “Hush” mode the alarm enters a ten minute period  
of reduced sensitivity to overcome false alarm  
conditions, and will then automatically reset itself  
When interconnected to other Ei mains powered  
alarms, an alarm on one detector will trigger all other  
interconnected alarms within one second (only the  
triggered alarm will flash a red indicator)  
The Ei164R has built in circuitry to aid suppression of  
voltage transients and RF interference to further reduce  
the chances of false alarms under such conditions.  
The heat detector will emit a beep every 40 seconds  
to indicate that the battery back up is depleted and  
needs recharging  
Heat alarms are ideal for use in kitchens and garages,  
where the use of optical or ionisation alarms would lead  
Shannon Free Zone, Shannon, Co. Clare, Ireland.  
Ph.+353 61 471277 Fx.+353 61 471053  
www.eielectronics.com  
 

EVGA Computer Hardware 121 BL E756 User Manual
Extron electronic Switch SW6 VGA A User Manual
Fender Cooktop CS 18 User Manual
Fisher Price Baby Toy V2758 User Manual
Fujitsu Printer 637DCL User Manual
GE Double Oven JB600 User Manual
GE Microwave Oven PNM1871SMSS User Manual
GE Oven ZSC1000 1001K User Manual
Gitzo Camcorder Accessories G1588 User Manual
Goodman Mfg Air Conditioner A GPG13 M User Manual