Securing screws
LAMP UNIT (LAMP/CAGE MODULE)
FOR PROJECTOR
3 Remove the lamp unit.
• Loosen the securing screws (two for each lamp)
from the lamp unit. Hold the lamp unit by the
handle and pull it in the direction of the arrow.
At this time, keep the lamp unit horizontal and
do not tilt it.
MODEL
AH-55001
INSTALLATION MANUAL
CAUTION:
Handle
4 Insert the new lamp unit.
• Potential hazard of glass particles if lamp ruptures. Please have an EIKI Authorized Dealer or Service Center
replace lamp if rupture occurs.
• Do not remove the lamp unit directly after operation of the projector.The lamp may be extremely hot.Wait at
least one hour after the power cord is disconnected to allow the surface of the lamp unit to fully cool before
removing the lamp unit.
• Fully insert the lamp unit into the lamp unit com-
partment. Press the handles back to their posi-
tions, and tighten the securing screws.
■
It is recommended that the lamp be replaced when the remaining lamp life becomes 5% or less, or when you notice a signifi-
cant deterioration in the picture and color quality.The lamp life (percentage) can be checked with the on-screen display.
5 Replace the lamp unit cover.
• Slide the lamp unit cover to the position where
the indicator “|” of the lamp cover unit and the
“\” of the projector will meet to close the cover.
Then tighten the user service screw to secure
the lamp unit cover.
Compartment
for
Lamp 2
Hg LAMP CONTAINS MERCURY For State Lamp Disposal Information
Compartment
for
Lamp 1
U.S.A. ONLY
AH-55001
STANDBY-ON button
Removing and Installing the
Lamp Unit
Info
• If the lamp unit and lamp unit cover are not cor-
rectly installed, the power will not turn on, even if
the power cord is connected to the projector.
Warning!
• Do not remove the lamp unit from the projector right
after use. The lamp and parts around the lamp will
be very hot and may cause burn or injury.
User service screw
Info
Resetting the Lamp Timer
• Make sure the lamp unit is removed using the
handle. Make sure the glass surface of the lamp
unit or the inside of the projector are not touched.
• To avoid injury to yourself and damage to the lamp,
make sure you carefully follow the steps below.
• Do not loosen other screws except for the lamp unit
cover and lamp unit.
Reset the lamp timer after replacing the lamp.
Info
• Make sure to reset the lamp timer only when re-
placing the lamp. If you reset the lamp timer and
continue to use the same lamp, this may cause the
lamp to become damaged or explode.
STANDBY-ON button
1 Press STANDBY-ON on the projec-
1 Connect the power cord.
Power cord
tor or on the remote control to put the
•
Plug the power cord into the AC socket of the projector.
ENTER button
projector into standby mode.
• Disconnect the power cord and unplug the
power cord from the AC socket after the cool-
ing fan stops.
• The cooling fan may continue to run for a while
even after the power cord is removed.
• Leave the lamp until it has fully cooled down
(about 1 hour).
\,", | buttons
2 Reset the lamp timer.
2
For Lamp 1
• When you reset the timer, while simultaneously
holding down \, " and ENTER, press
STANDBY-ON on the projector.
• “LAMP1 0000H” is displayed, indicating that the
lamp timer is reset.
2 Remove the lamp unit cover.
• Loosen the user service screw (1) that secures
the lamp unit cover.Remove the lamp unit cover
to slide it in the direction of the arrow (2).
1
For Lamp 2
User service screw
• When you reset the timer, while simultaneously
holding down |, " and ENTER, press
STANDBY-ON on the projector.
Power cord
• “LAMP2 0000H” is displayed, indicating that the
lamp timer is reset.
Printed in China
XXXXXXXXXXXXX
08PXX-CH-NM
|