Introduction
Introduction:
™
Thank you for purchasing the Elation DMX-Branch/4. To optimize the
performance of this product, please read these operating instructions
carefully to familiarize yourself with the basic operations of this unit.
™
The Elation® DMX-Branch/4 is DMX signal splitter/booster combina-
tion. This unit has been tested at the factory before being shipped to
you, there is no assembly required.
Customer Support:
Elation® provides a customer support line, to provide set up help and
to answer any question should you encounter problems during your
set up or initial operation. You may also visit us on the web at www.
elationlighting.com for any comments or suggestions.
CAUTION
RISK OF ELECTRICAL SHOCK
DISCONNECT INPUT POWER
BEFORE OPENING
WARNING: THIS APPARATUS MUST BE GROUNDED
DMX-BRANCHX4
POWER INPUT: 120V~60Hz
DMX BOOSTER
INTERNAL FUSE:
F100mA 250V 5x20mm (5 Pcs)
Service Hours are Monday through Friday 10:00 a.m. to 5:00 p.m.
Pacific Time.
1
2
1 = Ground
2 = Data-
3 = Data+
Voice:
Fax:
(323) 582-3322
(323) 582-3108
3
1
2
5
1 = Ground
2 = Data-
3 = Data+
4 = Not used
5 = Not used
E-mail:
120Ω
4
3
0V
Warning! To prevent or reduce the risk of electrical shock or fire, do
not expose this unit to rain or moisture.
DMX OUT
1
2
3
4
1
2
3
4
Caution! There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself, doing so will void your manufactures war-
ranty. In the unlikely event your unit may require service please contact
your nearest Elation dealer.
Protect our environment, do not discard this cartoon in the trash. Please
recycle when ever possible.
User Instructions
Elation Professional
4295 Charter Street
Los Angeles Ca. 90058
Rev. 12/04
DMX-Branch/4™ Set Up Cont.
DMX-Branch/4™ Set Up
Unpacking:
Notice: Be sure to follow figures two and three when making
your own cables. Do not use the ground lug on the XLR connec-
tor. Do not connect the cable’s shield conductor to the ground
lug or allow the shield conductor to come in contact with the
XLR’s outer casing. Grounding the shield could cause a short
circuit and erratic behavior.
EveryDMX-BranchX4™hasbeenthoroughlytestedandhasbeen
shipped in perfect operating order. Carefully check the shipping
carton for damage that may have occurred during shipping. If the
carton appears to be damaged, carefully inspect your fixture for
any damage. In the case damage has been found please contact
our toll free customer support number for further instructions.
XLR Pin Configuration:
XLR FEMALE SOCKET
COLD 2 EARTH
XLR MALE SOCKET
1 EARTH 2 COLD
1
Pin
1
=
Shield
Power Supply:
Before plugging your unit in be sure the source voltage in your
area matches the required voltage for your Elation® DMX Branch
Pin 2 = Data Compliment (negative)
Pin 3 = Data True (positive)
3 HOT
3 HOT
h X4™
X4.™ The Elation® DMX-Branc
is available in a 115v and
Figure 3
230v version. Because line voltage may vary from venue to venue,
you should be sure to plug your power supply into a matching
wall outlet before attempting to operate you controller.
Special Note: Line Termination.
When longer runs of cable are used, you may need to use a ter-
minator on the last unit to avoid erratic behavior. A terminator is a
90-120 ohm 1/4 watt resistor which is connected between pins 2
and 3 of a male XLR connector (DATA + and DATA -). This unit is
inserted in the female XLR connector of the last unit in your daisy
chain to terminate the line. Using a cable terminator will decrease
the possibilities of erratic behavior.
Data Cable (DMX Cable) Requirements:
Your fixture and your controller require a standard 3-pin XLR con-
nector for data input and data output (Figure 1). If you are making
your own cables be sure to use standard two
conductor shielded cable (This cable may be
purchased at almost all pro sound and light-
ing stores). Your cables should be made with
a male and female XLR connector on either
end of the cable. Also remember that DMX
cable must be daisy chained and can not be
“Y”ed or split.
Termination reduces signal errors and
1
avoids signal transmission problems
3
and interference. It is always advisable
2
to connect a DMX terminal, (Resistance
120 Ohm 1/4 W) between PIN 2 (DMX-)
and PIN 3 (DMX +) of the last fixture.
Figure 4
Linking:
Notice: Do not use the ground lug on the XLR connector. Do
not connect the cable’s shield conductor to the ground lug or
allow the shield conductor to come in contact with the XLR’s
outer casing. Grounding the shield could cause a short circuit
and erratic behavior.
The DMX Branch X4™ can be linked to another by using the
DMX OUT jack on the side of the unit. Be sure to only use the
output jack beside the input jack to link the DMX-Branch X4’s
together. When linking units together be sure the terminate selec-
tor switch is in the out position (Link Out), when you are not
using the output jack be sure the terminate switch is in the in
position (Terminate).
COMMON
1
2
1
2
DMX +
DMX -
Figure 2
DMX512 OUT
3-PIN XLR
DMX512 IN
3-PIN XLR
3
3
DMX-Branch/4™ Operation
Model:
SPECIFICATIONS:
DMX-Branch X4™
Be sure the power is disconnected before making any type of
connections Connect the output signal from your DMX control-
ler to the input jack of the DMX-Branch X4. Use the four output
channels to send DMX signal to your DMX fixtures. Dasiy-chain
the DMX output. Remember that the pack is only place a DMX
signal may be split. If you are not using the output jack to link
DMX-Branch X4’s together be sure the terminate switch is in the
in position (Terminate).
Power:
Fuse:
Working Position:
Weight:
Size:
110V/60Hz
5 x 100mA GMA (Internal)
Any
6.5 Lbs.
13” x 3 1/8” x 7 1/8”
None
Duty Cycle:
Indicators:
Each of the four output channels have a set LED indicators, a
red and a green. Without an incoming DMX signal the red LEDs
will function as a power indicator. When a DMX signal is applied
the LED’s will serve two functions:
1. These indicator will indicate pin polarity. A solid red LED will
indicate pin 3 is hot (positive). A solid green LED will indicate
pin 2 is hot (positive).
2. When shorted or bad cable is connected to a particular chan-
nel the LED will turn off. This is useful to immediately identify
bad cables or lines.