Estate Range TEP200VA User Manual

20" (50.8 cm) Freestanding Electric Range  
PRODUCT MODEL NUMBERS  
PRODUCT DIMENSIONS  
TEP200VA  
TEP222VA  
Electrical: If codes permit and a separate ground wire is  
used, it is recommended that a qualified electrical installer  
determine that the ground path is adequate and wire  
gauge is in accordance with local codes.  
Range Rating*  
Specified Rating of  
Power Supply Cord Kit  
and Circuit Protection  
120/240 Volts 120/208 Volts  
Amps  
D
A
8.0 - 16.5 KW 6.0 - 12.5 KW  
40 or 50**  
16.6 - 22.5 KW 12.6 - 18.5 KW 50  
*The NEC calculated load is less than the total  
connected load listed on the model/serial rating plate.  
**If connecting to a 50-amp circuit, use a 50-amp rated  
cord with kit. For 50-amp rated cord kits, use kits that  
specify use with a nominal 1-3/8" (34.9 mm) diameter  
connection opening.  
C
B
A circuit breaker is recommended.  
The range can be connected directly to the circuit breaker  
box (or fused disconnect) through flexible or nonmetallic  
sheathed, copper or aluminum cable.  
A. 36" (91.5 cm)  
B. 19½" (49.5 cm)  
C. 24½" (62.2 cm)  
D. 42" (106.7 cm)  
The model/serial rating plate is located under the left front  
burner bowl.  
CABINET OPENING DIMENSIONS  
Cabinet opening dimensions shown are for:  
B
25" (63.5 cm) countertop depth  
24" (61.0 cm) base cabinet depth  
36" (91.4 cm) countertop height  
F
C
D
IMPORTANT: If installing a range hood or microwave  
hood combination above the range, follow the range hood  
or microwave hood combination installation instructions  
for dimensional clearances above the cooktop surface.  
A
E
NOTE: 24" (61.0 cm) minimum when bottom of wood or  
metal cabinet is covered by not less than 1/4" (0.64 cm)  
flame retardant millboard covered with not less than No.  
28 MSG sheet steel, 0.015" (0.4 mm) stainless steel,  
0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.  
G
G
30" (76.2 cm) minimum clearance between the top of the  
cooking platform and the bottom of an uncovered wood  
or metal cabinet.  
H
To eliminate the risk of burns or fire by reaching over  
heated surface units, cabinet storage space located above  
the surface units should be avoided. If cabinet storage is  
to be provided, the risk can be reduced by installing a  
range hood that projects horizontally a minimum of 5"  
(12.7 cm) beyond the bottom of the cabinets.  
A. 18" (45.7 cm) min. clearance  
upper side cabinet to  
countertop  
E. 5" (12.7 cm) min. countertop  
space to side wall or other  
combustible material  
B. 13" (33.0 cm) max. upper  
cabinet depth  
F. For minimum clearance to top  
of cooktop, see NOTE.  
C. 20" (50.8 cm) min. cabinet  
opening width  
G. Wall receptacle - 8" (20.3 cm)  
from either cabinet,  
D. 20¹⁄₈" (51.1 cm) opening width  
H. 5½" (14.0 cm) max. from floor.  
Locate 120/240-volt  
receptacle in shaded area.  
Because Whirlpool Corporation policy includes a continuous commitment to improve our  
products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. W10175654B  
08-27-08  
 

Echo Bear Cat Chipper CH4540 73454 User Manual
Euphonix Music Mixer Series MC User Manual
Euro Pro Cordless Drill SB77H User Manual
Extron electronic Network Card HSA 222S User Manual
Fender Musical Instrument Amplifier B DEC 30 User Manual
Fluke Thermometer 1523 User Manual
Foundations Baby Furniture 100 EV User Manual
Fujitsu Switch MB3842 User Manual
GE Monogram Refrigerator ZISS360DXSS User Manual
Goodman Mfg Air Conditioner CKLB18 1 User Manual