TOWER COOLING FAN
WITH REMOTE CONTROL
MODEL: FH-777
Please read this instruction manual carefully before using the unit
12. Switch OFF and unplug the unit before cleaning and/ or any maintenance.
13. This unit has humidifying function. Please do not use it for a long time in an airtight place
(such as small closed room) to avoid too much humidity.
14. Change the water frequently to keep it clean.
15. This unit must be operated in a horizontal position/ flat surface.
16. This unit shall not be exposed to dripping or splashing water.
17. Do not install the unit in a confined space, such as a bookcase or built-in
cabinet.
18. DISPOSAL: Do not dispose this product as unsorted municipal waste.
Important Warnings:
1.
This unit should not be adjusted or repaired by anyone except authorized service agency.
2. If the unit tips over, please pull out plug from power outlet at once, then take the unit to
authorized service agency for check or repair.
Product Appearance and Operation
Figure1
3
Remote Control and Its Operations
1. Please operate the Remote Control
within 6 meters from the unit.
2. If the remote control does not
work in a short distance from
the unit, please open the battery cover with
a tool (such as a coin) and change the batteries.
3. Do not allow children to play with
the remote control.
Figure 2
Before Operation
1. Draw out the water tank and fill in with water before using this unit. Refer to the Figure 3,
Please DO NOT pour the water above 104oF into the water tank.
2. ICE and ICE BOX can be added into the base water tank (optional). Please refer to Figure 4
Figure 3
Figure 4
Note:
1) Do not put the ICE BOX into the water tank when the base water tank is full. Water may
overflow.
2) The ICE BOX should be frozen before using.
3) The ICE BOX is sealed by manufacturer.
4) Even thought the gel inside the ICE BOX is NOT harm to human, but do not try to open the
ICE BOX and put the gel directly in the water tank. The gel may damage the water pump and
the water running system.
4
General Operation (Please refer to the Figure 5)
Figure5
POWER button
1. Connect the plug to the power outlet, and a beep tone will be heard.
2. Press the POWER button, the FAN indicator and HIGH speed indicator will be turned on with a
beep tone. The default start up setting is of this unit is high fan speed at normal mode.
3. Press the POWER button again to turn the unit off.
MODE button
When the unit is ON, press the MODE button once and the NATURE mode is on. Press the
MODE button again to change to the SLEEP mode; press the MODE button for the 3rd time
and it will change to Normal mode again.
HIGH speed+ NATURE mode:
In NATURE mode, press the SPEED button to HIGH. Both HIGH and NATURE indicators
will be on. The wind speed will change automatically as follows:
-HIGH speed 5 sec. Æ LOW speed 5 sec. Æ MED speed 5 sec. Æ Stop 5 sec. Æ MED
speed 10 sec. Æ HIGH speed 10 sec. Æ MED speed 5 sec. Æ LOW speed 5 sec. Æ
Stop 5 sec. Æ MED speed 5 sec. Æ HIGH speed 5 sec. Æ LOW speed 5 sec. Æ Stop 5
sec. The unit will work continuously in this mode until the unit is power off.
MED speed + NATURE mode:
In NATURE mode, press the SPEED button to MED. Both MED and NATURE indicators will
be on. The wind speed will change automatically as follows:
-MED speed 5 sec. Æ LOW speed 5 sec. Æ MED speed 5 sec. Æ LOW 5 sec. Æ Stop
5 sec. Æ MED speed 10 sec. Æ LOW speed 10 sec. Æ MED speed 5 sec. Æ LOW 5
sec. Æ Stop 5 sec. Æ MED speed 5 sec. Æ LOW speed 5 sec. Æ Stop 5 sec. The unit
will work continuously in this mode until the unit is power off.
5
LOW speed + NATURE mode:
In NATURE mode, press the SPEED button to LOW. Both LOW and NATURE indicators will
be on. The wind speed will change automatically as follows:
-MED speed 5 sec. Æ LOW speed 15 sec. Æ MED speed 5 sec. Æ LOW 15 sec. Æ Stop
5 sec. Æ MED speed 5 sec. Æ LOW speed 10 sec. Æ MED speed 5 sec. Æ LOW 10
sec. Æ Stop 5 sec. Æ MED speed 5 sec. Æ LOW speed 20 sec. Æ Stop 5 sec. The unit
will work continuously in this mode until the unit is power off.
HIGH speed+ SLEEP mode:
In SLEEP mode, press the SPEED button to HIGH. Both HIGH and SLEEP indicators will be
on. The wind speed will change automatically as follows:
- First 0.5 hr: HIGH and MED speed wind alternate in every 10 sec
-Second 0.5 hr: MED speed wind
-After 1hr or until the unit is power off: LOW speed wind
MED speed + SLEEP mode:
In SLEEP mode, press the SPEED button to MED. Both MED and SLEEP indicators will
be on. The wind speed will change automatically as follows:
- First 0.5 hr: MED and LOW speed wind alternate in every 10 sec
-After 0.5 hr or until the unit is power off: LOW speed wind
LOW speed + SLEEP mode:
In SLEEP mode, press the SPEED button to LOW. Both LOW and SLEEP indicators will
be on.
- LOW speed wind for 10 seconds and stops for 5 second. This process alternates in every
15 seconds until the unit is power off.
Note: To avoid overcooling, do not adjust the wind direction directly to human body.
SPEED button
1. When the POWER button is pressed, HIGH speed indicator “HIGH” will be on and the
strongest wind comes out.
2. Press the SPEED button once, the MED speed indicator “MED” will be on and the mild
wind comes out.
3. Press the SPEED button again, the LOW speed indicator “LOW” will be on and the softest
wind comes out.
SWING button
Press the SWING button and the wind bar will start swinging. The swing can cover up to 60
degrees horizontally. Press the SWING button again to stop the wind bar at a desired
position.
TIMER button
1. Press the TIMER button to adjust the timer setting. Each press adds 30 minutes to the timer
and it can be set for up to 7.5 hours. The set timer is indicated on the display.
6
2. To clear the timer mode, press TIMER button for 16 times (one more press after it reaches 7.5
hours); the TIMER indicator will be off. Or POWER off the unit to reset all setting.
COOL button
1. Press the COOL button, if the water level is above the minimum level, the COOL indicator
will be turned on and the pump will start working.
2. After about 3 minutes, the comfortable cool wind with moisture will come out from the unit.
3. Press the COOL button again to turn the COOL mode off. The COOL indicator will be
turned off too and fresh dry wind will come out.
Note:
1. If COOL mode is selected when the water is under the low level or no water at all, the
alarm will sound after 90 sec. The COOL indicator will blink continuously for about 10 sec.
After 10 sec, the alarm stops and the COOL mode will be turned off too.
2. The unit can be used without water as a normal electric fan. In this situation, please keep
the COOL mode OFF.
Specifications
Water
Tank
Capacity
Rated
Voltage
Rated
Frequency
Rated
Power
Water
Consumption
Dimensions
(inch) WxDxH
N.W.
(lbs)
120V~
60Hz
80W
0.2-0.25L/h
4L
12.13x11.50x 34.76 11.24
Cleaning andMaintenance
z
z
IMPORTANT! Disconnect the plug from the power outlet before cleaning and maintenance
The body of the unit should be cleaned with damp cloth moistened with mild soap. Do not
clean it with wet cloth.
z
From time to time, depending on the nature of your water supply, you may need to clean the
interior of the water tank. This can be done in the following manner:
1) Fill the water tank with 1 cup (8 oz.) undiluted white vinegar;
2) Let the solution stand for 20 minutes.
3) With the vinegar in the water tank, clean all interior surfaces with a soft cloth or brush to
help remove scale.
4) Rinse the water tank thoroughly with clean water to remove scale and cleaning solution.
7
To Clean the Filter and Water Curtain (Please refer to Figure 6)
In order to keep good condition for humidifying and purifying, please clean the filtering system once
every two weeks.
Figure 6
1. Remove the back cover with dust filter from the unit;
2. Take out the water curtain from the unit;
3. Wash the filter net and water curtain with water. Then put it under sunlight to dry;
4. Install the dry water curtain into unit;
5. Install the back cover with dry filter onto the unit.
8
General Problems and Solutions
Problems
Reasons
No power
No operation
Solutions
z
z
z
z
z
z
Connect the plug to the power outlet.
Press the POWER button on the unit.
Take the unit to authorized service agency.
No air
blows out
Some parts are damaged
z
POWER button is not
pressed
Some parts are damaged
z
Press the POWER button to turn the unit
off.
Take the unit to authorized service agency.
The unit
can not be
turned off
z
z
z
z
Foreign objects are
inside the unit
Take off the side cover board and filtering
net then take out the objects.
The unit
z
z
Motor is out of order
Air wheel is loose
z
z
Take the unit to authorized service agency.
Take the unit to authorized service agency.
has noise
z
z
z
Lack of water
Pump is out of order
Water pipe drops off
z
z
z
Add the water.
Take the unit to authorized service agency
Take the unit to authorized service agency.
No
humidifying
No swing
z
Swing motor is out of order
z
Take the unit to authorized service agency.
SERVICE AND WARRANTY
Fujitronic warrants this product to be free from defects in materials and workmanship for one
(1) year from the date of original purchase. If you have a claim under this warranty, please return
the defective product to the original place of purchase for repair or replacement. Proof of purchase
is needed.
Fujitronic warrants this product to be free from defects and malfunction under ordinary and
appropriate use. Fujitronic disclaims all responsibility for inappropriate actions, directly or indirectly
cause the damage of this product.
The free of charge repair service does not cover the housing enclosure, flexible cord, plug
and defects caused by improper use or negligence of the user.
Los Angeles Headquarter
15329 Don Julian Rd
City of Industry CA 91745
Tel: (626) 336-3000
Fax: (626) 336-3459
DISCLAIMER: ALL INFORMATION AND TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER’S MANUAL ARE THE
PRESENTATION OF THE MANUFACTURER. FUJITRONIC HAS NOT CONDUCTED INDEPENDENT TEST TO THE
INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN.
9
|