Fujitsu Server TX150 S4 User Manual

PRIMERGY TX150 S4  
System configurator and order-information guide  
December 2005  
Contents  
Instructions  
Configuration diagram  
Configurator  
0
System software  
I
Basic unit  
II Processor  
III Memory  
IV Graphics  
V
Accessible drives  
VI Hard disk drives  
VII SCSI Controller  
VIII Disk array  
IX Communication/Network  
X
System management options  
XI Miscellaneous  
XII Country specific options  
Change report  
PRIMERGY Server  
 
System configurator and order-information guide  
PRIMERGY TX150 S4  
Status 25.11.2005  
Configuration diagram PRIMERGY TX150 S4  
System unit ( I )  
SIDE VIEW  
FRONT VIEW  
3 x 5.25"  
Standard Power Supply  
or  
1. PSU  
PS (I)  
5.25" x 1.6"  
5.25" x 1.6"  
2. PSU  
Redundant power supply option  
5.25" x 1.6" CD / DVD drive  
Modul 1  
Modul 3  
Pentium 4  
5"x1" Floppy disk (option  
Modul 2  
Accessible drives ( V )  
Modul 4  
Processor ( II )  
Extension slots  
Memory ( III )  
SCSI Controller ( VII )  
Disk array ( VIII )  
Hard disk drives ( VI )  
Communication/Network ( IX )  
PCIe x 1  
SCSI 1"  
SCSI 1"  
SCSI 1"  
SCSI 1"  
PCIe x 4 (x8 Slot)  
PCI short (5V) 32-Bit / 33MHz  
PCI short (5V) 32-Bit / 33MHz  
PCI-X 66 long (3,3V)  
PCI-X 66 long (3,3V)  
(Slot for Zero-Channel Controller)  
PCI long (5V) 32-Bit / 33MHz  
Key:  
Included in basic unit  
Option  
Fujitsu Siemens Computers  
Enterprise Products - PRIMERGY Server  
3 of 18  
 
System configurator and order-information guide  
Start PRIMERGY TX150 S4  
SW Configurator IA32  
PRIMERGY TX150 S4  
Status 25.11.2005  
with OEM-Software  
without OEM-Software  
for PRIMERGY Server  
for PRIMERGY Server  
Later use of OEM operating system  
software is not allowed,  
apart from few VMware  
add-ons  
VMware-Software  
- VCMS VirtualCenter Management Server  
- GSX Server and GSX Virtual Infrastructure Node  
- P2V Assistant Enterprise Edition  
For all SW products please refer to the corresponding software configurator accessible via  
the Extranet under Configuration & Tools, -All configurations, -Software, URL see below.  
Microsoft - Software: **)  
- Small Business Server 2003  
- Windows Server 2003,  
Web Edition (only English)  
OES/NetWare-Software ***)  
PRIMECLUSTER *)  
- Clustering  
- NetWare  
- Load Balancing  
Standard Edition  
Enterprise Edition  
- Additional loose  
Linux - Software: **)  
Client-Access-Licenses (CALs)  
(not for Web Edition)  
- SUSE Linux Enterprise Server  
- SUSE Professional Linux  
- Red Hat Enterprise Linux  
SCO - Software: **)  
- SCO OpenServer  
- SCO UnixWare  
CITRIX-Software für  
Windows: W-MF  
- Presentation Server  
LoadBalancing  
Additional User Licences  
Manageability Software: V**)  
- RemoteView Software  
- RemoteView Service Board  
- RemoteDeploy  
Details eg. version numbers are published  
in the separate SW-Configurator  
*) Pay attention to the PRIMECLUSTER release and ordering information in the Extranet under  
- Terminal Server Deploy  
- vPMS 2005std  
- Altiris Server Deployment  
**) Pay attention to the release and ordering information in PRINCE -> Operating System  
Backup-Software /  
Application-Software: U  
- ARCserve  
***) Supply over distribution or procurement from FSC VP BC Software  
- openSM2  
Various Software Configurators and release lists (OS-Matrix / System Management / Security) can be optain under the following adresses:  
for partners:  
Continue with PRIMERGY  
HW configurator  
Fujitsu Siemens Computers  
4 of 18  
Enterprise Products - PRIMERGY Server  
 
System configurator and order-information guide  
Start PRIMERGY TX150 S4  
SW Configurator EM64T  
PRIMERGY TX150 S4  
Status 25.11.2005  
with OEM-Software  
without OEM-Software  
for PRIMERGY Server  
for PRIMERGY Server  
Later use of OEM operating system  
software is not allowed,  
apart from few VMware  
add-ons  
For all SW products please refer to the corresponding software configurator accessible via  
the Extranet under Configuration & Tools, -All configurations, -Software, URL see below.  
Microsoft - Software: W  
Linux - Software: L *) **)  
only  
- Windows Server 2003,  
x64 Standard Edition  
only  
- SuSE Linux Enterprise Server  
EM64T  
EM64T - Red Hat Enterprise Linux  
x64 Enterprise Edition  
- Additional loose  
Client-Access-Lizenzen (CALs)  
Details eg. version numbers are published  
in the separate SW-Configurator  
Manageability Software: V**)  
- RemoteView Software  
- RemoteView Service Board  
- RemoteView Diagnosis  
*) Pay attention to release information on datasheet under  
**) Pay attention to release and order information in PRINCE -> Operating System  
***) Supply over distribution or procurement from FSC VP BC Software  
Various Software Configurators and release lists (OS-Matrix / System Management / Security) can be optain under the following adresses:  
for partners:  
Continue with PRIMERGY  
HW configurator  
Fujitsu Siemens Computers  
5 of 18  
Enterprise Products - PRIMERGY Server  
 
System configurator and order-information guide  
Start PRIMERGY TX150 S4  
PRIMERGY TX150 S4  
Status 25.11.2005  
Section  
Basic unit  
I
System unit consisting of:  
* Housing including standard power supply (no redundancy)  
* Sliding screen with lock (only for floorstand version)  
Systemboard with:  
* 7 PCI slots:  
1x PCIe x 1  
1x PCIe x 4 (x8 Slot)  
1x PCI-X 66 long (3,3V)  
1x PCI-X 66 (3,3V) ZCR Slot  
1x long / 2x short 32Bit / 33MHz (5V)  
* 4 memory slots for up to 8GB (PC4200) registered DDR II RAM (ECC), max. 2GB modul per slot  
* 1 drive bay 3.5" occupied by 1 floppy disk 1.44MB 1" height (optional)  
* 3 Einbauplätze 5,25" für bedienbare Laufwerke  
* 4 bays 1" for hot plug SCSI HD)  
* ATI Range XL Graphic controller 8MB  
* Intel Broadcom (5721) 10/100/1000 Mb/s on-board  
* 1 x Fast-IDE (ATA) Controller on-board (for 1x 2 devices)  
* 1-channel Ultra 320 SCSI Controller LSI 1020A on-board  
with HW RAID IME (IME = Integrated Mirroring Enhanced)  
Options:  
* Hot plug PS or a second redundant hot plug PS version can be configured by ordering the  
appropriate upgrade option  
* LSI Zero Channel RAID option, simultaneous use of HD and Tape Drive possible  
Cables:  
1. IDE cable for CD/DVD  
2. With SCSI variant wide LVD SCSI cable for connection of the HD backplane and two  
accessible drives  
PS/2 mouse (only for floorstand version)  
ServerStart packet incl. ServerBooks CD, ServerSupport CD and ServerView  
External Interfaces:  
2x RS-232-C (serial, 9 pins)  
1x Centronics (parallel, 25 pins, EPP/ECP compatible)  
1x keyboard (PS/2)  
1x mouse (PS/2)  
1x VGA (15 pins)  
1x USB 2.0 on front and 2x USB 2.0 on rearside  
1x LAN RJ45  
Cables included in basic unit  
Connections  
Cable  
PRIMERGY TX150 S4  
1.  
2.  
Key:  
IDE CD/DVD  
¡
¥
¡
¡
68pins  
68 or 50pins  
IDE  
¥
¥
¡
Backplane for 1x4  
SCSI hard disks  
¥
¥
¥
terminator  
incl. terminator  
A
Fujitsu Siemens Computers  
6 of 18  
Enterprise Products - PRIMERGY Server  
 
System configurator and order-information guide  
A
PRIMERGY TX150 S4  
Status 25.11.2005  
Floorstand version SCSI basic unit  
Pentium 4 processor, memory  
19" Rack version SCSI basic unit (5 U)  
Pentium 4 processor, memory  
PD 820 2.8GHz/800MHz/2x1MB 512MB  
PD 820 2.8GHz/800MHz/2x1MB 1GB  
PD 820 2.8GHz/800MHz/2x1MB 2GB  
S26361-K999-V136  
S26361-K999-V146  
S26361-K999-V156  
PD 820 2.8GHz/800MHz/2x1MB 512MB  
PD 820 2.8GHz/800MHz/2x1MB 1GB  
PD 820 2.8GHz/800MHz/2x1MB 2GB  
S26361-K999-V336  
S26361-K999-V346  
S26361-K999-V356  
S26113-F483-E1  
floorstand  
versions  
S26113-F483-E1  
hot plug power supply upgrade option  
With this option the basic units contains  
1 hot plug power supply, 1 power  
backplane and 1 dummy cover  
replacing the standard power supply  
(no redundancy !)  
hot plug power supply upgrade option  
With this option the basic units contains  
1 hot plug power supply, 1 power  
backplane and 1 dummy cover  
replacing the standard power supply  
(no redundancy !)  
A second, redundant  
power supply requires  
an additional power  
cord  
(section XII)  
max. 1x per system  
max. 1x per system  
S26113-F483-E11  
S26113-F483-E11  
2nd power supply module (PSU)  
for redundancy  
2nd power supply module (PSU)  
for redundancy  
occupies one bay for  
hot plug power supply  
max. 1x per system  
occupies one bay for  
hot plug power supply  
max. 1x per system  
For later conversion of basic units with standard power supply  
to hot plug power supply, the following kit is available:  
1.) hot plug PS upgrade kit, incl. 2 PS module:  
Conversion standard into hot plug PS  
2.) Supplementary power supply module  
for redundancy or repair  
S26113-F483-L1  
S26113-F483-L11  
B1  
B2  
Fujitsu Siemens Computers  
7 of 18  
Enterprise Products - PRIMERGY Server  
 
System configurator and order-information guide  
B1  
B2  
PRIMERGY TX150 S4  
Status 25.11.2005  
PRIMERGY Floorstand  
PRIMERGY Rack  
PRIMECENTER- Rack  
SNP:SY-F1647E301-P  
"rack-mounting ex factory"  
This service is to be ordered once  
per installable server/storage  
subsystem, in order to get the  
server/storage subsystem  
Installation ex works for one  
server or subsystem  
Hereby the rack will be delivered  
completely pre-mounted and  
all wired connections are tested  
With racks 12U, 24U, 38U:  
Systems and components  
will be delivered installed in the rack  
With racks 46U:  
mounted into the PRIMERGY racks.  
In case of the 46 U PRIMERGY rack,  
this service has to be ordered,  
to get the mounting kits and the  
cables installed.  
Systems and components  
will be delivered separately  
To be ordered only together with  
a PRIMERGY-  
PRIMECENTER rack  
e.g.:SNP:SY-K614V10x-P  
S26361-K826-V10x  
refer configurator PC-rack  
max. 1x per System  
For later conversion of TX150 base unit floorstand into base unit rack the following kit is availible  
1.) Conversion TX150S4 base unit floorstand into base unit rack  
rack mount kit has to be ordered separately  
S26361-F2618-L240  
For (later) mounting in racks the following kits are available:  
1.) PRIMERGY Classic-rack 42/23U adapter kit:  
incl. cable carrier  
S26361-F1331-L300  
S26361-F2734-L32  
S26361-F2734-L32  
2.) PRIMERGY DC- / PC- rack mounting kit:  
incl. DC- PC- bracket, cable managment  
3.) PRIMERGY mounting kit for server racks  
conforming to EIA standards EIA-310-D for 19" racks.  
C
Fujitsu Siemens Computers  
8 of 18  
Enterprise Products - PRIMERGY Server  
 
System configurator and order-information guide  
PRIMERGY TX150 S4 Status 25.11.2005  
C
Section  
Processor  
II  
Section  
Memory  
III  
There are 2 memory banks with 2 DIMM slots each.  
Single channel memory configuration allow maximum flexibility:  
Additional memory can be configured as single memory modules.  
Dual channel memory configurations for maximum performance:  
For optimum performance memory has to be configured in pairs of memory modules with identical size.  
S26361-F3000-E513  
Main memory 512MB  
DDR2 533/PC2-4200 ub ECC  
consisting of one module  
occupies one bank  
S26361-F3000-E514  
Main memory 1GB  
S26361-F3000-E515  
Main memory 2GB  
DDR2 533/PC2-4200 ub ECC  
consisting of one module  
occupies one bank  
DDR2 533/PC2-4200 ub ECC  
consisting of one module  
occupies one bank  
3x  
max. 3x per system  
max. 3x per system  
max. 3x per system  
Section  
Graphics  
IV  
ATI Rage XL (8MB)  
D
Fujitsu Siemens Computers  
9 of 18  
Enterprise Products - PRIMERGY Server  
 
System configurator and order-information guide  
PRIMERGY TX150 S4 Status 25.11.2005  
D
Section  
Accessible drives  
V
There are 3x 5.25" bays for accessible drives:  
- 1x 5.25" bay is occupied by a DVD-/CD- respectively a CD-RW drive  
- 2 x 5.25" bays remaining, can be occupied by 2x accessible drives  
Setup TX150 S4 by ServerStart is supported with following configurations:  
no DVD, no CD:  
remote installation only ( PXE service & DHCP server required)  
built in CD/DVD:  
UNC Network share reachable or USB Floppy or MemoryBird connected  
One of the following USB devices must be used for integrating the drivers during installation  
process if no automized (e.g. Serverstart / Altiris / RIS / ADS / …) installation is done:  
1) FDD USB (external): external USB FDD (USB cable included)  
2) USB Memorybird: Memorybird 256 MB  
Memorybird 1GB  
S26391-F264-L226  
S26391-F6046-L256  
S26391-F6046-L24  
S26361-F2575-E1  
Floppy disk drive 1"  
Connector: 26pin  
incl. description (Ger/US)  
1" * 3.5", anthracite bezel  
max. 1x per system  
SNP:SY-F2234E1-A  
S26361-F3148-E1  
DVD-ROM ATAPI  
DVD-RW 16x super multi drive  
all formats, DUAL/DL, DVD-RAM  
only W2K, W3K and Linux  
1.6 x 5.25", anthracite bezel  
max. 1x per system  
2x  
incl. description (Ger/US)  
1.6 x 5.25", anthracite bezel  
max. 2x per system  
S26361-F3157-E3  
Tape drive LTO2HH Ultrium  
200GB, 24MB/s, U160 SCSI  
Connector: HD68  
without cable  
incl. description (Ger/US)  
data and cleaning cartridge  
1.6 * 5.25", anthracite bezel  
max. 1x per system  
S26361-F2849-E3  
Tape drive VXA-2  
80GB, 6MB/s, U2W SCSI  
Connector: HD68  
2x  
without cable  
incl. description (Ger/US)  
data and cleaning catridge  
1.6 x 5.25", anthracite bezel  
max. 2x per system  
S26361-F2848-E3  
Tape drive DDS Gen5  
S26361-F2848-E31 (only for OBDR)  
DDS-G5 for One buttom dis. recov.  
36GB, 3MB/s, U2W SCSI  
Connector: HD68  
without cable  
incl. description (Ger/US)  
data and cleaning catridge  
1.6 x 5.25", anthracite bezel  
max. 2x per system  
E
Fujitsu Siemens Computers  
10 of 18  
Enterprise Products - PRIMERGY Server  
 
System configurator and order-information guide  
E
PRIMERGY TX150 S4  
Status 25.11.2005  
S26361-F2814-E6  
Backup drive and hard disk should run on separate channels  
68-Pin Kit for accessible drives  
Cable with Terminator  
To connect acc. drives to  
separate SCSI controller  
max. 1x per system  
If internal HDD's are connected at the RAID controller  
(not IME/ZCR), then for internal accessible drives  
the cable S26361-F2814-E6 must be ordered additionally!  
Section  
Hard Disk Drives  
VI  
S26361-F3121-E173  
S26361-F3121-E114  
S26361-F3121-E130  
Hard disk 73GB in 1" carrier  
10000rpm,<5,5ms, 8MB Cache  
Ultra 320 SCSI (320MB/s)  
Interface: Wide SCA (80-pins)  
hot plug/hot replace tray  
occupies 1" bay  
Hard disk 146GB in 1" carrier  
10000rpm,<5,5ms, 8MB Cache  
Ultra 320 SCSI (320MB/s)  
Interface: Wide SCA (80-pins)  
hot plug/hot replace tray  
occupies 1" bay  
Hard disk 300GB in 1" carrier  
10000rpm,<5,5ms, 8MB Cache  
Ultra 320 SCSI (320MB/s)  
Interface: Wide SCA (80-pins)  
hot plug/hot replace tray  
occupies 1" bay  
SCSI/RAID controller necessary  
max. 4x per system  
SCSI/RAID controller necessary  
max. 4x per system  
SCSI/RAID controller necessary  
max. 4x per system  
4x  
S26361-F3121-E573  
S26361-F3121-E514  
Hard disk 73GB in 1" carrier  
15.000rpm,<4ms, 8MB Cache  
Ultra 320 SCSI (320MB/s)  
Interface: Wide SCA (80-pins)  
hot plug/hot replace tray  
occupies 1" bay  
Hard disk 146GB in 1" carrier  
15.000rpm,<4ms, 8MB Cache  
Ultra 320 SCSI (320MB/s)  
Interface: Wide SCA (80-pins)  
hot plug/hot replace tray  
occupies 1" bay  
SCSI/ RAID controller necessary  
max. 4x per system  
SCSI/ RAID controller necessary  
max. 4x per system  
F
Fujitsu Siemens Computers  
11 of 18  
Enterprise Products - PRIMERGY Server  
 
System configurator and order-information guide  
PRIMERGY TX150 S4 Status 25.11.2005  
F
Section  
SCSI-Controller  
VII  
All internal cables and adapters are included within the basic units and components respectively  
Cabeling priorities:  
internal HDs are cabled according to following priorities.  
(Prio 1 - 3 ):  
1.) For a configuration without any Disk Array Controller and without zero channel RAID  
the onboard U320 Controller is connected to the internal HDs.  
2.) For a configuration with a 2-channel Disk Array controller (without zero-channel RAID)  
One channel will be connected with the internal hard disks.  
The second channel is externally available.  
internal backup devices are cabled according to following priorities.  
(Prio 1 - 2 ):  
1) For a configuration without additional SCSI controller  
the onboard U320 controller is connected to internal backup devices  
2) For a configuration with Adaptec SCSI Card 29160 S26361-F2399-E2  
(without SCSI 160 controller S26361-F2644-E11)  
this controller is connected to internal backup devices  
A. on-board SCSI-controller for accessible drives and SCSI-HDs  
1-channel Ultra 320 SCSI on-board controller; included as standard.  
Example for IME with 3 data devices:  
LSI Integrated Mirroring Enhanced (IME) is a RAID 1 implementation (no RAID 0 support). It can be operated also with an odd  
number of hard disks (max. one RAID 1 Set). There are, depending on system, up to 6 hard disks, including a hot spare disk,  
possible. Supportet are only the operating systems Windows2000/2003 as well as SuSE and RedHat Linux.  
All internal cables and adapters for the basic unit and for components are included.  
1x per TX150S4  
T26139-Y3849-L1  
Only SX10 Backup is released for the external  
connection of the on-board SCSI controller  
and the 29160.  
External on-board SCSI Interface  
Cable and external  
connector interface (HD68)  
occupies one connection panel  
max. 1x per system for ext.  
Cable sold separately not mounted in factory.  
Use this cable only if on-board controller is not  
used otherwise (eg. S26361-F2814-E6)  
G
Fujitsu Siemens Computers  
12 of 18  
Enterprise Products - PRIMERGY Server  
 
System configurator and order-information guide  
PRIMERGY TX150 S4 Status 25.11.2005  
G
B. SCSI controller for internal backup drives  
S26361-F2399-E2  
SCSI 160 Controller  
Adaptec SCSI Card 29160  
1 channel: LVD + Fast/ Ultra (decoupl.)  
LVD connect. for HD, without cable  
Fast/Ultra connect. for acc. drives  
64/66 PCI, min 180 mm  
int: Fast 50-pin or Ultra HD68  
+ LVD HD68; ext: HD68(LVD)  
SW:  
max. 1x per system  
S26361-F2814-E6  
68-Pin Kit for accessible drives  
Cable with Terminator  
To connect acc. drives to  
separate SCSI controller  
max. 1x per system  
C. SCSI controller for external drives and peripheral devices  
S26361-F2399-E1  
Only SX10 Backup is for external  
connection at the SCSI controller.  
SCSI U160 controller  
Adaptec SCSI Card 29160  
1 channel: LVD + Fast/ Ultra (decoupl.)  
LVD connect. for HD, without cable  
Fast/Ultra connect. for acc. drives  
64/66 PCI, min 180 mm  
int: Fast 50 pol oder Ultra HD68  
+ LVD HD68; ext: HD68(LVD)  
SW:  
max. 1x per system  
Section  
Disk Array  
VIII  
D. LSI - Controller  
1-channel Ultra 320 SCSI on-board controller with LSI Integrated Mirroring (IME)  
Standard SCSI-cabling of a PRIMERGY TX150 S4 basic unit with on-board controller  
Ultra 320 SCSI controller is connected to the internal hard disks and internal backup devices,  
if no additional HD/backup device controllers are configured.  
1x per PRIMERGY TX150 S4  
D. zero-channel RAID controller (320-0x) for internal Disk Array  
and additional RAID controllers for internal / external Disk Array  
S26361-F3085-E128  
0-channel RAID controller  
LSI  
320-0x  
128MB SDRAM ECC Cache  
BBU optional  
Zero channel RAID controller  
LSI must be installed in the  
blue marked bay.  
in combination with on-board  
U320 SCSI controller  
without cable  
64Bit/133MHz PCI-X controller  
3.3V power supply & signaling  
max. 1x per system  
With zero channel RAID controller  
the IME function is no longer  
available.  
S26361-F3085-E10  
Cache Battery Backup Unit  
max. 1x pro Controller  
to be  
continued  
on next page  
H
Fujitsu Siemens Computers  
13 of 18  
Enterprise Products - PRIMERGY Server  
 
System configurator and order-information guide  
PRIMERGY TX150 S4 Status 25.11.2005  
H
continued  
on previous  
E. 2-Kanal Ultra 320 SCSI Controller für Disk Array  
page  
S26361-F3090-E256  
2-channel RAID Controller U320  
LSI  
320-2x  
256MB SDRAM ECC Cache  
default with TBBU  
1x  
plug: internal 2x HD68;  
external: 2x VHDCI  
without cable  
64/133 PCI-X controller, 180mm  
3.3V and 5V tolerant signaling  
max. 1x per system  
The fitting connection cables can be found in the configurator  
of the external storage system and / or rack.  
S26361-F2814-E6  
Backup drive and HDD should run on separate channels.  
68-Pin Kit for accessible drives  
Cable with Terminator  
To connect acc. drives to  
separate SCSI controller  
max. 1x per system  
If internal HDD's are connected at the RAID controller  
(not IME/ZCR), then for internal accessible drives  
the cable S26361-F2814-E6 must be ordered additionally!  
I
Fujitsu Siemens Computers  
Enterprise Products - PRIMERGY Server  
14 of 18  
 
System configurator and order-information guide  
PRIMERGY TX150 S4 Status 25.11.2005  
I
Section  
Communication / Network  
IX  
Gigabit Ethernet Contr. on-board  
The Intel LAN controllers 1000MT can be used  
with the on-board controller in Teaming Mode  
Broadcom  
ext: for RJ 45-connector  
SW: AFT, VLAN, Fast Channel  
S26361-F3053-E1  
S26361-F3142-E1  
Gigabit Ethernet Contr. 1000TX  
Eth. Ctrl 1x1Gbit PCI-X Pro/1000MT Cu  
Intel PRO/1000 MT Server Adapter  
Adapter Teaming Support  
Gigabit Ethernet Contr. 1000TX  
Eth. Ctrl 1x1Gbit PCI32 PRO/1000GT Cu  
Intel Pro/1000 GT Adapter  
PCI 32 (33/66MHz),  
PCI-X (PCI64/133), min 165 mm  
ext: for RJ45-plug, Cat 5  
ext: for RJ45-plug, Cat 5  
connection with Cat 5 cabling  
SW: VLAN, Fast & Gbit Etherchannel  
max. 4x per system  
connection with Cat 5 cabling  
SW: VLAN, Fast & Gbit Etherchannel  
max. 4x per system  
4x  
S26361-F3011-E1  
Gigabit Ethernet Contr dual 1000TX  
Intel Pro/1000MT dual Server Adapter  
Adapter Teaming Support  
PCI-X (PCI64/133), min 163 mm  
ext: for RJ45-plug, Cat 5  
connection with Cat 5 cabling  
SW: VLAN, Fast Etherchannel  
max. 2x per system  
S26361-F1809-E2  
ISDN SO Controller PCI  
Eicon Diva Server BRI-2M 2.0  
Incl. SO-connector  
occu. short PCI slot min. 170 mm  
SO-Interface  
max. 2x per system  
J
Fujitsu Siemens Computers  
15 of 18  
Enterprise Products - PRIMERGY Server  
 
System configurator and order-information guide  
PRIMERGY TX150 S4 Status 25.11.2005  
J
Section  
System management options  
X
S26361-F2425-E103  
RSB S2 LP 3HU  
RemoteView Service Board S2  
Low Profile Version with 3 U bracket  
for one standard PCI-slot  
incl. cables and RV SW  
max. 1x per system  
S26361-F2425-E305  
RSB S2 LP external power supply  
RemoteView Service Board S2  
low profile external power supply  
including power cable  
with Euro- and Euro socket connector  
Section  
Miscellaneous  
XI  
S26361-F1652-L4  
In connection with rack configurations  
Modem external 56kbps (V.90)  
MultiTech  
the install variant of the modem  
(S26361-F1652-E4) has to be ordered  
(see rack configurator)  
MT5643ZBA-Global  
international approval  
incl. 2m Telephon cord RJ11/RJ11  
Adapter Plug RJ11/TAE  
Serial Interface cable DB25m / DB9f  
AC-Adapter w. German Power Cord  
occupies one COM port  
max. 1x per system  
K
Fujitsu Siemens Computers  
16 of 18  
Enterprise Products - PRIMERGY Server  
 
System configurator and order-information guide  
PRIMERGY TX150 S4 Status 25.11.2005  
K
Section  
Country specific / rack specific options  
XII  
A country specific power cord has to be ordered for all floorstand versions:  
- once per basic unit and an additional second cable  
- if an second hot plug, redundant power supply modul is ordered.  
PRIMERGY TX150 S4 Floorstand  
PRIMERGY TX150 S4 Rack  
Power cord for following countries:  
1,8 m, grey  
Country specific power cords are not  
required for rack versions, except for USA  
&Canada. Power cords are shipped in a rack  
version with inlet connector for non-heating  
apparatus. (1x with Standard PSU,  
T26139-Y1740-E10  
D, A, B, F, NL, FIN, S, N, E, P, RUS, TR  
max. T26139-Y1742-E10  
USA, Canada  
Switzerland  
2 x  
T26139-Y1743-E10  
T26139-Y1744-E10  
T26139-Y1745-E10  
T26139-Y1746-E10  
T26139-Y3850-E10  
UK, Ireland  
2x with hot plug upgrade)  
Italy  
Denmark  
T26139-Y1742-E10  
USA, Canada  
No power cord as order option  
For shipments to USA&Canada, you have to order  
one power cord (1,8m, grey) per power supply.  
Attention: For connection of a monitor  
to the system an additional country  
specific power cord has to be  
ordered as option.  
Power cord for optional monitor connection for the following countries:  
1.8m, grey  
T26139-Y1740-L10  
T26139-Y1742-L10  
T26139-Y1743-L10  
T26139-Y1744-L10  
T26139-Y1745-L10  
T26139-Y1746-L10  
D, A, B, F, NL, FIN, N, S, E, P, RUS, TR  
USA, Canada  
Switzerland  
UK, IR  
Italy  
Denmark  
Powercord 3-way splitter 1M to 3F  
0.78m, grey  
T26139-Y3692-L1  
Adapter for the connection of up to 3 PS-modules or up to  
2 PS-modules and one monitor to the mains connection.  
Both, standard and hot plug power supplies, are supported.  
Other options and Peripherals  
For other options refer to the section "Product-specific options  
These options are supplied loose with the shipment.  
For suitable peripherals for this product refer to the section "Peripherals/communication".  
Option for Floorstand  
keyboards for floorstand versions for following countries:  
S26381-K397-E110  
S26381-K397-E120  
S26381-K397-E140  
S26381-K397-E155  
S26381-K397-E165  
S26381-K397-E180  
S26381-K397-E185  
USA / international  
Germany  
France  
Sweden / Finland  
United Kingdom  
Spain  
Italy  
End PRIMERGY TX150 S4  
Fujitsu Siemens Computers  
17 of 18  
Enterprise Products - PRIMERGY Server  
 
System configurator and order-information guide  
PRIMERGY TX150 S4 Status 25.11.2005  
Cange Report  
Date  
Order number  
Changes  
2005-11-23 S26361-F1809-E2  
2005-03-31  
ISDN SO Controller PCI Eicon Diva Server BRI-2M 2.0 - now available  
First release  
Fujitsu Siemens Computers  
18 of 18  
Enterprise Products - PRIMERGY Server  
 

Echo Edger PE 225 User Manual
Edimax Technology Network Router Edimax user Manual Router User Manual
Ericsson Two Way Radio MTL SX User Manual
Fisher Paykel Ventilation Hood HS60CIWX3 User Manual
Flowtron Outdoor Products Insect Control Equipment BK 15D User Manual
Futrex Scale 5500A WL User Manual
Gaggia Espresso Maker 4332077000 User Manual
GE Computer Drive 97845 User Manual
GE Ventilation Hood JV347X User Manual
Gianni Industries Switch CP 21 GE User Manual