AIS INTERFACE
IF-1500AIS
SAFETY INSTRUCTIONS
Safety Instructions for the Installer
Safety Instructions for the Operator
WARNING
WARNING
Turn off the power at the switchboard
before beginning the installation.
Do not disassemble or modify the
equipment.
Fire, electrical shock or serious injury can
result.
Fire or electrical shock can result if the
power is left on.
Immediately turn off the power at the
switchboard if the equipment is emitting
smoke or fire.
Do not install the equipment where it
may get wet from rain or water splash.
Water in the equipment can result in fire,
electrical shock or damage the equipment.
Continued use of the equipment can cause
fire or electrical shock. Contact a FURUNO
agent for service.
Be sure that the power supply is
compatible with the voltage rating of
the equipment.
Make sure no rain or water splash leaks
into the equipment.
Connection of an incorrect power supply
can cause fire or damage the equipment.
Fire or electrical shock can result if water
leaks in the equipment.
Keep heater away from equipment.
CAUTION
A heater may melt the power cord, which
can result in fire or electrical shock.
Observe the following compass safe
distances to prevent interference to a
magnetic compass:
Do not place liquid-filled containers on
the top of the equipment.
Standard Steering
compass compass
Fire or electrical shock can result.
0.55 m
0.35 m
1
Foreword
FURUNO Electric Company thanks you for purchasing the IF-1500AIS AIS Interface. We
are confident you will discover why the FURUNO name has become synonymous with
quality and reliability.
Your equipment is designed and constructed to meet the rigorous demands of the marine
environment. However, no machine can perform its intended function unless properly
installed and maintained. Please carefully read and follow the installation and maintenance
procedures set forth in this manual.
Thank you for considering and purchasing FURUNO.
Features
The IF-1500AIS enables connection of the FURUNO AIS Transponder FA-100 to the
NavNet2 Series radars to display AIS information on the radar and plotter displays. AIS
target data input from the transponder are selected and sorted (by range, CPA/TCPA ,etc.),
format-converted and then output to the NavNet2 series radar.
Equipment List
Name
Type
Code No.
Qty
Remarks
Standard supply
AIS Interface
IF-1500AIS
CP14-06500
—
1
Installation
Materials
000-040-013
1 set
1) Cable assy.
MJ-A15A3F0013-035-3A
MJ-A7SPF0003-050
MJ-A6SPF0012-050
2) Self-tapping screws 4x16,
4 pcs.
Spare Parts
Optional supply
Cable Assy.
Cable Assy.
Cable Assy.
Cable Assy.
SP14-03301
004-000-730
1 set
MJ-A15A3F0013-035-3A 000-145-880
1
1
1
1
MJ-A7SPF0003-050
MJ-A6SPF0012-050
MJ-A6SPF0012-100
000-136-730
000-134-424
000-133-817
2
System Configuration
Cable
Cable
MJ-A6SPF0012-050 (5 m)*
MJ-A7SPF0003-050 (5 m)
AIS Transponder
FA-100
NavNet2 Series
Radar, Plotter
IF-1500AIS
* 10 m cable optionally
available
Cable
MJ-A15A3F0013-035
12-24 VDC
Mounting
The unit can be mounted on a desktop or a bulkhead. When choosing a mounting location,
keep in mind the following points:
• Consider cable lengths.
• Choose a location away from rain and water splash and one which is not in direct
sunlight.
• Observe the maintenance space noted in the outline drawing to facilitate servicing.
• Observe the compass safe distances noted in the safety instructions at the beginning of
this manual.
Fix the unit to the mounting location with four self-tapping screws (4x16). Connect cables
referring to the interconnection diagram. Run a ground wire (local supply) between the
ground terminal and ship’s superstructure.
3
Wiring
Refer to the interconnection diagram at the back of this manual and the illustration below.
For IEC 61162-2
AIS
IF-1500AIS
-
-
-
External display
Aux. display
Pilot plug
J1:AIS IN
WHT
BLK
YEL
RD A
1
2
3
4
5
6
7
TD A
RD B
TD B
TD A
RD H
GRN
TD B
RD C
RED
BLU
ISO GND
ISO GND
F.G.
SIG. GND
SIG. GND
F.G.
MJ-A7SPF0003-050
Notice:
Do not connect "SIG. GND" of the IF-1500AIS
to "Frame Ground".
For IEC 61162-1, NMEA-0183
AIS
IF-1500AIS
J1:AIS IN
-
-
-
External display
Aux. display
Pilot plug
WHT
BLK
YEL
RD H
1
2
3
4
5
6
7
TD A
RD C
TD A
TD B
N.C
TD B
RD H
GRN
RD C
RED
BLU
SIG. GND
SIG. GND
F.G.
N.C
MJ-A7SPF0003-050
F.G.
Notice:
Do not connect "SIG. GND" of the IF-1500AIS
to "Frame Ground".
4
Data Sentences
The following data sentences are input to and output from the AIS Interface.
AIS
Transponder
ABM
BBM
ACK
VDM
VDO
ALR
LRI/LRF
ABK
TXT
ACA
LRI/LRF
AIS
Interface
ACK
TGT Qty
VDM
VDO
Sort Condition
ALR
TXT
P Sentences
NavNet2 Series
Radar, Plotter
Operation
No operation is required of the user. All AIS-related operations are carried out from the
NavNet2 series radar or plotter.
Cleaning
Dust may be removed from the cabinet with a soft dry cloth. For stubborn dirt, water-diluted
mild detergent may be used. Do not use chemical-based cleaning agents to clean the
cabinet; they can remove paint and markings.
Replacement of Fuse
The 3A fuse in the power cable protects the
equipment from reverse polarity and equipment
trouble. If the fuse blows, find the cause before
WARNING
Use the proper fuse.
replacing the fuse. If it blows after replacement
request service.
Use of a wrong fuse can result in damage
to the equipment or cause fire.
5
FURUNO
IF-1500AIS
SPECIFICATIONS OF
AIS INTERFACE
IF-1500AIS
1. PORTS
1.1 Number of ports
2 ports (IN/OUT)
38,400 bps
1.2 Baud rate
1.3 AIS IN port (RS-485)
Input data: VDM, VDO, ALR, ABK, TXT, ACA, LRI/LRF
Output data: ABM, BBM, ACK, LRI/LRF
1.4 DATA OUT port
1.5 Digital interface
Input data: ACK, Target quantity, Sort condition
Output data: VDM, VDO, ALR, TXT, P-sentences
IEC 61162-2
2. ENVIRONMENTAL CONDITIONS
2.1 Useable temperature
2.2 Relative humidity
2.3 EMC
-15°C to 55°C
95%(40°C)
IEC 60945
IP20
2.4 Waterproofing
3. POWER SUPPLY
4. COLOR
12-24 VDC, 0.2-0.1 A
N3.0
SP - 1
E4435S01B
A -1
1/1
14CS-X-9851 -3
PACKING LIST
IF-1500AIS
N A M E
DESCRIPTION/CODE №
O U T L I N E
Q'TY
1
ユニット
UNIT
IF-1500AIS
AISインターフェイス
AIS INTERFACE
000-152-849
予備品
ヒューズ
SPARE PARTS
SP14-03301
FGBO-A 3A AC125V
000-549-063
2
FUSE
工事材料
INSTALLATION MATERIALS
CP14-06500
MJ-A15A3F0013-035-3A
ケーブル組品MJ
1
1
1
4
POWER CABLE
000-145-880
MJ-A7SPF0003-050
ケーブル組品MJ
CABLE ASSY.
000-136-730
MJ-A6SPF0012-050
ケーブル組品MJ
SIGNAL CABLE ASSEMBLY
000-134-424
4X16 SUS304 1シュ
+トラスタッピンネジ
SELF-TAPPING SCREW
000-802-080
OMC-44350-*
000-152-852
図書
DOCUMENT
取扱説明書
1
OPERATOR'S MANUAL
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
14CS-X-9851
Y. Hatai
この図書には環境配慮型漂白
方式の用紙を使用しています。
・機器の修理・使用方法等に関するお問い合わせは、お買い上げの販売店・代理店、あるいは
最寄りの当社各支店・営業所へお願いします。
・お問い合わせは
発行
〒662-8580
兵庫県西宮市芦原町9番52号
本書の無断複写複製(コピー)は特定の
場合を除き、当社の権利侵害になります。
2005年 4月
初版発行
Printed in Japan
2005年 5月 23日 A2版発行
PUB.No.OMC-44350-A2
(DAMI ) IF-1500AIS
*00015285200*
*00015285200*
* 0 0 0 1 5 2 8 5 2 0 0 *
*OMC44350A20*
*OMC44350A20*
* O M C 4 4 3 5 0 A 2 0 *
|