Futrex Scale Futrex 5000 XL User Manual

USER'S MANUAL  
FUTREX7-5000/XL  
BODY FAT AND FITNESS COMPUTER  
FUTREX INC.  
130 Western Maryland Pkwy  
Hagerstown, MD 21740  
Version 8.4  
 
1.Main Body  
2
 
2.  
Optical Standard  
3.  
Light Wand  
3
 
PREPARATION  
1.  
Battery Installation  
Insert 6 1.5V "AA" size alkaline batteries into the battery compartment  
located on the rear of the Main Body. Be sure the batteries are  
oriented as indicated in the battery compartment.  
NOTE: Batteries must be alkaline type. Other types will not work.  
2.  
Light Wand  
Connect the Light Wand Cable to the connector jack located on the  
right hand side of the Main Body.  
It is recommended that the Light Wand always remain attached to the  
Main Body. This will avoid possible damage to the connector.  
3.  
A/C Adapter  
Connect the A/C Adapter cable to the connector jack located on the  
right hand side of the Main Body (the jack closest to the top of the unit).  
PRINTER PAPER INSTALLATION  
4
 
Remove the clear plastic cover from the printer.  
Start feeding the paper into the slit inside the Paper Roll Compartment by pressing the PAPER FEED key.  
NOTE: The paper must be thermal paper and cut square prior to inserting.  
5
 
MODELS OF THE FUTREX BODY FAT AND FITNESS COMPUTER  
There are two models available:  
! FUTREX-5000/XL  
Estimates the percent body fat of Adults only (ages 18-80)  
! FUTREX-5000A/ZL  
Estimates the percent body fat of:  
1) Adults  
2) Adolescent Children (13-17)  
3) Pre-Adolescent Children (5-12)  
CAUTION: This Manual is only for use with the FUTREX-5000/XL  
6
 
PERCENT BODY FAT MEASUREMENT  
TO ESTIMATE PERCENT BODY FAT: (Is date correct? See page 17.)  
1)  
Turn Power Switch ON.  
The display will show a software version number (e.g. 7.25) and will then start a 15 second countdown. The display will  
show Sd.  
2)  
3)  
4)  
Insert Light Wand into Optical Standard. Be sure the silver stripe on the Light Wand is aligned with the silver stripe from  
the Optical Standard.  
Press the ZERO ADJUST Key.  
The display will now show 0.0. The zero adjustment has been made.  
Remove Light Wand from the Optical Standard.  
Install the Light Shield on the Wand as shown in the sketch (allow the Wand to protrude from the edge of the shield by  
about 1/4 of an inch). The Light Shield was provided to ensure that no external light interferes with the estimation of  
percent body fat. Therefore, this shield should always be used when measuring percent body fat.  
The FUTREX-5000/XL is ready to start the body fat estimation sequence.  
5)  
6)  
7)  
8)  
Press ENTER to start the body fat estimation sequence.  
The FUTREX-5000/XL is normally delivered using English units (pounds and inches). The unit can be converted to accept  
metric units (see page 23).  
Enter Sex by pressing the MALE or FEMALE Key.  
Enter Weight in lb or kg. Press ENTER.  
7
 
9)  
Enter Body Frame by pressing the SMALL, MEDIUM or LARGE Key.  
There are many methods for measuring Frame Size. Futrex does not recommend any specific method but does offer two  
techniques often used for determining frame size:  
a)  
Ankle Girth  
!
!
Measure the ankle girth at the smallest point above the ankle with the tape as tight as possible.  
Standards  
Small Frame  
Medium Frame  
Large Frame  
Men  
Less than 8 in.  
8 to 9.25 in.  
Greater than 9.25 in.  
Women  
Less than 7.5 in.  
Wrist Girth  
7.5 to 8.75 in.  
Greater than 8.75 in.  
b)  
!
Place your left thumb and middle finger around your right wrist and gently squeeze your fingers  
together.  
!
!
Small Frame - Fingers overlap  
M
e
NOTE: If you have long fingers, this method may underestimate your frame size.  
d
ium Frame - Fingers touch  
!
Large Frame - Fingers do not touch  
8
 
10)  
11)  
Enter Height in inches or cm (whole numbers only: e.g. 68 in. is acceptable). Refer to page 23 to switch between English  
and Metric units. Press ENTER.  
Enter F.I.T. Value  
The following procedure provides a quantitative method to determine a subject's Physical Activity Rating.  
A person's F.I.T. value is a function of 3 parameters:  
!
!
!
Exercise Frequency - How often the exercise is performed.  
Exercise Intensity - How much energy is expanded during exercise.  
Exercise Time - How many minutes the exercise is performed during each session.  
The F.I.T. value is calculated by multiplying all three parameters:  
F.I.T. = Frequency x Intensity x Time  
11A)  
Enter Frequency Value. Press ENTER.  
FREQUENCY  
5
4
3
2
1
Daily or almost daily (6 or 7 times per week)  
3 to 5 times per week  
1 or 2 times per week  
A few times per month  
Less than once per month  
11B)  
Enter Intensity Value. Press ENTER.  
INTENSITY  
5
Aerobic activities that result in sustained heavy breathing and  
perspiration (e.g. high impact aerobics, running, speed swimming,  
distance cycling).  
4
3
Intermittent aerobic activities that result in sustained heavy breathing  
and perspiration (e.g. tennis, racquet-ball, squash).  
Moderate aerobic activity (e.g. normal bike riding, jogging, low impact  
aerobics).  
9
 
2
Moderate aerobic activity (e.g. recreational volleyball, moderate speed  
walking).  
1
Light aerobic activity (e.g. normal walking, golfing).  
11C)  
Enter Time Value. Press ENTER.  
TIME  
4
3
2
1
Over 30 minutes  
20 - 30 minutes  
10 - 20 minutes  
Under 10 minutes  
NOTE:  
IT IS IMPORTANT TO:  
Aim the silver stripe of the Light Wand directly toward the shoulder. Keep the arm relaxed  
(do not permit the subject to flex his/her muscles). A relaxed biceps can be achieved by having the subject  
seated while resting his arm (elbow bent) on a table.  
Use the Light Shield to block the external light. Always avoid measurements under strong  
lights (e.g. direct sunlight) because errors may occur.  
12)  
Place Light Wand firmly on biceps of the dominant arm (see page 11 for locating exact estimation point).  
10  
 
13)  
Press ENTER.  
T
h
e
CAUTION:  
Do not move the Light Wand while the decimal point is illuminated. The actual estimation is  
being made at that time.  
d
i
splay will flash a decimal point following the number "1". Then the number "2" will be displayed.  
14)  
15)  
Remove the Light Wand and replace it on the same point on the biceps.  
Press ENTER.  
The display will flash a decimal point following the number "2".  
16)  
Percent Body Fat is displayed and printed.  
The FUTREX-5000/XL will also print the following information:  
!
!
!
Fat Weight (lbs of body weight that is fat).  
Lean (fat-free) body weight.  
Total Body Water. This is the calculation of the subject's normal hydration state. The percent body water is  
based on research that has shown lean tissue to be composed of approximately 73% water, whereas fat  
contains 4 to 8% water. For example:  
Men between 6 - 24% Fat; 69 - 57% Water  
Women between 9 - 35% Fat; 67 - 50% Water  
To Repeat the Measurement Sequence  
Press ENTER and follow the steps outlined under 5-16.  
11  
 
Off Message  
An Off Message will appear and the FUTREX-5000/XL Automatic Power Down feature will turn the unit off if the user has not pressed  
any key for 6 minutes. To use the unit again, turn the Power Switch OFF and ON again.  
12  
 
SELECTING THE BICEPS MEASURING SITE  
2)  
3)  
Using a 12" ruler or the scale provided on the Arm Band, measure the length between the armpit and the inside of the  
elbow.  
To mark the Measurement Point, measure halfway between the armpit and the elbow at the "belly" of the biceps muscle.  
(More technically stated: measure along the exterior line of the biceps halfway between the antecubital fossa and the  
acromion).  
To mark this measurement site, place a small line on the medial side of the spot with a yellow highlighter or pen.  
4)  
5)  
Place the Light Wand on the Measurement Site with one hand. Place your other hand behind the triceps, using your  
thumb and middle finger to hold the black foam disk around the arm to block out external light.  
NOTE:  
It is suggested that the person being measured press the ENTER key with the hand not being  
measured.  
Body Fat Estimation is described on pages 6 - 10.  
13  
 
ADJUSTING THE PERCENT BODY FAT READING  
The FUTREX-5000/XL has been carefully calibrated to provide body fat estimations. The calibration is traceable to the generally  
accepted hydrostatic procedure.  
However, some users may desire to have the FUTREX-5000/XL estimations traceable to their own laboratory. For those users the  
following adjustment procedure is provided:  
1
Turn unit on.  
1)  
2)  
During countdown press CLEAR, SELECT PROGRAM, RISKS.  
The digital display will read "A1".  
Press ENTER.  
3)  
4)  
5)  
The digital display will show the value of the optical standard.  
If no change to the calibration is desired - press CLEAR.  
If you wish to change the calibration:  
Press SELECT PROGRAM, then press RISKS. The display will show "0.0" (if no calibration adjustment has been made)  
or the previously entered adjustment value.  
6)  
8)  
To adjust the calibration:  
Press the numbered key to enter the amount of adjustment. For example, if you want to decrease the instrument's  
estimates by 1.0% - press 1, press 0, then the minus sign, and then ENTER. All future body fat estimates will now read  
1.0% lower.  
Once the correct offset has been entered into the unit, press ENTER. The adjusted optical standard value will be  
displayed.  
14  
 
9)  
To exit this mode:  
Press CLEAR.  
ESTIMATING RELATIVE FAT DISTRIBUTION  
In addition to estimating percent body fat, a relative body fat estimation on other sites of the body (e.g. quadriceps, abdominal region)  
can be obtained using the FUTREX-5000/XL.  
1
Turn Power Switch ON.  
The display will show a software version number (e.g. 7.30) and will then start a 15 second countdown. The display will  
show "Sd".  
1)  
2)  
3)  
4)  
5)  
Insert Light Wand into Optical Standard.  
The silver stripe on the Light Wand should be lined up with the silver stripe on the Optical Standard.  
Press the ZERO ADJUST Key.  
The display will now show "0.0". The zero adjustment has been made.  
Press the Number "2" Key.  
This will shut off the printer function.  
Remove Light Wand from the Optical Standard.  
The FUTREX-5000/XL is ready to estimate relative body fat. The display will show "1".  
Place the Light Wand in the Light Shield and place firmly on the body part where you want to estimate the "Relative Fat".  
NOTE:  
It is important to:  
15  
 
!
Aim the silver stripe of the Light Wand vertically toward the upper portion of the body.  
Keep the body site to be estimated relaxed (do not permit subject to flex muscle area being  
!
estimated).  
!
Use the Light Shield to block the external light. ALWAYS avoid estimations under strong  
lights (e.g. direct sunlight) because errors may occur.  
!
Press ENTER.  
The display will then show a decimal point following the number "1". The number "2" will then be  
d
i
s
p
l
CAUTION:  
Do not move the Light Wand while the decimal point is illuminated. The  
actual estimation is being made at that time.  
a
yed.  
!Remove the Light Wand and replace it on the same site on the body. Press ENTER. The display will show a  
decimal point following the number "2".  
6)  
The Relative Body Fat Estimation is Displayed.  
16  
 
NOTE:  
This relative body fat is not a direct "Percentage" estimation. This value, however, can be used  
as a guide to monitor changes in fat distribution within the location estimated.  
To Estimate Another Site or Repeat an Estimation - Place the Light Wand firmly on the particular body site and follow steps outlined in 6 and  
7.  
OFF Message - An OFF Message will appear and the FUTREX-5000/XL Automatic Power Down feature will turn the unit OFF if the user has  
not pressed any key for 6 minutes. To use the unit again, turn the Power Switch OFF and then ON again.  
17  
 
SELF MEASUREMENT OF PERCENT BODY FAT  
1)  
2)  
Purpose of the Arm Band:  
!
Locates the measurement site on the biceps.  
!
Blocks out all external light that might interfere with the measurements when self testing percent body fat.  
Using a 12" ruler or the scale provided on the Arm Band, measure the length between the armpit and the inside of the  
elbow. Extend the Arm Band so the Scale is facing up.  
3)  
Adjust the gauge on the Arm Band to the length of your upper arm. The Gauge is adjusted correctly when  
the white arrows on either side of the Gauge point to the correct measured length.  
18  
 
4)  
Make a ring out of the Arm Band and place your dominant arm through the center of the ring.  
5)  
6)  
Tighten the Arm  
Band.  
To locate the proper measurement site, the Arm Band pointer should be perpendicular to the inside crease of the elbow  
joint (standard anatomical position/open palm).  
7)  
8)  
To measure percent body fat, follow steps 1 through 11 on pages 6 to 9.  
Insert Light Wand into the center hole of the Arm Band. Make sure the Light Wand touches the skin.  
9)  
Measure percent body fat by following steps 13 through 16  
SETTING THE CORRECT DATE  
on pages 9 and 10.  
19  
 
The FUTREX-5000/XL requires that the date be manually changed each day. Use the following procedure to change the date:  
1)  
2)  
Press SELECT PROGRAMS then press DATE. The printer will show the current setting, e.g. June 1, 1996.  
Printer then prompts user to change month. Use keypad to enter new month (i.e. "1" = January, "2" = February, ... "12" =  
December). If no change, just press ENTER.  
3)  
4)  
Printer prompts user to change day. If no change, press ENTER, or type in correct number and press ENTER.  
Printer prompts user to change year. If no change press ENTER, or type in correct two digits (e.g. year 2000 would be 00)  
NOTE:  
If an invalid month, day or year is entered, the display will reset to "0", and you must enter a  
correct value. For example, the only valid entries for month are 1 through 12. If in error you enter 15, the display  
will show "0".  
then ENTER.  
20  
 
PRINTOUT PROGRAMS  
The FUTREX-5000/XL provides two analysis programs for Adult User's only:  
!
Fitness Analysis  
!
Update Analysis  
FITNESS ANALYSIS  
The Fitness Analysis is based upon the Metropolitan Life Insurance Tables combined with the National Institutes of Health published  
data on the interrelationship between body weight/fat and longevity/health risks. The program prints diet and activity suggestions to allow you  
to reach the recommended fat/weight levels.  
This analysis provides the user with information that covers a broad spectrum of the technical literature. This is deemed necessary,  
because there is no "one best method" of performing a fitness analysis.  
To Obtain a Fitness Analysis Printout:  
1
Turn Power Switch ON  
The display will show a software version number (e.g. 7.30) and will then start a 15 second countdown.  
1)  
2)  
Press the CLEAR Key to cancel the 15 second countdown.  
Press the SELECT PROGRAM Key.  
NOTE:  
F4 must be set to "1" in the Function Mode; see page 25.  
3)  
Either press the FITNESS Key for final printout using the built-in printer  
Or press COLOR PRINTER for final printout using an external EPSON XL300 printer*  
21  
 
4)  
5)  
Enter Sex by pressing the MALE or FEMALE Key.  
Enter Height in inches or cm (whole numbers only; e.g. 68 in. is acceptable, 68.5 will not be accepted). See page 23 to  
switch between English and Metric units. Press ENTER.  
6)  
Enter Weight in lb. or kg. (whole numbers only). See page 23 to switch between English and Metric units. Press ENTER.  
Enter Body Frame Size by pressing SMALL, MEDIUM or LARGE. Refer to page 7 to determine size.  
Enter Age using the numbered keys. Press ENTER.  
7)  
8)  
9)  
Enter the Percent Body Fat obtained from the FUTREX-5000/XL (be sure to press the decimal point). Press ENTER.  
10)  
Enter Activity Level by pressing the LIGHT, MODERATE or HEAVY key. This value corresponds to your daily activity  
during normal working hours.  
11)  
12)  
Enter F.I.T. Level by entering in Frequency, Intensity and Time of your physical activity. Refer to Step 11 on page 8 to  
determine your F.I.T. rating.  
The complete Fitness Analysis is then printed.  
To Estimate Percent Body Fat: turn the FUTREX-5000/XL OFF and then ON again.  
Off Message  
An Off Message will appear and the FUTREX-5000/XL Automatic Power Down feature will turn the unit OFF if the user has not  
pressed any key for 6 minutes. To use the unit again, turn the Power Switch OFF and ON again.  
UPDATE ANALYSIS  
22  
 
This printout (for Adult Users only) allows you to compare your previous weight and percent body fat with your current values.  
To Obtain an Update Analysis Printout:  
1
Turn Power Switch ON.  
The display will show a software version number (e.g. 7.30) and will then start a 15 second countdown.  
1)  
2)  
3)  
4)  
5)  
Press the CLEAR Key to cancel the 15 second countdown.  
Press the SELECT PROGRAM Key.  
Press the UPDATE Key.  
Enter Sex by pressing the MALE or FEMALE Key.  
Enter Height in inches or cm (whole numbers only: e.g. 68 in. is acceptable, 68.5 will not be accepted). Press ENTER.  
Refer to page 23 to switch between English and Metric units.  
6)  
Enter Original Weight in lb. or kg. (whole numbers only). This value refers to the weight of the subject prior to starting any  
weight gain or reduction program. Press ENTER. Refer to page 23 to switch between English and Metric units.  
7)  
8)  
9)  
Enter Current Weight in lb. or kg. Press ENTER.  
Enter Body Frame by pressing the SMALL, MEDIUM or LARGE key. Refer to step 9 on page 7 to determine frame size.  
Enter Age using the numbered keys. Press ENTER.  
23  
 
10)  
Enter Original Percent Body Fat obtained from the FUTREX-5000/XL prior to starting any body fat gain/loss program (be  
sure to press the decimal point). Press ENTER.  
11)  
12)  
Enter Current Percent Body Fat. This is the percentage value recently obtained by the FUTREX-5000/XL. Press ENTER.  
Enter Activity Level by pressing the LIGHT, MODERATE or HEAVY key. This value corresponds to your daily activity  
during normal working hours.  
13)  
Enter F.I.T. by entering in values for Frequency, Intensity and Time of physical activity. Refer to step 11 on page 8 to  
determine your F.I.T. rating.  
14)  
15)  
Enter Number of Weeks between current and original body fat estimation.  
The complete Update Analysis will be printed.  
To Print Another Update Analysis: follow steps 3 through 16.  
To Estimate Percent Body Fat: turn the FUTREX-5000/XL OFF and then ON again.  
OFF Message  
An Off Message will appear and the FUTREX-5000/XL Automatic Power Down feature will turn the unit OFF if the user has not  
pressed any key for 6 minutes. To use the unit again, turn the Power Switch OFF and then ON again.  
24  
 
COLOR PRINTER  
The FUTREX-5000/XL can directly communicate with an external printer without need for any external computer using Futrex's  
unique full color fitness forms. The following is required if you desire to use this feature:  
!
!
!
Preprinted Color Forms - This 4 page form provides extensive data for your clients.  
Printer - Epson Model LX-300  
RS-232 Printer Serial Cable - To communicate from the FUTREX-5000/XL to the Epson Printer.  
This printing function is performed as follows: (NOTE: F4 must have been set to "0"; see page 25).  
1)  
2)  
Turn on both the printer and FUTREX-5000/XL. Wait for countdown to finish or press CLEAR. The RS-232 serial cable  
must be attached between the units.  
Press SELECT PROGRAMS, then COLOR PRINTER. The FUTREX-5000/XL internal printer will display:  
"Use Previous Data; 1 = YES, 2 = NO". If you type in "NO" (i.e. "2"), follow the Fitness Analysis Procedure  
described on page 19 starting with Step 5.  
3)  
4)  
If "YES" (i.e. "1") was typed in, the FUTREX-5000/XL's will use the data from the last person that was measured and the  
instrument's printer will ask:  
!
"Enter Activity Level" - This is the amount of daily physical activity the person does during normal work  
environment. It does not include any exercise program the person does. Enter either LIGHT (e.g. office work),  
MODERATE (e.g. someone delivering mail), or HEAVY (e.g. a ditch digger).  
Enter "Body  
described in  
(page 19, items  
Frame" and "Activity Level" as  
the Fitness Analysis procedure  
8 and 11).  
CAUTION:  
Color Forms must be in printer.  
 
NOTE:  
Printer must be set to 2400 baud rate. If a malfunction occurs (e.g. paper jam), you must turn  
off both the printer and the FUTREX-5000/XL before restarting.  
FUNCTION MODE  
The Function Mode provides the user with 3 program options:  
!
!
!
Selection of Metric or English units.  
Selection of a Calorie Limit Mode.  
Use of Dotson-Davis Equations.  
To Enter into the Function Mode:  
1
Turn Power Switch ON.  
1)  
2)  
Press the RISKS Key during the 15 second countdown.  
The letter "F" will appear on the screen.  
Now follow the appropriate instructions for the Function you want to change.  
F1 - Selection of English or Metric Units  
The subject's height and weight values can be printed in either English (lbs/in) or Metric )kg/cm) units.  
After entering the Function Mode:  
a)  
Press 1  
The display will show either "F1 0" or "F1 1".  
If "F1 0" is displayed, English Units are being used (lbs/in).  
If "F1 1" is displayed, Metric Units are being used (kg/cm).  
26  
 
b)  
To Change Between Units  
Press either 0 or 1 and the display will show the change.  
Press ENTER if this is correct.  
c)  
d)  
Press ENTER a second time. If you fail to press ENTER a second time, the FUTREX-5000/XL will continue to  
use the original setting stored in the FUTREX-5000/XL.  
e)  
To Exit the Function Mode, turn the FUTREX-5000/XL OFF.  
F2 - Selection Calorie Limit Mode  
The Fitness Analysis Program can be operated in two different calorie modes. The first mode allows the FUTREX-5000/XL to  
calculate the subject's daily caloric intake. The second mode allows the subject to enter his/her daily caloric intake value.  
After entering the Function Mode:  
1
Press 2  
The display will show either "F2 0" or F2 1".  
If "F2 0" is displayed, then the unit will automatically calculate the subject's daily caloric intake.  
If "F2 1" is displayed, the user will be asked to enter a specific calorie intake value.  
a)  
To Change Between Modes:  
Press either 0 or 1 and the display will show the change.  
b)  
c)  
Press ENTER if this is correct.  
To Exit the Function Mode, turn the FUTREX-5000/XL OFF.  
F3 - Use of Dotson-Davis Equations  
27  
 
After entering the Function Mode:  
1
Press 3.  
The display will show either "F3 0" or "F3 1".  
If "F3 0" is displayed, the Dotson-Davis Equation will be used.  
If "F3 1" is displayed, the Dotson-Davis Equation will be omitted from the Body Fat Estimation Program.  
a)  
b)  
To Change Between Equations:  
Press either 0 or 1 and the display will show the change. Press ENTER if this is the correct change.  
To Exit the Function Mode, turn the unit OFF.  
F4 - Color Printer Selection  
After entering the Function Mode:  
a)  
Press 4  
If "0" is displayed, the unit is set to print using the Color Forms.  
If "1" is displayed, unit is set to print Fitness Analysis on plain paper.  
To change, press "0" or "1". Press ENTER to save the change.  
To Exit the Function Mode, turn the unit OFF.  
b)  
c)  
F8 - Data Stream  
This function allows the FUTREX-5000XL measured data to be sent to an external PC computer.  
!
If F8 is "0", no data is being sent.  
!
If f8 is "1", all measured data will be sent to the external computer.  
F5 and F7 are not used, but they must be set to "0" or the instrument will not function properly. F6 is not used, but must be  
set to "1" or the instrument will not function properly.  
28  
 
TROUBLESHOOTING  
PROBLEM  
PROBABLE CAUSE  
CORRECTIVE MEASURES  
1) Display shows "LOBAT"  
Batteries are low  
a) Replace batteries (Refer to page 3).  
a) Bad connection between Light Wand  
and Probe Socket  
a) Be sure the Light Wand is properly  
inserted into the Probe Socket.  
2) Display shows "1999.9" or  
"-1999.99"  
b) Too much/too little light  
b) Be sure the Light Wand is properly  
seated in the Optical Standard when  
Zero Adjusting.  
3) Bad Repeatability  
a) Inconsistent measurement technique  
a) Make sure you are applying enough  
pressure between the Light Wand and  
the subject's arm.  
b) The silver line on the Light Wand  
must be aligned with the line on the  
Optical Standard when Zero Adjusting.  
c) When taking a measurement, the  
silver line on the Light Wand must point  
toward the subject's shoulder.  
d) Use the Light Shield to block the  
external light. Always avoid  
measurements under strong lights (e.g.  
direct sunlight) because errors may  
occur.  
29  
 
PROBLEM  
PROBABLE CAUSE  
CORRECTIVE MEASURES  
4) Unusually high body fat estimates  
(40-50%)  
a) Too much light present during the  
measurement.  
a) Do not lift the Light Wand from the  
subject's biceps until a "2" appears on  
the screen during the first estimation or  
the printer starts printing after the  
second estimation.  
b) Use the Light Shield to block the  
external light. Always avoid  
measurements under strong lights (e.g.  
direct sunlight) because errors may  
occur.  
5) Printer Stops  
a) Low batteries.  
a) Replace batteries (see page 3).  
b) Bad battery contact.  
c) Bad AC connection.  
b) Remove batteries and clean tabs with  
isopropyl alcohol (rubbing alcohol).  
c) Unplug the AC Adapter from the wall  
socket and from the unit. Clean the  
adapter contact with isopropyl alcohol  
(rubbing alcohol).  
30  
 
PROBLEM  
PROBABLE CAUSE  
CORRECTIVE EstimateS  
6) Print is too light or does not print.  
a) Printing on wrong side of the paper.  
b) Wrong type of printer paper.  
c) Print head is dirty.  
a) Make sure paper is inserted to print  
on the "shiny" side of the paper.  
b) Paper must be thermal paper.  
c) Clean the print head by carefully  
removing the Paper Cutter. Insert a  
clean piece of rough paper (a typical  
business card is ideal) between the print  
head and rear paper roller.  
CAUTION: Do not bend the print head;  
pressure on the rear paper roller will  
allow the card to be inserted.  
7) Printer prints black lines.  
a) Low batteries.  
a) Replace batteries (Refer to page 3).  
b) Bad battery connections.  
b) Remove batteries and clean tabs with  
isopropyl alcohol (rubbing alcohol).  
!
FOR MORE INFORMATION OR ASSISTANCE, CALL 1-301-733-9368  
31  
 
GENERAL SPECIFICATIONS  
1)  
2)  
MEASUREMENT TECHNIQUE  
! Estimation Principle:  
Near Infrared Interactance Technique based on technology from the United States  
Department of Agriculture.  
2.5% to 50%  
! Estimation Range:  
PRINTER OUTPUT  
! Fitness Analysis  
! Update Analysis  
! Color Printer  
! Physical Rating  
3)  
4)  
5)  
6)  
SERIAL PORT:  
Bi-directional synchronous 2400 baud, 8 bit, 1 stop; +/-9 volt nominal  
1 to 32,000 auto-incremented; not user resettable  
Six AA 1.5V alkaline batteries  
USER "ID" SEQUENCE:  
POWER SOURCE:  
DIMENSIONS:  
Main Body - 4.7 x 9.5 x 2.2 inches  
Light Wand - 1.2(dia.) x 4.5 (length) inches  
7)  
8)  
WEIGHT:  
2 lbs. (total)  
ACCESSORIES:  
Optical Standard  
Arm Band  
x1  
x1  
Thermal Printer Paper(rolls) x5  
(one roll is supplied installed in the instrument's  
printer. Paper must be thermal paper  
type)  
"AA" battery  
User's Manual  
Light Shield  
x6  
x1  
x1  
32  
 
KEYPAD DESCRIPTION  
Summary:  
Key Name  
ZERO ADJUST  
:
When the Display shows "Sd", insert the probe firmly into the "Optical Standard", and press this key to  
automatically calibrate the unit.  
SELECT PROGRAM:  
This key is pressed prior to the Program Keys in order to select one of the "Computation Programs".  
FITNESS  
UPDATE  
:
:
One of the "Computation Programs". This key selects the "Fitness Analysis" program.  
One of the "Computation Programs". This key selects the "Update Analysis" program.  
COLOR PRINTER  
:
:
Activates RS-232 Serial Port to send data to be printed onto the four page preprinted color form.  
SMALL  
MEDIUM  
LARGE  
These keys are used to enter your body frame size in the "Fitness Analysis" or  
the "Update Analysis" programs. Press the proper key when the "Enter body frame" message  
appears on the printer.  
MALE  
FEMALE  
:
These keys are used to enter your sex into the "Fitness Analysis" or "Update Analysis"  
programs. Press the appropriate key when the "Enter sex" message appears on the printer.  
CLEAR  
ENTER  
:
:
This key cancels incorrectly entered numbers.  
This key is used to store numbers that have been entered. It is also used to start the body fat  
estimation sequence.  
PAPER FEED  
RISKS  
:
:
:
For feeding paper into the printer.  
Allows adjustment of the instrument's calibration.  
Changes internally stored date stamp  
DATE  
33  
 
Printed in U.S.A.  
 

Eclipse Fujitsu Ten Car Stereo System CD5405 User Manual
Fisher Price Baby Toy b7553 User Manual
FMI Indoor Fireplace GM36 User Manual
Freecom Technologies Portable Multimedia Player MediaPlayer Drive In Kit User Manual
FujiFilm Digital Camera S8000FD User Manual
Fujitsu Server T5440 User Manual
Gardena Outdoor Timer T 1030 Plus User Manual
Garland Convection Oven MCO GD 10E User Manual
Garland Food Warmer E24 12H User Manual
GE Freezer GTR12 User Manual