CAPACITY  
Capacity (gallons)  
Model View  
50  
63  
First Hour Delivery (gallons)  
$198 in Hybrid Mode  
Estimate Yearly Operation Cost (@ $0.10/KWh)  
FEATURES  
Fuel Type  
Electric  
Integrated  
Yes  
Electronic Controls with LCD Display  
20 Character x 4 Line LCD Display  
Backlit LCD Display  
Yes  
Multiple Operating Modes  
TM  
eHeat  
Hybrid (Factory Default Mode*)  
High Demand  
2.35 EF  
Standard Electric  
Vacation/Away Mode  
Service Diagnostics  
Demand Response Ready  
3 to 90 days  
Integrated  
Yes  
o
Temperature Setting Range  
100 to 140 F  
Temperature Setting Factory Default  
Temperature Setting Memory  
Precise Temperature  
120oF  
Yes  
+/- 3oF  
Renewable Air Filter  
Condensate Collector  
Washable (included)  
Integrated (tubing included)*  
Side View  
Front View  
APPEARANCE  
Color Appearance  
Color Appearance Code  
Silver Metallic  
SA  
Temperature  
& Pressure  
Recommend 7”  
Min. Service  
Clearance  
POWER / RATINGS  
Electrical Power Required  
Electrical Circuit Required  
Energy Factor (EF)  
Electrical Consumption Maximum Heating  
Electrical Consumption Minimum Heating  
Electrical Consumption Standby  
Operating Air Temperature Range  
eHeatTM, Hybrid, and High Demand Modes  
Safety Valve  
240/208 Volts (L1, L2, Ground), 60 Hz  
Dedicated 30 Amp Min.  
2.35 in Hybrid Mode  
4,500 Watts  
45o  
1.5”  
550 Watts  
2.0 Watts  
Electrical  
Connections  
11”  
o
45 to 120 F  
Standard Electric Mode  
32 to 150oF  
Operating Water Pressure  
20 to 125 PSI  
Warranty  
Limited 1-year**  
Limited 10-year**  
8”  
13”  
Parts & Labor  
2nd-10th year parts only  
* Condensate tube must be directed into a drain below 36" from the floor,  
or a condensate drain pump (not included) is required.  
**See warranty for details.  
Water  
Connections  
Recommend 7” Min.  
Service Clearance  
Product Weight 200 Lbs.  
Shipping Weight 220 Lbs.  
63”  
60.5”  
Washable  
Filter  
Clearance  
14” Min  
to  
Clean Filter  
Air Vents  
Condensate Overflow Tube  
Demand  
Response  
Connection  
(3 In) Included  
Condensate Tube**  
(6 Ft) Included  
21.75” Dia.  
~
~
Temperature & Pressure  
Safety Valve Included  
 

Echo Trimmer HC 165 User Manual
Electro Voice Microphone PL68 User Manual
Excalibur electronic Home Safety Product H637S User Manual
Faber Ventilation Hood Scirocco Downdraft Rangehood User Manual
Fisher Paykel Refrigerator C240BLC240BR User Manual
Fisher Price Riding Toy H8099 User Manual
Fisher Price Tent V6892 User Manual
Gardena Heat Pump 7000 3 2 T art 1494 User Manual
Gemini Musical Instrument PS 01 User Manual
Glen Dimplex Home Appliances Ltd Refrigerator BE815 User Manual