WSK100, WSK200 and WSK210 Wall Switches
- Installation and Operating Instructions -
WARNING
CAUTION
Inspect components for damage. Damaged
parts may impair safe operation.
DO NOT DISCARD THIS MANUAL
• Important installation and operation instruc-
tions included.
•
•
•
Do NOT install damaged components.
Do NOT install incomplete components.
Do NOT install substitute components.
• Read, understand and follow these
instructions for safe installation and
operation.
Report damaged parts to dealer.
• Leave this manual with party responsible
for use and operation.
INTRODUCTION
The WSK100 and WSK200 wall switches are designed to
switch the fireplace on or off, and the pilot function activates
the pilot flame as well. These wall switches interface with
Intellifire™ systems only.
Wall Switch
Control Box
Wiring Harness
INSTALLATION PRECAUTIONS
This wall switch is tested and safe when installed in
accordance with this installation manual. Do not install
any components that may be damaged. Do not modify,
disassemble, or substitute any of the components included
with this kit. Installation of this unit must be done by a
qualified service technician.
Figure 1. Items included in the WSK100 Wall Switch Kit
Placement of this wall switch may affect performance. An
assessment of the space should be done prior to installation
for optimum performance. See Section 1.1 for location
recommendations.
Wall Switch
Control Box
Wiring Harness
NOTE: The electrical junction box provided with the fireplace
must be wired with 110 VAC before installing this kit. See
owner’s manual for details.
NOTE: All wiring should be done by a qualified electrician and
shall be in compliance with local codes and with the National
Electric Code ANSI/NFGA No. 70 - current (in the United
States), or with the current CSAC22.1 CANADIAN ELECTRIC
CODE (in Canada).
Figure 2. Items included in the WSK200 and WSK210 Wall Switch
Kit. (Delay circuit not shown).
WARNING
Shock Risk
Do NOT provide any power to this unit
until all wiring is complete.
•
May destroy parts of this device and
render it unusable.
May lead to possible electrical shock.
Printed in U.S.A. Copyright 2007
Hearth & Home Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
•
2050-910G 7/07
1
PILOT
IPI MODULE
BATTERYPACK
ON/OFF
SWITCH
BRN
BRN
NOT
USED
NOT
USED
ORG
DEXEN IPI VALVE
(7) 12" WIRES
BUNDLED
MINIMUM
GRN
BLK JUMPER
BLU
GRN
YEL
SEE DETAIL
A - A FOR
WSK210 DETAIL
RED
HIGH LIMIT SWITCH
BLK
GRN
WALL SWITCH
BLK JUMPER
DETAIL B-B
FOR B-VENT
APPLIANCES
GROUND
WSK-100/200
CONTROL BOX
J-BOX (110V)
DELAY
CIRCUIT
BATTERY
PACK
WSK210
ONLY
DETAIL A - A
Figure 3. IPI wiring diagram with WSK100, WSK200 and WSK210 Wall Switch
3
2.0 OPERATION INSTRUCTIONS
NOTE: If the fireplace has an ON/OFF rocker switch
(located near the gas valve), the switch may either be
disconnected or turned to the OFF position. Rocker
switch is not required for operation of this control.
2.1 Wall switch button operation
On/Off Button
• Button Press: Turns fireplace ON
• Button Press: Turns fireplace OFF
During severe cold weather, homeowners may find that
activating the pilot assists in lighting the fireplace. Use the pilot
button to switch from “as-needed” pilot to “constant-on”.
Pilot Button
• Button Press: Turns Pilot to “Constant-on”
• Button Press: Turns Pilot to “As-needed”
Fan Speed Button (WSK200 Only)
• Button Press: Turns fan on high
• Button Press: Turns fan on medium
• Button Press: Turns fan on low
• Button Press: Turns fan on off
3.0 TROUBLESHOOTING
Effects of Line Power Failure
The operating characteristics of your fireplace may vary during a power failure or power outage. The options listed below
will help determine the current state of your system.
Condition (at time of power failure)
Result
Wall switch is in ON mode with the main
The fireplace will shut down and the display lights in the wall switch will be off. When the
flame on and has no battery backup or has power is restored to the system, the display lights will remain unlit and the fireplace will
dead batteries.
remain off.
Wall switch is in OFF mode with the main
flame OFF and has no battery backup or
has dead batteries.
The fireplace burner is not currently lit and will stay off. The display lights in the wall
switch will be off. When the power is restored to the system, the display lights will re-
main unlit and the fireplace will remain off.
Wall switch is in ON mode with the main
The fireplace will shut down and the display lights in the wall switch will be off. When
flame on and has battery backup.
the power is restored to the system, the main burner flame and display lights will remain
off.
The wall switch is in OFF mode with the
main flame off and has battery backup.
The fireplace will stay off and the display lights in the wall switch will be off. When the
power is restored to the system, the main burner flame and display lights will remain off.
4
|